• 제목/요약/키워드: Optical density values

검색결과 161건 처리시간 0.024초

가축분뇨수의 색소오염물질 분해과정 측정 영상처리 시스템 (Image Processing System for Measuring the Chromatophore Pollution Solution of and Animal Slurry Using Optical-Density)

  • 이대원;김현태;김용석;민병로;이강춘;박은석;한정환;이수희;김정동
    • 한국축산시설환경학회지
    • /
    • 제7권2호
    • /
    • pp.103-110
    • /
    • 2001
  • This study conducted to monitor decomposition process of the charomatophore pollution solution of an animal slurry by using a CCD camera. After the solution was put into test tube, the images(R, G, B, H, L, S) values of the solution were measured by the imgae processing system, and those of it\`s optical density were measured for three hours to be decomposed by microscopic organism. The values of measured for three hours to be decomposed by microscopic organism. The values of measured images(R, G, B, H, L, S) were analysed and compared with those of the optical density. Some of the results are as follows. 1. High correlation coefficients, which analyzed by using data on linear equations, were 0.9557 and 0.9672. They were decreased regularly in this R-value experiment of RGB level. The microscopic organism in this experiment was effective for decomposition of the red charomatophore pollution solution. 2. The values of all correlation coefficients from relationship between RGB-value and optical density were more than 0.95 except H-values. RGB-values, which were average values of summed R, G, B values, had correlation coefficients of 0.9863, 0.9937. These results showed so good relationship that decomposition process of charomatophore pollution solution could be monitored by a image processing system.

  • PDF

입자상물질의 광학밀도 및 농도측정에 적용된 저가형 광학 부품의 성능평가 (Performance Evaluation of Low-cost Optical Components used for Measuring the Optical Density and Concentration of Particulate Matter(PM))

  • 백영조;홍터기;황철홍;박설현
    • 한국안전학회지
    • /
    • 제31권5호
    • /
    • pp.1-6
    • /
    • 2016
  • The performance of a set of low-cost optical components used for measuring the optical density of PM particles was evaluated in the present study. To this end, the set of low-cost optical components was replaced with that of general optical components used to measure the PM optical density under identical experimental conditions. The optical densities measured from the set of general optical components were then compared to those obtained from the set of low-cost optical components. While the optical density is measured, another key parameter, the dimensionless extinction constant of PM particles (which is needed to optically measure the PM concentration) was also determined in the present study. The experimental results indicate that the optical density and PM concentration measurements performed by low-cost optical components are feasible, producing trackable variations in the OD and concentrations compared to values obtained from the set of general optical components.

Merging Features and Optical-NIR Color Gradient of Early-type Galaxies

  • 김두호;임명신
    • 천문학회보
    • /
    • 제35권2호
    • /
    • pp.41.1-41.1
    • /
    • 2010
  • It has been suggested that merging plays an important role in the formation and the evolution of early-type galaxies. Optical-NIR color gradients of early-type galaxies in high density environments are found to be less steep than those in low density environment, hinting frequent merger activities in early-type galaxies in high density environment. In order to confirm if the flat color gradient is the result of dry merger, we decided to look deeply to find merging features and get their relation with color gradient. We selected samples which show extreme values of optical-NIR color gradients based on the data of previous study, and observed them at Maidanak observatory 1.5m telescope with long exposure. After masking out overlaid sources, our analysis reveals that these galaxies do not have extreme color gradient values. High degree sky flat technique was used during observation to aid discovery of faint, extended features. However, flatness of detector (SNUCAM) was good enough, so we could not see any marked improvement in image quality compared to those using normal sky flats. Additionally we noticed a feature that looks like merging tidal tail in the CFHT archival image, but this does not show up on the image we obtained. This demonstrates that flatness and correct sky estimation is very important when we look for faint merging features. In future we plan to enlarge the number of the sample.

  • PDF

EFFECT OF TITANIUM SURFACE ROUGHNESS ON CELL ADHESION OF HUMAN OSTEOBLAST-LIKE CELLS (MG63)

  • Yim Soon-Ho
    • 대한치과보철학회지
    • /
    • 제42권3호
    • /
    • pp.261-266
    • /
    • 2004
  • Statement of problem. The effects of surface roughness have not or insufficiently been analyzed on earlier events such as cell adhesion though cell behavior most germane to implant performance is cell adhesion. Purpose. The purpose of this study was to evaluate cell adhesion of osteoblast-like cells (MG63) onto three types of titanium disks with varying roughness using the Elisa assay. Materials and methods. Representative disks from each group (SLA, HA, machined) were subjected to surface analysis and surface roughness was measured by the optical interferometer (Accura 2000, Intekplus Co., Seoul, Korea). Following this, MG63 cells were cultured on the titanium disks and released. Cell adhesion measurements using the Elisa assay were performed specifically at three points: after 24, 48, and 72 hours of culture. Results. Among the 3 types of surface analyzed, the SLA surface was the roughest with a Ra value of $1.114{\mu}m$ followed by HA coated surface and machined surface, consecutively. The optical density values for the SLA surface group was significantly higher than that of the machined and HA coated surface groups following 24 and 48 hours of culture. The cell culture on HA coated surface showed significantly higher values compared to the machined surface following 24, 48 and 72 hours of culture. Conclusion. The results suggest that surface treatment of titanium surfaces enhanced cell adhesion of human osteoblast-like cells (MG63).

Laser imager의 성능관리에 대한 연구

  • 이형진;인경환;이원홍;김건중
    • 대한디지털의료영상학회논문지
    • /
    • 제3권1호
    • /
    • pp.126-132
    • /
    • 1997
  • Purpose : To apply to Program of Auto processor quality control after comparison of Film density variations with amendments to Auto density by using Check density program and Adjust density program of calibration mode into the Laser imager. Methods : Observe Check and Adjust density variations on the Control chart with standard step and value during seven months from December, 1995 to June, 1956 extending twice a week. (1) Measure density value on the steps after printing out 17-step sensitometric pattern of the Check density program. (2) In the same way, measure density values after amending density by using Adjust density program If they are exceeding allowable error limit. Results : In case of Check density program, the exceeding limit rates of Density difference(DD) and Middle density(MD) are: FL-IM3543 DD=75%. MD=72.5%, FL-IMD DD=0%. MD=30.8%(14.5%) After amending density by using Adjust density program, the exceeding limit rates of all both Laser imager were zero percent. The standard deviations are show lower FL-IM D than FL-IM3543 on the Check density control chart, but higher on the Adjust density control chart. Conclusion : (1) Check density variations by printingout sensitometric pattern extending once a week at least for quality control of the Laser imager. (2) In case of a dusty place, check the Laser beam transmission after cleaning Laser optical unit extending once a month. (3) Be sure to measure and check density values by using adjust density program if they are exceeding allowable error limit. (4) Maintain much better film density by performing the adjust density program even if check density values are existed within normal limit.

  • PDF

효소면역법에 의한 닭 전염성 후두기관염 바이러스 항체 측정에 관한 연구 (Detection of Antibody to Infectious Laryngotracheitis Virus by Enzyme Linked Immunosorbent Assay)

  • 임숙경;위성하;최정옥;고홍남
    • 한국동물위생학회지
    • /
    • 제15권1호
    • /
    • pp.32-45
    • /
    • 1992
  • In order to establish and enzyme-linked immunosorbent assay to ILTV, field virus strain of ILTV was propagated in chorioallantoic membrane of the embryonated eggs. purified and used as antigen. The antisera selected from the field samples and immunized chickens based on serum neutralization test were used as the standard positive and negative sera in all tests. It was found that optimal antigen concentration was $2{\mu}g$ of protein per well and a 1 : 100 dilution of standard serum showed low background optical density with negative serum and high P/N values of positive sera. A 1 : 500 dilution of the rabbit anti-chicken IgG peroxidase conjugate produced a high P/N values and thirty minutes was chosen as suitable time to read the optical density of the enzyme substrate reaction and optical density was consistent during the 16 hours after stopper was treated. When coated antigen was kept on microplate for varying time up to 16 hours at $4^{\circ}C$ or $37^{\circ}C,$ no significant difference was observed between the treatment. The coated antigen could be kept without change of antigenicity for at least one month at $-70^{\circ}C,\; -20^{\circ}C,\; 4^{\circ}C$ and room temperature. When blocking buffer contanining bovine serum albumin was mixed directly with conjugate and serum at 10% level induced higher P/N values compared to blocking antigen coated microplate with the same blocking buffer. The coefficience of correlation between ELISA and SN test was 0.577. When antibody response of chickens, vaccinated with ILTV, was examined by ELISA and SN test, antibody rising and decay pattern between the two test was similar until 11 weeks of age. However 12 weeks onward antibody titer checked on by SN test was slightly lower than that tested by ELISA.

  • PDF

금속가공유 시료에서 일부 Optical Density 설정값에 따른 엔도톡신의 정량 (Analysis of Endotoxin Using Analytical Conditions of Optical Density in Metalworking Fluid Sample)

  • 박동욱;한인영;윤충식;박두용
    • 분석과학
    • /
    • 제15권5호
    • /
    • pp.459-465
    • /
    • 2002
  • 본 연구에서는 금속가공유 (metalworking fluids, MWF)를 취급하는 사업장에서 채취한 벌크시료와 공기중 시료를 대상으로 엔도톡신 (endotoxin)의 정확한 분석을 위한 Optical Density (OD)의 설정조건을 검토하였다. OD값을 설정하는 Onset time방법이 "time to $V_{max}$"방법보다 재현성, 정확성이 높았다. 구체적인 OD설정값은 "0.03"이 가장 적정한 것으로 나타났다. 검량선의 상관계수 (직선성)가 0.998로서 가장 높았고 회수율도 88% - 105% (0.05 EU/mL과 5 EU/mL 범위)로서 다른 OD값 (OD "0.05", OD "0.1", "time to $V_{max}$")보다도 적정하였다. Onset time방법에서 설정해야 할 OD값은 "0.03"과 "0.05"이 적정한 것으로 나타났다. OD "0.03"과 "0.05"에 의한 엔도톡신 분석결과간의 상관계수 ($\gamma$)는 MWF시료에서는 0.97 그리고 공기 중 시료에서는 0.99로 유의하게 나타났다. 따라서 금속가공유를 대상으로 엔도톡신을 분석할 때는 Onset time 방법을 선택하고 구체적인 OD설정 값은 "0.03"과 "0.05"중에서 검량선의 상관성 (linearity)이 0.98 이상을 나타내는 OD값으로 분석하는 것이 적정한 것으로 판단된다.

An in Depth Study of Crystallinity, Crystallite Size and Orientation Measurements of a Selection of Poly(Ethylene Terephthalate) Fibers

  • Karacan Ismail
    • Fibers and Polymers
    • /
    • 제6권3호
    • /
    • pp.186-199
    • /
    • 2005
  • A selection of commercially available poly(ethy1ene terephtha1ate) fibers with different degrees of molecular alignment and crystallinity have been investigated utilizing a wide range of techniques including optical microscopy, infrared spectroscopy together with thermal and wide-angle X-ray diffraction techniques. Annealing experiments showed increased molecular alignment and crystallinity as shown by the increased values of birefringence and melting enthalpies. Crystallinity values determined from thermal analysis, density, unpolarized infrared spectroscopy and X-ray diffraction are compared and discussed in terms of the inherent capabilities and limitations of each measurement technique. The birefringence and refractive index values obtained from optical microscopy are found to decrease with increasing wavelength of light used in the experiments. The wide-angle X-ray diffraction analysis shows that the samples with relatively low orientation possess oriented non-crystalline array of chains whereas those with high molecular orientation possess well defined and oriented crystalline array of chains along the fiber axis direction. X-ray analysis showed increasing crystallite size trend with increasing molecular orientation. SEM images showed micro-cracks on low oriented fiber surfaces becoming smooth on highly oriented fiber surfaces. Excellent bending characteristics were observed with knotted fibers implying relatively easy fabric formation.

광디스크 기판 성형시 발생하는 복굴절의 최소화를 위한 이론적 연구 (An Theoretical Investigation on the Minimization of Birefringence Distribution in Optical Disk Substrate)

  • 김종성;강신일
    • 소성∙가공
    • /
    • 제9권2호
    • /
    • pp.103-111
    • /
    • 2000
  • It is necessary to improve mechanical and optical properties in the optical disk substrates as the information storage density using short wavelength laser are being developed. The birefringence distribution is regarded as one of the most important optical properties for optical disk. In the present study, the birefringence distrubution is calculated using the Leonov model for viscoelastic constitutive equations and Cross/WLF model for viscosity approximation. The effects of processing conditions upon the development of birefringence discosity approximation. The effects of processing conditions upon the development of birefringence distribution in the optical disk were examined theoretically. It was found that the values of the birefringence distributions were very sensitive to the mold wall temperature history which minimizes the birefringence distribution. The analytical results showed the possibility of improving mechanical and optical properties in the optical disk substrates by active control of the mold wall temperature history.

  • PDF

근접장 광기록 시스템용 전자기구동 액추에이터의 설계 및 평가 (Design and Evaluation of An Electromagnetic Driven Actuator for Near-field Optical Recording System)

  • 김석중;이용훈;이철우;서중언
    • 대한기계학회논문집A
    • /
    • 제24권11호
    • /
    • pp.2732-2741
    • /
    • 2000
  • Combination of magnetic recording technology and optical recording technology such as Near Field Optical Recording is watched recently. In order to accomplish this technology, the development of an electromagnetic driven mm-sized mirror shifting laser beam in track direction have to needed. In Near Field Optical Recording System, shifting laser beam in track direction mean as fine tracking and means as coarse tracking. Therefore in Near Field Optical Recording, 2-stage actuator is composed of servo controller in reading or recording information on disc layer. In our research, through design and simulation process of driven mm-sized mirror, we arrange systematically design process of driven mm-sized mirror having good frequency transfer characteristics. Design and simulation processes included modal analysis of spring, calculation of magnetic moment according to the number of turns and geometric configuration of coil and magnetic circuit analysis meaning that calculation of magnetic flux density in air gap of magnetic circuit. After that we design and make parts of driven mm-sized mirror, assemble and evaluate our electriomagnetic driven mm-sized mirror. we compared design values with actual characteristic values and present solution scheme. Through these processes we performed manufacturing of an electromagnetic driven mm-sized mirror having good frequency-domain characteristics and high sensitivity characteristics.