• Title/Summary/Keyword: Optical Absorption and Fluorescence Spectra

Search Result 17, Processing Time 0.021 seconds

Temperature dependence of optical energy gaps and thermodynamic function of $Zn_{4}SnSe_{6}$ and $Zn_{4}SnSe_{6}:Co^{2+}$ single crystals ($Zn_{4}SnSe_{6}$$Zn_{4}SnSe_{6}:Co^{2+}$ 단결정에서 광학적 에너지 띠 및 열역학적 함수의 온도의존성 연구)

  • Kim, D.T.;Kim, N.O.;Choi, Y.I.;Kim, B.C.;Kim, H.G.;Hyun, S.C.;Kim, B.I.;Song, C.I.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.25-30
    • /
    • 2002
  • The ternary semiconducting compounds of the $A_{4}BX_{6}$(A=Cd, Zn, Hg; B=Si, Sn, Ge; X=S, Se, Te) type exhibit strong fluorescence and high photosensitivity in the visible and near infrared ranges, so these are supposed to be materials applicable to photoelectrical devices. These materials were synthesized and single crystals were first grown by Nitsche, who identified the crystal structure of the single crystals. In this paper. author describe the undoped and $Co^{2+}$-doped $Zn_{4}SnSe_{6}$ single crystals were grown by the chemical transport reaction(CTR) method using iodine of $6mg/cm^{3}$ as a transport agent. For the crystal. growth, the temperature gradient of the CTR furnace was kep at $700^{\circ}C$ for the source aone and at $820^{\circ}C$ for the growth zone for 7-days. It was found from the analysis of x-ray diffraction that undoped and $Co^{2+}$-doped $Zn_{4}SnSe_{6}$ compounds have a monoclinic structure. The optical absorption spectra obtained near the fundamental absorption edge showed that these compounds have a direct energy gaps. These temperature dependence of the optical energy gap were closely investigated over the temperature range 10[K]~300[K]

  • PDF

D-A-D type molecules based on dibenzophosphole-chalcogenides and triphenylamine moieties; effects of chalcogenide atoms on their photochemical properties

  • Iijima, Shunsuke;Hori, Keichi;Nakashima, Takuya;Kawai, Tsuyoshi
    • Rapid Communication in Photoscience
    • /
    • v.3 no.4
    • /
    • pp.61-63
    • /
    • 2014
  • 3,7-bis(4-(diphenylamino)phenyl)-5-phenyl-5H-benzo[b]phosphinedole 5-sulfide (DBPPS-TPA) and 3,7-bis(4-(diphenylamino)phenyl)-5-phenyl-5H-benzo[b]phosphinedole 5-selenide (DBPPSe-TPA) are newly synthesized D-A-D type molecules based on dibenzophospholes and their physic-chemical properties are studied in comparison with a P=O type compouond, 3,7-bis(4-(diphenylamino)-5-phenyl-5H-benzo[b]phosphinedole 5-oxide (DBPPO-TPA). Fluorescence emission and electrochemical redox properties of these compounds are investigated regarding results of density functional theory (DFT) calculations, X-ray crystallographic structures and UV-vis absorption spectra. These results exhibit systematic variation in optical properties of these compounds having P=O, P=S, and P=Se units. LUMO energy level is systematically modulated with different chalcogenide atoms.

Measurement of OH radical spectrum in counterflow burner using degenerate four wave mixing (DFWM(degenerate four wave mixing)을 이용한 대향류버너 화염내의 OH 라디칼 스펙트럼 측정)

  • 이은성;한재원
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.142-149
    • /
    • 1996
  • In non-saturation region, we measured the degenerate four wave mixing spectra of $X^2\;{\Pi}(v=0){\to}A^2{\Sigma}^+(v'=0)$ transition for OH in counterflow burner, which exists transiently in combustion reaction. We used forward box type geometry for phase matching. Calculating the population of each rotational level from the line intensities of R$_1$band and comparing it with Boltzmann distributions, we could obtain the temperatures of the flame at several points. Corrected for the absorption of incident laser fields, the final temperatures coincided with those measured by coherent anti-Stokes Raman Scattering within error $\pm$60 K near 2000 K. We also measured the concentration distribution of OH radical and it was compared to that measured by laser induced fluorescence.

  • PDF

Ho3+-Doped Amorphous Dielectrics:Emission and Excitation Spectra of the 1.6 μm Fluorescence (Ho3+ 첨가 비정질 유전체 : 1.6μm 헝광의 방출 및 여기 스펙트럼)

  • 최용규
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.8
    • /
    • pp.618-622
    • /
    • 2004
  • Excitation spectra of the 1.6 rm emission originating from $Ho^{3+}$$^{5}$ I$_{5}$ \longrightarrow$^{5}$ I$_{7}$ transition in fluoride, sulfide, and selenide glasses were measured at wavelengths around 900nm where the fluorescing $^{5}$ I$_{5}$ level is located. In specific energy range where the frequency upconversion populating $^{5}$ F$_{1}$ state happens, the excitation efficiency of the 1.6 fm emission was deteriorated in fluoride and sulfide hosts. In selenide however spectral line shapes of the excitation spectrum and the '$^{5}$ I$_{8}$ \longrightarrow$^{5}$ I$_{5}$ absorption spectrum looked seemingly identical to each other. Differences in optical nonlinearity as well as electronic band gap energy of the host glasses used are responsible for the experimental observations. On the other hand, codoping of rare earths such as Tb$^{3+}$, Dy$^{3+}$, Eu$^{3+}$, and Nd$^{3+}$ was effective in decreasint the terminating $^{5}$ I$_{7}$ level lifetime. However, at the same time, some of the codopants increased unnecessary absorption at the 1.6 $\mu$m wavelengths via their ground state absorption. Though the lifetime quenching effect of Eu$^{3+}$ was moderate, it exhibited no additional extrinsic absorption at the 1.6 $\mu$m band.EX>m band.

Prelaunch Study of Validation for the Geostationary Ocean Color Imager (GOCI) (정지궤도 해색탑재체(GOCI) 자료 검정을 위한 사전연구)

  • Ryu, Joo-Hyung;Moon, Jeong-Eon;Son, Young-Baek;Cho, Seong-Ick;Min, Jee-Eun;Yang, Chan-Su;Ahn, Yu-Hwan;Shim, Jae-Seol
    • Korean Journal of Remote Sensing
    • /
    • v.26 no.2
    • /
    • pp.251-262
    • /
    • 2010
  • In order to provide quantitative control of the standard products of Geostationary Ocean Color Imager (GOCI), on-board radiometric correction, atmospheric correction, and bio-optical algorithm are obtained continuously by comprehensive and consistent calibration and validation procedures. The calibration/validation for radiometric, atmospheric, and bio-optical data of GOCI uses temperature, salinity, ocean optics, fluorescence, and turbidity data sets from buoy and platform systems, and periodic oceanic environmental data. For calibration and validation of GOCI, we compared radiometric data between in-situ measurement and HyperSAS data installed in the Ieodo ocean research station, and between HyperSAS and SeaWiFS radiance. HyperSAS data were slightly different in in-situ radiance and irradiance, but they did not have spectral shift in absorption bands. Although all radiance bands measured between HyperSAS and SeaWiFS had an average 25% error, the 11% absolute error was relatively lower when atmospheric correction bands were omitted. This error is related to the SeaWiFS standard atmospheric correction process. We have to consider and improve this error rate for calibration and validation of GOCI. A reference target site around Dokdo Island was used for studying calibration and validation of GOCI. In-situ ocean- and bio-optical data were collected during August and October, 2009. Reflectance spectra around Dokdo Island showed optical characteristic of Case-1 Water. Absorption spectra of chlorophyll, suspended matter, and dissolved organic matter also showed their spectral characteristics. MODIS Aqua-derived chlorophyll-a concentration was well correlated with in-situ fluorometer value, which installed in Dokdo buoy. As we strive to solv the problems of radiometric, atmospheric, and bio-optical correction, it is important to be able to progress and improve the future quality of calibration and validation of GOCI.

The Output Characteristics of Flashlamp Pumped Ti:sapphire Laser Enhanced by Energy Transfer Dye (에너지 전환 방식에 의한 섬광관 펌핑 Ti$^{3+}$ : Sapphire 레이저의 발진특성)

  • 김희경
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.442-446
    • /
    • 1993
  • A flashlamp pumped Ti: sapphire laser was designed and fabricated in the laboratory. In order to find out the optimum pumping condition, three kinds of discharge circuits of which the pulse width are 10${\mu}s$, 45${\mu}s$, 65${\mu}s$ were designed. The fluorescent energy converter LD-490 of which the fluorescence spectra is coincident to the absorption band of Ti: sapphire was used to improve the laser efficiency. The laser output characteristics for three different concentrations of LD-490 and for three different pumping pulse widths were measured. As a result, the shorter the flashlamp pulse width, the higher the overall efficiency was achieved. When pumping light pulsewidth was 10${\mu}s$, the best efficiency was obtained at the concentration 1.0${\times}10^{-3}$mol/l of LD-490 dye. At lower concentrations the efficiencies were decreased.

  • PDF

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF