• Title/Summary/Keyword: Optics problem

Search Result 166, Processing Time 0.027 seconds

Performance Evaluation of MTF Peak Detection Methods by a Statistical Analysis for Phone Camera Modules

  • Kwon, Jong-Hoon;Rhee, Hyug-Gyo;Ghim, Young-Sik;Lee, Yun-Woo
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.150-155
    • /
    • 2016
  • To evaluate the autofocusing performance of recent mobile phone cameras, it is necessary to determine the peak position of the center field MTF (Modulation Transfer Function), -known as the through focus MTF- of the module. However, the MTF peak position found by conventional methods deviates from the ideal position due to the focus scanning resolution of mobile phone cameras. This inaccurate peak position results in false judgements of the optical performance, leading to yield losses or customer complaints. An increase in the focus scanning resolution can address this problem, but the manufacturing UPH (Unit per Hour) level will also unfortunately increase as well, resulting in a loss of manufacturing capabilities. In this paper, several fitting models are studied to find an accurate MTF peak position within a short period of time. With an analysis of a large amount of manufacturing data, it is demonstrated that the fitting methods can reduce false judgements and simultaneously increase the capabilities of the manufacturing system.

A Study on the Manufacturing Technology of the Aspheric Lens using Injection Molding (사출금형을 이용한 비구면 렌즈의 제조기술에 관한 연구)

  • Choi H. Z.;Lee S. W.;Kang E. G.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2002.02a
    • /
    • pp.76-83
    • /
    • 2002
  • The injection molding of the plastic optics is basically same as the conventional molding except it requires very intricate control of all the molding processing parameters. In the plastic optics, the problem of injection molding is the shrinkage. The shrinkage must be removed and predicted. This shrinkage is becoming more important than any other problems in precision molding because it can affect the focal length of a lens or the total performance of the optical system. This study focused on avoiding the shrinkage that the mold design allows for the optics. In making mold, the surface accuracy(P-V) of the lower and lower mold are $0.201{\mu}m\;and\;0.434{\mu}m$ respectively. A surface roughness(Ra) is below $0.02{\mu}m$ due to selecting the appropriate tools and using the injection molding machine in high degree. In injection molding of the plastic lens, mold temperature, resine temperature and injecting pressure are important process parameters. Injection molding process is carried out according to varying mold temperature and injecting pressure. As a result P-V(peak to valley) of spheric lens is $3.478{\mu}m$ and that of aspheric lens is $1.786{\mu}m$.

  • PDF

Measurement of the Modulation Transfer Function of Infrared Imaging System by Modified Slant Edge Method

  • Li, Hang;Yan, Changxiang;Shao, Jianbing
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.381-388
    • /
    • 2016
  • The performance of a staring infrared imaging system can be characterized based on estimating the modulation transfer function (MTF). The slant edge method is a widely used MTF estimation method, which can effectively solve the aliasing problem caused by the discrete undersampling of the infrared focal plane array. However, the traditional slant edge method has some limitations such as the low precision of the edge angle extraction and using the approximate function to fit the edge spread function (ESF), which affects the accuracy of the MTF estimation. In this paper, we propose a modified slant edge method, including an edge angle extraction method that can improve the precision of the edge angle extraction and an ESF fitting algorithm which is based on the transfer function model of the imaging system, to enhance the accuracy of the MTF estimation. This modified slant edge method presents higher estimation accuracy and better immunity to noise and edge angle than other traditional methods, which is demonstrated by the simulation and application experiments operated in our study.

Destripe Hyperspectral Images with Spectral-spatial Adaptive Unidirectional Variation and Sparse Representation

  • Zhou, Dabiao;Wang, Dejiang;Huo, Lijun;Jia, Ping
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.752-761
    • /
    • 2016
  • Hyperspectral images are often contaminated with stripe noise, which severely degrades the imaging quality and the precision of the subsequent processing. In this paper, a variational model is proposed by employing spectral-spatial adaptive unidirectional variation and a sparse representation. Unlike traditional methods, we exploit the spectral correction and remove stripes in different bands and different regions adaptively, instead of selecting parameters band by band. The regularization strength adapts to the spectrally varying stripe intensities and the spatially varying texture information. Spectral correlation is exploited via dictionary learning in the sparse representation framework to prevent spectral distortion. Moreover, the minimization problem, which contains two unsmooth and inseparable $l_1$-norm terms, is optimized by the split Bregman approach. Experimental results, on datasets from several imaging systems, demonstrate that the proposed method can remove stripe noise effectively and adaptively, as well as preserve original detail information.

Improvement of One-Cycle Controller Response with a Current Mode Controller

  • Ruzbehani, Mohsen;Zhou, Luowei;Mirzaei, Nasser
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.21-26
    • /
    • 2010
  • The most important feature of the one-cycle control method is its excellent ability in line disturbance rejection. However, when it is used as a controller in dc-dc converters, it has an undesirable transient response. The voltage overshoot at the transient time, which usually exists in one-cycle controlled converters, is unwanted in many applications and it is sometimes hazardous. In this paper, it is shown that the combination of a one-cycle controller with a current mode controller, can improve the transient response and consequently the overshoot can be controlled. Therefore, the combined controller has the excellent line disturbance rejection of a one-cycle controller and the output current limiting capability of current mode controllers. Because in this scheme a one-cycle controller is the master controller, the problem of instability of current mode control, will not happen. By simulation and a practical prototype, the capability of the method is shown.

A Study of Eyewear Design For Competitive Power (안경디자인의 경쟁력 제고을 위한 연구)

  • Park, Seung-On
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.37-42
    • /
    • 2001
  • Optical design highly influer.ces consumer purchase and is a major factor of price decision in the optical industry. The price is varied based on designs. Eyewear design produces more added value than other products. Design and brand name are the foundation of rapid growth. while technology and quality control are basics of competitive optical design. Currently, China, Hongkong and other Asian countries are closely following Korea in the optical industry. There should be problem solving methods based on design and brand competition and export growth probability will be improved when continue various efforts emphasizing design.

  • PDF

Kepler's Scientific Problem Finding and the Abductive Reasoning in his Discovery of the Retinal Image Formation (Kepler의 망막 상 이론 형성 과정에서의 과학적 문제 발견과 귀추적 사고)

  • Kim, Young-Min
    • Journal of The Korean Association For Science Education
    • /
    • v.26 no.7
    • /
    • pp.835-842
    • /
    • 2006
  • The aims of this study are to investigate how Kepler found a scientific problem for the retinal image theory and how abductive reasoning was used in his theory development, and to find implications for teaching creativity in science class from his thinking processes in the scientific discovery. Through the analysis of the related literatures, it was found that Kepler's problem finding in his retinal image theory came from the critical analysis of contemporary theories of vision, based on his relevant knowledge of optics, as he formulated his own hypothesis to build a new theory in eye vision employing optical phenomenon in spherical lens, which is a kind of abductive reasoning. From the results, three suggestions are proposed, that: (a) in the development of creativity teaching material, the situations like Kepler's problem finding need to be included in the programs; (b) it should be taught that relevant scientific knowledge is important for problem finding and hypothesis formulating; and (c) the experience of successful problem solving by themselves could help them find new scientific problem(s).

A Study on Prescription of RGP Contact Lens in Korean Optometrist (안경사의 RGP콘택트렌즈 처방 실태조사)

  • Kim, Young-Hoon;Baarg, Saangbai;Kim, Kwang-Bae;Kim, Dae-Hyoun;Lim, Byung-Kwan;Sun, Kyoung-Ho
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.7-17
    • /
    • 2007
  • There has been an increase in rigid gas permeable contact lens prescription by the optometrists in Korea since 1995. Therefore, the aim of our study was to find out which equipment is needed for adequate RGP contact lens prescription and the level of the clinical knowledge that they have and the level of education for the patient, to seize about the extended lens education programmes for the Korean optometrist. Also, we tried to figure out the problem that they had in the RGP contact lens prescription, to develope the educational programs for students and to improve legal uncertainties, through this research. The result came out with the following through questionnaires of 400 male and female opticians who is in clinical field. The distributions of respondents are 270 male (67.5%), 130 female (32.5%), and 356 optometry major (89%). We found out the optometry-majored people had faster clinical lens prescriptions (p=0.000), 72.5% of opticians prescribe the RGP-Lenses, and 27.5% do not because of laking in experience (P=0.000). They responded that they need slit-lamp, button lamp, fluorescein dry paper, and etc,for prescription or fitting test. In regular-check-up (Follow-up), the result came out very low by 83% of respondents who are not getting it regularly. And 83.5% (334 people) of them wanted to have those Extended Educational Programs and also the Clinical Education Programs.

  • PDF

3D Target Tracking System using Adaptive Disparity Motion Vector (프레넬 렌즈의 영상 왜곡 보정을 위한 최적의 광학설계)

  • Ko, Jung-Hwan;Lee, Jung-Suk
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1205-1206
    • /
    • 2008
  • In the conventional floating display system some image distortions might be occurred in the floating image plane, in which a flat screen has been mostly used for providing an adequate input image plane. In this paper, as a new approach to alleviate image distortion problem in a floating display system, a curved screen is suggested by through some computer simulation using an optics design program of Light Tools.

  • PDF

A study on the accuracy of optotypes test chart (자동 시력표 정확도에 관한 연구)

  • Song, Kyung-Sek;Kim, Tae-Hun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.111-118
    • /
    • 2005
  • The optotypes widely used as a necessity in the course of optometry are the world authorized versions which contain items such as the Landolt's rings, Snellen's chart and also Arabian numbers, Korean letters, Pictures and so on. In Korea, the Hahn-chun-suk test chart has been In use generally alolng with Chung-san test chart and Jin-yong-han test chart also in use on the wall. But these sort of test charts hung on the wall have some problems such as the difference in test results owing to the rate of illumination and so a more accurate method is required. To solve the problem of inaccuracy in optometry, the projected type of charts with digital instrument such as the beam projector has been developed lately. This chart projector with consistent high resolution and the ability to provide various charts can help eye examiner perform effective examination and thus is looked positively upon as the automated total optometry system. So in this study our purpose is to examine the accuracy of the projected chart. It was done by comparing it with the frequently used test chart. The results of experiment are as follow. When the projected chart was used, cases that subject read charts one step higher were 10%, two step higher 2% than perfectly corrected vision. When Han-chun-suk test chart was used, cases that subject read charts one step higher were 12%, and two step higher were 4%.

  • PDF