• Title/Summary/Keyword: Optical Correlation

Search Result 738, Processing Time 0.029 seconds

THE INFLUENCE OF PORCELAIN LAYER THICKNESS AND COLOR ON THE FINAL SHADE OF CERAMIC RESTORATIONS (도재층의 두께와 색이 도재수복물의 최종 색조에 미치는 영향)

  • Seong Dong-Hwan;Lee Im-Gi;Sohng Jin-Won;Bok Won-Mi;Ahn Seung-Geun;Park Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.5
    • /
    • pp.587-598
    • /
    • 2005
  • Statement of problem: Ceramic restorations should be made of porcelain layers of different opacity, shade, and thickness in order to provide a natural appearance. Lithium disilicate glass-ceramic system has superior color reproducibility, because it uses the ceramic ingot which is similar to teeth shade and uses the staining technique and layering technique. However, staining technique has a fault of discoloration. Also, porcelain is divided core and dentin layer, it is not enough to study about the influence of porcelain layer thickness and shade on the shade of ceramic restorations. Purpose: The purpose of this study was to evaluate the influence of porcelain layer thickness and color on the final shade of ceramic restorations. Materials and method: The CIE $L^*a^*b^*$(CIELAB) values of 72 assembled specimens, each consisting of 3 discs (enamel porcelain 0.2 mm/dentin porcelain -1.2, 0.9, 0.7, 0.5 or 0.3 mm/ceramic core -0.3, 0.5, 0.7, 0.9 or 1.2 mm, diameter is 1.0 mm) were evaluated with a spectrophotometer (Model Chromaview 300, Spectron Tech Co, Korea) for the shade A1, A2, A3 and A4. Distilled water (refractive index: 1.7) was used to attain optical contact between the layers. White, white gray, and white brown backgrounds were used to assess the influence of the background on the final shade. And the mean color difference value$({\Delta}E)$ was calculated. Results and conclusion: The results obtained from this study were as follows. 1. There was a significant correlation between the thickness ratio of the ceramic core/dentin porcelain system and $L^*,\;a^*\;and\;b^*$ values when the total thickness of specimen combination was smaller than 1.4 mm(P<0.05). 2. The specimen which the ceramic core thickness was more than 0.7 mm had the best masking effect against background colors. 3. The mean color difference value$({\Delta}E)$ is smaller than 2 $({\Delta}E<2)$ when the ceramic core thickness was larger than 0.7 mm and the total thickness of specimen was more than 1.4 mm.

a-Si:H/c-Si Heterojunction Solar Cell Performances Using 50 ㎛ Thin Wafer Substrate (50 ㎛ 기판을 이용한 a-Si:H/c-Si 이종접합 태양전지 제조 및 특성 분석)

  • Song, Jun Yong;Choi, Jang Hoon;Jeong, Dae Young;Song, Hee-Eun;Kim, Donghwan;Lee, Jeong Chul
    • Korean Journal of Materials Research
    • /
    • v.23 no.1
    • /
    • pp.35-40
    • /
    • 2013
  • In this study, the influence on the surface passivation properties of crystalline silicon according to silicon wafer thickness, and the correlation with a-Si:H/c-Si heterojunction solar cell performances were investigated. The wafers passivated by p(n)-doped a-Si:H layers show poor passivation properties because of the doping elements, such as boron(B) and phosphorous(P), which result in a low minority carrier lifetime (MCLT). A decrease in open circuit voltage ($V_{oc}$) was observed when the wafer thickness was thinned from $170{\mu}m$ to $50{\mu}m$. On the other hand, wafers incorporating intrinsic (i) a-Si:H as a passivation layer showed high quality passivation of a-Si:H/c-Si. The implied $V_{oc}$ of the ITO/p a-Si:H/i a-Si:H/n c-Si wafer/i a-Si:H/n a-Si:H/ITO stacked layers was 0.715 V for $50{\mu}m$ c-Si substrate, and 0.704 V for $170{\mu}m$ c-Si. The $V_{oc}$ in the heterojunction solar cells increased with decreases in the substrate thickness. The high quality passivation property on the c-Si led to an increasing of $V_{oc}$ in the thinner wafer. Short circuit current decreased as the substrate became thinner because of the low optical absorption for long wavelength light. In this paper, we show that high quality passivation of c-Si plays a role in heterojunction solar cells and is important in the development of thinner wafer technology.

Classification of Various Severe Hazes and Its Optical Properties in Korea for 2011~2013 (2011~2013년 한반도에서 관측된 다양한 연무의 분류 및 광학특성)

  • Lee, Kyu-Min;Eun, Seung-Hee;Kim, Byung-Gon;Zhang, Wenting;Park, Jin-Soo;Ahn, Jun-Young;Chung, Kyung-Won;Park, Il-Soo
    • Atmosphere
    • /
    • v.27 no.2
    • /
    • pp.225-233
    • /
    • 2017
  • Korea has recently suffered from severe hazes, largely being long-range transported from China but frequently mixed with domestic pollution. It is important to identify the origin of the frequently-occurring hazes, which is however hard to clearly determine in a quantitative term. In this regard, we suggest a possible classification procedure of various hazes into long-range transported haze (LH), Yellow Sand (YS), and urban haze (UH), based on mass loading of fine particles, time lag of PM mass concentrations between two sites aligned with dominant wind direction, backward trajectory of air mass, and the mass ratio of PM2.5 to PM10. The analysis sites are Seoul (SL) and Baengnyeongdo (BN), which are distant about 200 km from each other in the west to east direction. Aerosol concentrations at BN are overall lower than those of SL, indicative of BN being a background site for SL. We found distinct time lag of PM2.5 and PM10 concentrations between BN and SL in case of both LH and YS, but the intensity of YS being stronger than LH. Time scale (e-folding time scale) of LH appears to be longer and more variable than YS, which implies that LH covers much larger spatial scale. In addition, we found linear and significant correlations between ${\tau}_a$ obtained from sunphotometer and ${\tau}_{cal}$ calculated from surface aerosol scattering coefficient for LH episodes, relative to few correlation between those for YS, which might be associated with transported height of YS being much higher than LH. Therefore surface PM concentrations for the YS period are thought to be not representative for vertical integrated amount of aerosol loadings, probably by virtue of decoupled structure of aerosol vertical distribution. Improvement of various hazes classification based on the current result would provide the public as well as researchers with more accurate information of LH, UH, and YS, in terms of temporal scale, size, vertical distribution of aerosols, etc.

TRANSLUCENCY OF LIGHT CURED COMPOSITE RESINS DEPENDS ON THICKNESS & ITS INFLUENCE ON COLOR OF RESTORATIONS (광중합복합레진의 두께에 따른 투명도 차이가 수복물의 색상에 미치는 영향)

  • Hwang, In-Nam;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.585-603
    • /
    • 1999
  • Esthetic availabilities used as an esthetic restorative maternals can be determined by the optical coincidence among materials, enamel and dentin. Enamel is highly translucent. That's why esthetic materials need to correspond the close translucency of enamel. But the translucent materials are affected by the background color. So it should be predicted that the color of estorative materials depend on the any thickness and the spectral reflectance of the background on which they are placed. The object of this investigation, under above hypothesis, was to determine and analyze how they affect the final color according to the thickness, translucency and background color (white, black and dentin) fill three commercial light cured composite resins(Charisma, Spectrum TPH and Z100). And correlation was analyzed to find out the possibility of the prediction when using the certain background color and thickness of materials. Followings are the result 1. The I shade of CHA showed the lowest contrast ratio($Co_7$) while the B3 shade of Z100 showed the highest contrast ratio(p<0.05). 2. The value of $L^*$ and $b^*$ on the white and dentin background is increased with decreasing thickness. And there are significant relationships between increasing thickness and each value(R>0.085). But there is a little change of $L^*$ and $b^*$ value on the black background regardless of the thickness(p>0.05). 3. For the $a^*$ value, there was little difference in values as a function of thickness and changed irregularly regardless of thickness in all background. 4. The pattern of increasing value of $L^*$ and $b^*$ with decreasing thickness was similar to the group of white and dentin background. In both dentin one showed lesser change of value. 5. The values of $L^*a^*b^*$ measured on the different background with same thickness showed the recognizable color difference(${\Delta}E^*$>2) when the thickness was below 2.6mm. 6. Contrast ratio was increased with increasing thickness with significant relationship (R>0.9). 7. Spectral reflectance of composite resins that calculated from Kubelka-Munk equation was showed little difference compared with observed value w1th decreasing thickness.

  • PDF

DEVELOPMENT OF OPTICAL CARIES ACTIVITY TEST USING DENTAL CURING LIGHT (광중합기를 이용한 광학적 치아우식활성도 검사법)

  • Lee, Nan-Young;Kim, Mi-Ra;Oh, You-Hyang;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.671-679
    • /
    • 2004
  • The purpose of this study was to develop a practical caries activity test by fluorescence using laser, plasma light and halogen light. The subjects of study were 45 children of 7-8 years old Argon laser, plasma light and halogen light were irradiated to buccal or labial surface of all teeth. Fluorescence of initial carious lesion from teeth was observed through barrier filter and the number of teeth showing lesion was counted. Visual examination for the dDfFtT, mutans streptococci screening test and Lactobacilli colony counting were also done. Data analysis was accomplished by Axelsson's method. The result from the present study can be summarized as follows. 1. Laser, plasma light and halogen light could detect the initial carious lesions better than visual examination(p<0.05). 2. There was positive correlation between laser(r=0.42), plasma light(r=0.41), halogen light(r=0.39) and dBfFtT rate(p<0.01). 3. The specificity sensitivity and predictive value was showed highest value in laser, but was showed favorable value in plasma light and halogen light. In regard to above results, laser, plasma light and halogen light all considered to be reliable method for determining individual caries activity. And they were also considered to be practical method because it would be simple, inexpensive, and time saving method.

  • PDF

An Efficient Coding Technique of Holographic Video Signal using 3D Segment Scanning (분할영역의 3차원 스캐닝을 이용한 홀로그래픽 비디오 신호의 효율적인 부호화 기술)

  • Seo, Young-Ho;Choi, Hyun-Jun;Kim, Dong-Wook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.2C
    • /
    • pp.132-140
    • /
    • 2007
  • In this paper, we proposed a new technique to encode and decode the digital hologram. Since the digital hologram (or fringe pattern) is generated by interference of light, it has much different property from natural 2D (2 dimensional) images. First, we acquisite optical-sensed or computer-generated hologram by digital type, and then extract a chrominance component. The extracted digital hologram for coding is separated into segments to use multi-view properties. The segmented hologram shows the similar characteristics with picturing an object with 2D cameras in various point of view. Since fringe pattern is visually observed like as noise, we expect that the fringe pattern has poor coding efficiency. To obtain high efficiency, the segment is transformed with DCT (Discrete Cosine Transform) which resembles hologram generation process with high performance. Each transformed segment passes the 3D scanning process according to time and spatial correlation, and is organized into a video stream. Since the segment which correspond to frame of a video stream consists of the transformed coefficients with wide range of value, it is classified and re-normalized. Finally it is compressed with coding tools. The proposed algorithm illustrated that it has better properties for reconstruction of 16 times higher compression rate than the previous researches.

Dentin bond strength of bonding agents cured with Light Emitting Diode (LIGHT EMITTING DIODE로 광조사한 상아질 접착제의 상아질 전단접착강도와 중합률에 관한 연구)

  • Kim Sun-Young;Lee In-Bog;Cho Byeong-Hoon;Son Ho-Hyun;Kim Mi-Ja;Seok Chang-In;Um Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.6
    • /
    • pp.504-514
    • /
    • 2004
  • This study compared the dentin shear bond strengths of currently used dentin bonding agents that were irradiated with an LED (Elipar FreeLight, 3M-ESPE) and a halogen light (VIP, BISCO). The optical characteristics of two light curing units were evaluated. Extracted human third molars were prepared to expose the occlusal dentin and the bonding procedures were performed under the irradiation with each light curing unit. The dentin bonding agents used in this study were Scotchbond Multipurpose (3M ESPE), Single Bond (3M ESPE), One-Step (Bisco), Clearfil SE bond (Kuraray), and Adper Prompt (3M ESPE), The shear test was performed by employing the design of a chisel-on-iris supported with a Teflon wall. The fractured dentin surface was observed with SEM to determine the failure mode. The spectral appearance of the LED light curing unit was different from that of the halogen light curing unit in terms of maximum peak and distribution. The LED LCU (maximum peak in 465 nm) shows a narrower spectral distribution than the halogen LCU (maximum peak in 487 nm). With the exception of the Clearfil SE bond (P < 0.05), each 4 dentin bonding agents showed no significant difference between the halogen light-cured group and the LED light-cured group in the mean shear bond strength (P > 0.05). The results can be explained by the strong correlation between the absorption spectrum of camphoroquinone and the narrow emission spectrum of LED.

A Case of Unilateral Focal Pigmented Paravenous Retinochoroidal Atrophy (단안에 국소적으로 발현된 색소정맥옆망막맥락막 위축 1예)

  • Park, Hyo Song;Yang, Jong Yun;Park, Hyun Ju
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.12
    • /
    • pp.1190-1194
    • /
    • 2018
  • Purpose: We report a case of unilateral, focal, pigmented paravenous retinochoroidal atrophy (PPRCA). Case summary: A 46-year-old female visited our clinic in complaint of a vague problem with her right eye identified during a general medical examination. The visual acuity (without correction) of both eyes was 1.0. Slit-lamp examination of both eyes revealed no specific signs. Fundus examination of the right eye revealed focal, bony-spicule-shaped retinochoroidal atrophy with pigmentation along the course of the superior retinal vein. A fundus autofluorescence examination revealed principally hypofluorescence with some hyperfluorescence at the margin of the atrophic retinochoroidal lesion. Optical coherence tomography revealed mixed clumping and atrophy of the retinal pigment epithelium (RPE) layer and thinning of the choriocapillaris layer. Fluorescence angiography revealed a window defect and blockage at the site of the lesion (the fluorescent material did not enter the lesion). The site of the window defect was in correlation with the atrophic RPE region. The site of the blockage at lesion also matched with the site of the regional pigment clumping. No definite leakage was observed. Conclusions: To the best of our knowledge, this is the first case of unilateral focal PPRCA reported from Korea.

Difference between Collection 4 and 5 MODIS Aerosol Products and Comparison with Ground based Measurements (Collection 4 와 Collection 5 MODIS 에어러솔 분석 자료의 차이와 지상관측자료와의 비교)

  • Lee, Kwon-Ho;Kim, Young-Joon
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.4
    • /
    • pp.369-379
    • /
    • 2008
  • The aerosol retrieval algorithm for the Moderate Resolution Imaging Spectroradiometer (MODIS) measurements was updated recently. This paper reports on the comparison and validation of two latest versions (Collection 4 and 5, shortly C004 and C005) of the MODIS aerosol product over northeast Asian region. The differences between the aerosol optical thickness (AOT) from the C004 and C005 retrieval algorithms and the correlation with ground based AERONET sunphotometer observations are investigated. Over the study region, spatially averaged annual mean AOT retrieved from C005 algorithm $(AOT_{C005})$ is about 0.035 AOT (5%) less than the C004 counterparts. The linear correlations between MODIS and AERONET AOT also are R=0.89 (slope=0.86) for the C004 and R=0.95 (slope=1.00) for the C005. Moreover, the magnitude of the mean error in $AOT_{C005}$, difference between MODIS AOT and AERONET AOT, is 40% less than that in $AOT_{C004}$.

Correlation between Microstructure and Mechanical Properties of the Additive Manufactured H13 Tool Steel (적층 제조된 H13 공구강의 미세조직과 기계적 특성간의 상관관계)

  • An, Woojin;Park, Junhyeok;Lee, Jungsub;Choe, Jungho;Jung, Im Doo;Yu, Ji-Hun;Kim, Sangshik;Sung, Hyokyung
    • Korean Journal of Materials Research
    • /
    • v.28 no.11
    • /
    • pp.663-670
    • /
    • 2018
  • H13 tool steels are widely used as metallic mold materials due to their high hardness and thermal stability. Recently, many studies are undertaken to satisfy the demands for manufacturing the complex shape of the mold using a 3D printing technique. It is reported that the mechanical properties of 3D printed materials are lower than those of commercial forged alloys owing to micropores. In this study, we investigate the effect of microstructures and defects on mechanical properties in the 3D printed H13 tool steels. H13 tool steel is fabricated using a selective laser melting(SLM) process with a scan speed of 200 mm/s and a layer thickness of $25{\mu}m$. Microstructures are observed and porosities are measured by optical and scanning electron microscopy in the X-, Y-, and Z-directions with various the build heights. Tiny keyhole type pores are observed with a porosity of 0.4 %, which shows the lowest porosity in the center region. The measured Vickers hardness is around 550 HV and the yield and tensile strength are 1400 and 1700 MPa, respectively. The tensile properties are predicted using two empirical equations through the measured values of the Vickers hardness. The prediction of tensile strength has high accuracy with the experimental data of the 3D printed H13 tool steel. The effects of porosities and unmelted powders on mechanical properties are also elucidated by the metallic fractography analysis to understand tensile and fracture behavior.