• 제목/요약/키워드: Optical diagnosis

검색결과 222건 처리시간 0.016초

광 버스트 스위칭을 위한 광 교환기에서의 다중 누화고장 진단기법 (Diagnosis of Multiple Crosstalk-Faults in Optical Cross Connects for Optical Burst Switching)

  • 김영재;조광현
    • 제어로봇시스템학회논문지
    • /
    • 제9권3호
    • /
    • pp.251-258
    • /
    • 2003
  • Optical Switching Matrix (OSM) or Optical Multistage Interconnection Networks (OMINs) comprising photonic switches have been studied extensively as important interconnecting blocks for Optical Cross Connects (OXC) based on Optical Burst Switching (OBS). A basic element of photonic switching networks is a 2$\times$2 directional coupler with two inputs and two outputs. This paper is concerned with the diagnosis of multiple crosstalk-faults in OSM. As the network size becomes larger in these days, the conventional diagnosis methods based on tests and simulation become inefficient, or even more impractical. We propose a simple and easily implementable algorithm for detection and isolation of the multiple crosstalk-faults in OSM. Specifically. we develop an algorithm for isolation of the source fault in switching elements whenever the multiple crosstalk-faults arc detected in OSM. The proposed algorithm is illustrated by an example of 16$\times$16 OSM.

Phase Bias Independent Fade-free Optical Fiber Interferometric Vibration Sensor

  • Youngwoong Kim;Jongyeol Kim;Younggwan Hwang;Gukbeen Ryu;Young Ho Kim;Myoung Jin Kim
    • Current Optics and Photonics
    • /
    • 제8권5호
    • /
    • pp.456-462
    • /
    • 2024
  • We propose a novel fade-free optical fiber interferometric vibration sensor using a simple setup with a 90° optical hybrid. The interferometer consists of all-optical components without the phase modulators and complex demodulation processes that were previously used to compensate for signal fading induced by phase bias change. Fade-free output was successfully obtained by in-phase and quadrature detection with a π/2 phase shifting scheme. Theoretical analysis and measurement results showed that the proposed interferometric vibration sensor operates independently of the phase bias state of interfering waves.

Optical diagnosis by near-focus versus normal-focus narrow band imaging colonoscopy in colorectal polyps based on combined NICE and WASP classification: a randomized controlled trial

  • Nisa Netinatsunton;Natcha Cheewasereechon;Tanawat Pattarapuntakul;Jaksin Sottisuporn;Kanet Kanjanapradit;Bancha Ovartlarnporn
    • Clinical Endoscopy
    • /
    • 제55권5호
    • /
    • pp.645-654
    • /
    • 2022
  • Background/Aims: Narrow Band Imaging (NBI) International Colorectal Endoscopic (NICE) and Workgroup Serrated Polyps and Polyposis (WASP) classifications were developed for optical diagnosis of neoplastic and sessile serrated polyps, respectively. Near-focus NBI with NICE combined with WASP criteria for optical diagnosis of colonic polyps has not yet been evaluated. We aimed to compare the accuracy of near-focus NBI (group A) with normal-focus NBI (group B) in real-time optical diagnosis of colorectal polyps using combined NICE and WASP criteria. Methods: Among 362 patients, 118 with 227 polyps were recruited. Groups A and B included 62 patients with 130 polyps (three lost polyps) and 56 patients with 106 polyps (six lost polyps), respectively. Optical diagnoses were compared with pathological reports. Results: The accuracy of optical diagnosis of neoplastic polyps in groups A and B was not significantly different (76% vs. 71%, p=0.52). WASP criteria provided all false positive diagnoses of sessile polyps as serrated polyps in 31 (16.2%) patients. Conclusions: Near-focus NBI was not superior to normal-focus NBI in optical diagnostics of neoplastic polyps using NICE criteria. In our study, WASP classification yielded all false positives in the diagnosis of sessile serrated adenomas/polyps. Routine real-life optical diagnosis of polyps is still unadvisable.

10 GHz Multiuser Optical CDMA Based on Spectral Phase Coding of Short Pulses

  • Ruan, Wan-Yong;Won, In-Jae;Park, Jae-Hyun;Seo, Dong-Sun
    • 전기전자학회논문지
    • /
    • 제13권1호
    • /
    • pp.65-70
    • /
    • 2009
  • We propose an ultrashort pulse optical code-division multiple-access (O-CDMA) scheme based on a pseudorandom binary M-sequence spectral phase encoding and decoding of coherent mode-locked laser pulses and perform a numerical simulation to analyze its feasibility. We demonstrate the ability to properly decode any of the multiple (eight) 10 Gbit/s users by the matched code selection of the spectral phase decoder. The peak power signal to noise ratio of properly and improperly decoded $8{\times}10 Gb/s$ signals could be greater than 15 for 127 M-sequence coding.

  • PDF

Computer-aided polyp characterization in colonoscopy: sufficient performance or not?

  • Natalie Halvorsen;Yuichi Mori
    • Clinical Endoscopy
    • /
    • 제57권1호
    • /
    • pp.18-23
    • /
    • 2024
  • Computer-assisted polyp characterization (computer-aided diagnosis, CADx) facilitates optical diagnosis during colonoscopy. Several studies have demonstrated high sensitivity and specificity of CADx tools in identifying neoplastic changes in colorectal polyps. To implement CADx tools in colonoscopy, there is a need to confirm whether these tools satisfy the threshold levels that are required to introduce optical diagnosis strategies such as "diagnose-and-leave," "resect-and-discard" or "DISCARD-lite." In this article, we review the available data from prospective trials regarding the effect of multiple CADx tools and discuss whether they meet these thresholds.

The Application of Optical Coherence Tomography in the Diagnosis of Marssonina Blotch in Apple Leaves

  • Lee, Changho;Lee, Seung-Yeol;Jung, Hee-Young;Kim, Jeehyun
    • Journal of the Optical Society of Korea
    • /
    • 제16권2호
    • /
    • pp.133-140
    • /
    • 2012
  • In this study we investigate the use of 2D and 3D scanning optical coherence tomography (OCT) technology for use in apple blotch diagnosis. In order to test the possible application of OCT as a detection tool for apple trees affected by Marssonina coronaria, we conducted several experiments and compared the results from both healthy and infected leaves. Using OCT, we found several distinctive features in the subsurface boundary regions of both the diseased and healthy leaves. Our results indicate that leaves from diseased trees, while still appearing healthy, can be affected by M. coronaria. The A-scan analysis method confirmed that the boundaries found under the subsurface layers can be faint. This shows that M. coronaria can exert its influence on entire apple trees (as opposed to only on leaves with lesions) once it infects healthy trees. Our results indicate that OCT can be used as a noninvasive tool for the diagnosis of fungal disease in apple trees. Microscopic imaging results, performed as a histological study for comparison, correlated well with the OCT results.

광 다단계 상호연결망의 단일 누화고장에 대한 해석적 고장진단 기법 (Analytical Diagnosis of Single Crosstalk-Fault in Optical Multistage Interconnection Networks)

  • 김영재;조광현
    • 제어로봇시스템학회논문지
    • /
    • 제8권3호
    • /
    • pp.256-263
    • /
    • 2002
  • Optical Multistage Interconnection Networks(OMINs) comprising photonic switches have been studied extensively as important interconnecting building blocks for communication networks and parallel computing systems. A basic element of photonic switching networks is a 2$\times$2 directional coupler with two inputs and two outputs. This paper is concerned with the diagnosis of cross-talk-faults in OMINs. As the size of today's network becomes very large, the conventional diagnosis methods based on tests and simulation have become inefficient, or even more, impractical. In this paper, we propose a simple and easily implementable algorithm for detection and isolation of the single crosstalk-fault in OMINs. Specifically, we develope an algorithm fur the isolation of the source fault in switching elements whenever the single crosstalk-fault is detected in OMINS. The proposed algorithm is illustrated by an example of 16$\times$16 banyan network.

Optical Coherence Tomography Applications for Dental Diagnostic Imaging: Prototype System Performance and Preclinical Trial

  • Eun Seo Choi;Won-Jin Yi;Chang-Seok Kim;Woosub Song;Byeong-il Lee
    • Current Optics and Photonics
    • /
    • 제7권3호
    • /
    • pp.283-296
    • /
    • 2023
  • An intraoral spectral domain optical coherence tomography (SD-OCT) system has been developed, using a custom-built hand-held scanner and spectrometer. The hand-held OCT probe, based on a microelectromechanical systems scanner and a self-built miniaturized drive circuit, had a field of view sufficient for dental diagnosis. The spectrometer using a fabricated f-theta lens provided the image depth required for dental diagnosis. The axial and transverse resolutions of the OCT system in air were 7.5 ㎛ and 12 ㎛ respectively. The hand-held probe could scan an area of 10 × 10 mm2, and the spectrometer could image along a depth of 2.5 mm. To verify the utility of the developed OCT system, OCT images of tooth hard and soft tissues were acquired, and a user-interface program for diagnosis was developed. Early caries and microcracks that were difficult to diagnose with existing methods could be found, and the state of restoration could be observed. Measuring the depth of the gingival sulcus, distinguishing subgingival calculus, and detecting an implant under the gingiva suggested the possibility of the SD-OCT system as a diagnostic for dental soft tissues. Through the presented OCT images, the capability of the developed SD-OCT system for dental diagnosis was demonstrated.