• 제목/요약/키워드: Optical Voltage Sensor

검색결과 118건 처리시간 0.02초

Sensing properties of optical fiber sensor to ultrasonic guided waves

  • Zhou, Wensong;Li, Hui;Dong, Yongkang;Wang, Anbang
    • Smart Structures and Systems
    • /
    • 제18권3호
    • /
    • pp.471-484
    • /
    • 2016
  • Optical fiber sensors have been proven that they have the potential to detect high-frequency ultrasonic signals, in structural health monitoring field which generally refers to acoustic emission signals from active structural damages and guided waves excited by ultrasonic actuators and propagating in waveguide. In this work, the sensing properties of optical fiber sensors based on Mach-Zehnder interferometer were investigated in the metal plate. Analytical formulas were conducted first to explore the parameters affecting its sensing performances. Due to the simple and definable frequency component, the Lamb wave excited by the piezoelectric wafer was employed to study the sensitivity of the proposed optical fiber sensors with respect to the frequency, rather than the acoustic emission signals. In the experiments, according to above investigations, spiral shape optical fiber sensors with different size were selected to increase their sensitivity. Lamb waves were excited by a circular piezoelectric wafer, while another piezoelectric wafer was used to compare their voltage responses. Furthermore, by changing the excitation frequency, the tuning frequency characteristic of the proposed optical fiber sensor was also investigated experimentally.

적외선 투과 광섬유를 이용한 비접촉식 온도 센서 개발을 위한 기초 연구 (Feasibility study on the development of noncontact temperature sensor using infrared optical fiber)

  • 유욱재;조동현;정순철;탁계래;전재훈;이봉수;손상희;조승현
    • 센서학회지
    • /
    • 제15권3호
    • /
    • pp.179-185
    • /
    • 2006
  • We have developed a noncontact temperature sensor using a silver halides infrared optical fiber. An infrared radiation from a heat source is transferred by a silver halides infrared optical fiber and measured by infrared sensors such as a thermopile and a thermal optical power-meter. The relationships between the temperature of a heat source and the output voltage of the thermopile and the optical power of a thermal optical power-meter are determined. The measurable temperature range using a thermopile and a thermal optical power-meter are from 100 to $750^{\circ}C$ and from 30 to $750^{\circ}C$ respectively. It is expected that a noncontact temperature sensor using infrared optical fiber can be developed for medical and industrial usages based on the results of this study.

레이저 거리 측정기용 광 검출기 수신 감도 실시간 측정 시스템 구현 (Implementation of the Real-time Measurement System of Receiver Sensitivity for a Laser Range Finder)

  • 이영주
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.108-111
    • /
    • 2016
  • We propose the method for measuring sensitivity of optical receiver of a long-range laser range finder in real-time. The sensitivity of the detector can be calculated using the detected voltage of the reference sensor, the area of the reference sensor and the transmittance ratio of neutral density filters. To evaluate the performance of the proposed method, we implemented a system and performed experiments. As a result, this system can be measured from 2nW to $113{\mu}W$. With this system, we measured the sensitivity of 37nW and 7nW with PIN PD and APD sample, respectively. This system has the advantage for the performance test of an optical sensor module in the long-range laser range finder.

Electro-optic Electric Field Sensor Utilizing Ti:LiNbO3 Symmetric Mach-Zehnder Interferometers

  • Jung, Hong-Sik
    • Journal of the Optical Society of Korea
    • /
    • 제16권1호
    • /
    • pp.47-52
    • /
    • 2012
  • The use of a $Ti:LiNbO_3$ symmetric Mach-Zehnder interferometric intensity modulator with a push-pull lumped electrode and a plate-type probe antenna to measure an electric field strength is described. The modulator has a small device size of $46{\times}7{\times}1mm$ and operates at a wavelength of $1.3{\mu}m$. The output characteristic of the interferometer shows the modulation depth of 100% and 75%, and $V_{\pi}$ voltage of 6.6 V, and 6.6 V at the 200 Hz and 1 KHz, respectively. The minimum detectable electric field is ~1.84 V/m, ~3.28 V/m, and ~11.6 V/m, corresponding to a dynamic range of about ~22 dB, ~17 dB, and ~6 dB at frequencies of 500 KHz, 1 MHz and 5 MHz, respectively.

간섭무늬의 변화갯수 측정을 이용한 광섬유 교류전압센서 (Fiber Optic AC Voltage Sensor Using Fringe Counting)

  • 김봉규;김병윤;김만식
    • 한국광학회지
    • /
    • 제5권1호
    • /
    • pp.158-165
    • /
    • 1994
  • 감지부의 PZT tube를 이용한 위상변조기를 연결한 광섬유 Mach-Zehnder 간섭계를 구성하고, 새로운 신호처리 장치를 도입하여 인가교류전압의 주파수에 상관없이 전압의 크기 및 인가전압의 파형을 측정할 수 있는 광섬유 전압센서를 구성하였다. 이 센서에서 전압변화에 따른 간섭무늬 변화갯수의 관계는 선형적 비례관계를 가짐을 관측하였으며, 온도변화에 따른 간섭무늬의 변화갯수를 측정했다. 또한, 간섭계 출력에서 편광변조에 의해 생길 수 있는 간섭무늬의 visibility의 변화를 없애기 위해 편광유지 광섬유를 이용한 간섭계 또는 광섬유 반파장판을 이용할 수 있음을 보였다.

  • PDF

압전전압 궤환에 의한 미세구동 연삭테이블의 개발 (A Development of Micro-Positioning Grinding Table using Piezoelectric Voltage Feedback)

  • 남수룡;김정두
    • 한국정밀공학회지
    • /
    • 제12권2호
    • /
    • pp.48-58
    • /
    • 1995
  • A micro positioning system using piezoelectric actuators have very wide application region such as ultra-precision machine tool, optical device, measurement systen. In order ro keep a high precision displacement resolution, they use a position sensor and feedback the error. From the practical point of view, a high-resolution displacement sensor system are very expensive and difficult to guarantee such sensitive sensors work properly in the hard opera- tion environment of industry. In this study, a micro-positioning grinding table which does not require position sensor but uses piezoelectric voltage feedback, has been developed. It is driven by hystersis-considering reference input voltage which calculated from computer and then uses actuator/sensor characteristics of piezoelectric materials. From the result of experiments we proved a fast and stable response of micro-positioning system and suggested efficient technique to control the piezoelectric actuator. And through grinding experiments, it is revealed that a characteristics of ground surfaces transient to plastic deformation as extremely small depth of grinding.

  • PDF

비분산 적외선 가스 센서 온도 보상법: 적외선 흡수도 (Temperature Compensation of Nondispersive Infrared Gas Senor: Infrared Light Absorbance)

  • 이승환
    • 센서학회지
    • /
    • 제30권1호
    • /
    • pp.36-41
    • /
    • 2021
  • The motivation of this paper is to easily analyze the properties of nondispersive infrared gas sensor that has more than two different optical path length and to suggest the criterion and definition of infrared light absorbance in order to minimize the measurement errors. With the output voltage ratios and the normalized derivatives of infrared ray (IR) absorbance, when the normalized derivatives of IR absorbance decreases from 0.28 to 0.10, the lower and higher limits of errors were decreased from -5.62% and 2.39% to -4.27% and 2.78%. When the normalized derivatives of IR absorbance were 0.10, the output voltage could be partitioned into two regions with one exponential equation and the temperature compensation error was less than 5%.

비분산 적외선 가스센서의 온도보상 알고리즘 (Temperature Compensation Algorithm of Nondispersive Infrared (NDIR) Gas Sensor)

  • 박종선;이승환
    • 한국가스학회지
    • /
    • 제15권4호
    • /
    • pp.51-55
    • /
    • 2011
  • 본 논문에서는 써모파일을 사용한 비분산 적외선 메탄가스센서의 온도보상 알고리즘을 제시하였다. 가스측정을 위해 적외선 감지부에 내장된 써미스터의 출력전압과 분위기 온도와의 상관성을 도출하고, 협 대역통과 필터 특성과 온도 변화에 따른 센서모듈(광 공동과 적외선램프)의 출력전압 특성 및 메탄가스의 흡수계수와 광 경로에 따른 출력특성 해석을 통하여 가스센서 모듈의 온도보상 알고리즘을 도출하였다.온도보상 전 약 $\pm$ 1,500 ppm 이상의 오차를 갖는 센서는 온도보상 알고리즘을 적용함으로써 $20^{\circ}C$온도변화 구간에서 최대 약 180 ppm 이하의 정밀한 센서모듈을 제작하였다.

냉각된 원전 2차계통수의 온도측정을 위한 비접촉식 광섬유 온도센서의 개발 (Development of a Fiber-optic Noncontact Temperature Sensor for Measuring the Temperature of Cooled Secondary Water in a Nuclear Power Plant)

  • 유욱재;이봉수;박병기;조영호
    • 한국산학기술학회논문지
    • /
    • 제11권5호
    • /
    • pp.1730-1734
    • /
    • 2010
  • 원전 2차계통수의 pH를 예측을 위해서는 샘플을 채취, 냉각시킨 후 pH를 측정하게 되는데 이 때 샘플의 온도는 pH를 변화시키는 중요한 요인이 된다. 본 연구에서는 할로겐화 은 광섬유를 이용하여 비접촉식 온도센서를 개발하였고, 열전쌍열을 이용하여 열원으로부터 방출되는 적외선을 측정하였다. 열원과 광섬유 끝단 사이의 거리 및 각도 변화에 따른 광섬유 온도센서의 출력신호를 분석하였으며, 광섬유 온도센서로 측정한 온도범위는 $25{\sim}60^{\circ}C$이다. 본 연구결과를 기초로 원전 2차계통수 pH 샘플의 온도를 측정하기 위해 할로겐화 은 광섬유를 이용한 비접촉식 온도센서의 개발이 가능할 것으로 기대된다.

절연진단용 광섬유 센서의 초음파 검출특성 (Ultrasonic-detection characteristics of optical-fiber sensor for insulation diagnosis)

  • 이상훈;심승환;이광식;김달우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.183-186
    • /
    • 2002
  • It is well known that a discharge in oil is the source of various physical and chemical phenomena. One of them is ultra-sonic wave, and its detection is a useful method to the diagnosis of the transformer insulation condition. Conventionally, ultra-sonic waves are detected by Piezo-electric trans-ducer(PZT), and we use optical method that has many advantages. In this paper, we constructed a Mach-Zehnder interferometer with optical fiber and investigated the principle of operation. Test of the ultrasonic-detecting ability was performed for both of PZT and fiber-optic sensor. Discharge test arrangement is based on the needle-plane electrode system in oil and applied AC high voltage. Ultrasonic waves were detected and showed time-delay characteristics. We analyzed the data with frequency domain and wavelet transform.

  • PDF