• 제목/요약/키워드: Optic lens

Search Result 100, Processing Time 0.019 seconds

Structural and Optical Characteristics of ChalcogenideGe_Sb_Se for Basic Aspheric Lens Design (비구면렌즈 설계를 위한 칼코게나이드 Ge-Sb-Se계 구조적, 광학적 특성 연구)

  • Ko, Jun Bin;Myung, Tae Sik
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.2
    • /
    • pp.133-137
    • /
    • 2014
  • The recent development of electro-optic devices and anticorrosion media has made it necessary investigate infrared optical systems with solid-solid interfaces of materials with amorphous characteristics. One of the most promising classes of materials for these purposes seems to be chalcogenide glasses, which are based on the Ge_Sb_Se system, have drawn much attention because of their use in preparing optical lenses and fibers that are transparent in the range of 3-12 um. In this study, a standard melt-quenching technique was used to prepare amorphous Ge_Sb_Sechalcogenideto be used in the design and manufacture of infrared optical products. The results of structural, optical, and surface roughness analyses of high purity Ge_Sb_Sechalcogenide glasses after various annealing processes reported.

Chalcogenide Ge-Sb-Se Optical and Crystallization Characteristics for Basic a Planning Aspheric Lens (비구면렌즈 설계를 위한 칼코게나이드 Ge-Sb-Se 광학계 및 결정화 특성 연구)

  • Myung, Tae Sik;Ko, Jun Bin
    • Korean Journal of Materials Research
    • /
    • v.26 no.11
    • /
    • pp.598-603
    • /
    • 2016
  • The recent development of electro-optic devices and anticorrosion media has led to the necessity to investigate infrared optical systems with solid-solid interfaces of materials that often have the characteristic of amorphousness. One of the most promising classes of materials for those purposes seems to be the chalcogenide glasses. Chalcogenide glasses, based on the Ge-Sb-Se system, have drawn a great deal of attention because of their use in preparing optical lenses and transparent fibers in the range of 3~12 um. In this study, amorphous Ge-Sb-Se chalcogenide for application in an infrared optical product design and manufacture was prepared by a standard melt-quenching technique. The results of the structural, optical and surface roughness analysis of high purity Ge-Sb-Se chalcogenide glasses are reported after various annealing processes.

The Necessity and Requirement of Trial Lens Set Standardization (검안렌즈 표준화의 필요성과 규격에 관한 연구)

  • Park, Sang-Yeul
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.217-223
    • /
    • 2006
  • The purpose of this study is to provide improvements and standards of trial lens, in a situation that there is a lack of standards of trial lens set that have been used for self-conscious refraction test after helm refraction test at about 5,000 opticians, ophthalmologic clinics and hospitals, and contact-lens shops, that there is a lot of discrepancies between refraction specified and the actual power, and that there is no regulation of optical tolerance error. For the study, opticians who have used Trial lens set were asked to participate in a questionnaire survey through continuing education, and divided into those who have used domestic lens and those who have used imported lens, 5 opticians each for less than 5 years, 5 to 10 years, more than 10 years. The measurement of both refraction specified and the actual diopter was compared to Japan Industrial Standards(JIS T4402). As a result of comparative analysis, more than 80% of respondents have had reliability on the refraction of trial lens they had used, indicating that they have never measured the refraction specified and the actual diopter after buying them. Besides, Korean Industrial Standards(KS P4402) has been imperfect in diopter range since it was legislated in 1979. More than 95% of respondents have been unsatisfied with optometry. Also, it has indicated that refraction error is more frequent in long-term-used trial lens. The conclusion is that it is necessary to standardize trial lens set and that it is required to add lens to lens set provided under KS P4402. Moreover, it is necessary to have supervisory agency for a standardization of trial lens. I hope that both domestic lens and imported lens, as in German and Japan, will be tested to find whether they meet optical tolerance error and standard trial lens will be distributed. Good optic inspection is required for the improvement and management of eye health and optical function, and the same standard trial lens set should be used. whoever is tested. Also, I hope that trial lens set will be specified within standards and tolerance error.

  • PDF

The Change of the Phoria in Accordance with the Color and Concentration of the Color Lens (착색렌즈의 색상과 농도에 따른 원거리 사위도의 변화)

  • Choi, Hyun-Soo;Park, Sung-Jong;Lee, Seok-Ju;Jin, Moon-Seok;Jun, Jin;Ryu, Geun-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.339-343
    • /
    • 2011
  • Purpose: In this study, we investigated changes of phoria based on varying the color and concentration of the color in lenses. Methods: We measured distance phoria for 39 students who aged 20 to 40 with different concentrated lenes - red, gray, brown and green lenses in concentration 20%, 50% and 80%, respectively. Results: Subjects were divided into three groups which were orthophoria, esophoria and exophoria. Orthophoria in all the color and concentration, there were a few of the esophoria. Esophoria of average 2.07${\Delta}$,B.O showed that a slight increase in all colors and concentration, especially in brown lenses showed the greatest increase. Exophoria of average 3.82${\Delta}$,B.I showed that a slight decrease in all colors and concentration, especially in green lenses showed to 2.95${\Delta}$,B.I to the greatest decrease. Different concentration in same color had no specific tendency regarding phoria. Conclusions: The phoria must be considered when selecting color of the lens because of phoria is changeable by color of the lens. It is expected to study the criteria that minimize the asthenopia.

A Study on a Changed Power of Tear lens at Spherical RGP lens Fitting (구면 RGP렌즈 Fitting시 누액렌즈 굴절력 변화에 대한 연구)

  • Park, Seong-Jong;Joo, Seok-Hee;Jung, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.455-462
    • /
    • 2004
  • In this paper, we measured and analysised the power change of tear lens for 85 patients - 170 myopia eyes - who are fitted using RGP lens, considering the BGR of RGP lens, the corneal astigmatism power, and corneal curvature. We got the following results from these experiments; 1. When the BCR of RGP lens changes, the diopters of tear lens of "on-k", 0.05Pt, 01.0Ft, 0.05St, and 0.10St are -0.25D, -0.46D, -0.63D, +0.07D, and +0.26D, respectively. 2. When the corneal astigmatism power changes, the diopters of tear lens of group below 0.75D, group of 1.00D~1.25D, group of 1.50D~1.75D, and group over 2.00D in "on-k" state, are -0.25D, -0.18D, -0.09D, and -0.39D, respectively. 3. When the corneal astigmatism power changes and the BCR of test lens is changed by 0.05mm step, the change values of tear lens diopter for 0.05St and 0.05Ft approximate to ${\pm}0.25D$, while these for 0.10St and 0.10Ft don't approximate to the value below ${\pm}0.25D$.[are irregular value below ${\pm}0.25D$.] 4. When the corneal curvature and the HCR of RGP lens change, the diopters of tear lens of group below 7.50mm, group of 7.55~7.80mm, group of 7.85~8.20mm, and group over 8.25mm in "on-k" state, are -0.40D, -0.11D, -0.20D, and -0.19D, respectively. 5. When the BCR of test lens is changed by 0.05mm step and the corneal curvature increases, the change values of tear lens diopter decrease, while these over 8.25mm are mean value ${\pm}0.17D$ and the value below ${\pm}0.25D$.

  • PDF

A Study of the Retina Image Controllability using a Sledge (망막 영상 조절 장치에 관한 연구)

  • 이숙희;이영춘;양연식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.273-276
    • /
    • 1997
  • Seeing is an intelligent act. Retina is the most important part among the components of eye which is comprised of iris, pupil, lens, optic disk, and so forth. Because retina acts like a photo receiver to detect light from every object, if damaged, animals have a severe problem to live along with themselves and sometimes they lose their sight. In the ophthalmology, doctors use special instrument to see exact retina image of object and operate the surgery by rotating focus control knob. In this study, a basic test is done to achieve the auto focus control instrument. Specially made sledge and attenuator are installed on the optic bed to change the distance and laser power between the first reflective mirror and the second one. Control panel which is compiled by Visual C t t to control stepping motors ,laser power and photodiode are implemented with ADA-board.

  • PDF

Laser Beam Shaping Using Hollow Optical Fiber and Its Application in Laser Induced Thermal Printing

  • Yi, Jong-Hoon;Lee, Kang-In;Park, Ill-Hyun;Kwon, Jin-Hyuk
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.146-151
    • /
    • 2009
  • A Gaussian beam of single mode fiber laser was changed into a ring-shaped pattern after it was transmitted through the hollow optical fiber. The ring-shaped beam was focused on a plane by an f-. lens and it was scanned by a Galvano-mirror. The spatial profile of laser energy incident on a plane had two peaks at both sides of the scanned linear track. The profile was compared with the result obtained when the Gaussian beam was dithered transversely by an acousto-optic modulator. It is found that hollow optical fiber beam shaper can replace acousto-optic beam dithering device which is employed in a laser induced thermal printing system.

Inherited Metabolic Disorders Involving the Eye (유전성대사질환에서 눈이상)

  • Jae Ho, Jung
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.22 no.2
    • /
    • pp.37-45
    • /
    • 2022
  • Inherited metabolic disorders (IMD) are a large group of rare disorders affecting normal biochemical pathways. The ophthalmic involvement can be very varied affecting any part of the eye, including abnormalities of cornea, lens dislocation and cataracts, retina and the optic nerve, and extraocular muscles. Eye disorders can be initial symptoms of some IMD and can be clue for diagnosis of IMD. However, eye disorders can evolve later in the natural history of an already diagnosed metabolic disorder. Awareness of IMDs is important to facilitate early diagnosis and in some cases instigate early treatment if a patient presents with eye involvement suggestive of a metabolic disorder. Ophthalmological interventions are also an important component of the multisystem holistic approach to treating patients with metabolic disorders.

Optical Cap Sensor for Magneto-Optic Near-Field Recording (MO 근접장 기록을 위한 광학 갭 센서)

  • Yoon, Yong-Joong;Park, Jae-Hyuk;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.3
    • /
    • pp.245-250
    • /
    • 2004
  • This paper proposes a new method of measuring an air interface distance between a solid immersion lens(SIL) applied magneto-optic technology and the disk surface. For applying near-field recording (NFR) technology to the magneto-optic storage devices for the next generation, it is positively necessary to maintain the small air gap under about 100㎚. We design an apparatus that consists of some optical components such as a prism, a polarizer and an analyzer. By using the Fresnel reflection coefficient equation, Jones matrices calculation and Malus's law, we establish a mathematical model for understanding the characteristics of the system. The simulations are based on the mathematical model and through the simulation results which is made with various cases we can estimate the performance of the new optical gap sensor system. Experimental results, which are also based on the mathematical model for specific cases, are in good agreement with simulated ones and demonstrate the possibility as the new optical gap sensor.

The Developement of Secondary Optics Design Method for LED (LED 2차 광학 시스템의 설계법 개발)

  • Jung, Seung-Gyun;Seok, Dae-Il;Shin, Hwa-Young;Lee, Chang-Mo;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.6
    • /
    • pp.26-32
    • /
    • 2007
  • Design methods of LED optic system includes point source assumption and imaginary focus approaches. However, these methods make significant error if the position of LED approachs that of optic system. This paper suggests a new design approach that LED is equally divided, light distribution of each division is predicted and confirmed through reverse tracing of light wave, and then each divided segment is separately designed, Using new design method, two kinds of example optic system were designed and light distribution and efficiency of the systems were evaluated.