• Title/Summary/Keyword: Optimal Penetration Rate

Search Result 40, Processing Time 0.029 seconds

Studies on the Optimal Sterilization Conditions of Red Pepper Paste Packed in Retort Pouch. (레토르트 파우치 고추장의 적정 고온 살균조건에 관한 연구)

  • Lee, Shin-Young;Choi, Kook-Chi;Lee, Sang-Kyu
    • Journal of Industrial Technology
    • /
    • v.3
    • /
    • pp.87-94
    • /
    • 1983
  • Heating characteristics of red pepper paste packed in report pouches of various thicknesses and their storage stability were investigated to determine the adequate processing conditions that good bacteriological safty and minimal quality changes could be obtained, when sterilized by using a steam-air system retort. A heat penetration into pouch-packed red pepper paste was carried out through by a conductive heat transfer, indicating a simple logarithmic heating curve, and the smaller thickness revealed the higher heat penetration rate, suggesting the possibility of high temperature-short time sterilization of red pepper paste. The processing conditions with Fo-value of 4.5 or higher were sufficient for keeping up bacterial safty, but based on C-value, better quality retention was obtained at pouch thickness of 15mm under the processing temperature of $120^{\circ}C$. Subsequent storage study revealed that the red pepper paste packed in 15mm and processed at $120^{\circ}C$ with Fo=4.5 could be held without any spoilage and overall acceptance change, when stored for 6 months at room temperature under the relative humidity of 70%. After 3 months storage in $38^{\circ}C$ under saturation humidity, overall acceptance of red pepper paste were judged not to be maintainable on the acceptable level, but it may be suggested that above the results could be kept up a desirable quality without any remarkable deterioration.

  • PDF

Optimal Clustering of Energy Storage System for Frequency Regulation Service Considering Life Degradation (수명감소를 고려한 주파수 조정용 에너지저장장치의 최적 클러스터링)

  • Kim, Wook-Won;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.555-560
    • /
    • 2016
  • Recently, many countries have placed great attention on energy security and climate changes. Governments are promoting the construction of renewable energy projects with regulatory support in Korea. Despite an increasing penetration of renewable resources, however, the photovoltaic and wind power are underutilized due to the endemic problems such as difficulties of output control and intermittent output. The Energy Storage System (ESS) is proposed as a good solution for solving the problems and has been studied in both the private business and the government. However, because of inefficient aspects, the research has been carried out for improving high costs and a small capacity. In addition, the ESS is currently installed for using only one purpose which is frequency regulation or transmission congestion relief such that has an economic limitation. Therefore, methods which are becoming economically justifiable to increase the penetration of the ESS is required. Thus, this paper presents in terms of operation efficiency to improve economic feasibility of the ESS currently used. mainly, there are two aspects for the operation efficiency. Firstly, it is intended to improve the utilization rate through a process that can utilize the ESS for various purposes. It is necessary to be able to use for other purposes by classifying and clustering for increasing the efficiency of availability. The clustering method is proposed to conduct the grouping the ESS. Especially, it is proposed to utilize ESS for frequency regulation service which is the one of ancillary services in the power system. Through case studies, it is confirmed to secure the necessary resources by clustering small size ESS.

Analysis of Advanced Rate and Downtime of a Shield TBM Encountering Mixed Ground and Fault Zone: A Case Study (단층대와 복합지반을 통과하는 쉴드TBM의 굴진율 및 다운타임 발생 특성 분석)

  • Jeong, Hoyoung;Kim, Mincheol;Lee, Minwoo;Jeon, Seokwon
    • Tunnel and Underground Space
    • /
    • v.29 no.6
    • /
    • pp.394-406
    • /
    • 2019
  • Difficult ground conditions (e.g., fault zone and mixed grounds) are highly probable to appear in subsea and urban tunnels because of the shallow working depth and alluvial characteristics. TBM usually experienced decrease of penetration rate and increase of downtime when it meets these difficult ground conditions. The problems are usually caused by the adverse geological conditions, and it is preferable to determine the optimal operational parameters of TBM based on the previous operational data obtained while excavating a preceding tunnel. This study carried out for efficient TBM excavation in fault zone and mixed grounds. TBM excavation data from the tunnel site in Singapore and the characteristics of the TBM excavation data was analyzed. The key operational parameters (i.e., thrust, torque, and RPM), penetration rate, and downtime were highly influenced by the presence of fault zones and mixed grounds, and the features was discussed. It is expected that the results and main discussions will be useful information for future tunneling projects in similar geological conditions.

INTERFERENCE CHARACTERISTICS OF CONSTRUCTION ENVIRONMENT FOR WSN APPLICATIONS

  • Sun-Chan Bae;Won-Sik Jang;Sang-Dae Park;Won-Suk Jang
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.592-595
    • /
    • 2013
  • Advent of Wireless Sensor Networks (WSN) has provided potentials to a variety of construction applications. It is well appreciated that WSNs have advantages over traditional wired system, such as ease of installation and maintenance with increased cost savings and efficiencies. However, the obstruction of wireless signal from physical objects in the heterogeneous construction environment often brings challenges to WSN measurement system. This paper analyzed the obstruction characteristic of construction environment where construction materials, equipment, and built structures obstruct the wireless signal yielding negative effect of measurement system. By adopting evaluation criteria, such as packet reception rate, field experiments have been implemented to quantitatively identify the interference of wireless signal from penetration, reflection, and network traffic under the construction environment. The results show that reliable performance of wireless sensor in construction environment depends on the optimal separation distance between a receiver and a transmitter, obstruction types, obstruction thickness, and transmission interval. In addition, the methodology and experimental results of this paper could be used in the practical design of network topology when hundreds of sensor nodes form a mesh network in the large scale construction applications.

  • PDF

Optimizing welding parameters of laser-arc hybrid welding onto aluminum alloy via grey relational analysis (Grey relational analysis를 이용한 알루미늄 합금의 레이저-아크 하이브리드 용접조건 최적화)

  • Kim, Hang-Rae;Park, Yeong-U;Lee, Gang-Yong;Lee, Myeong-Ho;Jeong, U-Yeong;Kim, Seon-Hyeon
    • Proceedings of the KWS Conference
    • /
    • 2006.10a
    • /
    • pp.253-255
    • /
    • 2006
  • Grey relational analysis has been carried out to develop a new approach for optimization of Nd:YAG laser and MIG hybrid welding parameters. The quality of welded material depends on welding parameters. The parameters chosen for current study include wire type, shielding gas, laser energy, laser focus, traveling speed, and wire feed rate. The welding experiments were performed on 6K21-T4 aluminum alloy sheet. Functional demands on products may vary widely depending on their use. The ultimate tensile stress, width, and penetration were chosen as the optimization criterion. Practice based on an orthogonal array which is following Taguchi's method has been progressed. Base on the results of grey relational analysis, the optimal process parameters were obtained. This integrated work was judged and it is observed that the results obtained by using the optimal parameters are much improved compared to those obtained through initial setting.

  • PDF

기술 및 수요속성에 따른 정보통신서비스 확산 패턴

  • Kim, Mun-Su;Kim, Ho
    • Journal of Technology Innovation
    • /
    • v.11 no.2
    • /
    • pp.71-89
    • /
    • 2003
  • Since technological innovation, adoption, and diffusion is a fundamental engine for a company's competitiveness and in turn a nation's industrial development, diffusion of technological innovation has been one of popular research themes to many researchers and scholars for decades. Especially, in today's knowledge-based economy, the IT technology became a fundamental infrastructure for a nation and thus their impact on a nation's economy has grown to be tremendous. This paper investigates the patterns of technological diffusion of 16 telecommunications services. Firstly, we identify the optimal diffusion model which represents the 15 IT innovation best in terms of goodness-of-fit. Secondly, based on the best model identified we cluster the 16 IT innovations according to their diffusion characteristics such as penetration rate and diffusion speed. Lastly, we categorize the innovations in terms of technology (voice-based innovation and data-based innovation) and demand (household-use and business-use) attributes, and compare their diffusion patterns and found some meaningful difference in diffusion patterns. We hope the result helpful to corporate managers as well as policy makers in relevant areas.

  • PDF

A Computational Fluid Dynamics Analysis on an Electrohydrodynamics Induction Micropump (전기수력학적 유도 마이크로 펌프에 대한 전산유체역학 해석)

  • Lee, Byoung-Seo;Lee, Joon-Sik
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1851-1856
    • /
    • 2008
  • A numerical program based on computational fluid dynamics has been developed to simulate characteristics of an EHD induction micropump. The ambiguity of boundary conditions was removed by adopting an equation formulated for electric potential as the dependent variable. The calculations show that the dependency of frequency agrees well with the experiments and the previous analysis. The instability, caused by backflows, is getting stronger as the channel depth increases, which is consistent with experiments. The present study reveals that it is due to the limit in the penetration depth which the electric field can affect. Despite the disadvantage of large channel depth, there is a certain optimal depth for the maximum flow rate.

  • PDF

Predicted Optimum Efficiency due to Changes in the Design Parameters of the Small Electrostatic Precipitator (설계인자 변화에 따른 소형 전기집진장치의 최적효율 예측)

  • Suh, Jeong-Min;Yi, Pyong-In;Jung, Moon-Sub;Park, Jeong-Ho;Lim, Woo-Taik;Park, Chool-Jae;Choi, Kum-Chan
    • Journal of Environmental Science International
    • /
    • v.22 no.9
    • /
    • pp.1187-1197
    • /
    • 2013
  • The result of a small electrostatic precipitator which is in order to decrease indoor air pollution for optimal efficiency was shown as follows. Although the closer distance between the discharge electrode and dust collecting electrode shows the better throughput efficiency by forming strong electrostatic Field, it does not have profound impact in case of optimal dust collecting area. G.P(gas passage) which is the distance from dust collecting electrode to dust collecting electrode is a crucial factor to decide dust collecting efficiency. The narrower distance of G.P shows the better throughput efficiency whereas it decreases when the distance is too narrow since sparks ensue by increasing the capacity of electrostatic charging system 5 mm regards as optimal efficiency in this experiment. Although the higher voltage shows the higher dust collecting efficiency overall, the experiment was not able to keep performing since the sparks which decrease dust collecting efficiency ensue over 40 kV. The efficient and safe voltage state is considered 3.6 kV in this experiment. The most crucial factor for dust collecting efficiency of an electrostatic precipitator which is in order to decrease indoor air pollution is applied voltage. In addition, optimal raw gas flow rate(2.4 m/sec) is more important factor than the excessive increase of dust collecting area.

A Study on the Optimal System Sizing of the Standalone Photovoltaic Power Generation System for Uninterruptible Power Supply (독립형 태양광 발전 시스템의 무정전 전력공급을 위한 시스템 용량 최적 선정에 관한 연구)

  • Kim, Ki-Young;Choi, Woojin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.2
    • /
    • pp.77-85
    • /
    • 2018
  • Renewable energy has been increasingly used and widely acclaimed as one of the solutions to rampant environmental problems. Among numerous kinds of renewable sources, the penetration rate of the PV system is relatively higher than that of others due to ease of installation. However, one disadvantage of the PV system is its dependence on weather condition. The PV system is especially critical when it is used for standalone systems because it cannot operate when the power generated from a PV module is not enough. Therefore, PV systems are often used with an energy storage system, such as batteries, to store backup energy when the weather condition is insufficient to supply power to the system. Blackout time can be reduced by increasing the size of the energy storage system, but it is a trade-off with system cost. In this work, optimal sizing of a standalone PV system is proposed to supply power to the system without blackout. The sizing of PV modules and batteries is performed by a simulation based on actual irradiation data collected during the past five years. The Life cycle costing of each system is evaluated to determine an optimal set of PV modules and batteries among several different combinations. The standalone PV system designed by the proposed method can supply power to the system with no interruption as long as the weather condition is similar to those of the past five years.

The Heart Rate Monitoring System using Inverted Photoplethysmography (반전 용적맥파 신호를 이용한 심박 모니터링 시스템)

  • Lee, Jun-Yeon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.3
    • /
    • pp.105-111
    • /
    • 2012
  • Photoplethysmogram is widely used to measure heart rate and arterial blood oxygen saturation in human. This paper describes implementation a photoplethysmography monitoring system that uses 780nm and 940nm length infrared light in radial artery. That system used combinations of 8 LEDs and 2 photoelectricities. When recorded on the skin over radial artery, the radial pulse wave was inverted. The mechanism of inverted pulse wave skin, which was reduced during systolic period and increase during diastolic period of the cardiac cycle. Through this system, we discovered optimal environments and combinations of sensors in both penetration type and reflection type. These results suggest that radial arterial wall way reflect infrared ray.