• Title/Summary/Keyword: Optical Property

Search Result 1,065, Processing Time 0.026 seconds

Three-Dimensional Analysis of the Collapse of a Fatty Acid at Various Compression Rates using In Situ Imaging Ellipsometry

  • Hwang, Soon Yong;Kim, Tae Jung;Byun, Jun Seok;Park, Han Gyeol;Choi, Junho;Kang, Yu Ri;Park, Jae Chan;Kim, Young Dong
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.350-358
    • /
    • 2014
  • The collapse of Langmuir monolayers of arachidic acid (AA) on water at various rates of molecular area compression has been investigated in situ by imaging ellipsometry (IE). The thickness of the collapsed AA molecules, which are inherently inhomogeneous, was determined by IE with a spatial resolution of a few microns. For the analysis, we determined the dielectric function of AA monolayers from 380 to 1690 nm by conventional spectroscopic ellipsometry. Compression rates ranged from 0.23 to $0.94{\AA}^2/min$. A change of multilayer domains was observed in the in situ IE images. Lower compression rates resulted in more uniform collapsed films. Our experimental results correspond with previous theoretical simulations.

Parametrization of the Optical Constants of AlAsxSb1-x Alloys in the Range 0.74-6.0 eV

  • Kim, Tae Jung;Byun, Jun Seok;Barange, Nilesh;Park, Han Gyeol;Kang, Yu Ri;Park, Jae Chan;Kim, Young Dong
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.359-364
    • /
    • 2014
  • We report parameters that allow the dielectric functions ${\varepsilon}={\varepsilon}_1+i{\varepsilon}_2$ of $AlAs_xSb_{1-x}$ alloys to be calculated analytically over the entire composition range $0{\leq}x{\leq}1$ in the spectral energy range from 0.74 to 6.0 eV by using the dielectric function parametric model (DFPM). The ${\varepsilon}$ spectra were obtained previously by spectroscopic ellipsometry for x = 0, 0.119, 0.288, 0.681, 0.829, and 1. The ${\varepsilon}$ data are successfully reconstructed and parameterized by six polynomials in excellent agreement with the data. We can determine ${\varepsilon}$ as a continuous function of As composition and energy over the ranges given above, and ${\varepsilon}$ can be converted to complex refractive indices using a simple relationship. We expect these results to be useful for the design of optoelectronic devices and also for in situ monitoring of AlAsSb film growth.

100W급 LED 보완가로등 직하조도 최적화를 위한 LightTools Simulation 분석

  • Sin, Ik-Tae;Jo, Ju-Ung;Yang, Jong-Gyeong;Park, Dae-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.164-164
    • /
    • 2009
  • This paper had analyzed property of LED chip which has appropriate distribution and had designed modeling in order to experiment optical property of LED module through simulation. also throughout error value between street light and simulation data, precisive simulation could be inferred. as a consequent, transformation of optical property had henceforth verified the first value of module array.

  • PDF

Development and Performance Property Investigation of Lighting System using Plastic Optical Fiber (플라스틱 광섬유를 이용한 조명시스템 개발과 특성 분석)

  • Shin, Sang-Uk;Yi, Chin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.25-32
    • /
    • 2010
  • Compared to general lighting method, the lighting system that uses optic fiber can provide only the visible light of good quality to subject by eliminating ultraviolet ray and infrared ray. Thanks to this merit, it is possible to prevent the hard phenomenon of subject caused by ultraviolet ray and infrared ray and to provide the agreeable light environment. This study developed indoors illumination system of high color rendering on the basis of plastic optic fiber with excellent optical property and processing to substitute halogen lamp which has been used for excellent color rendering in spite of low efficiency and short life. Producing pilot product of the designed illumination system and evaluating the property of electric and optical property, ultraviolet ray radiation quantity and temperature property, this study verified the excellence of suggested lighting system of plastic optic fiber.

Mechanical Properties and Sensibility Evaluation of Jacquard Fabric with Optical Fiber (광섬유 자카드 직물의 역학적 특성 및 감성평가)

  • Roh, Eui Kyung;Song, Byung Kab;Kim, Min Su
    • Fashion & Textile Research Journal
    • /
    • v.19 no.2
    • /
    • pp.240-248
    • /
    • 2017
  • This study compares general jacquard fabrics and jacquard fabrics with optical fiber on mechanical properties, sensibility and preference evaluation of fabric for the blind. The analysis also assesses the effect of optical fiber in the evaluation and identifies those best suited for consumers. The mechanical properties of jacquard fabrics were measured by the KES-FB system. Sensibility and the preference of the jacquard fabric for the blind were rated on tactile sensation by women experts in their 20's and 30's. It was found that the optical fiber in jacquard fabric affected the change of mechanical properties as well as sensibility and preference. Jacquard fabric with optical fiber were softer and more transformable, while the fabrics had lower recover property by shear force and compression as well as more violent unevenness. Jacquard fabrics were also classified into three hand factors of surface property, resilience and weightiness. There were significant differences on surface property perceptions and weightiness, hand and blind preferences by optical fiber. Jacquard fabrics that contained optical fiber were not preferred by the blind because they were perceived to be uneven and heavy. Those, that were smooth and light, were preferred for jacquard fabric; in addition, fabrics preferred by the blind had good compression.

Dielectric Function Analysis of Cubic CdSe Using Parametric Semiconductor Model (변수화 반도체 모델을 이용한 Cubic Zinc-blonde CdSe의 유전함수 분석)

  • Jung, Y.W.;Ghong, T.H.;Lee, S.Y.;Kim, Y.D.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.1
    • /
    • pp.40-45
    • /
    • 2007
  • ZnCdSe alloy semiconductor was widely used for the optoelectronic device. And CdSe is the end-point in this material. In this work, we measured the dielectric function spectrum of cubic CdSe with Vacuum Ultra Violet spectroscopic ellipsometry and analysed this data with parametric model. As a result, we observed some of transition energy point over 6 eV and obtained the database for dielectric function spectrum, which could be used for temperature or alloy composition dependence study on optical property of CdSe.

Reliability analysis test of high brightness micro optical component and module (고휘도 마이크로 광부품 / 모듈의 신뢰성 분석 시험)

  • Lee N.K.;Lee H.J.;Choi S.;Choi D.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.535-536
    • /
    • 2006
  • Researches about micro technology travel lively in these days. Such many researches are concentrated in the field of materials and a process field. But properties of micro materials should be known to give results of research developed into still more. In these various material properties, reliability data such as mechanical, optical, thermal property, etc is the basic property. In this paper, it is measured that is material properties of main BLU(Back Light Unit) components in LCD(Liquid Crystal Display). The pattern shape of prism sheet, diffuser film and reflective plate are measured by variable 3D scanning equipments. It is researched which is the method to measure an optimal 3D pattern shape in each components.

  • PDF

Study on Optical Properties of Lithium Niobate Using CMP (화학기계적 연마에 의한 리튬니오베이트의 광학 특성에 관한 연구)

  • Jeong, Suk-Hoon;Kim, Young-Jin;Lee, Hyun-Seop;Jeong, Hae-Do
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.3
    • /
    • pp.196-200
    • /
    • 2009
  • Lithium niobate ($LN:LiNbO_3$) is a compound of niobium, lithium and oxygen. The characteristics of LN are piezoelectricity, ferroelectricity and photoelectricity, and which is widely used in surface acoustic wave (SAW). To manufacture LN devices, the LN surface should be a smooth surface and defect-free because of optical property, but the LN material is processed difficult b traditional processes such as grinding and mechanical polishing (MP) because of its brittleness. To decrease defects, chemical mechanical polishing (CMP) was applied to the LN wafer. In this study, the suitable parameters such as down force and relative velocity, were investigated for the LN CMP process To improve roughness, the LN CMP was performed using the parameters that were the highest removal rate among process parameters. And, evaluation of optical property was performed by the optical reflectance.

Stiffness Comparison of Tissue Phantoms using Optical Coherence Elastography without a Load Cell

  • Chae, Yu-Gyeong;Park, Eun-Kee;Jeon, Min Yong;Jeon, Byeong-Hwan;Ahn, Yeh-Chan
    • Current Optics and Photonics
    • /
    • v.1 no.1
    • /
    • pp.17-22
    • /
    • 2017
  • Mechanical property of tissue is closely related to diseases such as breast cancer, prostate cancer, cirrhosis of the liver, and atherosclerosis. Therefore measurement of tissue mechanical property is important for a better diagnosis. Ultrasound elastography has been developed as a diagnostic modality for a number of diseases that maps mechanical property of tissue. Optical coherence elastography (OCE) has a higher spatial resolution than ultrasound elastography. OCE, therefore, could be a great help for early diagnosis. In this study, we made tissue phantoms and measured their compressive moduli with a rheometer measuring the response to applied force. Uniaxial strain of the tissue phantom was also measured with OCE by using cross-correlation of speckles and compared with the results from the rheometer. In order to compare stiffness of tissue phantoms by OCE, the applied force should be measured in addition to the strain. We, however, did not use a load cell that directly measures the applied force for each sample. Instead, we utilized one silicone film (called as reference phantom) for all OCE measurements that indirectly indicated the amount of the applied force by deformation. Therefore, all measurements were based on displacement, which was natural and effective for image-based elastography such as OCE.