• 제목/요약/키워드: Optical 3D scanner

검색결과 65건 처리시간 0.028초

프린지 투영법을 이용한 실시간 3D 구강 내 스캐너의 개발 (Development of a Real-time 3D Intraoral Scanner Based on Fringe-Projection Technique)

  • ;이건수;박강
    • 한국CDE학회논문집
    • /
    • 제17권3호
    • /
    • pp.156-163
    • /
    • 2012
  • Real-time three-dimensional shape measurement is becoming increasingly important in various fields, including medical sciences, high-technology industry, and microscale measurements. However, there are not so many 3D profile tools specially designed for specifically narrow space, for example, to scan the tooth shape of a human jaw. In this paper, a real-time 3D intraoral scanner is proposed for the measurement of tooth profile in the mouth cavity. The proposed system comprises a laser diode beam, a micro charge-coupled device, a graticule, a piezoelectric transducer, a set of optical lenses, and a polhemus device sensor. The phase-shifting technique is used along with an accurate calibration method for the measurement of the tooth profile. Experimental and theoretical inspection of the phase-to-coordinate relation is presented. In addition, a nonlinear system model is developed for collimating illumination that gives the more accurate mathematical representation of the system, thus improves the shape measurement accuracy. Experiment results are presented to verify the feasibility and performance of the developed system. The experimental results indicate that overall measurement error accuracy can be controlled within 0.4 mm with a variability of ${\pm}0.01$.

3D 점군 데이터에서의 발 고유 변인 검출 시스템 설계 (Design of foot parameter measurement system in 3D Point cloud)

  • 윤정록;김운용;김회민;전성국
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2021년도 제64차 하계학술대회논문집 29권2호
    • /
    • pp.695-696
    • /
    • 2021
  • 최근 다양한 연령층과 직업군들 사이에서 기능성 신발에 대한 관심이 증대되고 있다. 그러나 기능성 신발 및 맞춤형 신발은 높은 가격대와 긴 제작 시간이 필요하다. 이러한 문제점은 3D 스캐너 도입으로 해결이 가능하나, 정확한 발 형상 측정이 가능한 3D 스캐너는 고가의 장비이기 때문에 매장별 보급이 어렵다. 본 논문은 기능성 신발의 보급을 위하여 저가형 3D 스캐너에서 정확한 발 고유 변인을 측정할 수 있는 시스템에 대해 서술한다. 이를 위해 이를 위해 저가형 Depth Camera를 이용한 저가형 3D 스캐너의 발 형상 3D 점군 데이터를 2차원으로 변형하고, 발 형태를 감싸는 최소 사각형(Min Area Rect)를 형성하여 발 안쪽점 및 발 가쪽점을 추정한다. 생성된 최소 사각형과 발 안쪽점 및 발 가쪽점 등은 발 고유 변인 측정의 기준이 된다. 실험 결과에서는 측정 기준을 이용하여 발 고유 변인인 발 길이, 발 너비, 발꿈치 너비, 발꿈치에서 발안쪽점 및 발 가쪽점 길이 등 5가지 고유 변인을 측정하는 것을 보여준다.

  • PDF

Automated 3D scoring of fluorescence in situ hybridization (FISH) using a confocal whole slide imaging scanner

  • Ziv Frankenstein;Naohiro Uraoka;Umut Aypar;Ruth Aryeequaye;Mamta Rao;Meera Hameed;Yanming Zhang;Yukako Yagi
    • Applied Microscopy
    • /
    • 제51권
    • /
    • pp.4.1-4.12
    • /
    • 2021
  • Fluorescence in situ hybridization (FISH) is a technique to visualize specific DNA/RNA sequences within the cell nuclei and provide the presence, location and structural integrity of genes on chromosomes. A confocal Whole Slide Imaging (WSI) scanner technology has superior depth resolution compared to wide-field fluorescence imaging. Confocal WSI has the ability to perform serial optical sections with specimen imaging, which is critical for 3D tissue reconstruction for volumetric spatial analysis. The standard clinical manual scoring for FISH is labor-intensive, time-consuming and subjective. Application of multi-gene FISH analysis alongside 3D imaging, significantly increase the level of complexity required for an accurate 3D analysis. Therefore, the purpose of this study is to establish automated 3D FISH scoring for z-stack images from confocal WSI scanner. The algorithm and the application we developed, SHIMARIS PAFQ, successfully employs 3D calculations for clear individual cell nuclei segmentation, gene signals detection and distribution of break-apart probes signal patterns, including standard break-apart, and variant patterns due to truncation, and deletion, etc. The analysis was accurate and precise when compared with ground truth clinical manual counting and scoring reported in ten lymphoma and solid tumors cases. The algorithm and the application we developed, SHIMARIS PAFQ, is objective and more efficient than the conventional procedure. It enables the automated counting of more nuclei, precisely detecting additional abnormal signal variations in nuclei patterns and analyzes gigabyte multi-layer stacking imaging data of tissue samples from patients. Currently, we are developing a deep learning algorithm for automated tumor area detection to be integrated with SHIMARIS PAFQ.

Improvement of Optical 3D Scanner Performance Using Atomization-Based Spray Coating

  • Valinasab, Behzad;Rukosuyev, Maxym;Lee, Jason;Ko, Junghyuk;Jun, Martin B.G.
    • 한국생산제조학회지
    • /
    • 제24권1호
    • /
    • pp.23-30
    • /
    • 2015
  • The scanning quality can be influenced by reflective abilities of a surface. Transparency and glossiness of a surface can highly limit the scanning results. Various techniques have been developed to solve problems of reflective and transparent surfaces. As one of the most feasible and convenient solutions, a thin layer of coating with proper specifications is sprayed on surface for eliminating the problems of the surfaces. As the main goal is to keep the object geometry unchanged, then it is important to coat the surface with layers less than one micrometer in thickness. For this purpose, a newly designed atomization-based spray system has been developed and tested in sets of experiments to study its efficiency on scanning results while objects with the surface are in use. This paper presents the spray design process and then studies and compares the 3D scanning results of the surfaces coated with atomization-based and aerosol sprays.

Acquisition Model for 3D Shape Measurement Data

  • Park, Jong-Sik;Jang, Wang-Jin;Lee, Seong-Beom;Park, Chan-Seok
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권4호
    • /
    • pp.16-21
    • /
    • 2008
  • The demand for three-dimensional (3D) shape measurements is increasing in a variety of fields, including the manufacture of molds and dies. The most popular technology for 3D shape measurement is the coordinate measuring machine (CMM) with a contact trigger probe. Although a CMM provides a high degree of accuracy, it is inefficient due to its long measuring time. It also has difficulty measuring soft objects that can be deformed by the touch of the contact probe. In addition, a CMM cannot digitize areas that are difficult to reach, and cannot capture very minute details on the surface of complex parts. For these reasons, optical non-contact measurement techniques are receiving more attention since they eliminate most of the problems associated with contact methods. Laser scanning is emerging as one of the more promising non-contact measurement techniques. This paper describes various acquisition considerations for laser scanning, including the accuracy of the 3D scan data, which depends on the charge-coupled device (CCD) gain and noise. The CCD gain and noise of a 3D laser scanner are varied while keeping the other conditions constant, and the measurement results are compared to the dimensions of a standard model. The experimental results show that a considerable time savings and an optimum degree of accuracy are possible by selecting the proper CCD gain and noise.

난반사 표면의 3D 스캐닝을 위한 정전분말코팅 연구 (A Study on Electrostatic Powder Coating for 3D Scanning of Diffused Surfaces)

  • 맹희영;이명상
    • 한국생산제조학회지
    • /
    • 제24권1호
    • /
    • pp.56-62
    • /
    • 2015
  • Using an optical 3D scanning device to collect data from a diffused reflection surface is very difficult. To solve this problem, there are many applications including a spray-type developer and silicon molds. However, using a developer can cause chemical reactions between objects and particles of the developer and uneven surfaces on the object. To overcome these problems, we suggest an electrostatic powder coating method for even coating of particles onto surfaces for collecting 3D shape data. We have developed an automatic, electrostatic powder-coating machine and performed three different experiments to compare this system with a laser interferometer and a T-scan 3D scanner. As a result, we could ascertain the various characteristics of this new method, including good sensitivity for the various surface states of the bare surface, developer, and electrostatic powder coating. Finally, we verified the outstanding scanning performance and were able to demonstrate that this method achieves quality than traditional methods.

매장문화재 자료에 대한 3D 디지털 기록 결과 비교연구 (A Relative Study of 3D Digital Record Results on Buried Cultural Properties)

  • 김수현;이승연;이정원;안형기
    • 헤리티지:역사와 과학
    • /
    • 제55권1호
    • /
    • pp.175-198
    • /
    • 2022
  • 기술의 발전과 더불어 다양한 형태의 아날로그 정보를 디지털로 변환하는 방법이 보편화되었다. 그 결과 디지털 유산, 디지털 재건과 같이 가상공간 내에 데이터를 기록하고 구축하여 재생산하는 개념이 정립되면서 다양한 문화유산 보존과 연구에 적극적으로 활용되고 있다. 그러나 중소형 유물에 대한 최적의 스캐너를 제시하는 기존 연구 성과는 거의 없는 실정이다. 또한 스캐너 가격도 연구자들이 활용하기에는 저렴하지 않아 관련 연구가 많지 않다. 3D 스캐너 사양은 3D 모델 품질에 큰 영향을 끼친다. 특히 스캐너에서 사용되는 광원의 종류에 따라 물체 표면에서 반사되는 빛의 상태가 상이하므로 객체의 특성에 적합한 스캐너를 사용하는 것이 작업의 효율성을 올릴 수 있는 방법이다. 따라서 본고에서는 시기별 토기와 자기를 비롯한 다양한 재질의 중소형 매장문화재 9점을 대상으로 연구를 진행하여 네 가지 방식의 3D 스캐너가 어떠 품질 차이가 있는지 살펴보고자 하였다. 연구 결과 중소형 유물의 디지털 기록은 광학식 스캐너와 중소형 오브젝트 스캐너가 가장 적합하였다. 광학식 스캐너는 메시와 텍스처 모두 우수하나, 가격이 매우 높으며 휴대성이 떨어진다는 단점이 있다. 핸드헬드 방식은 휴대성과 신속성이 뛰어나다는 장점이 있었다. 가격 대비 결과물을 고려할 때는 중소형 오브젝트 스캐너가 가장 우수하였다. 가장 저렴한 비용으로 3D 모델을 획득할 수 있었던 것은 사진실측이었다. 3D 스캐닝 기술은 크게 유물의 디지털 도면 제작, 문화재 복원 및 복제, 데이터베이스 구축 방면으로 활용할 수 있다. 본 연구는 문화유산에서 3D 스캐닝 기술의 적극적인 활용을 위해 재질별, 시대별 매장문화재 유물에 가장 적합한 스캐너를 이용할 수 있도록 기여하였다는 데에 의의가 있다.

Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluations

  • Bi, Chuang;Wang, Xingyu;Tian, Fangfang;Qu, Zhe;Zhao, Jiaming
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권4호
    • /
    • pp.236-249
    • /
    • 2022
  • PURPOSE. The present study compared the accuracy between digital and conventional implant impressions. MATERIALS AND METHODS. The experimental models were divided into six groups depending on the implant location and the scanning span. Digital impressions were captured using the intraoral optical scanner TRIOS (3Shape, Copenhagen, Denmark). Conventional impressions were taken with the monophase impression material based on addition-cured silicones, Honigum-Mono (DMG, Hamburg, Germany). A high-precision laboratory scanner D900 (3Shape, Copenhagen, Denmark) was used to obtain digital data of resin models and stone casts. Surface tessellation language (STL) datasets from scanner were imported into the analysis software Geomagic Qualify 14 (3D Systems, Rock Hill, SC, USA), and scan body deviations were determined through two-dimensional and three-dimensional analyses. Each scan body was measured five times. The Sidak t test was used to analyze the experimental data. RESULTS. Implant position and scanning distance affected the impression accuracy. For a unilateral arch implant and the mandible models with two implants, no significant difference was observed in the accuracy between the digital and conventional implant impressions on scan bodies; however, the corresponding differences for trans-arch implants and mandible with six implants were extremely significant (P<.001). CONCLUSION. For short-span scanning, the accuracy of digital and conventional implant impressions did not differ significantly. For long-span scanning, the precision of digital impressions was significantly inferior to that of the traditional impressions.

구면좌표계식 기구를 이용한 인공치아의 3차원 측정시스템 개발 (Development of 3D Measuring System for Artificial Pontic using Spherical Coordinate System Mechanism)

  • 맹희영;성봉현
    • 한국생산제조학회지
    • /
    • 제19권4호
    • /
    • pp.427-433
    • /
    • 2010
  • With recent increased demand for reverse engineering in dental machining, the 3D laser scanner is widely used for inspection of artificial pontic. In order to overcome the optical drawback of laser scanner, such as irregular scatter, direction of beam, and the influence of surface integrity, it is developed in this study a new 3D measuring system for artificial pontic using spherical coordinate system mechanism by point laser sensor, which keeps the direction of beam normal to surface consistently. The comprehensive integrated system is established to evaluate the improvement of accuracy with data acquisition system. The experimental results for measuring a master ball and pontic models shows the excellent form accuracy and repeatability compared with conventional apparatus. Also, these results shows the possibility to apply this system for the measuring purpose within 0.05mm accuracy of pontic at the sharp edge or margin contour, which was difficult to measure at the conventional systems.

Digital Micromirror Device와 Polygon scanner의 Lithography 특성에 따른 산업적 분석 (Industrial analysis according to lithography characteristics of digital micromirror device and polygon scanner)

  • 김지훈;박규백;박정래;고강호;이정우;임동욱
    • Design & Manufacturing
    • /
    • 제15권4호
    • /
    • pp.65-71
    • /
    • 2021
  • In the early days of laser invention, it was simply used as a measuring tool, but as lasers became more common, they became an indispensable processing tool in the industry. Short-wavelength lasers are used to make patterns on wafers used in semiconductors depending on the wavelength, such as CO2 laser, YAG laser, green laser, and UV laser. At first, the hole of the PCB board mainly used for electronic parts was not thin and the hole size was large, so a mechanical drill was used. However, in order to realize product miniaturization and high integration, small hole processing lasers have become essential, and pattern exposure for small hole sizes has become essential. This paper intends to analyze the characteristics through patterns by exposing the PCB substrate through DMD and polygon scanner, which are different optical systems. Since the optical systems are different, the size of the patterns was made the same, and exposure was performed under the optimal conditions for each system. Pattern characteristics were analyzed through a 3D profiler. As a result of the analysis, there was no significant difference in line width between the two systems. However, it was confirmed that dmd had better pattern precision and polygon scanner had better productivity.