• Title/Summary/Keyword: Optical Measurement

Search Result 3,146, Processing Time 0.031 seconds

A Study on the Relation Characteristics between Bubble Size Distribution and Floating Time (버블의 크기별 입도분포와 부상시간과의 상관특성에 관한 연구)

  • Jeon, Gun;Park, Chul-Hwi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.5
    • /
    • pp.277-281
    • /
    • 2017
  • Lately rainfall characteristics that it rains a lot in a short space of time often occurs. Because of this meteorological phenomena, the flow rate and concentration of initial rainfall for runoff and combined sewer overflows are changed. In the case of this inlet fluctuation, the flotation method at high surface loading rate is suitable for water quality management. the flotation method is able to meet the removal rate requirements of water public zone in 5 to 10 min which is irelatively short period. For assessment and diagonision of flotation method, A/S ratio is applied until now. But unfortunately, this has some limits for evaluation standard for certification and assessment of technical diagnosis and operation. This is why there is different efficiency in the bubble distribution at the same A/S ratio. The velocity and time of floating is changed by the different bubble distributions. The floating time affects the plant volume because the time factor make size dicision. Therefore the charateristics of bubble distribution and floating time at the same A/S ratio is necessary to apply to evaluation standard for certification and assessment of technical diagnosis and operation. For generalization of the method in certification and assessment, the characteristics of bubble distribution was studied. Until recently, using the optical device and shooting live video, there are some analysis technology of the floating factors. But this kind of technology is influenced by the equipment. with this level of confidence about the results, it is difficult to apply to generalize. According this reasons, this study should be applied on experiment generalization of method about measurement of relation between bubble distribution and floating time.

Transition Temperature of Mitochondrial Respiratory Activity as an Index for Chilling Susceptivity of Varieties of Rice Plant (미토콘드리아 호흡활성 전이온도의 측정에 의한 벼품종별 상대적 내냉성판정)

  • Jung, Jin;Kim, Hee-Jung
    • Applied Biological Chemistry
    • /
    • v.30 no.4
    • /
    • pp.357-363
    • /
    • 1987
  • The transition temperature of respiratory activity of mitochondria isolated from panicles of rice plant was measured with 41 varieties bred in Korea, which had been agronomically classified into five groups based on their relative cold-tolerance; S (strong cold-tolerance), S-M (moderate to strong cold-tolerance), M (moderate cold-tolerance), M-W (moderate to weak cold-tolerance) and W (weak cold-tolerance). The temperature was found to be $11.5{\sim}13.5^{\circ}C$ for group S, $13.5{\sim}16^{\circ}C$ for group S-M, $16{\sim}17^{\circ}C$ for group M, $17{\sim}18^{\circ}C$ for group M-W, and ${\geq}18^{\circ}C$ for group W respectively with a few exceptions of minor deviation, demonstrating a close correlation between the transition temperature and the chilling susceptivity of a variety. This observation supports the suggestion that the transition temperature of respiratory activity of panicles be adopted as a reliable index for grading a rice variety as to its overall cold tolerance. Also studied is on the methodology for measurement of the transition temperature in the aspect of analytical biochemistry. In addition to the usual polarographic method, a spectrophotometric method which is based on the enzymatic assay of membrane-bound cytochrome C oxidase was examined. This enzyme was found previousely and confirmed again in the present work to be a key factor governing the respiratory trantion at least in plant mitochondria. The optical method was turned out to be very successful, although it was a little more complicate and time-consuming than the electrochemical method.

  • PDF

A study on the sleeve-shaped platform of POF-based joint angle sensor for arm movement-monitoring clothing (인체동작 모니터링 위한 광섬유 기반 의류 소매형 동작센서 연구)

  • Kang, Da-Hye;Lee, Young-Jae;Lee, Jeong-Whan;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.14 no.2
    • /
    • pp.221-226
    • /
    • 2011
  • Although diverse researches on sensing method of human movement have been performed, there are still many limitations to the existing methods. As a part of supplementing the limitations to the existing motion sensing methods, this study aimed to execute an exploratory examination on a POF-based sleeve-shaped motion sensor for less restrictive sensing of human movement. In this study, a set of POF-based motion sensor, which was embedded in a sleeve-shaped platform was devised, and a set of exploratory experiments was performed on the possibility of sensing of human movement as diverse as in daily life, through this device. The scope of this research was limited to an exploration on the possibility and basic elements of POF-based sleeve-shaped motion sensor, while the influence of sleeve patterns, those of wearer's somatotype, those of sewing method were not studied in this study. When compared to the pre-existing methods, the POF-based motion sensor platformed on sleeve in this study, which was purposively devised to be applied to the motion sensing clothing shows some beneficial characteristics : more sensitive measurement on human motion, low cost, no timely restriction in sensing, no request for gigantic apparatus and space for sensing.

  • PDF

Compatibility of DOAS and Conventional Point Monitoring System Through an Evaluation of Bias Structures Using Long-term Measurement Data in Seoul (장기관측자료를 이용한 DOAS와 점측정 분석시스템의 바이어스 구조에 대한 평가)

  • 김기현;김민영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.5
    • /
    • pp.395-405
    • /
    • 2001
  • To make an assessment of the compatibility between DOAS and conventional point monitoring system (MCSAM-2: MS2), we investigated the concentrations of three criteria pollutants which include S $O_2$, N $O_2$, and $O_3$from a national monitoring station in Seoul during the periods of June 1999~August 2000. The average concentration values for the whole study period derived from hourly concentration data sets of those three species indicated that the mean differences between the two methods can be approximated as 18%. When the bias structure of two systems was evaluated through the computation of percent difference(PD) between the two such as ( $C_{DOAS}$- $C_{conventional}$ $C_{DOAS}$*100, differences between the two systems appeared to be quite systematic among different compounds. While the mode of bias peaked at 0~20% or 20~40% in terms of PD values, the cause of such positive bias mainly arised from generally enhanced concentration values of DOAS system. The structure of bias among different species was further assessed through linear regression analysis. Results of the analysis indicated that the dominant portions of differences observed from two monitoring systems can be accounted for by the systematic differences in their spanning and zeroing systems. S $O_2$(MS2)=0.6385 S $O_2$(DOAS)+2.0985($r^2$=0.7894) N $O_2$(MS2)=0.6548 N $O_2$(DOAS)+7.437($r^2$=0.7687) $O_3$(MS2)=1.0359 $O_3$(DOAS)-7.7885($r^2$=0.7944) The findings of slope values at around 0.64~0.65 from two species suggest that DOAS should respond more sensitively in upper bound concentration range. The offset values apart from zero indicate that more deliberate comparison needs to be made between these monitoring systems. However, based on the existence of strong correlations from at least 8,000 data points for each species of comparison, we were able to conclude that the compatibility of two monitoring systems is highly significant. With the improvement of calibration techniques for the DOAS system. its applicability for routine monitoring of airborne pollutant species is expected to be quite extendable.

  • PDF

A Study on Characteristics of Animal Glue depending on Pretreatment and Evaluation Condition (아교 전처리 및 평가 조건에 따른 특성연구)

  • Oh, Seong Min;Yu, Ji A;Lee, Na Ra;Kim, Tae Heon;Kim, Seong Eun;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • v.35 no.6
    • /
    • pp.701-708
    • /
    • 2019
  • Animal glue is a natural adhesive made from processed skins or bones of animals. It is widely used in wooden crafts, papercrafts, dancheong painting, and pictures. Accurate evaluation of the quality of animal glues during production and use is difficult because there is no formal method for testing the glue's properties during pretreatment and measurement conditions. Thus, in this study, a series of tests were carried out by changing the conditions of swelling, temperature, and concentration of animal glue and gelatin sold on the market. Twelve types of animal glues were evaluated, having a viscosity range of 12.67 cP to 29.43 cP. The results showed that the physical characteristics of the glues were stable when allowed to swell for six h in distilled water(23℃). When 10%(by weight in distilled water) of the animal glue was measured in the reflective mode of a spectrophotometer, the optical characteristics of the glues were stable. Powdered animal glues have a medium brightness and middle-high chroma. Relative to powdered glues, stick animal glues have a low brightness and a medium chroma. Based on the results of this study, it is expected that the data can be assembled into a form so that animal glue workers can use it as a reference for the preparation of evaluation standards for testing the characteristics of animal glues.

INTEGRATED RAY TRACING MODEL FOR END-TO-END PERFORMANCE VERIFICATION OF AMON-RA INSTRUMENT (AMON-RA 광학계를 활용한 통합적 광선 추적 기법의 지구 반사율 측정 성능 검증)

  • Lee, Jae-Min;Park, Won-Hyun;Ham, Sun-Jeong;Yi, Hyun-Su;Yoon, Jee-Yeon;Kim, Sug-Whan;Choi, Ki-Hyuk;Kim, Zeen-Chul;Lockwood, Mike
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.1
    • /
    • pp.69-78
    • /
    • 2007
  • The international EARTHSHINE mission is to measure 1% anomaly of the Earth global albedo and total solar irradiance using Amon-Ra instrument around Lagrange point 1. We developed a new ray truing based integrated end-to-end simulation tool that overcomes the shortcomings of the existing end-to-end performance simulation techniques. We then studied the in-orbit radiometric performance of the breadboard Anon-Ra visible channel optical system. The TSI variation and the Earth albedo anomaly, reported elsewhere, were used as the key input variables in the simulation. The output flux at the instrument focal plane confirms that the integrated ray tracing based end-to-end science simulation delivers the correct level of incident power to the Amon-Ra instrument well within the required measurement error budget of better than ${\pm}0.28%$. Using the global angular distribution model (ADM), the incident flux is then used to estimate the Earth global albedo and the TSI variation, confirming the validity of the primary science cases at the L1 halo orbit. These results imply that the integrated end-to-end ray tracing technique, reported here, can serve as an effective and powerful building block of the on-line science analysis tool in support of the international EARTHSHINE mission currently being developed.

A Study of Skin Reflectance Using Kubelka-Munk Model (Kubelka-Munk 모델을 이용한 피부 분광반사율 연구)

  • Cho, A Ra;Kim, Su Ji;Lee, Jun Bae;Sim, Geon Young;Back, Min;Cho, Eun Seul;Jang, Ji Hui;Jang, Eunseon;Kim, Youn Joon;Yoo, Kweon Jong;Han, Jeong Woo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.42 no.1
    • /
    • pp.45-55
    • /
    • 2016
  • Light shows various optical behaviors such as reflection, absorption, and scattering on skin for individuals. In particular, reflection of light from the skin has been widely used as the brightness index of the skin of individuals through the measurement of the physical quantity of spectral reflectance. Therefore, the study of light behavior on skin would be useful for the preparation of new evaluation method in the development stage of make-up products. In this study, multi-dimensional analysis for spectral reflectance behavior of light on individual skin was performed using Kubelka-Munk model. Also, we analyzed the contribution of skin parameters such as skin thickness and hemoglobin, which could affect the spectral reflectance, using above model and literature information. Base on this, we calculated the theoretical reflectance of normal women for visual light, which showed good agreement with the measured reflectance. Our study of light propagation in skin based on Kubelka-Munk model provides useful insight for the development of personalized cosmetic in the near future.

A Quantitative Method for Human Face Volume Using 3D Optical Measurement (3D 측정 기기를 이용한 얼굴의 부피 정량법 연구)

  • Park, Shin-Young;Nam,, Gae-Won;Kim, Seung-Hun;Lee, Hea-Kang;Ahn, Sung-Yeon;Moon, Seong-Joon;Kim, Han-Kon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.34 no.4
    • /
    • pp.333-338
    • /
    • 2008
  • The evaluation for the visage volume was performed with human and dummy face using PRIMOS $body^{(R)}$. Three researchers measured the dummy face attached different volume of clay (6.6 mL, 13.2 mL, and 19.8 mL). It is identified that the high correlation between measured values and real volume ($R^2=0.99$). The percent (%) of relative standard deviation (RSD) of the data was shown below 10%. In Gage R&R analysis, the percent of contribution, the percent of study variation and distinct categories values were 0.78%, 8.85%, and 15% respectively. Therefore this method was regarded as the good standard condition in aspect of reproducibility and repetitiveness of data. The face volume variation was measured by PRIMOS $body^{(R)}$ on the face in participated 10 healthy Korean women volunteers. Subjects used the product once a day for two weeks as night sleeping pack. After application of the test products, the 3D image data of face were taken 1 and 2 weeks later. We found the face volume was significantly decreased after using products. In conclusion, this novel non-invasive technique was useful in measuring and visualizing alterations in face volume as a consequence of certain treatments. This system will provide a rapid and precise analysis of 3D topographical information for face.

Electro-Optical Characteristics and Analysis of 1×1 mm2 Large-Area InGaN/GaN Green LED (1×1 mm2 대면적 녹색 LED의 전기 광학적 특성 분석)

  • Jang, L.W.;Jo, D.S.;Jeon, J.W.;Ahn, Tae-Young;Park, M.J.;Ahn, B.J.;Song, J.H.;Kwak, J.S.;Kim, Jin-Soo;Lee, I.H.;Ahn, H.K.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.4
    • /
    • pp.288-293
    • /
    • 2011
  • We investigated the effects of piezoelectric field on the electro-absorption characteristics in InGaN/GaN multiple-quantum well (MQW) green light emitting diodes (LED). Double crystal X-ray diffraction measurement was performed to study the crystalline property and indium (In) composition in the MQW active layer. To measure the electro-luminescence and electro-reflectance (ER) spectroscopy, we fabricated the $1{\times}1\;mm^2$ large-area green LED chip. The piezoelectric field inside the LED structure was evaluated from the Vcomp in active layer by the ER spectra. Finally, we analyzed the electro-absorption characteristics of the green LED by using the photo-current spectroscopy.

A Study on the Accuracy Analysis of Position Measurement Target for Underground Facilities by Retro-reflection (재귀반사체를 이용한 지하시설물 위치측정 타깃의 정확도 분석에 관한 연구)

  • Min, Kwan Sik;Kim, Jae Myeong;Choi, Yun Soo
    • Spatial Information Research
    • /
    • v.21 no.1
    • /
    • pp.45-52
    • /
    • 2013
  • Recently 3D surveying is recommended to manage underground facilities systematically before refilling of site operation. As the demand of realtime localization increases, cost reduction and consistent data construction which are realizable by using one man surveying method with unmanned target, are necessary for constructing DB of all sorts of the underground facilities with more speediness and correctness. This study sets a goal to develop a new type of surveying target which allows realtime localization to be performed by one man, through making an optimum reflector(triangle, quadrangle, and semispherical shape) by using the retro-reflection principle of optical prism which is being used for surveying currently. The new surveying target makes realtime surveying possible. To check reliability of its data, the accuracy is compared with surveying coordination of total station for each type in a quantitative method. In the result, the usefulness of the reflector for Underground Facilities localization is proved. Thus the foundation for underground DB construction conducted by one man is established for acquisition of 3D location information in more efficient way through using unmanned target.