• Title/Summary/Keyword: Optical Lens

Search Result 1,449, Processing Time 0.029 seconds

The comparison and the Analysis of the optical performances between the single and the symmetrical double DOE lenses (단매와 대칭 2매로 구성된 DOE 렌즈의 광학성능 비교 및 분석)

  • 이환선;임천석;조재홍
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.3
    • /
    • pp.258-265
    • /
    • 2002
  • In this paper, we design single and symmetrical double lenses with DOE. The specifications are the following : Image area is 4.8 mm $\times$ 3.6 mm, F/# is 2.8 and the overall length (from first lens surface to image plane) is 6.8mm. After comparing the optical performance and characteristic values, we determine that symmetrical double lenses are superior to single lenses. Symmetrical double lenses have the merits of fewer zones, weaker flare, and smaller distortion than single lenses.

The Analysis of position Sensitivity and Aberration characteristics of Liquid Crystal Elements (액정 소자의 위치 민감도 및 수차 특성에 대한 연구)

  • Heor Jae-Youn;Yoo Ho-Sik;Yoo Jang-Hoon;Park Soo Han;Jeong Soo-Jin
    • Transactions of the Society of Information Storage Systems
    • /
    • v.1 no.1
    • /
    • pp.78-83
    • /
    • 2005
  • The Blu-ray disc as a next generation high density optical medium uses an objective lens of high numerical aperture(NA 0.85) and blue laser in order to increase the recording density. The double layer is also useful for doubling the density. The spherical aberration of Blu-ray disc is very sensitive to the thickness of the disk because of high numerical aperture. This paper suggests a method to compensate the spherical aberration caused by the change of disk thickness, by using the Liquid Crystal lens instead of the Liquid Crystal panel. It was possible to develop both the LC panel generating the optical phase difference and LC lens changing the optical power. In this paper, we analyzed the aberration performance and a position sensitivity of the two type LC elements when the samples deviate from the optical axis of the objective lens. The results of applying this analysis show that the LC lenses rather than the LC panels have a significant assembling tolerance. The theoretical characteristics of the two elements are calculated and compared with the measurement data.

  • PDF

Unambiguous 3D Surface Measurement Method for a Micro-Fresnel Lens-Shaped Lenticular Lens Based on a Transmissive Interferometer

  • Yoon, Do-Young;Kim, Tai-Wook;Kim, Minsu;Pahk, Heui-Jae
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.37-44
    • /
    • 2014
  • The use of a laser interferometer as a metrological tool in micro-optics measurement is demonstrated. A transmissive interferometer is effective in measuring an optical specimen having a high angle slope. A configuration that consists of an optical resolution of 0.62 micron is adapted to measure a specimen, which is a micro-Fresnel lens-shaped lenticular lens. The measurement result shows a good repeatability at each fraction of facets, however, a reconstruction of the lens shape profile is disturbed by a known problem of $2{\pi}$-ambiguity. To solve this $2{\pi}$-ambiguity problem, we propose a two-step phase unwrapping method. In the first step, an unwrapped phase map is obtained by using a conventional unwrapping method. Then, a proposed unwrapping method based on the shape modeling is applied to correct the wrongly unwrapped phase. A measured height of each facet is compared with a profile result measured by AFM.

Fabrication of the focal length and distortion measurement system (초점길이 및 왜곡수차 측정장치 제작)

  • 조현모
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.82-86
    • /
    • 1990
  • A camera type optical bench system equipped with a lens collimator and an image analyzer is fabricated to measure the equivalent focal length and distortion of lenses. This system is automatized by the computer which controls stepping motors. A nodal slide optical bench system equipped with an off axis reflective collimator is fabricated and improved by using rotating arms and air bearing system. distortion measurement on a wide angle lens using the camera method and the nodal slide method is reported. Defocusing error in the distortion measurement with the nodal slide optical bench is analyzed and improved by iteration method to search the correct image point.

  • PDF

Optical Packaging and Interconnection Technology (광 패키징 및 인터커넥션 기술)

  • Kim, Dong Min;Ryu, Jin Hwa;Jeong, Myung Yung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.19 no.4
    • /
    • pp.13-18
    • /
    • 2012
  • By the need for high-speed data transmission in PCB, the studies on the optical PCB has been conducted with optical interconnection and its packaging technology. Particularly, the polymer-based optical interconnection has been extensively studied with the advantages such as cost-effective and ease of process. For high-efficiency and passive alignment, the studies were performed using the 45 degree mirrors, MT connector, and etc. In this work, integrated PLC device and fiber alignment array block was fabricated by using imprint technology to solve the alignment and array problem of optical device and the optical fiber. The fabricated integrated block for optical interconnection of PLC device has achieved higher precision of decreasing the dimensional error of the patterns by optimization of process and its insertion loss has an average value of 4.03dB, lower than criteria specified by international standard. In addition, a optical waveguide with built-in lens has been proposed for high-efficiency and passive alignment. By simulation, it was confirmed that the proposed structure has higher coupling efficiency than conventional no-lens structure and has the broad tolerance for the spatial offset of optical waveguide.

Thermo-optical Analysis and Correction Method for an Optical Window in Low Temperature and Vacuum

  • Ruoyan Wang;Ruihu Ni;Zhishan Gao;Lingjie Wang;Qun Yuan
    • Current Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.213-221
    • /
    • 2023
  • The optical window, as a part of the collimator system, is the connector between the outside light source and the optical system inside a vacuum tank. The temperature and pressure difference between the two sides of the optical window cause not only thermoelastic deformation, but also refractive-index irregularities. To suppress the influence of these two changes on the performance of the collimator system, thermo-optical analysis is employed. Coefficients that characterize the deformations and refractive-index distributions are derived through finite-element analysis, and then imported into the collimator system using a user-defined surface in ZEMAX. The temperature and pressure difference imposed on the window seriously degrade the system performance of the collimator. A decentered and tilted lens group is designed to correct both field aberrations and the thermal effects of the window. Through lens-interval adjustment of the lens group, the diffraction-limited performance of the collimator can be maintained with a vacuum level of 10-5 Pa and inside temperature ranging from -100 ℃ to 20 ℃.

Optics of the light-weight and foldable telescope based on the Fresnel lens

  • Yu, Hyungjoon;Park, Yong-Sun;Chung, Haeun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.57.3-58
    • /
    • 2016
  • We analyze an optical system of a telescope based on Fresnel type objective lens as suggested by Hyde (1999). The Fresnel objective lens can be thin, light-weight and foldable, and therefore it is possible to develop a space telescope with an aperture larger than that of traditional telescopes. Moreover a lens, whatever it is either Fresnel type or conventional, allows much larger fabrication tolerances. We design a medium-sized telescope adopting Fresnel lens as an objective lens for use in space and possibly on the ground. The well-known chromatic aberration of the Fresnel primary lens is corrected by a field lens and another Fresnel lens using Schupmann method. An additional lens is used for forming images. We analyze the chromatic and off-axis aberrations of the proposed system analytically and suggest methods for the minimization of off-axis aberrations and for the operation in wider spectral range. We also conduct ray tracing and optimize the whole optical system with commercial software. Finally we present the design parameters of a telescope with an aperture of 0.5 to 1 meters, enabling diffraction limited operation for a moderate field of view about 10 arc-minutes.

  • PDF

Design for High-Efficient Passive Optical PCB Interconnection by Using Built-in Lens Structure (렌즈 일체형 광도파로를 이용한 고효율 수동 광 PCB 접속 구조 설계)

  • Kim, Dong-Min;Lee, Tae-Kyoung;Lee, Tae-Ho;Jeong, Myung-Yung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.19 no.2
    • /
    • pp.47-53
    • /
    • 2012
  • Recently, by the increasing of data transmission rates, PCB is required high-speed data transmission rates and thin packaging. So optical PCB which is the combination of electrical layer and optical layer can be one of the solution to overcome the limitations of conventional electrical PCB. The most important factor in the implementation of optical PCB is optical interconnection. So the research on high-efficiency and passive alignment has been active. In this paper, we suggest built-in lens pluggable waveguide and we simulate its coupling efficiency and structural stability. Optical simulation results show that the proposed structure has higher efficiency than no lens structure about 1.86 times in transmitter and about 1.42 times in receiver. In structure simulation, inner lens has no damage in desorption process. Therefore, we shown that the proposed structure has a high coupling efficiency and structural stability.

Lens system design for head mounted display using schematic eyes (정밀모형안을 이용한 Head Mounted Display용 렌즈계 설계)

  • 박성찬;안현경
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.3
    • /
    • pp.236-243
    • /
    • 2003
  • We discussed the design of lens module schematic eyes equivalent to finite model eyes, which are used to model the human eye based on spherical aberration and Stiles-Crowford effect. The optical system for head mounted display (HMD) is designed and evaluated using lens module schematic eyes. In addition to a compact HMD system, an optical system with high Performance is required. To satisfy these requirements, we used diffractive optical elements and aspheric surfaces so that the color and mono-chromatic aberrations were corrected. The optical system for HMD is composed of 0.47 inch micro-display of SVGA grade with 480,000 pixels, a plastic hybrid lens for the virtual image, and the lens module schematic eyes. The designed optical system fulfills the current specifications of HMD: such as, EFL of 31.25 mm, FOV of 24H$\times$18V$\times$30D degrees, and overall length of 59.1 mm. As a result, we could design an optical system useful for HMD; the system is expected to be comfortable while the user wears it.