• Title/Summary/Keyword: Optical system

Search Result 6,942, Processing Time 0.035 seconds

Characteristics of the SAR Images and Interferometric Phase over Oyster Sea Farming Site (굴 양식장에서의 SAR 영상 및 간섭위상 특성)

  • 김상완;이창욱;원중선
    • Korean Journal of Remote Sensing
    • /
    • v.18 no.4
    • /
    • pp.209-220
    • /
    • 2002
  • We carried out studies on SAR image intensity and interferometric phase over oyster sea farms. Strong backscattering was observed in amplitude images, and that was considered as a radar signal double bouncing from horizontal bars. These sea farming structures are not visible in satellite optical images except IKONOS image, so that it demonstrates the value of radar remote sensing as an effective tool in support of sea farm detection. The intensity of the image is sensitive to system parameters including wavelength, polarization, and look direction, but does not correlate to tide height. We found that the strongest backscattering can be obtained by L-band HH-polarization with a look direction perpendicular to the horizontal bar. We also succeeded in generating 21 coherent JERS-1 SAR interferometric pairs over the oyster farms. The general trend of the fringe rate of the interferometric phases appeared to be governed by altitude of ambiguity. The general trend was modeled by an inverse function and removed to have a residual phase. The residual phase showed a linear relation with the tide height. The results demonstrate for the first time that SAR can possibly be used to estimate sea level. However, the r.m.s. error of a regression line is 11.7 cm, and that is so far too large to make reliable assessments of sea level in practical applications. Further studies is required to improve the accuracy specifically using multi-polarization SAR data.

Difference between Collection 4 and 5 MODIS Aerosol Products and Comparison with Ground based Measurements (Collection 4 와 Collection 5 MODIS 에어러솔 분석 자료의 차이와 지상관측자료와의 비교)

  • Lee, Kwon-Ho;Kim, Young-Joon
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.4
    • /
    • pp.369-379
    • /
    • 2008
  • The aerosol retrieval algorithm for the Moderate Resolution Imaging Spectroradiometer (MODIS) measurements was updated recently. This paper reports on the comparison and validation of two latest versions (Collection 4 and 5, shortly C004 and C005) of the MODIS aerosol product over northeast Asian region. The differences between the aerosol optical thickness (AOT) from the C004 and C005 retrieval algorithms and the correlation with ground based AERONET sunphotometer observations are investigated. Over the study region, spatially averaged annual mean AOT retrieved from C005 algorithm $(AOT_{C005})$ is about 0.035 AOT (5%) less than the C004 counterparts. The linear correlations between MODIS and AERONET AOT also are R=0.89 (slope=0.86) for the C004 and R=0.95 (slope=1.00) for the C005. Moreover, the magnitude of the mean error in $AOT_{C005}$, difference between MODIS AOT and AERONET AOT, is 40% less than that in $AOT_{C004}$.

Linewidth Reduction of a Yellow Laser by a Super-cavity and the Measurement of the Cavity Finesse (초공진기를 이용한 노란색 레이저의 선폭 축소 및 초공진기의 예리도 측정)

  • Lee, Won-Kyu;Park, Chang-Yong;Park, Sang-Eon;Ryu, Han-Young;Yu, Dai-Hyuk;Mun, Jong-Chul;Suh, Ho-Suhng
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.3
    • /
    • pp.123-128
    • /
    • 2010
  • Sum frequency generation was utilized to obtain a yellow laser with the wavelength of 578.4 nm for a probe laser of an Yb lattice clock. The output of an Nd:YAG laser with wavelength of 1319 nm and that of an Yb-fiber laser with wavelength of 1030 nm were passed through a waveguided periodically-poled lithium niobate (WG-PPLN) for sum frequency generation. It is required that the probe laser has a linewidth of the order of 1 Hz to fully resolve the Yb lattice clock transition. Thus, the linewidth of the probe laser was reduced by stabilizing the frequency to a super-cavity. This was made of ULE with a low thermal expansion coefficient, and was mounted on an active vibration-isolation table at the optimal point for the reduced sensitivity to vibration. Also, this was installed in a vacuum chamber, and the temperature was stabilized to 1 mK level. This system was installed in an acoustic enclosure to block acoustic noise. The finesse of the super-cavity was measured to be 380 000 from the photon life time of the cavity.

The Effects of Fibular Repositioning Taping on Joint Angle and Joint Stiffness of the Lower Extremity in Sagittal Plane during a Drop Landing (낙하 착지 시 FRT가 하지의 관절의 시상각과 강직도에 미치는 효과)

  • Jun, Hyung-pil
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.4
    • /
    • pp.276-282
    • /
    • 2021
  • Objective: To investigate effects of Fibular Repositioning Taping (FRT) on lower extremity joint stiffness and angle during drop-landing. Method: Twenty-eight participants (14 healthy, 14 with chronic ankle instability [CAI]) performed drop-landings from a 60 cm box; three were performed prior to tape application and three were performed post-FRT. Three-dimensional kinematic and kinetic data were collected using an infrared optical camera system (Vicon Motion Systems Ltd. Oxford, UK) and force-plate (AMTI, Watertown, MA). Joint stiffness and sagittal angle of the ankle, knee, and hip were analyzed. Results: The hip [Healthy: p<.05; M ± SD: 29.43 ± 11.27 (pre), 33.04 ± 12.03 (post); CAI: p<.05; M ± SD: 31.45 ± 9.70 (pre), 32.29 ± 9.85 (post)] and knee [Healthy: p<.05; M ± SD: 53.44 ± 8.09 (pre), 55.13 ± 8.36 (post); CAI: p<.05; M ± SD: 53.12 ± 8.35 (pre), 55.55 ± 9.81 (post)] joints demonstrated significant increases in sagittal angle after FRT. A significant decrease in joint angle was found at the ankle [Healthy: p<.05; M ± SD: 56.10 ± 3.71 (pre), 54.09 ± 4.31 (post); CAI: p<.05; M ± SD: 52.80 ± 6.04 (pre), 49.86 ± 10.08 (post)]. A significant decrease in hip [Healthy: p<.05; M ± SD: 1549.16 ± 517.53 (pre), 1272.48 ± 646.73 (post); CAI: p<.05; M ± SD: 1300.42 ± 595.55 (pre), 1158.27 ± 550.58 (post)] and knee [Healthy: p<.05; M ± SD: 270.12 ± 54.07 (pre), 239.13 ± 64.70 (post); CAI: p<.05; M ± SD: 241.58 ± 93.48 (pre), 214.63 ± 101.00 (post)] joint stiffness was found post-FRT application, while no difference was found at the ankle [Healthy: p>.05; M ± SD: 57.29 ± 17.04 (pre), 59.37 ± 18.30 (post); CAI: p>.05; M ± SD: 69.15 ± 17.63 (pre), 77.24 ± 35.05 (post)]. Conclusion FRT application decreased joint angle at the ankle without altering ankle joint stiffness. In contrast, decreased joint stiffness and increased joint angle was found at the hip and knee following FRT. Thus, participants utilize an altered shock absorption mechanism during drop-landings following FRT. When compared to previous research, the joint kinematics and stiffness of the lower extremity appear to be different following FRT versus traditional ankle taping.

A Study on Non-uniformity Correction Method through Uniform Area Detection Using KOMPSAT-3 Side-Slider Image (사이드 슬리더 촬영 기반 KOMPSAT-3 위성 영상의 균일 영역 검출을 통한 비균일 보정 기법 연구 양식)

  • Kim, Hyun-ho;Seo, Doochun;Jung, JaeHeon;Kim, Yongwoo
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_1
    • /
    • pp.1013-1027
    • /
    • 2021
  • Images taken with KOMPSAT-3 have additional NIR and PAN bands, as well as RGB regions of the visible ray band, compared to imagestaken with a standard camera. Furthermore, electrical and optical properties must be considered because a wide radius area of approximately 17 km or more is photographed at an altitude of 685 km above the ground. In other words, the camera sensor of KOMPSAT-3 is distorted by each CCD pixel, characteristics of each band,sensitivity and time-dependent change, CCD geometry. In order to solve the distortion, correction of the sensors is essential. In this paper, we propose a method for detecting uniform regions in side-slider-based KOMPSAT-3 images using segment-based noise analysis. After detecting a uniform area with the corresponding algorithm, a correction table was created for each sensor to apply the non-uniformity correction algorithm, and satellite image correction was performed using the created correction table. As a result, the proposed method reduced the distortion of the satellite image,such as vertical noise, compared to the conventional method. The relative radiation accuracy index, which is an index based on mean square error (RA) and an index based on absolute error (RE), wasfound to have a comparative advantage of 0.3 percent and 0.15 percent, respectively, over the conventional method.

Distribution of Surface Solar Radiation by Radiative Model in South Korea (복사 모델에 의한 남한의 지표면 태양광 분포)

  • Zo, Il-Sung;Jee, Joon-Bum;Lee, Won-Hak;Lee, Kyu-Tae;Choi, Young-Jean
    • Journal of Climate Change Research
    • /
    • v.1 no.2
    • /
    • pp.147-161
    • /
    • 2010
  • The temporal and spatial distributions of surface solar radiation were calculated by the one layer solar radiative transfer model(GWNU) which was corrected by multi layer Line-by-Line(LBL) model during 2009 in South Korea. The aerosol optical thickness, ozone amount, cloud fraction and total precipitable water were used as the input data for GWNU model run and they were retrieved from Moderate Resolution Imaging Spectrometer(MODIS), Ozone Monitoring Instrument(OMI), MTSAT-1R satellite data and the Regional Data Assimilation Prediction System(RDAPS) model result, respectively. The surface solar radiation was calculated with 4 km spatial resolution in South Korea region using the GWNU model and the results were compared with surface measurement(by pyranometer) data of 22 KMA solar sites. The maximum values(more than $5,400MJ/m^2$) of model calculated annual solar radiation were found in Andong, Daegu and Jinju regions and these results were corresponded with the MTSAT-1R cloud amount data. However, the spatial distribution of surface measurement data was comparatively different from the model calculation because of the insufficient correction and management problems for the sites instruments(pyranometer).

Development of Indoor Navigation System based on the Augmented Reality in Subway Station (증강현실 기반 지하철 역사의 보행안내 시스템)

  • KIM, Wongil;LIM, Guk hyun;KIM, Hyun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.1
    • /
    • pp.43-55
    • /
    • 2019
  • Smart phone based navigation applications are very useful in everyday life. Cost-effective and user friendly navigation can be provided to the user by many applications available in market. Using the Smart phone these navigation applications provide accurate navigation for outdoor locations. But providing an accurate navigation underground space such as subway station is still a challenge. It is hence more convenient and appropriate for mobility services if the visitors could simply view the guidance of the subway station on their mobile phone, wherever and whenever it is needed. This study develops a algorithm for indoor navigation with the help of Augmented Reality(AR) and QR marker code from the entrance to the train platform for users. This indoor navigation uses AR and QR maker codes for two purposes: to provide the user link to the subway station location and to provide the current guidance details to the user. This Smart phone algorithm that uses a smart phone optical tool to decode the QR marker to determine the location information and provide guidance to the AR without indoor Maps. This algorithm also provides a module to guide mobility vulnerable to the Barrier Free route to destination.

Analysis of Quality Improvement of a Floating Image Using a Hybrid Retroreflective Mirror Array Sheet (혼성-병풍형 구조의 재귀반사 거울 배열판을 이용한 부양영상 개선 분석)

  • Yu, Dong Il;Baek, Young Jae;Yong, Hyeon Joong;O, Beom Hoan
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.4
    • /
    • pp.142-145
    • /
    • 2019
  • Normally, a corner cube retroreflector (CCRR) sheet is used as a retroreflective mirror array (RRMA) in a volumetric display. Each CCRR unit reflects light in the retroreflective direction, which is parallel to the incident light, and it makes a blurred image, as it shifts the position of light within its dimensions. Adopting a "curved planar wall" and "parabolic focusing" (x-axis), a hybrid-t(transverse direction)-RRMA is proposed, to improve the image quality and brightness. The improvement of image contrast is achieved by tuning a "linear v-shaped groove" structure to a "parabolic v-shaped groove". Also, the system has been simplified and the brightness enhanced 4 times by removing the half mirror.

Effect of milling tool wear on the internal fit of PMMA implant interim prosthesis (밀링 공구의 마모가 PMMA 임플란트 임시보철물 변연 및 내면적합도에 미치는 영향)

  • Shin, Mi-sun
    • Journal of Technologic Dentistry
    • /
    • v.41 no.2
    • /
    • pp.63-69
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the effect of CAD/CAM system milling tool wear on the marginal and internal fit of PMMA implant interim prosthesis three-dimensional manner. Methods: A total of 20 crowns were fabricated with CAD/CAM method. Their designs were unified to first molar of the left maxilla. The Customized abutments were prepared and scanned with on optical model scanner. Five crowns were milled by the newly replaced tool (1st milling), and 15 crowns were milled by 2nd, 3rd, 4th milling tool. The marginal and internal fit of 20 interim crowns were measured using the triple-scan protocol. Results: Statistically significant difference was found between the $1^{st}$ milling group ($51.8{\pm}14.6{\mu}m$) and the $3^{rd}$, $4^{th}$ milling group ($128.6{\pm}43.8{\mu}m$, $146.2{\pm}38.1{\mu}m$, respectively) at the distal margins. In the mesial margins, There was a statistically significant difference between the $1^{st}$ milling group ($63.6{\pm}25.9{\mu}m$) and the $3^{rd}$, $4^{th}$ milling group ($137.2{\pm}25.9{\mu}m$, $186.8{\pm}70.6{\mu}m$, respectively). In the distal line angle, significant difference was found between the $1^{st}$, $2^{nd}$, $3^{rd}$ milling groups and the $4^{th}$ milling group. In the mesial axial wall, significant difference was found between the $1^{st}$ milling group ($52.2{\pm}20.3{\mu}m$) and the $3^{rd}$, $4^{th}$ milling groups ($22.8{\pm}8.8{\mu}m$, $7.8{\pm}5.7{\mu}m$). Conclusion: As a result of the experiment, decrease of the marginal and internal fit was statistically significant as the number of machining cycles increased. In order to produce clinically excellent restorations, it is recommandable to consider the condition of the milling tool wear, when designing the restoration with CAD program.

A Study on Technological Forecasting for Promising Alternative Technologies Using Fisher-Pry Modification Model (Fisher-Pry 수정모형을 활용한 유망대체기술 예측에 관한 연구)

  • Hong, Sung-Il;Kim, Byung-Nam
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.5
    • /
    • pp.104-114
    • /
    • 2019
  • In the global market competition, countries and businesses are actively engaged in technology prediction activities to maximize their profits by attempting to enter and preempting the core technology of the future. In this paper, we propose a growth model based on patent application trends to predict the time to replace a product with a promising new technology to dominate the market. Although the Fisher-Pry model that Bhargava generalized to predict the emergence of promising alternative technologies was relatively satisfactory compared to the original Fisher-Pry model, it was difficult to predict the replacement rate behavior properly due to a parameter problem. The application of the Fisher-Pry Modification Model in the form of a quadratic equation through the patent trend analysis of the optical storage system for the purpose of verifying the time alternative to the light storage technology has resulted in satisfactory verification results. It is expected that small and medium-sized companies and individual researchers will apply this model and use it more easily to predict the time to replace the market for promising replacement technologies.