• Title/Summary/Keyword: Optical fiber measurement

Search Result 465, Processing Time 0.022 seconds

Measurement Method and System of Optical Fiber-Based Beam Width Using a Reflective Grating Panel

  • Lee, Yeon-Gwan;Jang, Byeong-Wook;Kim, Yoon-Young;Kim, Jin-Hyuk;Kim, Chun-Gon
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.12 no.2
    • /
    • pp.175-178
    • /
    • 2011
  • An optical fiber-based beam width measurement technique is presented. The proposed system can be applied to the optical fiber industry in applications such as lensed fiber, optical fiber based laser beam source, and fiber optic sensor. The measurement system is composed of optical fiber, which is used as a transceiver, and a single grating panel which consists of a multi-reflection area with an even non-reflection area. The grating panel is used to vary the reflected light. When the widths of the reflection area and non-reflection area are larger than the optical beam width, the reflected light is varied at the interface between the reflection area and the non-reflection area by the movement of the grating panel. Experiments were conducted in order to verify the feasibility of the proposed technique. Multi-mode fiber combined with a collimator was selected as an emitter and a receiver, and the beam width measurement system was contrived. Subsequently, the proposed method and the system were verified by comparing the experimental results with the results of the conventional charge-coupled device technique.

Optical frequency domain reflectometry based on Wavelength swept mode locked fiber laser (Wavelength Swept 모드 록킹된 광섬유 레이저를 이용한 광주파수 영역에서 반사계)

  • 오명숙;박희수;김병윤
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.204-205
    • /
    • 2003
  • We demonstrate a novel OFDR system with compactness and short measurement time based on the use of a wavelength-swept mode-locked fiber laser. The optical source uses an intra-cavity tunable Fabry-Perot filter as a tuning element. The fiber laser sweeps 20 nm in less than 10 ms. Spatial resolution of 100 fm and total measurement range of several centimeters are demonstrate

  • PDF

Measurement method for profiling residual stress of an optical fiber (광섬유의 잔류응력 측정 방법)

  • 박용우;백문철;진애경;백운출;김덕영
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.3
    • /
    • pp.219-223
    • /
    • 2003
  • A novel method was proposed for determining the residual stress profile of an optical fiber by using a modified polariscope. Measurement results of the axisymmetric residual stress for a conventional single-mode fiber were demonstrated by using this method. It was found that non-uniform stress is distributed in the cladding of the fiber. This means that large mechanical stress is induced as a function of temperature generated near the neck shape of the fiber preform.

Damage Detection of Fiber-Metal Laminates Using Optical Fiber Sensors (광섬유 센서를 이용한 섬유-금속 적층판의 손상 감지)

  • 양유창;한경섭
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.161-164
    • /
    • 2002
  • Optical fiber vibrations sensors (OFVSs) and extrinsic Fabry-Perot interferometer (EFPI) were used in damage monitoring of fiber-metal laminates(FML). The optical fiber vibration sensor and EFPI were applied in order to detect and evaluate the strain, damage and failure of FML. Damages in composites, such as matrix cracks, delamination and fiber breakage may occur as a result of excessive load, fatigue and low-velocity impacts. Tensile test was performed with the measurement of optical signal and acoustic emission (AE). The signals of the optical fiber vibration sensor due to damages were quantitatively evaluated by wavelet transform. EFPI was less sensible to the damage signals compared with the optical fiber vibration sensor. It was found that damage information of comparable in quality to acoustic emission data could be obtained from the optical fiber vibration sensor signals.

  • PDF

Optical-fiber Electronic Speckle Pattern Interferometry for Quantitative Measurement of Defects on Aluminum Liners in Composite Pressure Vessels

  • Kim, Seong Jong;Kang, Young June;Choi, Nak-Jung
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.50-56
    • /
    • 2013
  • Optical-fiber electronic speckle pattern interferometry (ESPI) is a non-contact, non-destructive examination technique with the advantages of rapid measurement, high accuracy, and full-field measurement. The optical-fiber ESPI system used in this study was compact and portable with the advantages of easy set-up and signal acquisition. By suitably configuring the optical-fiber ESPI system, producing an image signal in a charge-coupled device camera, and periodically modulating beam phases, we obtained phase information from the speckle pattern using a four-step phase shifting algorithm. Moreover, we compared the actual defect size with that of interference fringes which appeared on a screen after calculating the pixel value according to the distance between the object and the CCD camera. Conventional methods of measuring defects are time-consuming and resource-intensive because the estimated values are relative. However, our simple method could quantitatively estimate the defect length by carrying out numerical analysis for obtaining values on the X-axis in a line profile. The results showed reliable values for average error rates and a decrease in the error rate with increasing defect length or pressure.

Winding Temperature Measurement in a 154 kV Transformer Filled with Natural Ester Fluid

  • Kweon, Dongjin;Koo, Kyosun
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.156-162
    • /
    • 2013
  • This paper measures the hot spot temperatures in a single-phase, 154 kV, 15/20 MVA power transformer filled with natural ester fluid using optical fiber sensors and compares them with those calculated by conventional heat run tests. A total of 14 optical fiber sensors were installed on the high-voltage and low-voltage windings to measure the hot spot temperatures. In addition, three thermocouples were installed in the transformer to measure the temperature distribution during the heat run tests. In the low-voltage winding, the hot spot temperature was $108.4^{\circ}C$, calculated by the conventional heat run test. However, the hot spot temperature measured using the optical fiber sensor was $129.4^{\circ}C$ between turns 2 and 3 on the upper side of the low-voltage winding. Therefore, the hot spot temperature of the low-voltage winding measured using the optical fiber sensor was $21.0^{\circ}C$ higher than that calculated by the conventional heat run test.

Effect of spectral drift to coherent optical fiber sensor (가간섭성 광섬유 센서에 대한 주파수 천이도의 영향)

  • Choi, Kyoo-Nam
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.3
    • /
    • pp.277-282
    • /
    • 2016
  • Effect of spectral drift in coherent fiber laser was investigated by injecting optical feedback to Fabry-Perot resonance loop. Er+3 doped fiber laser having unilateral optical feedback loop in Fabry-Perot configuration using two FBGs was fabricated. The optical feedback was found to be effective in linewidth reduction of fiber laser compared to the case without any optical feedback. The linewidth of three fiber lasers using above configuration were measured to be within 3kHz which is resolution-limited performance of self-heterodyne linewidth measurement set-up. The frequency drift measurement using Mach-Zehnder measurement set-up having 200m optical delay-line in one arm showed that the frequency drift rate of optical feedback fiber laser was measured as 300kHz/sec which was better than the case without optical feedback.

Gradient of the Residual Stress distribution in the Mechanical Defect on the Optical Fiber Surface (광섬유 표면의 기계적 손상에 대한 잔류응력 분포의 변화)

  • Sin, In-Hui;Kim, Deok-Yeong
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2005.07a
    • /
    • pp.206-207
    • /
    • 2005
  • The gradient of the residual stress distribution in the mechanical defect on the optical fiber surface was investigated. This gradient of the residual stress distribution appeared in both of the core and the clad of the mechanical defect region on the optical fiber. The residual stress measurement was suggested as a investigation method of the mechanical defect on the optical fiber.

  • PDF

Measurement of Pile Load Transfer using Optical Fiber Sensors (광섬유 센서에 의한 말뚝 하중전이 측정)

  • 오정호;이원제;이우진
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.397-404
    • /
    • 1999
  • It is essential to measure load transfer mechanism of pile to check the appropriateness of assumptions made for design purpose and to continuously monitor the behavior of pile foundation. Through many attempts to monitor the behavior of super-structure in civil engineering area using several optical fiber sensors have been made, application of optical fiber sensor technology on pile foundation has not been tried up to now. Load transfer of model piles during compression loading was measured by optical fiber sensors and compared with the measurement by strain gauges. Fiber Bragg Grating(FBG) sensor system was used since it has many advantages, such as easy multiplexing, high sensitivity, and simple fabrication. Besides the model pile tests, uniaxial tension test of steel bar and compression tests of mortar specimen were carried out to evaluate the performance of FBG sensors in embedded environments. The shift of refilming wavelength due to the strain in FBG sensor is converted to the strain at sensor location and the dependence between them is 1.28 pm/${\mu}$ strain. FBG sensors embedded in model pile showed a better survivability than strain gauges. Measured results of load transfer by both FBG sensors and strain gauges were similar, but FBG sensors showed a smoother trend than those by strain gauge. Based on the results of model pile test, it was concluded that the use of FBG sensor for strain measurement in pile has a great potential for the analysis of pile load transfer.

  • PDF