• Title/Summary/Keyword: Optic system

Search Result 785, Processing Time 0.032 seconds

Analysis of Dynamic Characteristics in a Fiber Optic Gyro (광파이버 자이로의 동특성 해석)

  • Jung, S.;Kwon, Y.S.;Kim, S.J.;Lee, S.S.;Jin, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.80-82
    • /
    • 1997
  • An analytical study of the Dynamic Characteristics of a Fiber Optic Gyro is presented. A mathematical model appropriate to the Fiber Optic Gyro system suffering from the system vibration of a driving motor is derived. It is shown that the analysis is directly applicable to the Gyrocompass system.

  • PDF

The Study of in Vivo Visual Pathway Tracing using Magnetic Magnanese Tracer (자성 망간 추적자를 이용한 in Vivo 시신경경로 추적에 관한 연구)

  • Bae, Sung-Jin;Chang, Yong-Min
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.42-47
    • /
    • 2007
  • Purpose: To evaluate the tracing of optic nerve tract using manganese enhanced magnetic resonance Imaging. Materials and Methods: After injecting $30{\mu}l$ of $MnCl_2(1mol)$ (1 mol) Into the retina of female New Zealand white rabbit, the contrast enhancements at major anatomical structures of optic nerve tract were evaluated by high resolution T1-weighted Images 12 hours, 24 hours, and 48 hours after $MnCl_2(1mol)$ Injection using 3D FSPGR (Fast Speiled Gradient Recalled echo) pulse sequence at 1.5T clinical MR scanner with high performance gradient system. Also, for quantitative evaluation, the signal-to-noise ratios of circular ROI on anatomical locations were measured. Results: The major structures on the optic nerve tract were enhanced after injecting $MnCl_2(1mol)$. The structures, which showed enhancement, were right optic nerve, optic chiasm, left optic tract, left lateral geniculate nucleus, left superior colliculus. The structures on the contralateral optic pathway to the right retina were enhanced whereas the structures on the ipsilateral pathway did not show enhancement. Conclusion: The Mn transport through axonal pathway of optic nerve sys)em was non- invasively observed after injecting injecting $MnCl_2$ at the retina, which is the end terminal of optic nerve system. This Mn transport seems to occur by voltage gated calcium $(Ca^{2+})$ channel and In case of direct Injection Into the retina, the fast transpori pathway of voltage gated calcium channel seems to be responsible for Mn transport.

  • PDF

An Experimental Study on the Tappet Spin for a Direct Acting Valve Train System (직접 구동형 밸브 트레인 시스템의 태핏 회전에 관한 실험적 연구)

  • Cho, Myung-Rae;Kim, Hyung-Jun;Moon, Tae-Seon;Han, Dong-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.7
    • /
    • pp.1179-1184
    • /
    • 2003
  • The technique for measuring the rotational speed of tappet in direct acting type valve train system has been developed. The optic signal monitoring system with laser and optic fiber was designed to follow the signal of tappet rotation. The system was based on ON/OFF signal generation from the additional encoder teeth under the tappet with optic fibers attached photo transistor. The data showed that tappet rotation was affected by offset, oil temperature and cam shaft operating speed. Also it was found that tappet rotation increases with oil temperature. Tappet spin was delayed 10∼s20$^{\circ}$ cam angle after valve opening. The instantaneous rotational speed of tappet was reciprocal to cam shaft speed and the tappet and the cam angle ratio was located in the range of 0.1∼0.3.

Design of Algorithm for maximum Signal Sensing by Optical System (광시스템에서 maximum 신호 Sensing을 위한 Algorithm 설계)

  • Choi, Do-Sun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.4
    • /
    • pp.70-75
    • /
    • 2010
  • In this paper, was designed Algorithm Brent. this Algorithm can be used in the medical optical system. Optical signals are transmitted using optical fibers and integrated Optic. Developed Algorithm finds the maximum of the transmitted signal intensity. Optical system is made for Laser-Diode, HeNe-Laseer, controller for stepping motor, glass fiber and integrated Optic, etc. In this paper, two algorithms were investigated.

  • PDF

Study on Cure Monitoring for Epoxy Resin Using Fiber Optic Sensor System (광섬유 센서를 이용한 에폭시 수지의 경화도 측정)

  • Kim, J.B.;Byun, J.H.;Lee, C.H.;Lee, S.K.;Um, M.K.
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.37-41
    • /
    • 2005
  • The curing of thermoset resin is accompanied with the changes in chemical and physical properties. The cure monitoring techniques can be designed by tracing these property changes. This paper presents the cure monitoring technique with fiber optic sensors to detect the change of refractive index during the polymerization process of engineering epoxy resin. The fiber optic sensor system was developed to measure the reflection coefficient at the interface between the fiber optic and the resin. The correlation between the sensor output and the degree of cure was performed following Lorentz-Lorenz law. The isothermal data from the sensors are compared with the data from differential scanning calorimeter.

  • PDF

A Study on the Design of Fish-Eye Optic for Automotive Stop Light (자동차용 제동등을 위한 FISH-EYE OPTIC 설계에 관한 연구)

  • 임지만;이정환;서명원
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.6
    • /
    • pp.231-240
    • /
    • 1999
  • The most important thing to be considered in designing stop lamps for automobiles is to satisfy the photometric requirement in various countries and achieve the equal image. To meet these requirements, parabolic reflector and fish-eye optics has been widely applied. The form of the embodied optic is most important in satisfying the photometric requirement and achieving the equal image because the impact of fish-eye optic is decisive. In this study, a series of researches has been performed to optimize of the fish-eye optic by analyzing beam pattern through the photometric simulation based on CATAI program. The optimized results have been shown to meet the various photometric requirements including non dazzling condition considering the following car. The methodology of this study is excepted to influence the development procedure of light system. The time and cost for the system development would be greatly saved by suing this simulaion technique.

  • PDF

Design of Distributed Fiber Optic Sensor Net for the Detection of External Sound Frequency (외부 음향 주파수 탐지를 위한 분포형 광섬유 센서망 설계)

  • 이종길
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.792-796
    • /
    • 2003
  • In this paper, to detect external sound frequency on the latticed structure, fiber optic sensor net using Sagnac interferometer was fabricated and tested. The latticed structure fabricated with dimension of 50cm in width and 50cm in height, the optical fiber, 50m in length, distributed and fixed on the latticed structure. Single mode fiber, a laser with 1,550nm in wavelength, 2${\times}$2 coupler were used. External sound signal applied to the fiber optic sensor net and the detected optical signals were compared and analyzed to the detected microphone signals against time and frequency domain. Based on the experimental results, fiber optic sensor net using Sagnac interferometer detected external sound frequency, effectively. This system can be expanded to the structural health monitoring system.

  • PDF

Detection of External Sound Frequency by Using the Distributed Fiber Optic Sensor Net (분포형 광섬유 센서망을 이용한 외부 음향 주파수 탐지)

  • 이종길
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.7
    • /
    • pp.569-576
    • /
    • 2004
  • In this paper, to detect external sound frequencies on the latticed structure, fiber optic sensor net using Sagnac interferometer was fabricated and tested. The latticed structure was fabricated with a dimension of 50 cm in width and 50 cm in height. The optical fiber of 50m in length was distributed and fixed on the surface of the latticed structure. Single mode fiber, a laser with 1,550 nm in wavelength, 2 ${\times}$ 2 coupler were used. External sound signal, 240 Hz, 495 Hz, 1.445 kHz, 2k Hz, applied to the fiber optic sensor net and the detected optical signals were compared to the detected microphone signals against time and frequency domains. Based on the experimental results, fiber optic sensor net using Sagnac interferometer detected external sound frequency, effectively. This system can be expanded to the structural health monitoring system.

A Study on a Multi-channel Fiber Optic Hydrophone System (다채널 광섬유 하이드로폰 배열 시스템에 관한 연구)

  • 김정석
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.7
    • /
    • pp.89-93
    • /
    • 2001
  • In recent years Fiber optic hydrophone systems have been the focus of much attention in the sonar world. For sonar arrays, a fiber optic approach offers the major benefit of passive multiplexing of large numbers of hydrophones without underwater electronics. This paper describes recent development work covering array construction, opto-electronics development, hydrohpone design and sea trials. And the development of an interferometric mult-channel fiber optic hydrophone system which uses time division multiplexing capable of driving in excess of 32 channel is described. For this, a 12 channel time division multiplexing array has been constructed, and the performance of this system is demonstrated by sea trial.

  • PDF

Analysis of Fiber-optic Link Budget for Optically fed Wireless Communication

  • Kim, Jung-Tae
    • Journal of information and communication convergence engineering
    • /
    • v.1 no.1
    • /
    • pp.35-38
    • /
    • 2003
  • Analyses of performance of wireless broadband communication systems employing fiber-optic link have presented. We have analyzed CNR penalty to evaluate system performance by taking into account, radio link considering rainfall attenuation, and optical link considering several carrier-to-noise ratio versus the optical modulation index.