• 제목/요약/키워드: Optic

검색결과 2,438건 처리시간 0.032초

Applications of fiber optic sensors in civil engineering

  • Deng, Lu;Cai, C.S.
    • Structural Engineering and Mechanics
    • /
    • 제25권5호
    • /
    • pp.577-596
    • /
    • 2007
  • Recent development of fiber optic sensor technology has provided an excellent choice for civil engineers for performance monitoring of civil infrastructures. Fiber optic sensors have the advantages of small dimensions, good resolution and accuracy, as well as excellent ability to transmit signal at long distances. They are also immune to electromagnetic and radio frequency interference and may incorporate a series of interrogated sensors multiplexed along a single fiber. These advantages make fiber optic sensors a better method than traditional damage detection methods and devices to some extent. This paper provides a review of recent developments in fiber optic sensor technology as well as some applications of fiber optic sensors to the performance monitoring of civil infrastructures such as buildings, bridges, pavements, dams, pipelines, tunnels, piles, etc. Existing problems of fiber optic sensors with their applications to civil structural performance monitoring are also discussed.

X-band Microwave Photonic Filter Using Switch-based Fiber-Optic Delay Lines

  • Jung, Byung-Min
    • Current Optics and Photonics
    • /
    • 제2권1호
    • /
    • pp.34-38
    • /
    • 2018
  • An X-band microwave photonic (MWP) filter using switch-based fiber-optic delay lines has been proposed and experimentally demonstrated. It is composed of two electro-optic modulators (EOMs) and $2{\times}2$ optical MEMS-switch-based fiber-optic delay lines. By changing time-delay difference and coefficients of each wavelength signal by using fiber-optic delay lines and an electro-optic modulator, respectively, a bandpass filter or a notch filter can be implemented. For an X-band MWP filter with four channel elements, fiber-optic delay lines with the unit time-delay of 50 ps have been experimentally realized and the frequency responses corresponding to the time-delays has been measured. The measured frequency response error at center frequency and the time-delay difference error were 180 MHz at 10 GHz and 3.2 ps, respectively, when the fiber-optic delay line has the time-delay difference of 50 ps.

광전류/광전압 센서의 일체화 설계에 관한 연구 (A study on single body design of optical current sensor and optical voltage sensor)

  • 김영수;김요희
    • 한국통신학회논문지
    • /
    • 제21권6호
    • /
    • pp.1596-1603
    • /
    • 1996
  • A single body type of fiber-optic current and voltae sensor using a rare earth doped YIG and a bismuth silicon oxide single crystsl is proposed, which is used for simultaneous measurement of the AC electric current and AC electric voltage over the trasmission lines. Experimental results showed that the fiber-optic current sensor has the maximum 7.5% error within the current range of 0A to 400A, and the fiber-optic voltage sensor has the maximum 0.87% error within the current range of 0V to 400V. The output waveforms of proposed fiber-optic sensor system has a good agreement with output waveforms of conductor current and voltage. Experimental results proved that the output of fiber-optic current sensor is not affected by the electric voltage applied to the fiber-optic voltage sensor, and also, that the output of fiber-optic voltage sensor is not affected by the electric current applied to the fiber-optic current sensor.

  • PDF

IOC를 사용한 광파이버 자이로 (Fiber Optic Gyroscope using IOC)

  • 김인수;김요희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1843-1845
    • /
    • 1998
  • Gyroscope is a very important core sensor as a rotation sensor in inertial space, in inertial guidance and navigation system on aeronautics. Plane, vessel and so on for civilian and millitary applications. Research and development of fiber optic gyroscope began in 1976 and focused on improving the gyroscope's sensitivity to rotation. bias performance and reducing noise. We have developed a Interferometric Fiber Optic' Gyroscope using a integrated-optic-circuit (IOC), which is operating with closed-loop electronic circuit. This paper describes the scheme of optical part and electronic part and also test results of this fiber optic gyroscope using a integrated-optic-circuit (IOC). The performance have been achieved as long-term bias drift of $1.73^{\circ}/h$.

  • PDF

A Fiber Optic Sensor for Determination of 2,4-Dichlorophenol Based on Oxygen Oxidation Catalyzed by Iron(III) Tetrasulfophthalocyanine

  • Tong, Yilin;Li, Dapeng;Huang, Jun;Zhang, Cong;Li, Kun;Ding, Liyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권11호
    • /
    • pp.3307-3311
    • /
    • 2013
  • A new fiber optical sensor was developed for the determination of 2,4-dichlorophenol (DCP). The sensor was based on DCP oxidation by oxygen with the catalysis of iron(III) tetrasulfophthalocyanine (Fe(III)PcTs). The optical oxygen sensing film with $Ru(bpy)_3Cl_2$ as the fluorescence indicator was used to determine the consumption of oxygen in solution. A lock-in amplifier was used for detecting the lifetime of the oxygen sensing film by measuring the phase delay change of the sensor head. The different variables affecting the sensor performance were evaluated and optimized. Under the optimal conditions (i.e. pH 6.0, $25^{\circ}C$, Fe(III)PcTs concentration of 0.62 mg/mL), the linear detection range and response time of the sensor are $1.0{\times}10^{-6}-9.0{\times}10^{-6}$ mol/L and 250 s, respectively. The sensor displays high selectivity, good repeatability and stability, and can be used as an effective tool in analyzing DCP concentration in practical samples.

외상성 시신경병증의 시신경 감압술을 통한 치험례 (Optic Nerve Decompression for Traumatic Optic Neuropathy: A Case Report)

  • 현경배;김선호;최종우;김용욱;박병윤
    • Archives of Plastic Surgery
    • /
    • 제32권3호
    • /
    • pp.389-392
    • /
    • 2005
  • A case of visual loss following cranio-maxillofacial trauma is reported. The patient had acute optic nerve injury associated with a fracture of the right zygomaticomaxillary and fronto-naso-ethmoido-orbital bone and epidural hematoma on the right temporal lobe of brain. Bony fragments compressing the optic nerve on lateral side was identified on computed tomography. Decompression of the optic nerve combined with evacuation of epidural hematoma has been performed via transfrontal craniotomy. The patient had complete recovery of visual acuity without any complications. The role of optic nerve decompression in the management of patients with traumatic optic neuropathy is discussed. Surgical indication is controversial and the procedure should be considered only within the context of the specific indication of the individual patient.

Optic nerve sheath meningioma mimicking optic perineuritis

  • Sohyeon Kim;Minsung Kang;Jin-Sung Park;Hung Youl Seok
    • Annals of Clinical Neurophysiology
    • /
    • 제25권1호
    • /
    • pp.50-53
    • /
    • 2023
  • Tram-track and doughnut-shaped enhancements of the optic nerve sheath in axial and coronal magnetic resonance imaging (MRI) views, respectively, play crucial roles in the diagnosis of optic nerve sheath meningioma (ONSM). However, this finding is not specific to ONSM since it can also be observed in optic perineuritis (OPN). Here we report a 42-year-old female with ONSM who presented with clinical and MRI findings similar to those of OPN.

생물공정 모니터링을 위한 Fiber Optic 생물센서 개발

  • 손옥재;이종일
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2001년도 추계학술발표대회
    • /
    • pp.819-822
    • /
    • 2001
  • In this study a fiber optic biosensor has been developed to on-line monitor the concentrations of oxygen and glucose. The oxygen concentrations in solution and gas phase monitored by the fiber optic sensor has been compared with those by a dissolved oxygen electrode and an IR-type $O_2$ analyzer. The fiber optic glucose sensor has been made by immobilizing glucose oxidase on the tip of the optic fiber and used to on-line monitor the concentration of glucose in a fermentation process.

  • PDF

측정대상물의 표면조도에 따른 광파이버 센서 특성고찰 (The Characteristics of Fiber Optic Sensor on the Surface Roughness of Target)

  • 박한수;정택구;홍준희;이동주
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.283-286
    • /
    • 2002
  • In fiber optic sensor, the error of the measurement is influenced by the surface roughness of the target and surroundings, especially the outside light. To reduce or modify this error, the sensitivity of the fiber optic sensor and the noise change by the surface roughness of the target should be known. The purpose of this paper is to observe the sensitivity of the fiber optic sensor and the noise according to the surface roughness of the target.

  • PDF

선형 Optic flow 알고리듬을 이용한 이동 로봇 제어 (Control of mobile robots based on a linear optic-flow algorithm)

  • 최대일;한웅기;국태용
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1149-1152
    • /
    • 1996
  • Recently visual servo control is an important feature of an intelligent robot system. In this paper, we presents a Kalman filter approach for estimation of the linear optic flow model which is utilized in the visual servoing of a mobile robot. The proposed method is also compared with the conventional least mean square method via computer simulation.

  • PDF