• Title/Summary/Keyword: Optimal design and operation

Search Result 725, Processing Time 0.029 seconds

Hot-Carrier Degradation of NMOSFET (NMOSFET의 Hot-Carrier 열화현상)

  • Baek, Jong-Mu;Kim, Young-Choon;Cho, Moon-Taek
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3626-3631
    • /
    • 2009
  • This study has provided some of the first experimental results of NMOSFET hot-carrier degradation for the analog circuit application. After hot-carrier stress under the whole range of gate voltage, the degradation of NMOSFET characteristics is measured in saturation region. In addition to interface states, the evidences of hole and electron traps are found near drain depending on the biased gate voltage, which is believed to the cause for the variation of the transconductance($g_m$) and the output conductance($g_{ds}$). And it is found that hole trap is a dominant mechanism of device degradation in a low-gate voltage saturation region, The parameter degradation is sensitive to the channel length of devices. As the channel length is shortened, the influence of hole trap on the channel conductance is increased. Because the magnitude of $g_m$ and $g_{ds}$ are increased or decreased depending on analog operation conditions and analog device structures, careful transistor design including the level of the biased gate voltage and the channel length is therefore required for optimal voltage gain ($A_V=g_m/g_{ds}$) in analog circuit.

Sensitivity Analysis of Satellite BUV Ozone Profile Retrievals on Meteorological Parameter Errors (기상 입력장 오차에 대한 자외선 오존 프로파일 산출 알고리즘 민감도 분석)

  • Shin, Daegeun;Bak, Juseon;Kim, Jae Hwan
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.3
    • /
    • pp.481-494
    • /
    • 2018
  • The accurate radiative transfer model simulation is essential for an accurate ozone profile retrieval using optimal estimation from backscattered ultraviolet (BUV) measurement. The input parameters of the radiative transfer model are the main factors that determine the model accuracy. In particular, meteorological parameters such as temperature and surface pressure have a direct effect on simulating radiation spectrum as a component for calculating ozone absorption cross section and Rayleigh scattering. Hence, a sensitivity of UV ozone profile retrievals to these parameters has been investigated using radiative transfer model. The surface pressure shows an average error within 100 hPa in the daily / monthly climatological data based on the numerical weather prediction model, and the calculated ozone retrieval error is less than 0.2 DU for each layer. On the other hand, the temperature shows an error of 1-7K depending on the observation station and altitude for the same daily / monthly climatological data, and the calculated ozone retrieval error is about 4 DU for each layer. These results can help to understand the obtained vertical ozone information from satellite. In addition, they are expected to be used effectively in selecting the meteorological input data and establishing the system design direction in the process of applying the algorithm to satellite operation.

Development of Water Quality Management System in Daecheong Reservoir Using Geographic Information System (GIS를 이용한 저수지의 수질관리시스템 구축)

  • 한건연;백창현
    • Spatial Information Research
    • /
    • v.12 no.1
    • /
    • pp.13-27
    • /
    • 2004
  • The current industrial development and the increase of population in Daecheong Reservoir basin have produced a rapid increase of wastewater discharge. This has resulted in problem of water quality control and management. Although many efforts have been carried out, reservoir water quality has not significantly improved. In this sense, the development of water quality management system is required to improve reservoir water quality. The goal of this study is to design a GIS-based water quality management system for the scientific water quality control and management in the Daecheong Reservoir. For general water quality analysis, WASP5 model was applied to the Daecheong Reservoir. A sensitivity analysis was made to determine significant parameters and an optimization was made to estimate optimal values. The calibration and verification were performed by using observed water quality data for Daecheong Reservoir. A water quality management system for Daecheong Reservoir was made by connecting the WASP5 model to ArcView. It allows a Windows-based Graphic User Interface(GUI) to implement all operation with regard to water quality analysis. The proposed water quality management system has capability for the on-line data process including water quality simulation, and has a post processor far the reasonable visualization for various output. The modeling system in this study will be an efficient NGIS(National Geographic Information System) far planning of reservoir water quality management.

  • PDF

Enhancement of combustion efficiency of a air-cooled combustor system with single F.D. Fan Using CFD (전산유체역학을 이용한 단일 송풍기가 적용된 공냉식 연소설비의 효율개선)

  • Kim, Min-Choul;Shon, Byung-Hyun;Lee, Jae-Jeong;Park, Hung-Suck
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.460-468
    • /
    • 2021
  • This study investigated the enhanced combustion efficiency of an "air-cooled combustion system" with single F.D. fan, and performed a numerical analysis for the operation and design conditions to increase the combustion efficiency. The combustion efficiency in an actual combustor was compared before and after the structure modification. Numerical analysis for application of a single fan revealed the difficulty of forming a turbulence for circular combustion conditions. This is because the supply ratio of combustion air supplied into 2 flow paths becomes irregular in the combustion furnace due to a change in friction force and pressure in each flow path. Subsequently, two methods of supplying air into the combustion furnace were analyzed numerically to obtain the optimal combustion conditions of an air-cooled combustion system. The first method involved injecting the preheated combustion air after a 180~360 degree rotation from the outer wall, whereas in the second method, the combustion air was injected into the combustion furnace in a tangential direction after primary heat exchange outside the combustion furnace, by applying a rotatable vane structure in the combustion furnace. Results reveal that application of a single F.D. fan to the air injection into a rotatable combustion furnace is desirable for optimization of the combustion conditions for applying a duct structure having a dual cooling wall for the cooling of the outer wall of the combustion furnace, and for maintaining perfect mixing in the combustion furnace. We therefore confirmed enhanced combustion efficiency by comparing the actual combustion efficiency before and after structure modification.

A Design of High Efficiency Distributed Amplifier Using Optimum Transmission Line (최적 전송 선로를 이용한 고효율 분산형 증폭기의 설계)

  • Choi, Heung-Jae;Ryu, Nam-Sik;Jeong, Young-Chae;Kim, Chul-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.1
    • /
    • pp.15-22
    • /
    • 2008
  • In this paper, we propose a numerical analysis on reversed current of distributed amplifier based on transmission line theory and proposed a theory to obtain optimum transmission line length to minimize the reversed currents by cancelling those components. The reversed current is analyzed as being simply absorbed into the terminal resistance in the conventional analysis. In the proposed analysis, however, they are designed to be cancelled by each other with opposite phase by the optimal length of the transmission lint Circuit simulation and implementation using pHEMT transistor were performed to validate the proposed theory with the cutoff frequency of 3.6 GHz. From the measurement, maximum gain of 14.5dB and minimum gain of 12.3dB were achieved In the operation band. Moreover, measured efficiency of the proposed distributed amplifier is 25.6% at 3 GHz, which is 7.6%, higher than the conventional distributed amplifier. Measured output power Is about 10.9dBm, achieving 1.7dB higher output power than the conventional one. Those improvement is thought to be based on the cancellation of refersed current.

An Effectiveness Analysis of pedestrian crosswalk signal on roundabout (회전교차로의 보행신호 설치효과 분석)

  • Moon, Joo-Baek;Lee, In-Kyu;Kim, Young-Chan
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.2
    • /
    • pp.63-75
    • /
    • 2013
  • Roundabouts have been operated in Europe, America and Australia since the 1970s, and many relevant researches continually was carried out. Though many studies regarding roundabout have been recently conducted in korea, most of them have focused on its operational safety and efficiency. Moreover, roundabout design guideline did not define a clear criteria related to pedestrian in roundabout, but seldom investigate the influences of pedestrian on crosswalk. In this study, we seek ways to operate the pedestrian crosswalk signal on roundabout maximizing their operational effects in exceptional case such as rush hour or intersection near the special facilities. We proved that roundabout signal operation is effective under certain circumstances in according to the number of pedestrian, and suggested the optimal signal timing plan for signalized roundabouts. For pursuing the above, we conducted the simulation test using the VISSIM model. The results show that the operational effectiveness of signalized roundabout was evaluated to be better than non-signalized roundabout in specific pedestrian volume condition. In addition, those results are confirmed using simulation analysis conducted on the real roundabout.

Decomposition Characteristics of Fungicides(Benomyl) using a Design of Experiment(DOE) in an E-beam Process and Acute Toxicity Assessment (전자빔 공정에서 실험계획법을 이용한 살균제 Benomyl의 제거특성 및 독성평가)

  • Yu, Seung-Ho;Cho, Il-Hyoung;Chang, Soon-Woong;Lee, Si-Jin;Chun, Suk-Young;Kim, Han-Lae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.9
    • /
    • pp.955-960
    • /
    • 2008
  • We investigated and estimated at the characteristics of decomposition and mineralization of benomyl using a design of experiment(DOE) based on the general factorial design in an E-beam process, and also the main factors(variables) with benomyl concentration(X$_1$) and E-beam irradiation(X$_2$) which consisted of 5 levels in each factor was set up to estimate the prediction model and the optimization conditions. At frist, the benomyl in all treatment combinations except 17 and 18 trials was almost degraded and the difference in the decomposition of benomyl in the 3 blocks was not significant(p > 0.05, one-way ANOVA). However, the % of benomyl mineralization was 46%(block 1), 36.7%(block 2) and 22%(block 3) and showed the significant difference of the % that between each block(p < 0.05). The linear regression equations of benomyl mineralization in each block were also estimated as followed; block 1(Y$_1$ = 0.024X$_1$ + 34.1(R$^2$ = 0.929)), block 2(Y$_2$ = 0.026X$_2$ + 23.1(R$^2$ = 0.976)) and block 3(Y$_3$ = 0.034X$_3$ + 6.2(R$^2$ = 0.98)). The normality of benomyl mineralization obtained from Anderson-Darling test in all treatment conditions was satisfied(p > 0.05). The results of prediction model and optimization point using the canonical analysis in order to obtain the optimal operation conditions were Y = 39.96 - 9.36X$_1$ + 0.03X$_2$ - 10.67X$_1{^2}$ - 0.001X$_2{^2}$ + 0.011X$_1$X$_2$(R$^2$ = 96.3%, Adjusted R$^2$ = 94.8%) and 57.3% at 0.55 mg/L and 950 Gy, respectively. A Microtox test using V. fischeri showed that the toxicity, expressed as the inhibition(%), was reduced almost completely after an E-beam irradiation, whereas the inhibition(%) for 0.5 mg/L, 1 mg/L and 1.5 mg/L was 10.25%, 20.14% and 26.2% in the initial reactions in the absence of an E-beam illumination.

Development and assessment of pre-release discharge technology for response to flood on deteriorated reservoirs dealing with abnormal weather events (이상기후대비 노후저수지 홍수 대응을 위한 사전방류 기술개발 및 평가)

  • Moon, Soojin;Jeong, Changsam;Choi, Byounghan;Kim, Seungwook;Jang, Daewon
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.11
    • /
    • pp.775-784
    • /
    • 2023
  • With the increasing trend of extreme rainfall that exceeds the design frequency of man-made structures due to extreme weather, it is necessary to review the safety of agricultural reservoirs designed in the past. However, there are no local government-managed reservoirs (13,685) that can be discharged in an emergency, except for reservoirs over a certain size under the jurisdiction of the Korea Rural Affairs Corporation. In this case, it is important to quickly deploy a mobile siphon to the site for preliminary discharge, and this study evaluated the applicability of a mobile siphon with a diameter of 200 mm, a minimum water level difference of 6 m, 420 (m2/h), and 10,000 (m2/day), which can perform both preliminary and emergency discharge functions, to the Yugum Reservoir in Gyeongju City. The test bed, Yugum Reservoir, is a facility that was completed in 1945 and has been in use for about 78 years. According to the hydrological stability analysis, the lowest height of the current dam crest section is 27.15 (EL.m), which is 0.29m lower than the reviewed flood level of 27.44 (EL.m), indicating that there is a possibility of lunar flow through the embankment, and the headroom is insufficient by 1.72 m, so it was reviewed as not securing hydrological safety. The water level-volume curve was arbitrarily derived because it was difficult to clearly establish the water level-flow relationship curve of the reservoir since the water level-flow measurement was not carried out regularly, and based on the derived curve, the algorithm for operating small and medium-sized old reservoirs was developed to consider the pre-discharge time, the amount of spillway discharge, and to predict the reservoir lunar flow time according to the flood volume by frequency, thereby securing evacuation time in advance and reducing the risk of collapse. Based on one row of 200 mm diameter mobile siphons, the optimal pre-discharge time to secure evacuation time (about 1 hour) while maintaining 80% of the upper limit water level (about 30,000 m2) during a 30-year flood was analyzed to be 12 hours earlier. If the pre-discharge technology utilizing siphons for small and medium-sized old reservoirs and the algorithm for reservoir operation are implemented in advance in case of abnormal weather and the decision-making of managers is supported, it is possible to secure the safety of residents in the risk area of reservoir collapse, resolve the anxiety of residents through the establishment of a support system for evacuating residents, and reduce risk factors by providing risk avoidance measures in the event of a reservoir risk situation.

A study on the Degradation and By-products Formation of NDMA by the Photolysis with UV: Setup of Reaction Models and Assessment of Decomposition Characteristics by the Statistical Design of Experiment (DOE) based on the Box-Behnken Technique (UV 공정을 이용한 N-Nitrosodimethylamine (NDMA) 광분해 및 부산물 생성에 관한 연구: 박스-벤켄법 실험계획법을 이용한 통계학적 분해특성평가 및 반응모델 수립)

  • Chang, Soon-Woong;Lee, Si-Jin;Cho, Il-Hyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.1
    • /
    • pp.33-46
    • /
    • 2010
  • We investigated and estimated at the characteristics of decomposition and by-products of N-Nitrosodimethylamine (NDMA) using a design of experiment (DOE) based on the Box-Behken design in an UV process, and also the main factors (variables) with UV intensity($X_2$) (range: $1.5{\sim}4.5\;mW/cm^2$), NDMA concentration ($X_2$) (range: 100~300 uM) and pH ($X_2$) (rang: 3~9) which consisted of 3 levels in each factor and 4 responses ($Y_1$ (% of NDMA removal), $Y_2$ (dimethylamine (DMA) reformation (uM)), $Y_3$ (dimethylformamide (DMF) reformation (uM), $Y_4$ ($NO_2$-N reformation (uM)) were set up to estimate the prediction model and the optimization conditions. The results of prediction model and optimization point using the canonical analysis in order to obtain the optimal operation conditions were $Y_1$ [% of NDMA removal] = $117+21X_1-0.3X_2-17.2X_3+{2.43X_1}^2+{0.001X_2}^2+{3.2X_3}^2-0.08X_1X_2-1.6X_1X_3-0.05X_2X_3$ ($R^2$= 96%, Adjusted $R^2$ = 88%) and 99.3% ($X_1:\;4.5\;mW/cm^2$, $X_2:\;190\;uM$, $X_3:\;3.2$), $Y_2$ [DMA conc] = $-101+18.5X_1+0.4X_2+21X_3-{3.3X_1}^2-{0.01X_2}^2-{1.5X_3}^2-0.01X_1X_2+0.07X_1X_3-0.01X_2X_3$ ($R^2$= 99.4%, 수정 $R^2$ = 95.7%) and 35.2 uM ($X_1$: 3 $mW/cm^2$, $X_2$: 220 uM, $X_3$: 6.3), $Y_3$ [DMF conc] = $-6.2+0.2X_1+0.02X_2+2X_3-0.26X_1^2-0.01X_2^2-0.2X_3^2-0.004X_1X_2+0.1X_1X_3-0.02X_2X_3$ ($R^2$= 98%, Adjusted $R^2$ = 94.4%) and 3.7 uM ($X_1:\;4.5\;$mW/cm^2$, $X_2:\;290\;uM$, $X_3:\;6.2$) and $Y_4$ [$NO_2$-N conc] = $-25+12.2X_1+0.15X_2+7.8X_3+{1.1X_1}^2+{0.001X_2}^2-{0.34X_3}^2+0.01X_1X_2+0.08X_1X_3-3.4X_2X_3$ ($R^2$= 98.5%, Adjusted $R^2$ = 95.7%) and 74.5 uM ($X_1:\;4.5\;mW/cm^2$, $X_2:\;220\;uM$, $X_3:\;3.1$). This study has demonstrated that the response surface methodology and the Box-Behnken statistical experiment design can provide statistically reliable results for decomposition and by-products of NDMA by the UV photolysis and also for determination of optimum conditions. Predictions obtained from the response functions were in good agreement with the experimental results indicating the reliability of the methodology used.

A Study on Movement of the Free Face During Bench Blasting (전방 자유면의 암반 이동에 관한 연구)

  • Lee, Ki-Keun;Kim, Gab-Soo;Yang, Kuk-Jung;Kang, Dae-Woo;Hur, Won-Ho
    • Explosives and Blasting
    • /
    • v.30 no.2
    • /
    • pp.29-42
    • /
    • 2012
  • Variables influencing the free face movement due to rock blasting include the physical and mechanical properties, in particular the discontinuity characteristics, explosive type, charge weight, burden, blast-hole spacing, delay time between blast-holes or rows, stemming conditions. These variables also affects the blast vibration, air blast and size of fragmentation. For the design of surface blasting, the priority is given to the safety of nearby buildings. Therefore, blast vibration has to be controlled by analyzing the free face movement at the surface blasting sites and also blasting operation needs to be optimized to improve the fragmentation size. High-speed digital image analysis enables the analyses of the initial movement of free face of rock, stemming optimality, fragment trajectory, face movement direction and velocity as well as the optimal detonator initiation system. Even though The high-speed image analysis technique has been widely used in foreign countries, its applications can hardly be found in Korea. This thesis aims at carrying out a fundamental study for optimizing the blast design and evaluation using the high-speed digital image analysis. A series of experimentation were performed at two large surface blasting sites with the rock type of shale and granite, respectively. Emulsion and ANFO were the explosives used for the study. Based on the digital images analysis, displacement and velocity of the free face were scrutinized along with the analysis fragment size distribution. In addition, AUTODYN, 2-D FEM model, was applied to simulate detonation pressure, detonation velocity, response time for the initiation of the free face movement and face movement shape. The result show that regardless of the rock type, due to the displacement and the movement velocity have the maximum near the center of charged section the free face becomes curved like a bow. Compared with ANFO, the cases with Emulsion result in larger detonation pressure and velocity and faster reaction for the displacement initiation.