• 제목/요약/키워드: Optical scanner

검색결과 165건 처리시간 0.021초

3차원 부품 레이저 용접용 스캐너 광학 최적설계 (Optimization of Optics Design for 3D Laser Scanner)

  • 최해운
    • 한국기계가공학회지
    • /
    • 제19권6호
    • /
    • pp.96-101
    • /
    • 2020
  • In this paper, we present the results of our research to perform 3D laser scanning functions by adding a focusing lens to a conventional 2D laser scanner. For the optical design, the ray-tracing technique was used along with a total of four lenses as the variable incident focusing lens, the collimating lens, and the F-Theta lens. As design variables, the curvature of the incident focusing lens (Lens #1) was assumed to be us, l mm and sumed mm, and the incident angles were set at 0cidenus, l. In addition, the distance between the focusing lens and the collimating lens was set to vary from 5 mm to 15 mm. When the incident focal length was varied from 5 mm to 15 mm, the exit focal length was calculated to vary from 67.5 mm to 56.8 mm for the lens with R = 100 mm and from 108.5 mm to 99.0 mm for the lens with R = 150 mm. When the incident angle was 0°, the focal aberration was only slightly observable at 10㎛ in both the x- and y-direction. At 7.5° was the focal aberration of approximately 20~50㎛ was measured at 20㎛. To investigate the chromatic aberration of the designed optical device, the distortion of the focus was observed when the 550 nm beam was simulated on lens designed for a 980 nm wavelength.

Development of Color 3D Scanner Using Laser Structured-light Imaging Method

  • Ko, Youngjun;Yi, Sooyeong
    • Current Optics and Photonics
    • /
    • 제2권6호
    • /
    • pp.554-562
    • /
    • 2018
  • This study presents a color 3D scanner based on the laser structured-light imaging method that can simultaneously acquire 3D shape data and color of a target object using a single camera. The 3D data acquisition of the scanner is based on the structured-light imaging method, and the color data is obtained from a natural color image. Because both the laser image and the color image are acquired by the same camera, it is efficient to obtain the 3D data and the color data of a pixel by avoiding the complicated correspondence algorithm. In addition to the 3D data, the color data is helpful for enhancing the realism of an object model. The proposed scanner consists of two line lasers, a color camera, and a rotation table. The line lasers are deployed at either side of the camera to eliminate shadow areas of a target object. This study addresses the calibration methods for the parameters of the camera, the plane equations covered by the line lasers, and the center of the rotation table. Experimental results demonstrate the performance in terms of accurate color and 3D data acquisition in this study.

갈바노미터 스캐너를 이용한 레이저 마킹 시스템 설계 제작에 관한 연구 (A study on the design of the laser marking system using galvanometer scanner)

  • 조태익;이건이
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1986년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 17-18 Oct. 1986
    • /
    • pp.145-148
    • /
    • 1986
  • To perform the marking on metal with high speed and non-contact using the laser beam of high energy, laser marking system is designed and fabricated applying the galvanometer scanner capable of high speed-precise beam positioning controlled by microprocessor. Laser is a Q-switched Nd:YAG producing multi-mode, wavelength, 1060nm. Optical system is composed of beam expander, scanning mirror and flat field lens. Consequently, the laser marking is satisfactorily achieved regardless of kinds of metal.

  • PDF

광삼각법을 이용한 비접촉 3차원 족형 측정 시스템 설계 (Development of a Noncontact Three Dimensional Foot Form Measurement System with Optical Triangulation)

  • 박인덕;안형회;송강석;이희만;김시경
    • 제어로봇시스템학회논문지
    • /
    • 제9권5호
    • /
    • pp.368-373
    • /
    • 2003
  • This paper presents a cost-effective 3D foot scanner system that provides the 3-dimensional point cloud foot data to design the custom footwear. To measure the 3-dimensional point cloud data of the foot, a CCD camera, a Non-Gaussian laser line projector and optical triangulation method are employed. Furthermore, the integrated system employs a measurement base, a frame grabber, a CCD moving cart, a stepping motor and a computer. The measurement result is saved as 3D dxf format and it could be converted to 2D essential data fer a shoe design. The experimental results demonstrate that the proposed system have the decent resolution of 1mm which is enough for last and shoe design.

직병렬 주사방식 일정장비의 신호처리기 설계 연구 (Electronic Processor Design for Thermal Imager with Serial/Parallel Scan type)

  • 송인섭;유위경;윤은석;홍영철;홍석민
    • 전자공학회논문지B
    • /
    • 제31B권1호
    • /
    • pp.49-56
    • /
    • 1994
  • This paper describes the design principles and methods of electronic processor for thermal imager with the SPRITE detector, operating in the 8-12 micron band. The thermal imager consists of a optical scanner containing the detector and an electrical signal processor. The optical scanner utilizing rotating polygon and oscillating mirror, is 2-dimensional serial/parallel scan type using 5 elements of the detector. And the electronic processor has pre-processing of 5 chnanel's thermal signal from the detector, and performs digital scan conversion to reform the parallel data stream into serial analog data compatible with conventional RS-170 video. Through the designed electronic processor, we have acquired a satisfactory thermal image. And the MRTD (Minimum Resolvable Temperature Difference) is 0.5$^{\circ}$K at 7.5 cycles/mm.

  • PDF

Accuracy of virtual models in the assessment of maxillary defects

  • Kamburoglu, Kivanc;Kursun, Sebnem;Kilic, Cenk;Ozen, Tuncer
    • Imaging Science in Dentistry
    • /
    • 제45권1호
    • /
    • pp.23-29
    • /
    • 2015
  • Purpose: This study aimed to assess the reliability of measurements performed on three-dimensional (3D) virtual models of maxillary defects obtained using cone-beam computed tomography (CBCT) and 3D optical scanning. Materials and Methods: Mechanical cavities simulating maxillary defects were prepared on the hard palate of nine cadavers. Images were obtained using a CBCT unit at three different fields-of-views (FOVs) and voxel sizes: 1) $60{\times}60mm$ FOV, $0.125mm^3$ ($FOV_{60}$); 2) $80{\times}80mm$ FOV, $0.160mm^3$ ($FOV_{80}$); and 3) $100{\times}100mm$ FOV, $0.250mm^3$ ($FOV_{100}$). Superimposition of the images was performed using software called VRMesh Design. Automated volume measurements were conducted, and differences between surfaces were demonstrated. Silicon impressions obtained from the defects were also scanned with a 3D optical scanner. Virtual models obtained using VRMesh Design were compared with impressions obtained by scanning silicon models. Gold standard volumes of the impression models were then compared with CBCT and 3D scanner measurements. Further, the general linear model was used, and the significance was set to p=0.05. Results: A comparison of the results obtained by the observers and methods revealed the p values to be smaller than 0.05, suggesting that the measurement variations were caused by both methods and observers along with the different cadaver specimens used. Further, the 3D scanner measurements were closer to the gold standard measurements when compared to the CBCT measurements. Conclusion: In the assessment of artificially created maxillary defects, the 3D scanner measurements were more accurate than the CBCT measurements.

레이저 빔 스캔 시스템의 Blur현상 개선 (The Improvement of Blur Phenomenon at Laser Beam Scanner)

  • 노진기;김혜진;김갑일
    • 전기학회논문지
    • /
    • 제63권9호
    • /
    • pp.1281-1285
    • /
    • 2014
  • Recently, as the wide spread of smart phone, pico projector which is used at the smart phone is appeared as a portable display device. In this paper, among several pico projectors, laser beam scanner module is dealt with in which laser is used as light source, and mems-mirror is used as optical panel. In this device, screen image quality is a special issue, and blur effect is a typical adverse effect to the quality of this device. So the enhancement of this blur effect has an important factor of the quality of the device. The definition of the blur and the main source of the blur are studied and the simulation results and way of improvement are also suggested.

서브나노급 정밀도의 2 차원 원자현미경 개발 (Two Dimensional Atomic Force Microscope)

  • 이동연;권대갑
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1778-1783
    • /
    • 2008
  • A compact and two-dimensional atomic force microscope (AFM) using an orthogonal sample scanner, a calibrated homodyne laser interferometer and a commercial AFM head was developed for use in the nanometrology field. The x and y position of the sample with respect to the tip are acquired by using the laser interferometer in the open-loop state, when each z data point of the AFM head is taken. The sample scanner which has a motion amplifying mechanism was designed to move a sample up to $100{\times}100{\mu}m^2$ in orthogonal way, which means less crosstalk between axes. Moreover, the rotational errors between axes are measured to ensure the accuracy of the calibrated AFM within the full scanning range. The conventional homodyne laser interferometer was used to measure the x and y displacements of the sample and compensated via an X-ray interferometer to reduce the nonlinearity of the optical interferometer. The repeatability of the calibrated AFM was measured to sub-nm within a few hundred nm scanning range.

  • PDF

Optical Coherence Tomography Applications for Dental Diagnostic Imaging: Prototype System Performance and Preclinical Trial

  • Eun Seo Choi;Won-Jin Yi;Chang-Seok Kim;Woosub Song;Byeong-il Lee
    • Current Optics and Photonics
    • /
    • 제7권3호
    • /
    • pp.283-296
    • /
    • 2023
  • An intraoral spectral domain optical coherence tomography (SD-OCT) system has been developed, using a custom-built hand-held scanner and spectrometer. The hand-held OCT probe, based on a microelectromechanical systems scanner and a self-built miniaturized drive circuit, had a field of view sufficient for dental diagnosis. The spectrometer using a fabricated f-theta lens provided the image depth required for dental diagnosis. The axial and transverse resolutions of the OCT system in air were 7.5 ㎛ and 12 ㎛ respectively. The hand-held probe could scan an area of 10 × 10 mm2, and the spectrometer could image along a depth of 2.5 mm. To verify the utility of the developed OCT system, OCT images of tooth hard and soft tissues were acquired, and a user-interface program for diagnosis was developed. Early caries and microcracks that were difficult to diagnose with existing methods could be found, and the state of restoration could be observed. Measuring the depth of the gingival sulcus, distinguishing subgingival calculus, and detecting an implant under the gingiva suggested the possibility of the SD-OCT system as a diagnostic for dental soft tissues. Through the presented OCT images, the capability of the developed SD-OCT system for dental diagnosis was demonstrated.

다중 회귀분석법을 이용한 스캐너-모니터간 색보정에 관한 연구 (A study on the color management between scanner and monitor using multiple regression method)

  • 박진희;김홍석;박승옥
    • 한국광학회지
    • /
    • 제14권4호
    • /
    • pp.473-479
    • /
    • 2003
  • 본 연구는 스캔된 이미지의 원본색이 모니터에 그대로 디스플레이 될 수 있게 하는 것을 목적으로 한다. 색보정 과정은 스캐너의 색 특성 묘사를 통한 원본색의 XYZ 추정, 기준 광원의 차이를 고려한 XYZ 변환, XYZ와 RGB간의 색공간 변환으로 구성된다. 특히, XYZ 추정에 있어서 스캐너에 입사되는 빛의 세기와 출력신호간의 비선형적 관계를 두 구간으로 나누어 묘사함으로써 그 정확도를 높였다 EPSON Expression 1680 스캐너를 대상으로 실시한 결과, 228가지 기준색의 기준값과 추정값의 평균 색차는 1.47 $\Delta$ $E_{UV}$ * 이었으며, 36가지의 유채색과 22가지의 무채색으로 구성된 시험색의 평균 색차가 각각 1.51 $\Delta$ $E_{UV}$ * 와 0.90 $\Delta$ $E_{UV}$ * 이었다. 또한 시험색 36가지에 대해 기준값과 추정값으로 부터 산출된 sRGB 모니터 입력신호를 동일 모니터에 디스플레이한 결과, 두 이미지의 색이 동일하게 보였다. sRGB 모니터 입력신호를 동일 모니터에 디스플레이한 결과, 두 이미지의 색이 동일하게 보였다.