• Title/Summary/Keyword: Optimal Technique

Search Result 3,174, Processing Time 0.032 seconds

Forging Die Design for Vent Forming of Square Cup Battery Case (사각 컵 배터리 케이스 바닥 벤트 성형을 위한 단조 금형 설계)

  • Lee, Sang-Hoon;Kwon, Soon-Ho;Chung, Hoon;Hong, Seokmoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.330-335
    • /
    • 2017
  • The demand for electric motor fuel cells has surged in the automotive industry, leading to a recent increase in the demand for square aluminum cans used as fuel cell battery casings. The air vent located on the bottom of the rectangular battery casing prevents large explosions by intermittent pressure release prior to the accumulation of abnormally high pressures. Conventionally, the square cup battery casing is produced via six-step deep drawing, with the outer shape of the vent being manufactured by welding to the square battery casing. On the other hand, this study directly incorporated the air vent outlet into the bottom surface of the rectangular casing. The product of a coupled finite element analysis technique applying the thickness and contour generated from the square cup multi-step deep drawing formation analysis was used as the forging input shape. The results yielded increased prediction accuracy and the advanced prediction of defects, such as swelling and fracture. Based on the results of the initial analyses, two of the generated forging shapes were determined to be suitable, with the optimal forging shape being determined by molding analysis. The results presented here were validated by mold fabrication and a subsequent comparison of the actual and analytical results.

Selective Removal of Arsenic Compounds from the Contaminated Paddy Soil in China Using Froth Flotation Technique (포말부선 기술을 이용한 중국 오염농경지내 비소화합물의 선택적 제거)

  • Lee, Seungwoo;Jeon, Chilsung;Lee, Eunseong;Yoo, Kyungmin;Choi, Junhyun;Kim, Hyunjung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.7
    • /
    • pp.343-352
    • /
    • 2016
  • Effects of grinding time and chemicals dosage in arsenic removal from contaminated paddy soil in China were investigated using lab scale attrition and froth flotation combining process. Arsenic concentration in the field soil was 76.51 mg/kg, exceeding Korean and Chinese standards, and predominant arsenic compounds fraction in sequential extraction was "residual" (over 80%). After wet sieving, soil with >2 mm and < 0.038 mm showed concentration lower than 'Warning Level' in Korea. Soil with 0.038-0.075 mm, showing the highest concentration, was discarded since it occupied minor weight fraction (10.1%). Thus soil between 0.075 and 2 mm was only used in the combining process. The highest Arsenic concentration in progeny fragments smaller than 0.038 mm reached up to 981.66 mg/kg after 5 min of attrition. Optimal dosage of collector ($C_5H_{11}OCS_2K$) and modifier ($Na_2S$ and $CuSO_4$) in froth flotation process for the selective separation of the chipped progeny particles from the parent fragments were determined both as 200 g/ton. Arsenic removal efficiency in froth flotation process was 38.47% and it was increased to 72.74% in additional flotation process, scavenging. Average arsenic concentration after overall process - wet sieving, attrition and froth flotation - was estimated to 16.45 mg/kg.

A Study on the Assessment of Source-term for PWR Primary System Using MonteCarlo Code (MonteCarlo 코드를 이용한 PWR 일차 계통 선원항 평가에 관한 연구)

  • Song, Jong Soon;Lee, Sang Heon;Shin, Seung Su
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.3
    • /
    • pp.331-337
    • /
    • 2018
  • The decommissioning of nuclear power plants is generally executed in five steps, including preparation, decontamination, cutting/demolition, waste disposal and environmental restoration. So, for efficient decommissioning of nuclear power plants, worker safety, effects compared to cost, minimization of waste, possibility of reuse, etc., shall be considered. Worker safety and measurement technology shall be secured to exert optimal efficiency of nuclear power plant decommissioning work, for which accurate measurement technology for systems and devices is necessary. Typical In-Situ methods for decommissioning of nuclear plants are CZT, Gamma Camera and ISOCS. This study used ISOCS, which can be applied during the decommissioning of a nuclear power plant site without collecting representative samples, to take measurements of the S/G Water Chamber. To validate the measurement values, Microshield and the GEANT4 code was used as the actual method were used for modeling, respectively. The comparison showed a difference of $1.0{\times}10^1Bq$, which indicates that it will be possible to reduce errors due to the influence of radiation in the natural environment and the precision of modeling. Based on the research results of this paper, accuracy and reliability of measurement values will be analyzed and the applicability of the direct measurement method during the decommissioning of NPPs will be assessed.

An Analysis of Optimal Sequences for the Detection of Wake-up Signal in Disaster-preventing Broadcast (재난방송용 대기모드 해제신호 검출을 위한 최적 부호 성능 분석)

  • Park, Hae Yong;Jo, Bonggyun;Kim, Heung Mook;Han, Dong Seog
    • Journal of Broadcast Engineering
    • /
    • v.19 no.4
    • /
    • pp.491-501
    • /
    • 2014
  • Recently, the need for disaster-preventing broadcast has increased gradually to cope with natural disaster like earthquake and tsunami causing enormous losses of both life and property. In disaster-preventing broadcast system, the wake-up signal is used to alert user terminal and switch the current state of channel to the emergency channel, which is for the fast and efficient delivery of emergency information. In this paper, we propose the detection method of wake-up signal for disaster-preventing broadcast systems. The wake-up signals for disaster-preventing broadcast should have a good auto-correlation property in low power and narrow-band conditions that does not affect the existing digital television (DTV) system. The suitability of the m-sequence and complementary code (CC) is analyzed for wake-up signals according to signal to noise ratio. A wake-up signal is proposed by combining the direct sequence spread spectrum (DSSS) technique and pseudo noise (PN) sequences such as Barker and Walsh-Hadamard codes. By using the proposed method, a higher detecting performance can be achieved by the spreading gain compared to the single long m-sequence and the Golay code.

The Resolving Method of Graft-Tunnel Mismatch in Arthroscopic ACL Reconstruction Using Bone-Patellar Tendon-Bone Graft (골-슬개건-골을 이용한 관절경적 전방십자인대 재건술시 이식물-터널 길이의 부조화를 줄이는 방법)

  • Cho, Se-Hyun;Park, Hyung-Bin;Ha, Sung-Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.2
    • /
    • pp.97-101
    • /
    • 1999
  • Purpose : The purpose of this study is to prevent thc graft-tunnel mismatch by measuring the patellar tendon length, intertunnel distance, tibial tunnel length and by obtaining appropriate bone block length. Materials and Methods : Authors analyzed 15 patients who had taken the anterior cruciate ligament reconstruction from March 1997 to June 1999. Tibial guide was always set on the "endo" $40^{\circ}$ position(Acufex, MA, USA). We measured the following indices, intertunnel distance(X), tibial tunnel length(T), patellar tendon length(N), tibia bone plug length(Y). Both of the femoral tunnel length(F) and the patellar bone plug length(P) were made in 25mm. The appropriate tibial bone plug length was simply calculated by subtracting the patellar tendon length from the sum of the intertunnel distance and thc tibial tunnel length(Y=X+T-N). Results : The average indices were as follows ; the intertunnel distance(X) was $23.4{\pm}1.4mm$, the tibial tunnel length(T) was $43.6{\pm}1.7mm$, the patellar tendon length was $40{\pm}2.4mm$, and the tibia bone plug length was $27{\pm}2.4mm$. Conclusion : In authors' endoscopic technique, establishment of individually determined optimal tibial bone plug length, based on total tunnel length and patellar tendon length could prevent the problem of graft-tunnel mismatch.

  • PDF

Assessment of Power Generation by Pressure Retarded Osmosis Process from Spiral-Wound Membrane Pilot-Plant (나권형 모듈을 이용한 압력지연삼투 공정의 에너지생산에 관한 연구)

  • Go, Gil hyun;Park, Tae shin;Kang, Lim seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.9
    • /
    • pp.476-481
    • /
    • 2016
  • Pressure retarded osmosis (PRO) is a quite new technique for power generation using an osmotically driven membrane process. In the PRO process, water permeates through a semipermeable membrane from a low concentration feed solution to a high concentration draw solution due to osmotic pressure. This study carried out to evaluate the performance of the 8 in spiral wound membrane module using reverse osmosis concentrate for a draw solution and reverse osmosis permeate for a feed solution. Three different flowrates of draw and feed solution, such as 2.4 L/min, 5.0 L/min, and 10.0 L/min were used to estimate the power density and water flux under various range of hydraulic pressure differences between 5 bar and 30 bar. In addition, the effects of feed and draw solution concentration, flowrate, and mixing ratio on 8 in spiral wound PRO membrane module performance were investigated in this study. As major results, increases of the draw solution concentration lead to the improvement of power denstiy, and water flux. Also, increase of flowrate resulted in the improvement of power density and water flux. In addition, optimal mixing ratio of draw and feed solution inlet flowrate was found to be 1:1 to attain a maximum power denstiy.

Evaluation of the Physical Properties for Lightweight Bricks Made from Sewage Sludge and Wasted Glass (하수슬러지로 제조한 경량 벽돌의 물성평가)

  • Jeong, Jae-Ah;Son, Yeong-Geum;Lee, Woo-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.11
    • /
    • pp.781-784
    • /
    • 2013
  • Ocean dumping of sewage sludge is banned. Therefore, it is needed to develop alternative treatment method. Sewage sludge and waste glass are used to prepare lightweight brick. Large amount of energy is consumed to prepare building material, because of its high preparation temperature, or above $1,200^{\circ}C$. We study to prepare lightweight brick, using sewage sludge and waste glass as raw materials in this research. Lightweight brick was made at low temperature of below $800^{\circ}C$ to reduce $CO_2$ emission by geopolymer technique. Calcination temperature, mixing ratio of sewage sludge/waste glass and water glass/water were discussed to evaluate their effect on the brick prepared. In this study, the optimal conditions for preparing bricks was $750^{\circ}C$ of firing temperature, 1.5 of mixing ratio for water glass/water and 10 : 90 wt% of sewage sludge/waste glass. At this condition, compressive strength and specific gravity of brick prepared were 5.1 MPa and 0.46, respectively. These values satisfy the criteria on a lightweight brick.

A Study on the Characteristics of Livestock Manure Treatment Facility in Korea (국내 가축분뇨 처리시설 형태별 특성조사 분석)

  • Jeong, Kwang-Hwa;Kim, Jung-Kon;Khan, Modabber Ahmed;Han, Duk-Woo;Kwag, Jung-Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.4
    • /
    • pp.28-44
    • /
    • 2014
  • Due to development of the national economy growth, livestock goods consumption has rapidly increased over the past 30 years. It has led livestock breeders to increase their livestock numbers. An increased number of livestock have consequently resulted in an increasing animal feces generation. According to the agricultural statistics provided by the Bureau of Statistics, livestock manure amounts to 47,235 thousand tons in 2013. To treat livestock manure, various types of treatment facilities like composting, liquid fertilization, purification, and anaerobic digestion facilities are being applied. In composting facility, there are four kinds of agitation system: escalator, paddle, screw and rotary type. In case of liquid fertilization process, there are two types of system: aeration and anoxic type. There are about 8,000 liquid fertilization facilities for treatment livestock manure in Korea. For purification of livestock manure, the treatment process is divided by three steps: Solid/Liquid separation process, Secondary purification process and advanced oxidation process. About 21 thousand tons of livestock manure was treated by anaerobic digestion facility in 2012. In every type of facility for livestock manure treatment, it is very important to choose the optimal deodorization equipment for the livestock manure treatment facility. In this study, the investigation has been carried out for six years to analyse the characteristics of livestock manure treatment facilities and related technique of Korea.

Tethered Cord Syndrome; Surgical Indication, Technique and Outcome

  • Kang, Joon-Ki;Lee, Kwan-Sung;Jeun, Sin-Soo;Kang, Seok-Gu;Lee, Il-Woo;Yoon, Kang-Jun;Ha, Sang-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.2
    • /
    • pp.77-82
    • /
    • 2007
  • Objective : The authors tried to reveal some unique features of lipomeningomyelocele (LMMC), including clinical presentation, factors precipitating onset of symptoms, pathologic entities of LMMC associated with tethered cord syndrome, and surgical outcome in LMMC patients. Methods : Seventy-five patients with LMMC were enrolled in this study. Neuro-imaging and intraoperative findings allowed classification of LMMC into three Types. The patients were divided into two groups by age : A (51 patients), from birth to 3 years, and B (24 patients), from 3 to 24 years. For prevention of retethering of the cord, a mega-dural sac rebuilding procedure was performed in 15 patients. Results : During a mean postoperative follow-up period of 4 years, the surgical outcome was satisfactory in terms of improved pain and motor weakness, but disappointing with reference to the resolution of bowel and bladder dysfunction. Among these 75 patients with LMMC, preoperative deficits were improved after surgery in 29 (39%), remained stable in 28 (37%), changed slightly in 13 (17%), and worsened in 5 (7%). Patients in group A achieved better outcomes than those in group B. Depending on the type of lesion, patients with types I and II LMMC have better outcomes than those with type III LMMC. Finally, retethering of the cord with neurological deterioration occurred in 4 (5.3%) of the 75 patients, but no retethering was found in the 15 patients who were recently treated with a mega-dural sac rebuilding procedure. Conclusion : Our data continue to support the opinion that early diagnosis and optimal surgery are still essential for the treatment of patients with LMMC, since there is a high likelihood of residual neurological functions that can be preserved. Based on our surgical experience of untethering and decompression of lipomas, a mega-dural sac repair is useful to prevent retethering of the cord.

The DSRR Organizing Algorithm for Efficient Mobility Management in the SIP (SIP에서의 효율적인 이동성 관리를 위한 방향성 사전등록영역 구성 알고리즘)

  • 서혜숙;한상범;이근호;황종선
    • Journal of KIISE:Information Networking
    • /
    • v.31 no.5
    • /
    • pp.490-500
    • /
    • 2004
  • In mobile/wireless environment, mobility management is widely being focused as one popular researches. But, disruption happens when messages are exchanged between nodes as registration is made after handoff, and unnecessary traffic occurs because of the use of the Random-walk model, in which the probability for MN to move to neighboring cells is equal. In order to solve these problems, this study proposes a technique and algorithm for composing Directional Shadow Registration Region (DSRR) that provides seamless mobility. The core of DSRR is to prevent disruption and unnecessary traffic by minimizing the number o) neighboring cells with a high probability of handoff (AAAF). This study sensed the optimal time for handoff through regional cell division by introducing a division scheme, and then decided DSRR, the region for shadow registration, by applying direction vector (DV) obtained through directional cell sectoring. According to the result of the experiment, the proposed DSRR processes message exchange between nodes within the intra-domain, the frequency of disruptions decreased significantly compared to that in previous researches that process in inter-domain environment. In addition, traffic that occurs at every handoff happened twice in DSRR compared to n (the number of neighboring cells) times in Previous researches. As an additional effect, divided regions obtained from the process of composing DSRR filter MN that moves regardless of handoff.