Effects of Self-Made Bismuth Shield Installation on Entrance surface Dose Reduction during Endovascular Treatment of Cerebral Aneurysms (뇌동맥류 코일 색전술시 자체 제작한 Bismuth 차폐체 설치의 피부선량 감소 효과)

  • Kim, Jae-Seok;Kim, Young-Kil;Choi, Jae-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.175-183
    • /
    • 2019
  • Cerebral nervous system intervention has been reported frequently due to radiation exposure such as blistering of the skin, hair loss, and erythema due to prolonged procedures. By applying ergonomically manufactured Bismuth (atomic number 83; Bi) shield to endovascular treatment of cerebral aneurysms, we aimed to minimize radiation exposure of scalp and lens from medical radiation exposure. The measurement site was the posterior part of the head, bilateral temporal part, bilateral quadriceps part, nose part, and the measuring part was attached to the optically stimulated Luminescence dosimeter (OSLD) Before and after the use, the entrance surface dose was compared and analyzed. The average entrance surface dose of group A (unshield) was 92.44 mGy, and group B was measured at 67.55 mGy. The average decrease in Group B was 26.92% compared to Group A. The entrance surface dose mean of the occipital region was measured at 146.08 mGy B group at 103.23 mGy and decreased by an average of 29.32% in group B compared to group A. The average entrance surface dose of the bilateral temporal part was measured in group A at 101.90 mGy group B at 72.69 mGy and decreased by an average of 28.67% in group B compared to group A. The average entrance surface dose for bilateral quadriceps part was measured at 27.51 mGy group B at 21.39 mGy and averaged 22.26% less in group B than group A. It is believed that the use of bismuth shields will be an alternative to reducing radiation disturbance due to temporary hair loss and other stochastic effects that may occur after the endovascular treatment of cerebral aneurysms procedure.

A Study on Superficial Dose of 6MV-FFF in HalcyonTM LINAC: Phantom Study (HalcyonTM 선형가속기 6MV-FFF 에너지의 표재 선량에 대한 고찰: Phantom Study)

  • Choi, Seong Hoon;Um, Ki Cheon;Yoo, Soon Mi;Park, Je Wan;Song, Heung Kwon;Yoon, In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.31-39
    • /
    • 2020
  • Purpose: The aims of this study were to compare the superficial dose with Optically Stimulated Luminescence Dosimeter(OSLD) measurement and Treatment Planning System(TPS) calculation for 6MV-Flattening Filter Free(FFF) energy using HalcyonTM and TrueBeamTM. Materials and methods: Phantom study was performed using the CT images of human phantom. In the treatment planning system, the Planning Target Volume(PTV) was contoured which is similar to Glottic cancer. Furthermore, Point(M), Point(R), and Point(L) were contoured at the iso-center of head and neck region and 5mm bolus was applied to the body contour. Each treatment plans using 6MV-FFF energy from HalcyonTM and TrueBeamTM with static Intensity Modulated Radiation Therapy(IMRT) and Volumetric Modulated Arc Therapy(VMAT) were established with eclipse. To reproduce the same position as the TPS, OSLDs were placed at the iso-center point and 5mm bolus was applied to compare the error rate after the dose delivery. Result: The results of the study using human phantom are as follows. In case of HalcyonTM, the mean absolute error rates of the point dose using the treatment planning system and the dose measured by OSLD were 1.7%±1.2% for VMAT and 4.0±2.8% for IMRT. Also TrueBeamTM was identified as 2.4±0.4% and 8.6±1.8% respectively for VMAT and IMRT. Conclusion: Through the results of this study, TrueBeamTM confirmed that the average error rate was 2.4 times higher for VMAT and 3.6 times higher for IMRT than HalcyonTM. Therefore, based on the results of this study, If we need a more accurate dose assessment for the superficial dose, It is expected that using HalcyonTM would be better than TrueBeamTM.

Evaluation of HalcyonTM Fast kV CBCT effectiveness in radiation therapy in cervical cancer patients of childbearing age who performed ovarian transposition (난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 난소선량 감소를 위한 HalcyonTM Fast kV CBCT의 유용성 평가 : Phantom study)

  • Lee Sung Jae;Shin Chung Hun;Choi So Young;Lee Dong Hyeong;Yoo Soon Mi;Song Heung Gwon;Yoon In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.73-82
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the effectiveness of reducing the absorbed dose to the ovaries and the quality of the CBCT image when using the HalcyonTM Fast kV CBCT of cervical cancer patients of child-bearing age who performed ovarian transposition Materials and Methods : Contouring of the cervix and ovaries required for measurement was performed on the computed tomography images of the human phantom (Alderson Rando Phantom, USA), and three Optically Stimulated Luminescence Dosimeter(OSLD) were attached to the selected organ cross-section, respectively. In order to measure the absorbed dose to the cervix and ovaries in the TruebeamTM pelvis mode (Hereinafter referred to as TP), The HalcyonTM Pelvis mode (Hereinafter referred to as HP) and The HalcyonTM Pelvis Fast mode (Hereinafter referred to as HPF), An image was taken with a scan range of 17.5 cm and also taken an image that reduced the Scan range to 12.5cm. A total of 10 cumulative doses were summed, It was replaced with a value of 23 Fx, the number of cervical cancer treatments, and compared In additon, uniformity, low contrast visibility, spatial resolution, and geometric distortion were compared and analyzed using Catphan 504 phantom to compare CBCT image quality between equipment. Each factor was repeatedly measured three times, and the average value was obtained by analysing with the Doselab (Mobius Medical Systems, LP. Versions: 6.8) program. Results: As a result of measuring absorbed dose by CBCT with OSLD, TP and HP did not obtain significant results under the same conditions. The mode showing the greatest reduction value was HPF versus TP. In HPF, the absorbed dose was reduced by 39.8% in the cervix and 19.8% in the ovary compared to the TP in the scan range of 17.5 cm. the scan range was reduced to 12.5 cm, absorbed dose was reduced by 34.2% in the cervix and 50.5% in the ovary. In addition, result of evaluating the quality of the image used in the above experiment, it complied with the equipment manufacturer's standards with Geometric Distortion within 1mm (SBRT standard), Uniformity HU, LCV within 2.0%, Spatial Resolution more than 3 lp/mm. Conclusion: According to the results of this experiment, HalcyonTM can select more various conditions than TruebeamTM in treatment of fertility woman who have undergone ovarian Transposition , because it is important to reduce the radiation dose by CBCT during radiation therapy. So finally we recommend HalcyonTM Fast kV CBCT which maintains image quality even at low mAs. However, it is consider that the additional exposure to low doses can be reduced by controlling the imaging range for patients who have undergone ovarian transposition in other treatment machines.

Burial Age and Flooding-origin Characteristics of Coastal Deposits at Gwangseungri, Gochanggun, Korea (고창군 광승리 연안 퇴적층의 퇴적 시기와 범람 기원 특성)

  • Kim, Jong Yeon;Yang, Dong Yoon;Shin, Won Jeong
    • Journal of the Korean earth science society
    • /
    • v.36 no.3
    • /
    • pp.222-235
    • /
    • 2015
  • Samples were collected from both places including the coastal area within the height of 5 m above the mean sea level (msl) (DH) and the top of the coastal terrace of 10-15 m msl (KS) high in Gwangseungri, Gochanggun, Korea. To find the origin of the deposit in the coastal area, granulometric analysis and geochemical analysis were performed. The result showed that the DH samples were originated from the reddish soils overlaying weathered bedrock which presented gradual change of chemical composition from the bottom toward the top. Clay minerals were found from the DH samples. These results concluded that the DH samples were found as in-situ weathered materials. The KS samples were originated from the soil layer covering gravel layer at the foot slope of the hill along the coast. The KS samples contained different chemical compositions from the DH. It is inferred that some of this layer was disturbed or experienced the influx of foreign material. The particle size of the KS samples was different from those found on the beach. The particle size of lower parts of KS site was finer than that on the beach, but the particle size of middle part of the site was coarser than that on the beach. The sorting of the KS site was poorer than that on the beach. Thus, it is inferred that some parts of the layer were formed by short-lived high energy event rather than sustained and continuous action of tidal currents and/or waves. Analysis using an optically stimulated luminescence (OSL) method showed that the burial age of samples from KS site were found 0.65-0.71 ka. Though the characteristics of the sediment layer and forming event in this area should be further studied, it can be inferred that this sedimentary layer formed by coastal flooding with storm.

Evaluations and Comparisons of Body Surface Doses during Breast Cancer Treatment by Tomotherapy and LINAC Radiotherapy Devices

  • Lee, Hyun-Jik;Bae, Sun-Hyun;Cho, Kwang Hwan;Jeong, Jae-Hong;Kwon, Su-Il;Lee, Kil-Dong
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.218-225
    • /
    • 2017
  • Effects on skin caused by the dose from linear accelerator (LINAC) opposing portal irradiation and TomoDirect 3-D modeling treatment according to the radiation devices and treatment methods were measured, and a comparative analysis was performed. Two groups of 10 patients each were created and measurements were carried out using an optically stimulated luminescence dosimeter. These patients were already receiving radiation treatment in the hospital. Using the SPSS statistical program, the minimum and maximum average standard deviations of the measured skin dose data were obtained. Two types of treatment method were selected as independent variables; the measured points and total average were the dependent variables. An independent sample T-test was used, and it was checked whether there was a significance probability between the two groups. The average of the measured results for the LINAC opposing portal radiation was 117.7 cGy and PDD 65.39% for the inner breast, 144.7 cGy and PDD 80.39% for the outer breast, 143.2 cGy and PDD 79.56% for the upper breast, 151.4 cGy and PDD 84.11% for the lower breast, 149.6 cGy and PDD 83.11% for the axilla, and 141.32 cGy and PDD 78.51% for the total average. In contrast, for TomoDirect 3-D conformal radiotherapy, the corresponding measurement values were 137.6 cGy and PDD 76.44%, 152.3 cGy and PDD 84.61%, 148.6 cGy and PDD 82.56%, 159.7 cGy and PDD 88.72%, and 148.6 cGy PDD 82.56%, respectively, and the total average was 149.36 cGy and PDD 82.98%. To determine if the difference between the total averages was statistically significant, the independent sample T-test of the SPSS statistical program was used, which indicated that the P-value was P=0.024, which was 0.05 lower than the significance level. Thus, it can be understood that the null hypothesis can be dismissed, and that there was a difference in the averages. In conclusion, even though the treatment dose was similar, there could be a difference in the dose entering the body surface from the radiation treatment plan; however, depending on the properties of the treatment devices, there is a difference in the dose affecting the body surface. Thus, the absorbed dose entering the body surface can be high. During breast cancer radiotherapy, radiation dermatitis occurs in almost all patients. Most patients have a difficult time while undergoing treatment, and therefore, when choosing a radiotherapy treatment method, minimizing radiation dermatitis is an important consideration.

Evaluation of Reductive Effect of Exposure Dose by Using Air Gap Apron in Nuclear Medicine Related Work Environment (핵의학과 내 작업 환경에서 공기층 납치마의 피폭선량 감소 효과 평가)

  • Lee, Wang-Hui;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.12
    • /
    • pp.845-853
    • /
    • 2014
  • In this study, we measured the dose reaching the OSLD dosimeter by using the regular lead apron, and air gap apron through 3 experiments, and researched the reductive effect of air gap apron on exposure dose based on the 140 keV gamma ray radiating from $^{99m}technetium$, which is the most commonly used in nuclear medicine. As a result, when the gap between the dosimeter and 0.2mm lead plate is 0 Cm, the average value of 10 dosimeters was 0.515 mSv, and when the gap between the dosimeter and lead plate is 20 Cm, the average value of 10 dosimeters was 0.138 mSv, which shows reductive effect of dose as much as 0.388 mSv. When the gap between the dosimeter and 0.5mm lead plate is 0 Cm, the average value of 10 dosimeters was 0.296 mSv, and when the gap between the dosimeter and lead plate is 20 Cm, the average value of 10 dosimeters was 0.075 mSv, which shows reductive effect of dose as much as 0.221 mSv. As we check the cumulative dosage for 3 days, the lead apron without air layer shows average 0.239 mSv, and the air gap apron shows 0.176 mSv, which is actually reduced by 0.062 mSv. As we check the cumulative dosage for a month, the lead apron without air layer shows 0.59 mSv, and the air gap apron shows 0.54 mSv, which is reduced by 0.05 mSv.

Caregiver or Family Doses due to Discharged $^{131}I$ Administrated Patient from the Hospital (고용량 $^{131}I$ 투여환자 퇴원이후 환자 간병인과 환자 가옥의 피폭선량 측정)

  • Jeong, Gyu-Hwan;Lee, Hyun-Kook;Cho, Woon-Kap;Lee, Jai-Ki
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.149-154
    • /
    • 2010
  • Exposed doses to the patient's caregiver and their house due to the 131I from patients discharged from the hospital were measured using OSL dosimeters. Usually, 3.37-5.55 GBq (100-150 mCi) of $^{131}I$ administrated patients are discharged from the hospital after 3 or 4 days of hospitalization in Korea. In addition, after 5 to 8 days, the accumulated doses of the patient's caregiver and house after hospitalization of the patient were measured using OSL dosimeters. The results of the measured average accumulated doses were 0.1 mSv, which is 10% of 1 mSv, the public dose limit in the Korean Atomic Energy Law. And it's standard deviation was 0.087 mSv. Based on the results of this study, we anticipate that we could assure the compliance of the regulation requirement 5 mSv of MEST (Ministry of Education, Science and Technology) Notice No. 2008-45 for the patient's caregiver or family, even if we reduce the 3-4 days of hospitalization to 1-2 days or less.

Prediction of Midline Dose from Entrance and Exit Dose Using OSLD Measurements for Total Body Irradiation

  • Choi, Chang Heon;Park, Jong Min;Park, So-Yeon;Chun, Minsoo;Han, Ji Hye;Cho, Jin Dong;Kim, Jung-in
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.2
    • /
    • pp.77-82
    • /
    • 2017
  • Background: This study aims to predict the midline dose based on the entrance and exit doses from optically stimulated luminescence detector (OSLD) measurements for total body irradiation (TBI). Materials and Methods: For TBI treatment, beam data sets were measured for 6 MV and 15 MV beams. To evaluate the tissue lateral effect of various thicknesses, the midline dose and peak dose were measured using a solid water phantom (SWP) and ion chamber. The entrance and exit doses were measured using OSLDs. OSLDs were attached onto the central beam axis at the entrance and exit surfaces of the phantom. The predicted midline dose was evaluated as the sum of the entrance and exit doses by OSLD measurement. The ratio of the entrance dose to the exit dose was evaluated at various thicknesses. Results and Discussion: The ratio of the peak dose to the midline dose was 1.12 for a 30 cm thick SWP at both energies. When the patient thickness is greater than 30 cm, the 15 MV should be used to ensure dose homogeneity. The ratio of the entrance dose to the exit dose was less than 1.0 for thicknesses of less than 30 cm and 40 cm at 6 MV and 15 MV, respectively. Therefore, the predicted midline dose can be underestimated for thinner body. At 15 MV, the ratios were approximately 1.06 for a thickness of 50 cm. In cases where adult patients are treated with the 15 MV photon beam, it is possible for the predicted midline dose to be overestimated for parts of the body with a thickness of 50 cm or greater. Conclusion: The predicted midline dose and OSLD-measured midline dose depend on the phantom thickness. For in-vivo dosimetry of TBI, the measurement dose should be corrected in order to accurately predict the midline dose.

Volcanological History of the Baengnokdam Summit Crater Area, Mt. Halla in Jeju Island, Korea (제주도 한라산 백록담 일대의 화산활동사)

  • Ahn, Ung San;Hong, Sei Sun
    • The Journal of the Petrological Society of Korea
    • /
    • v.26 no.3
    • /
    • pp.221-234
    • /
    • 2017
  • The Baengnokdam, the summit crater of Mt. Halla, is one of the representative geosites of World Natural Heritage and Global Geopark in Jeju Island. The crater is marked by two distinctive volcanic lithofacies that comprise: 1) a trachytic lava dome to the west of the crater and 2) trachybasaltic lava flow units covering the gentle eastern slope of the mountain. This study focuses on understanding the formative process of this peculiar volcanic lithofacies association at the summit of Mt. Halla through field observation and optically stimulated luminescence (OSL) dating of the sediments underlying the craterforming volcanics. The trachyte dome to the west of the crater is subdivided into 3 facies units that include: 1) the trachyte breccias originating from initial dome collapse, 2) the trachyte lava-flow unit and 3) the domal main body. On the other side, the trachybasalt is subdivided into 2 facies units that include: 1) the spatter and scoria deposit from the early explosive eruption and 2) lava-flow unit from the later effusion eruption. Quartz OSL dating on the sediments underlying the trachyte breccias and the trachybasaltic lava-flow unit reveals ages of ca. 37 ka and ca. 21 ka, respectively. The results point toward that the Baengnokdam summit crater was formed by eruption of trachybasaltic magma at about 19~21 ka after the trachyte dome formed later than 37 ka.

Evaluation of OSLD and EBT3 film for dose, energy, and angular dependence (OSLD와 EBT3 필름의 선량, 에너지, 방향의존성에 대한 평가)

  • Lee, Ju-seong;Kang, Bo-ram;Kwon, Hyeon-Kyung;Park, Ji-Young;Kim, Ju-Hye;Choi, Young-Se;Kim, Daehong
    • The Korean Journal of Food & Health Convergence
    • /
    • v.4 no.1
    • /
    • pp.15-22
    • /
    • 2018
  • A radiation dosimeter is important to assess quality assurance (QA) of radiation therapy devices and to estimate the radiation dose in vivo dosimetry. Recently, optically stimulated luminescence detector (OSLD) is widely used in clinical filed. Therefore, the purpose of this study is to evaluate dose, energy, and angular dependence of OSLD and EBT3 film. The absorbed dose in clinical linear accelerator (Linac) beam is calibrated for dose per monitor unit (MU). Dose, energy, and angular dependence of OSLD and EBT3 film are estimated after the calibration procedure. The absorbed dose is measured at 50, 100, 150, and 200 cGy in an 6 MV X-ray beam for dose dependence. A dose of 150 cGy is delivered to OSLD and EBT3 film with 6 and 10 MV photon energies for energy dependence. For measurements of angular dependence, angular positions of gantry are $0^{\circ}{\pm}80^{\circ}$ with 6 MV at 150 cGy. The results of dose dependence is linear for OSLD and EBT3 film. For the results of energy dependence, errors were 0.39% and 0.03% for OSLD and EBT3 film, respectively. The results of dose for angular is decreased from $0^{\circ}$ to ${\pm}80^{\circ}$ for both OSLD and EBT3 film. When angle of $0^{\circ}$ is normalized to 1, and the dose is decreased to 60 and 66% at $80^{\circ}$ for OSLD and EBT3 film, respectively. Dose and energy dependence of OSLD and EBT3 film are measured within the recommendation of manufacturer. Angular dependence is increased from $0^{\circ}$ to ${\pm}80^{\circ}$ for OSLD and EBT3 film. The characteristics of OSLD and EBT3 film are similar and expected to useful for clinical field.