• 제목/요약/키워드: Optical magnification

검색결과 110건 처리시간 0.028초

적층 두께 및 출력 각도가 수리된 3D 프린팅 의치상 레진의 굴곡강도와 표면 거칠기에 미치는 영향 (Influence of Layer Thickness and Build Angle on the Flexural Strength and Surface Roughness of Repaired 3D-Printed Denture Base Resin)

  • 최재원
    • 한국산업융합학회 논문집
    • /
    • 제27권5호
    • /
    • pp.1167-1174
    • /
    • 2024
  • The purpose of this study was to evaluate the effects of various layer thicknesses and build angles on the flexural strength and surface roughness of repaired 3D-printed denture base resin. 3D-printed bar-shaped specimens with a 45° bevel were fabricated according to layer thickness(50 ㎛ and 100 ㎛) and build angle(0-degree, 45-degree, and 90-degree). Denture relining resin was applied to the 2 mm repair area Flexural strength was measured by a three-point bending test using a universal testing machine, and surface roughness(Ra) and surface topography were observed using a digital optical microscope at ×500 magnification. Statistical significance was analyzed using two-way ANOVA, one-way ANOVA, and Games-Howell post hoc(α = .05). Except for the 90-degree group, the group with a layer thickness of 100 ㎛ showed better flexural strength values than the group with a layer thickness of 50 ㎛(p < .05). Additionally, within the same layer thickness, the 45-degree group showed the lowest flexural strength value. The Ra values of the 0-degree and 90-degree groups, where the build angle was 45° to the layer orientation, were higher at 100 ㎛ than at 5 0 ㎛ layer thickness(p < .05), and the Ra value of the 45-degree group, where the build angle was parallel to the layer orientation, was lower than those of other build angles(p < .05). Layer thickness and build angle significantly affected the surface roughness of 3D-printed denture base resin, and the surface roughness was confirmed to be closely related to the bonding strength with denture relining resin.

광섬유 다발을 이용한 다초점 현미경 (Multi-focal Microscopic System Using a Fiber Bundle)

  • 구영모;함효식;최성을
    • 한국광학회지
    • /
    • 제20권6호
    • /
    • pp.354-360
    • /
    • 2009
  • 공초점 현미경 중 하나로 각광받는 MMM(multi-focal multi-photon microscope)의 핵심부분인 미세렌즈 배열판을 광섬유 다발로 대체한 간단한 형태의 광섬유 다발 다초점 현미경을 구성하여 그 성능을 분석하였다. 이 현미경의 성능 분석을 위하여 세 종류의 시료를 사용하였으며, 두 개의 편광판과 편광 빔 분리기를 사용하여 노이즈를 제거한 뚜렷한 상을 얻을 수 있었다. 표준격자 시료를 사용하여 1차 대물렌즈의 배율을 63배와 20배로 달리하면서 광점 상의 FWHM를 구하였고, 광점 상들의 분포 속에서 물체의 상을 볼 수 있었으며, 분포가 조밀한 저배율의 1차 대물렌즈를 사용할 경우에 보다 선명한 시료의 상을 얻을 수 있었다. 광섬유 다발 다초점 현미경의 분해능을 시험하기 위해서 표준격자 시료보다 격자 간격이 작은 USAF 1951을 시료로 사용하여 상을 측정하여 얻은 시료 상의 FWHM와 주어진 시료의 선폭 값이 서로 잘 일치함을 볼 수 있었다. 광섬유 다발 다초점 현미경은 1개의 광섬유 다발을 사용함으로써 시스템을 간소화시켰고, 마이크론 이하의 분해능을 가지며, 광섬유의 개수인 1600개의 광점 상을 동시에 얻을 수 있었다.

줌 광학계를 이용한 원적외선 열상장비의 설계 및 제작 (Advanced LWIR Thermal Imaging System with a Large Zoom Optics)

  • 홍석민;김현숙
    • 한국광학회지
    • /
    • 제16권4호
    • /
    • pp.354-360
    • /
    • 2005
  • [ $480{\times}6$ ] 배열 HgCdTe(MCT) 검출기를 사용하는 고성능의 원적외선(LWIR) 줌 열상센서를 개발하였다. 광학계는 대략 190 mm 직경을 갖는 대물 망원경과 광학적으로 잘 정렬된 주사장치로 구성된다 망원경의 줌 비율은 3:1이며 배율의 변환은 2개의 렌즈 그룹을 이동시킴으로써 수행된다. 이동하는 2개의 렌즈 그룹으로 열상장비의 비열화도 함께 수행한다. 비열화 수행을 통해 광범위한 운용온도 범위에서도 시스템의 성능 저하 없이 활용이 가능하다. 한편 개발된 열상장비는 16:9 양상비를 갖는 고화질 텔레비전(HDTV)에 시현도 가능하다. HDTV 형태의 경우 주사장치는 62만 화소까지 영상 시현이 가능하다. 이 기능은 일반적인 TV 시현의 경우보다 성능의 저하 없이 수평 시계각을 넓혀 주는 역할을 한다. 설계 및 제작된 원적외선 열상장비의 고배율에서 최소분해가능온도차(MRTD)를 측정한 결과, 2 cycles/mrad의 공간주파수에서 0.04 K 이하 및 8 cycles/mrad의 공간주파수에서 0.23 K의 우수한 결과를 보였다.

치수제거 후 흰쥐 삼차신경절에서 VIP 면역반응세포의 변화: 공초점레이저주사현미경적 연구 (CHANGE OF VASOACTIVE INTESTINAL POLYPEPTIDE(VIP) IMMUNOREACTIVE CELLS FOLLOWING PULP EXTIRPATION IN RAT TRIGEMINAL GANGLION: A CONFOCAL LASER SCANNING MICROSCOPIC STUDY)

  • 김흥중;김승재;박주철;이창섭;이상호
    • 대한소아치과학회지
    • /
    • 제28권1호
    • /
    • pp.25-31
    • /
    • 2001
  • 말초신경 손상에 의한 VIP의 변화를 연구하기 위해 흰쥐 하악대구치 치수제거 후 삼차신경절에서 VIP의 분포 및 반응강도를 공초점레이저주사현미경을 이용하여 관찰하였다. 체중 200g 내외의 Sprague-Dawley계 흰쥐를 대조군과 하악대구치 치수제거 후 14일군으로 분리하여 희생시켰다. 1차 항체로 rabbit anti-VIP, 2차 항체로 fluorescein isothiocyanate(FITC) conjugated anti-rabbit IgG를 사용하여 면역형광염색을 시행한 후 공초점레이저주사현미경으로 관찰하여 다음과 같은 결론을 얻었다. 1. 삼차신경절 하악부위에서 VIP 양성반응세포의 비율은 대조군에서 7.40%를, 실험군에서는 28.42%를 보였다. 대조군에 비해 실험군에서 양성반응세포의 증가를 보였다. 2. 삼차신경절 하악부위에서 VIP면역반응세포체에 대한 상대성 형광강도는 대조군에서 87.78을, 실험군에서는 138.65를 보였다. 대조군과 비교하였을 때 실험군에서 상대성 형광강도의 증가를 보였다. 3. 실험군의 광연속절편$(1{\mu}m)$ 관찰에서 VIP면역반응세포는 9개의 절편 대부분에서 강하게 나타났다. 축삭의 면역반응을 살펴보면, 대조군의 축삭에서는 약한 반응을 보였으며, 실험군의 축삭에서는 강한 면역반응을 보였다. 또한 양성 반응 세포체의 크기는 $20\sim25{\mu}m$의 중간 크기의 세포체에서 강한 면역반응을 보였다. 위의 결과로 보아 치수제거 후에 삼차신경절 하악부위에서 VIP 면역반응세포의 증가와 함께 상대성 형광강도가 높아졌음을 알 수 있었다.

  • PDF

BS 프리즘을 이용한 주야 조준경 개발 (Development of Day and Night Scope with BS Prism)

  • 이동희
    • 한국안광학회지
    • /
    • 제19권3호
    • /
    • pp.339-344
    • /
    • 2014
  • 목적: 본 연구는 BS 프리즘의 반사면을 이용한 주야 조준경의 개발에 관한 것이다. 방법: BS(beam splitting) 프리즘의 반사면의 상하에 도트시표발생부와 LCD 패널을 배치하고, BS 프리즘 전방에는 doublet 형태로 설계된 반사경을 배치하였다. 이렇게 함으로서 도트시표 발생부에서의 도트시표 허상을 관찰자 쪽에 결상시키도록 하는 기능, 외부 목표물 주변부의 정보는 관찰자에게 1배로 보이도록 하는 기능과 LCD 패널의 영상을 직접 관찰자가 볼 수 있게 하는 기능을 가진 새로운 형태의 BS 프리즘을 이용한 주야 조준경을 개발하였다. 결과: BS 프리즘의 반사면이 도트 시표를 반사시키는 도트사이트로서의 역할과 LCD 패널에 디스플레이된 야간 열영상을 관찰자가 관찰할 수 있도록 하는 반사 광학계 역할을 하도록 함으로써 주간에는 도트사이트로서 주간조준경 기능을, 야간에는 열영상 디스플레이 장치로서 야간조준경 기능을 하는 주야 조준경 장치를 개발하였다. 결론: 본 연구에서 우리는 기존의 도트사이트와 기존의 야간조준경을 BS 프리즘을 이용하여 결합함으로서 선택적으로 주야 조준경 역할을 할 수 있는 주야 조준경을 개발하였다. 이렇게 함으로써 우리는 기존의 도트사이트와 야간조준경의 착탈식 조합보다 사격의 신속성을 더욱 높일 수 있으며 총기류에의 장착에 있어서 보다 편리함을 제공해주는 새로운 형태의 BS 프리즘을 이용한 주야 조준경을 설계 개발할 수 있었다.

The effect of additional etching and curing mechanism of composite resin on the dentin bond strength

  • Lee, In-Su;Son, Sung-Ae;Hur, Bock;Kwon, Yong-Hoon;Park, Jeong-Kil
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권4호
    • /
    • pp.479-484
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the effects of additional acid etching and curing mechanism (light-curing or self-curing) of a composite resin on the dentin bond strength and compatibility of one-step self-etching adhesives. MATERIALS AND METHODS. Sixteen human permanent molars were randomly divided into eight groups according to the adhesives used (All-Bond Universal: ABU, Clearfil S3 Bond: CS3), additional acid etching (additional acid etching performed: EO, no additional acid etching performed: EX), and composite resins (Filtek Z-250: Z250, Clearfil FII New Bond: CFNB). Group 1: ABU-EO-Z250, Group 2: ABU-EO-CFNB, Group 3: ABU-EX-Z250, Group 4: ABU-EX-CFNB, Group 5: CS3-EO-Z250, Group 6: CS3-EO-CFNB, Group 7: CS3-EX-Z250, Group 8: CS3-EX-CFNB. After bonding procedures, composite resins were built up on dentin surfaces. After 24-hour water storage, the teeth were sectioned to make 10 specimens for each group. The microtensile bond strength test was performed using a microtensile testing machine. The failure mode of the fractured specimens was examined by means of an optical microscope at ${\times}20$ magnification. The data was analyzed using a one-way ANOVA and Scheffe's post-hoc test (${\alpha}$=.05). RESULTS. Additional etching groups showed significantly higher values than the no additional etching group when using All-Bond Universal. The light-cured composite resin groups showed significantly higher values than the self-cured composite resin groups in the Clearfil S3 Bond. CONCLUSION. The additional acid etching is beneficial for the dentin bond strength when using low acidic one-step self-etch adhesives, and low acidic one-step self-etch adhesives are compatible with self-cured composite resin. The acidity of the one-step self-etch adhesives is an influencing factor in terms of the dentin bonding strength and incompatibility with a self-cured composite resin.

피션트랙 검출기법에 의한 고체 및 액체상태 지질물질의 우라늄 정량과 그 적용성 (Determination of Uranium Concentration in Solid- and Liquid-state Geological Materials by Fission Track Registration Technique and its Applicability)

  • 신성천
    • 암석학회지
    • /
    • 제24권2호
    • /
    • pp.77-90
    • /
    • 2015
  • 피션트랙 검출에 의해 고체 및 액체상태 지질물질 내 우라늄을 정밀정량하는 최적기법을 제안하고 그 적용성을 검증하였다. 우라늄 정량은 중성자 조사에 의해 유도시킨 $^{235}U$의 핵분열 흔적을 트랙 디텍터에 기록하여 고배율 현미경 하에서 계수함으로써 이루어진다. 우라늄-친화력이 좋은 암석(예: 화강암, 석탄)을 분말 펠릿시료로 만들어 건식 검출하면, 그다지 높지 않은 우라늄함량(<5 ppm, 즉 ${\mu}g\;g^{-1}$)에서도 빈번하게 함유된 함-우라늄광물에 기인한 트랙 군집현상으로 인해 시료의 전체평균 함량 결정이 쉽지 않았으며, 트랙 균질부와 군집부를 별도로 검토해야 한다. 시료의 균질성이 유지된다면 백운모-Lexan 디텍터에 의한 중복 측정과 여러 차례 중성자 조사에 의한 반복 측정에서 높은 재현성이 확인되었다. 건고 액체시료 경우에 $10^1ppm$ 수준 및 그 이상의 우라늄함량에서 흔히 나타나는 불균질 현상을 극복하기 위해, 진공 석영튜브를 이용한 습식 검출법을 제안한다. 습식 검출에서 우라늄 균질성은 $10^0ppm$ 수준 이하에서 회복되며, 측정하한은 $10^2ppb$ (i.e. $ng\;g^{-1}$) 수준까지 무난한 것으로 입증되었다.

KrF 엑시머 레이저를 이용한 웨이퍼 스텝퍼의 제작 및 성능분석

  • 이종현;최부연;김도훈;장원익;이용일;이진효
    • 한국광학회지
    • /
    • 제4권1호
    • /
    • pp.15-21
    • /
    • 1993
  • 본 연구에서는 설계제작된 KrF 엑시머 레이저 스텝퍼는 광원인 KrF엑시머 레이저, 조명광학계, 축소트영광학계, 정밀구동 웨이퍼 스테이지, 정렬시스템 및 이들을 제어하기 위한 제어계로 구성되어 있다. 본 실험에서 사용한 KrFdprtlaj 레이저는 밴드폭 3pm, 반복주파수 200Hz, 평균축력 3W이고, 5:1 투영렌즈는 N.A. 0.42, 전체 필드영역 $\varphi$21.2mm, 왜곡수차 최대 60nm 이하이다. 또한 정밀구동 웨이퍼 스테이지의 재현성과 해상도는 각각 $\pm$0.08$\mu\textrm{m}$/200mm(3 sigma), 100mm 반경에서 0.05 $\mu\textrm{m}$이다. 자동 초점 시스템은 $\pm$50$\mu\textrm{m}$범위에서 0.1$\mu\textrm{m}$의 해상도를 나타냈으며, 자동수평시스템은 120 arcsec 범위에서 larcsec의 해상도를 나타냈다. OFF-AXIS 정렬방식에서는 0.2$\mu\textrm{m}$의 해상도를 가지며, 두빔의 간섭을 이용한 새로운 TTL 정렬은 0.1$\mu\textrm{m}$의 해상도를 나타냈다. 스텝퍼 패턴 실험결과 SAL603레지스트를 사용하였을 때 웨이퍼의 노광후 열처리 $105^{\circ}C$, 60초에서 0.3$\mu\textrm{m}$ Lines and Spaces(L/S)까지 해상되었으며, 0.34$\mu\textrm{m}$ L/S에서 1$\mu\textrm{m}$의 초점심도를 얻을 수 있었다. 마스크 패턴과 레지스트 패턴의 선형성은 0.4$\mu\textrm{m}$ L/S가지 유지 되었다. 또한 XP-89131레지스트의 경우 노광후 열처리 $110^{\circ}C$, 60초에서 0.34$\mu\textrm{m}$ L/S까지 해상됨을 알수 있었다.

  • PDF

위상형 직선격자의 자체결상과 가시도 분석 (Self-imaging of a phase line grating and analysis of its visibility)

  • 백승선;이상일;조재흥;김영란
    • 한국광학회지
    • /
    • 제14권6호
    • /
    • pp.606-612
    • /
    • 2003
  • 위상형 직선격자에 가간섭 광원인 레이저 광을 조명하였을 때 이 격자가 렌즈없이 회절에 의하여 결상되는 자체결상 현상(또는 렌즈없는 결상)을 회절이론으로 해석하고 실험적으로 조사하였다. 위상형 격자의 위상분포가 강도분포로 바뀌면서 1:1 로 결상하는 자체결상거리( $Z_{T,a}$)를 진폭형 직선격자의 자체결상시 정의되는 자체결상거리 $z_{T,a}$를 이용하여(4n-3) $z_{T,a}$/4(n=양의 정수)와 같이 새로이 정의하였다. 실험적으로 $z_{T,p}$= $z_{T,a}$/4와 $z_{T,p}$=5 $z_{T,a}$/4에서 위상형 직선격자를 이용하여 자체결상거리에서 자체결상이 되는 것을 확인하였으며, $z_{T,p}$=3 $z_{T,a}$/4위치에서는 이 자체결상된 상의 위상이 반전되는 현상도 동시에 관찰하였다. 이러한 자체결상시 격자의 수에 따라 자체결상된 상의 가시도를 FFT(fast Fourier transform)로 처리하여 측정한 결과, 위상형 직선격자는 15 개 이상의 직선격자들로 구성되어야만 자체결상된 상의 가시도가 최대값 0.10 근처에서 일정하게 유지됨을 알 수 있었다.일정하게 유지됨을 알 수 있었다.

Development of a dual-mode energy-resolved neutron imaging detector: High spatial resolution and large field of view

  • Wenqin Yang;Jianrong Zhou;Jianqing Yang;Xingfen Jiang;Jinhao Tan;Lin Zhu;Xiaojuan Zhou;Yuanguang Xia;Li Yu;Xiuku Wang;Haiyun Teng;Jiajie Li;Yongxiang Qiu;Peixun Shen;Songlin Wang;Yadong Wei;Yushou Song;Jian Zhuang;Yubin Zhao;Junrong Zhang;Zhijia Sun;Yuanbo Chen
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2799-2805
    • /
    • 2024
  • Energy-resolved neutron imaging is an effective way to investigate the internal structure and residual stress of materials. Different sample sizes have varying requirements for the detector's imaging field of view (FOV) and spatial resolution. Therefore, a dual-mode energy-resolved neutron imaging detector was developed, which mainly consisted of a neutron scintillator screen, a mirror, imaging lenses, and a time-stamping optical fast camera. This detector could operate in a large FOV mode or a high spatial resolution mode. To evaluate the performance of the detector, the neutron wavelength spectra and the multiple spatial resolution tests were conducted at CSNS. The results demonstrated that the detector accurately measured the neutron wavelength spectra selected by a bandwidth chopper. The best spatial resolution was about 20 ㎛ in high spatial resolution mode after event reconstruction, and a FOV of 45.0 mm × 45.0 mm was obtained in large FOV mode. The feasibility was validated to change the spatial resolution and FOV by replacing the scintillator screen and adjusting the lens magnification.