• 제목/요약/키워드: Optimal Operation Line

Search Result 212, Processing Time 0.032 seconds

The uses of Optimal Power Flow in Competitive Electric Power market (경쟁적 전력시장 하에서의 최적조류계산 응용에 관한 연구)

  • Hur, Dong;Park, Jong-Keun;Kim, Balho H.
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.8
    • /
    • pp.379-387
    • /
    • 2001
  • This paper shows that we can make simple modifications to an existing optimal power flow(OPF) algorithm that minimizes generation costs in order to solve the maximization of social welfare objective of the OPF in a competitive electric power market. We have illustrated the potential for the use of OPF in light of the marked impacts on nodal prices and generation/demand allocation levels among competing suppliers. This paper can provide all market players with the transparent information that ensures sufficient control over producers and consumers in case of economic of secure operation with transmission line outage while maximizing the sum of participants social benefit of participating in the electricity energy market.

  • PDF

A Study on the Second Phase Operating Patterns for Taking into Consideration the First Phase Transport Demand of Line9 (9호선 1단계 수송수요를 고려한 2단계 열차운행방안에 대한 연구)

  • Shin, Hyoung-Shik;Chung, Su-Young;Kim, Min-Soo
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.498-508
    • /
    • 2011
  • First phase section of line 9 which had been constructed by first private capitalization business of Seoul city was opened on July 24, 2009. There are 25 stations of 25.5km operation distance between Gaehwa and Sinnonhyeon, running regular and express trains on the same track. The number of daily passenger demand has risen to above 200thousand passengers with record above 90% of anticipatied transport demand in 2010. The construction of second phase section(Sinnonhyeon~Bohoon Hospital : 14km, 13 stations) is currently under construction for opening in 2016. This study aims to suggest optimal operating patterns taking into consideration theoretical operating headways for regular and express trains, demand of rolling stocks mainly analyzed on record of first phase demand of line 9 and anticipated transport demand of second phase basic plan.

  • PDF

On Line LS-SVM for Classification

  • Kim, Daehak;Oh, KwangSik;Shim, Jooyong
    • Communications for Statistical Applications and Methods
    • /
    • v.10 no.2
    • /
    • pp.595-601
    • /
    • 2003
  • In this paper we propose an on line training method for classification based on least squares support vector machine. Proposed method enables the computation cost to be reduced and the training to be peformed incrementally, With the incremental formulation of an inverse matrix in optimization problem, current information and new input data can be used for building the new inverse matrix for the estimation of the optimal bias and Lagrange multipliers, so the large scale matrix inversion operation can be avoided. Numerical examples are included which indicate the performance of proposed algorithm.

Input Current Characteristics of a Three-Phase Diode Rectifier with Capacitive Filter under Line Voltage Unbalance Condition (커패시터 필터를 갖는 3상 다이오드 정류회로의 불평형전원에서의 입력전류 특성)

  • 정승기;이동기;박기원
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.4
    • /
    • pp.348-361
    • /
    • 2001
  • The three-phase diode rectifier with capacitive filter is highly sensitive to line voltage unbalance. Because of its inherent nonlinear characteristics, small line voltage unbalance may cause highly unbalanced line current, causing detrimental effects on power quality. This paper presents a theoretical basis on this 'unbalance amplification effect' and derives an analytical model of line current characteristics under unbalanced line voltage condition for various modes of operation. The results provide a basic guideline for optimal design of a three-phase diode rectifier with capacitive filter that is most commonly used for interfacing various power conversion equipments to power lines.

  • PDF

Cooperation Schemes of the LTC and SC for Distribution Volt/Var Compensation

  • Choi, Joon-Ho
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.4
    • /
    • pp.207-213
    • /
    • 2004
  • In this paper, the on-line volt/var control algorithms of the Load Tap Changer (LTC) transformer and Shunt Capacitor (SC) are proposed for distribution volt/var compensation. In the existing volt/var control of the distribution substation, the feeder voltage and reactive power demand of the distribution are mainly controlled by the LTC transformer tap position and on/off operation of the Sc. It is very difficult to maintain volt/var at the distribution networks within the satisfactory levels due to the discrete operation characteristics of the LTC and SC. In addition, there is the limitation of the LTC and SC operation times, which affects their functional lifetimes. The proposed volt/var control algorithm determines an optimal tap position of the LTC and on/off status of the SC at a distribution substation with multiple connected feeders. The mathematical equations of the proposed method are introduced. A simple case study is performed to verify the effectiveness of the proposed method.

An analysis of automatic assembly system using petri nets (페트리 네트를 이용한 자동화 조립 시스템의 분석)

  • 최준열;안인석;이노성;장석호;박승규;우광방
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.336-341
    • /
    • 1993
  • Automatic Assembly Systems(AAS) are a class of systems exhibiting concurrency, asynchronicity and distributedness, and can be modeled by Petri Nets. In this paper, we design two types of configuration of part-assembly system in the car manufacturing line, as an example of AAS. And, we make a modeling the system by utilizing Extended Petri Nets, simulation as varying machine parameters, and analysis of operation status. These enable to present the information of optimal status and various problems occurring in the system for achieving high production rate.

  • PDF

Analysist of Instantaneous Current Tracking Control Inverter Characteristics for Photovoltaic System (태양광 발전용 순시치 전류제어형 인버터의 특성 해석)

  • 조금배;김한성
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.5
    • /
    • pp.770-778
    • /
    • 1994
  • In this paper, the photovoltaic inverter system with instantaneous sinusoidal current tracking control is proposed to improve the utilization factor of photovoltaic power system which would be connected utility interactive system. The proposed inverter is designed to track maximum power point by two-state value control method and utility interactive operation, and to decrease output harmonics component. Optimal operating region is described by state space averaging method, and present tracking condition of standard guide line. The experimental result shows the effectiveness of inverter system using the instantaneous control method.

Practical diagnostic technique for catenary surge arrester in electric railway (전차선로용 피뢰기 진단기법 적용 연구)

  • Han, Moon-Seob;Jang, Dong-Uk;Jung, Ho-Sung;Kil, Gyung-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1631-1633
    • /
    • 2005
  • This paper describes the measurement result of leakage current flowing arrestors connected in catenary line to propose an optimal management methods. 27 arrestors set in 7 locations were tested. The leakage currents are included a harmonics of electric train during the operation of electric train in feeding section and in case of feeding earthing system.

  • PDF

Security Cost Analysis with Linear Ramp Model using Contingency Constrained Optimal Power Flow

  • Lyu, Jae-kun;Kim, Mun-Kyeom;Park, Jong-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.3
    • /
    • pp.353-359
    • /
    • 2009
  • This paper proposes a novel technique for calculating the security costs that properly includes ramping constraints in the operation of a deregulated power system. The ramping process is modeled by a piecewise linear function with certain assumptions. During this process, a ramping cost is incurred if the permissible limits are exceeded. The optimal production costs of the power producers are calculated with the ramping cost included, considering a time horizon with N-1 contingency cases using contingency constrained optimal power flow (CCOPF), which is solved by the primal-dual interior point method (PDIPM). A contingency analysis is also performed taking into account the severity index of transmission line outages and its sensitivity analysis. The results from an illustrative case study based on the IEEE 30-bus system are analyzed. One attractive feature of the proposed approach is that an optimal solution is more realistic than the conventional approach because it satisfies physical constraints, such as the ramping constraint.

A Study on the Optimal Introduction of Step Voltage Regulator(SVR) in Distribution Feeders (고압배전선로용 선로전압조정장치(SVR)의 최적 도입방안에 관한 연구)

  • Lee Eun-Mi;Kim Mi-Young;Rho Dae-Seok;Sohn Sang-wook;Kim Jae-Eon;Park Chang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.11
    • /
    • pp.610-618
    • /
    • 2004
  • With the development of industry and the improvement of living standards, better quality in power electric service is required more than ever before. Under these circumstances, to deliver reasonable voltage regulation methods in distribution systems need to be developed. So, This paper deals with optimal introduction of the line voltage regulator (SVR : Step Voltage Regulator) in power distribution systems. First, This paper investigates characteristics of SVR and performs economic evaluation of SVR's introduction by using Present Worth Method. This paper, also suggests proper location and optimal voltage regulation algorithm. In order to deliver suitable voltages to as many customers as possible, the optimal sending voltage of SVR should be decided by the effective operation of voltage regulators at the distribution feeders. The simulation results using a model distribution system and real distribution systems show that the proposed methods can be a practical tool for the voltage regulation in distribution systems.