• Title/Summary/Keyword: Optimization

Search Result 21,474, Processing Time 0.053 seconds

A Study on the Performance Optimization of a Continuous Monitoring Method for Hazardous VOCs in the Ambient Atmosphere (환경대기 중 유해성 VOC에 대한 자동연속 측정방법의 성능 최적화에 관한 연구)

  • Son, Eun-Seong;Seo, Young-Kyo;Lee, Dong-Hyun;Lee, Min-Do;Han, Jin-Seok;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.6
    • /
    • pp.523-538
    • /
    • 2009
  • Recently, there has been a keen demand for real-time automatic monitoring of VOCs not only in Korea but other developed countries. We carried out this study to evaluate and to optimize the performance of a continuous automatic monitoring system for hazardous VOCs (HVOCs) in the ambient atmosphere, using an on-line GC system. The online system normally consisted of a Nafion dryer prior to a cold trap of an automatic thermal desorption apparatus and a GC system equipped with two detectors, i.e. PID and ECD. Preliminary tests conducted to check out any contamination of the system revealed an evidence of significant artifact formation of benzene, and it was found that the Nafion dryer (even brand new one) is the source of the benzene artifact. Thus, all the subsequent experiments in this study was carried out inevitably by removing the Nafion dryer. The on-line GC method was investigated with a variety of QC/QA performance criteria such as repeatability, linearity, lower detection limits, and accuracy. In order to find out the best operating condition for the on-line GC system, three different types (in terms of adsorption strength) of cold trap combinations were tested, i.e. (i) Tenax-TA and Carbopack-B combination (weak and hydrophobic); (ii) Tenax-TA, Carbopack-X and Carboxen-1000 combination (strong and hydrophilic); and (iii) Tenax-TA and Carbopack-X combination (medium and hydrophobic/hydrophilic). The USEPA TO-17 manual method was selected as a reference method to evaluate the performance of the on-line method. A series of experiments revealed that the system performance was superior to others when a cold trap packed with hydrophilic adsorbents (Tenax-TA/Carbopack-X/Carboxen-1000 combination) was used and operated at $25^{\circ}C$. However, the system with a cold trap packed with a combination of Tenax-TA and Carbopack-X is more recommended for field applications since the carboxen-1000 adsorbent is too sensitive to water vapor, and hence the performance of the system might be very unstable to humid samples or during rainy days. Furthermore, the precision and accuracy criteria of the Tenax-TA/ Carbopack-X combination were generally compatible with the triple adsorbents cold trap. The continuous automatic monitoring method is, thus, considered very useful to real-time monitoring to understand the variations of VOCs concentrations in ambient air, as it adopts much simpler procedures in sampling, analysis, and data integration steps than manual monitoring methods. However, it should be noted that there is a high possibility of benzene artifacts formation through the Nafion dryer, which is often installed to remove water vapor in air samples before being adsorbed onto the cold trap. Therefore, if a Nafion dryer is used in any studies of monitoring VOCs, the benzene contamination should be carefully examined before carrying out obtaining the data.

Simulation study of smoke spread prevention using air curtain system in rescue station platform of undersea tunnel (해저터널 구난역 플랫폼 화재연기확산 방지를 위한 에어커튼 시스템 차연성능 시뮬레이션 연구)

  • Park, Sang-Heon;An, Jung-Ju;Han, Sang-Ju;Yoo, Yong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.257-266
    • /
    • 2015
  • This study introduce that we studied optimization and possibility of smoke spread prevention with air-curtain system in undersea tunnel named from Ho-Nam to Jeju line in domestic if a fire break out in train. To verify performance, air-curtain system is installed between rescue station platform and each door of passenger car to provide safety route to evacuator and we studied simulation model of various cases about 15 MW fire severity considering domestic specifications. As a result we verified the fact that CASE1(air jet with 15degree toward passenger car) and CASE 5 (air jet with 15degree toward passenger car and pressure air blast from cross passage) is best Smoke Spread Prevention and less inflow carbon monoxide. Through above results, we expect that air-curtain system is one of the facilities for fire safety and provide us safety platform route in undersea tunnel.

Development of a back analysis program for reasonable derivation of tunnel design parameters (합리적인 터널설계정수 산정을 위한 역해석 프로그램 개발)

  • Kim, Young-Joon;Lee, Yong-Joo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.3
    • /
    • pp.357-373
    • /
    • 2013
  • In this paper, a back analysis program for analyzing the behavior of tunnel-ground system and evaluating the material properties and tunnel design parameters was developed. This program was designed to be able to implement the back analysis of underground structure by combination of using FLAC and optimized algorithm as direct method. In particular, Rosenbrock method which is able to do direct search without obtaining differential coefficient was adopted for the back analysis algorithm among optimization methods. This back analysis program was applied to the site to evaluate the design parameters. The back analysis was carried out using field measurement results from 5 sites. In the course of back analysis, nonlinear regression analysis was carried out to identify the optimum function of the measured ground displacement. Exponential function and fractional function were used for the regression analysis and total displacement calculated by optimum function was used as the back analysis input data. As a result, displacement recalculated through the back analysis using measured displacement of the structure showed 4.5% of error factor comparing to the measured data. Hence, the program developed in this study proved to be effectively applicable to tunnel analysis.

Development of evaluation model for optimum design of multi-utility tunnel in urban area (도심지 공동구 최적 설계를 위한 평가 모델 개발)

  • Sim, Young-Jong;Jin, Kyu-Nam;Oh, Won-Joon;Cho, Choong-Yeun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.437-447
    • /
    • 2017
  • In current, there has not been the evaluation model for the optimum design of the multi-utility tunnel by considering urban type and size, the function of surrounding road and feasibility analyses with respect to construction method, and arrangement of accommodation facilities inside multi-utility tunnel. Thus, in this study, we developed the evaluation model for the optimum design of the multi-utility tunnel before and after the decision of the multi-utility tunnel installation. In this paper, we have selected the Deming cycle which is used in various fields among several decision methods for optimizing the design. For the purpose of reflecting the various factors in the design of the multi-utility tunnel, 11 higher indicators were set up to lead to more detailed approaches. In addition, based on the "Plan-Do-Check-Action (PDCA)" circulation method, we can realize the installation of the multi-utility tunnel and design more efficiently through the first phase for conception and the second phase for optimization, and develop the program for the evaluation model accordingly.

Overproduction of Bacterial Trypsin in Streptomyces - Optimization for Streptomyces griseus Trypsin Production by Recombinant Streptomyces (미생물을 이용한 트립신 과대 생산 연구 - Streptomyces용 숙주-벡터계를 이용한 트립신 유전자의 대량발현 최적화 -)

  • Kim, Jong-Hee;Hong, Soon-Kwang
    • Microbiology and Biotechnology Letters
    • /
    • v.36 no.1
    • /
    • pp.28-33
    • /
    • 2008
  • The expression vector (pWHM3-TR1R2) for sprT gene encoding Streptomyces griseus trypsin (SGT) followed by two regulatory genes, sgtR1 and sgtR2, was introduced into Streptomyces lividans TK24 and Streptomyces griseus IFO 13350. Various media with different compositions were used to maximize the productivity of SGT in the recombinant trains. he SGT productivity was best when the transformant of S. lividans TK24 was cultivated in R2YE medium (0.74 unit/mL) at 5 days of cultivation. C5/L (0.66 unit/mL) medium also gave a good productivity, but Livid (0.08 unit/mL) and NDSK (0.06 unit/mL) yielded poor productivities. S. griseus IFO 13350/pWHM3-TR1R2 produced SGT by 1.518 unit/mL (C5/L), 1.284unit/mL (R2YE),0.932 unit/mL (NDSK), and 0.295 unit/mL (Livid) at 7 days of cultivation, which was much higher than those from S. lividans TK24/TR1R2. The SGT protein was purified from the culture broth of S. griseus IFO 13350/pWHM3-TR1R2 in C5/L to homogeneity via ammonium sulfate fractionation, and CM-sepharose and SP-sepharose column chromatographies. The specific activity of purified SGT was 69,252 unit/mg, and the final purification fold and recovery yield were 6.5 and 1.4%, respectively.

Optimization for SBR Process of Two-Sludge Type (Two-sludge 유형 SBR 공정의 최적 운영 조건 도출)

  • Ryu, Hong-Duck;Hwang, Jae-Sik;Kim, Keum-Yong;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.2
    • /
    • pp.229-234
    • /
    • 2007
  • In the present work, the sequencing batch reactor process of two-sludge type was optimized. The effects of solid retention time, hydraulic retention time, length of biosorption phase and temperature variation were investigated, respectively. In the T-N removal, the long solid retention time was favored. It was speculated that SCOD biosorption efficiency was higher in long solid retention time than in short solid retention time. In the comparison of hydraulic retention time, the removal efficiency of $NH_4^+-N$ and T-N were almost same in all applied hydraulic retention times which were 8 hr, 10 hr and 15 hr. It was observed that there was no need to have the hydraulic retention time more than 20 min in biosorption phase for enhancement of T-N removal efficiency. An experimental comparison of removal efficiencies with different temperature conditions was carried out. Decrease of temperature didn't affect the performance of the process, however, phosphorus removal efficiency was a little higher at low temperature than high temperature. Consequently, the process developed in this study was much amenable to wastewater treatment which was conducted in the low temperature and high loading rate.

Speciation Analysis of Arsenic Species in Surface Water (수중의 비소 종 분리 분석)

  • Jeong, Gwan-Jo;Kim, Dok-Chan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.6
    • /
    • pp.621-627
    • /
    • 2008
  • In this study, a technique of speciation and determination of the trace inorganic arsenic(As(III) and As(V)) in water sample using HPLC-DRC-ICP-MS has been developed. Isocratic mobile phase of 10 mM ammonium nitrate and 10 mM ammonium phosphate monobasic was used and methanol(5 v/v%) was used as flushing solvent. Selection of the best flow rate of reaction gas, O$_2$, and optimization of the parameters such as pH and flow rate of mobile phase, and injection volume of sample for the separation and detection of arsenic species were carried out. The oxygen flow rate of 0.5 mL/min, pH of 9.4 and flow rate of 1.5 mL/min of mobile phase, and injection volume of sample of 100 $\mu$L were found to be the best parameters for the speciation and determination of arsenic species. The analytical features of the method were detection limit 0.10 and 0.08 $\mu$g/L, precision(RSD) 4.3% and 3.6%, and recovery 95.2% and 96.4% for As(III) and As(V), respectively. Analysis time was 4 minutes per sample. Linear calibration graphs with r$^2$ = 0.998 were obtained for both As(III) and As(V). Speciation analysis of arsenic species in the raw water samples collected from the tributary streams to Han River and main stream of Paldnag were performed by the proposed method. The concentrations of As(III) ranged from 0.10 to 0.22 $\mu$g/L and As(V) concentrations ranged from 0.44 to 1.19 $\mu$g/L, and 93.5% of total arsenic was found to be As(V).

A Pre-Feasibility Test of Introducing Renewable Energy Hybrid Systems -Case Studies for 3 Off-Grid Islands- (도서지역 신·재생복합 전력시스템 보급 타당성 분석 -3개 도서지역 분석결과-)

  • Jang, HaNa;Kim, Suduk
    • Environmental and Resource Economics Review
    • /
    • v.15 no.4
    • /
    • pp.693-712
    • /
    • 2006
  • A pre-feasibility test is done for renewable energy hybrid power systems at off~grid islands in which the current power supply is provided only by diesel generation. We apply Homer (Hybrid Optimization Model for Electric Renewables) which was developed by the National Renewable Energy Laboratory (NREL) for the analysis to identify the cost-minimizing combination of power generating facilities for the given load profiles. Chuja-Do, Geomun-Do and Youngsan-Do have been selected for our analysis considering the wind resources data of the Korea Institute of Energy Research (KIER). Information on wind speed, solar radiation and temperature is also used for the analysis. System component cost information from overseas market has been used due to the lack of domestic information. Site specific Load profile for electricity demand for those islands are reconstructed based on the partial survey results obtained form other sources. The LCOE of the least cost hybrid power systems for Chuja-Do, Geomun-Do and Youngsan-Do are $0.278/kWh, $0.234/kWh and $0.353/kWh, respectively Considering the fact that diesel generation is being subsidized at the price of $0.300/kWh by the government, first 2 cases are economically feasible for the introduction of renewable energy hybrid systems to those islands. But the third case of Youngsan-Do does not meet the criteria. The basic differences of these pre-feasibility test results are from the differences of the site specific renewable energy conditions, especially wind resources. In summary, promoting hybrid systems in the off-grid remote island should be based on the economic feasibility test results. Not all the off-grid islands are feasible for introducing this renewable energy hybrid system.

  • PDF

Optimization of Bioflocculant Production Conditions for Organic Wastewater Treatment with Aeromonas hydrophila KH-54 (Aeromonas hydrophila KH-54가 분비하는 유기폐수처리용 생물응집제 생산조건의 최적화)

  • Seo, Ho-Chan;Lee, Jung-Suk;Yun, Zu-Whan;Yi, Yun-Seok;Cho, Hong-Yon
    • Applied Biological Chemistry
    • /
    • v.41 no.6
    • /
    • pp.465-470
    • /
    • 1998
  • For the need of bio-degradable flocculant in stage of wastewater treatment, some cultural conditions of bioflocculant production were optimized with Aeromonas hydrophila KH-54. About 260 strains of type culture and bacteria isolated from marsh, pond, activated sludge, etc were examined for their ability to flocculate kaolin particles and swine wastewater. Among them, KH-54 showed the highest flocculating activity and was identified as Aeromonas hydrophila according to the cultural, morphological and physiological properties. The maximum production of the flocculant secreted by Aeromonas hydrophila KH-54 was observed in culture medium containing 2.0% mannitol, 0.05% ammonium chloride, 0.02% potassium phosphate dibasic, 0.01% $MgSO_4{\cdot}7H_2O$ and 0.05% yeast extract at initial pH 7.0 when cultured on rotary shaker controlled at $25^{\circ}C$ and 150 rpm. Under the optimized condition, the flocculating ability reached to 770 units/ml of kaolin flocculating activity and 81% of NTU removal efficiency against swine wastewater after 4 days cultivation. The bioflocculant was also effective on various organic wastewaters other than swine wastewater, showing NTU removal rate ranging from 92% to 34%.

  • PDF

Density Measurement Technique and Prediction Model of Fruit Juices under Freezing Point (빙점이하에서 과일쥬스의 밀도측정방법 및 예측모델)

  • Bae, Dong Ho;Choi, Yong Hee
    • Current Research on Agriculture and Life Sciences
    • /
    • v.6
    • /
    • pp.163-169
    • /
    • 1988
  • This study was conducted to predict the density changes according to concentration and temperature changes under freezing point. This information is needed for the design of freezing equipment and for the efficient utilization of refrigerating system. Orange juice, Apple juice, Grape juice and Sucrose solution were used for the measurement of density in this study at the temperature range from $-5^{\circ}C$ to $-40^{\circ}C$ and at the concentration range from 10 to 40%. The unfrozen water fraction of samples was determined by Heldman's method. The density values were determined by measuring the weight of a frozen solution at each temperature with a known volume. Solutions were placed in the thick-walled aluminum tubes. When the solution was frozen the excess ice was removed with a razor until the surface of the ice was flush with the top of the aluminum tube. The tube and ice were weighted immediately. Knowing the volume, tare weight, and final weight, the density could be determined. With this procedure, the data of density and unfrozen water fraction for fruit juices and sucrose solution were collected. The density prediction models of fruit juices and sucrose solution under freezing point were established by the optimization computer program with measured experimental data.

  • PDF