• Title/Summary/Keyword: Operator failure

Search Result 131, Processing Time 0.029 seconds

Development of Event Corrective Action Supporting System (ECAS) in Nuclear Power Plant (원전 사고처리 지원시스템(ECAS) 개발)

  • Choi, Young Hwan;Kim, Yopng Mi;Ko, Han Ok
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.5 no.2
    • /
    • pp.40-44
    • /
    • 2009
  • In this study, Event Corrective Action Supporting System (ECAS) is developed for the accident evaluation in nuclear power plant. The ECAS system can be used in supporting regulator and/or operator under event situation in nuclear power plants. The ECAS system consists of 5 modules including failure location module, failure analysis module, failure integrity evaluation module, system vulnerability evaluation module, and reporting and operating experience feedback module. The ECAS system will be used as sub module of Knowledge-Based Event Evaluation Network (K-EvENT) which is developing for the against the accident in nuclear power plants.

  • PDF

A Safety Assessment Methodology for a Digital Reactor Protection System

  • Lee Dong-Young;Choi Jong-Gyun;Lyou Joon
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.1
    • /
    • pp.105-112
    • /
    • 2006
  • The main function of a reactor protection system is to maintain the reactor core integrity and the reactor coolant system pressure boundary. Generally, the reactor protection system adopts the 2-out-of-m redundant architecture to assure a reliable operation. This paper describes the safety assessment of a digital reactor protection system using the fault tree analysis technique. The fault tree technique can be expressed in terms of combinations of the basic event failures such as the random hardware failures, common cause failures, operator errors, and the fault tolerance mechanisms implemented in the reactor protection system. In this paper, a prediction method of the hardware failure rate is suggested for a digital reactor protection system, and applied to the reactor protection system being developed in Korea to identify design weak points from a safety point of view.

An Application of the HRA Methodology in PSA: A Gas Valve Station (PSA의 인간신뢰도분석 모델의 적용)

  • 제무성
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.4
    • /
    • pp.150-156
    • /
    • 2000
  • In this paper, the human error contributions to the system unavailability are calculated and compared to the mechanical failure contributions. The system unavailability is a probability that a system is in the failed state at time t, given that it was the normal state at time zero. It is a function of human errors committed during maintenance and tests, component failure rates, surveillance test intervals, and allowed outage time. The THERP (Technique for Human Error Rate Prediction), generally called "HRA handbook", is used here for evaluating human error rates. This method treats the operator as one of the system components, and human reliability is assessed in the same manner as that of components. Based on the calculation results, the human error contribution to the system unavailability is shown to be more important than the mechanical failure contribution in the example system. It is also demonstrated that this method is very flexible in that it can be applied to any hazardous facilities, such as gas valve stations and chemical process plants.ss plants.

  • PDF

An Experimental Study on Fault Detection and Diagnosis Method for a Water Chiller Using Bayes Classifier (베이즈 분류기를 이용한 수냉식 냉동기의 고장 진단 방법에 관한 실험적 연구)

  • Lee, Heung-Ju;Chang, Young-Soo;Kang, Byung-Ha
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.36-41
    • /
    • 2008
  • Fault detection and diagnosis(FDD) system is beneficial in equipment management by providing the operator with tools which can help find out a failure of the system. An experimental study has been performed on fault detection and diagnosis method for a water chiller. Bayes classifier, which is one of classical pattern classifiers, is adopted in deciding whether fault occurred or not. FDD algorithm can detect refrigerant leak failure, when 20% amount of charged refrigerant for normal operation leaks from the water chiller. The refrigerant leak failure caused COP reduction by 6.7% compared with normal operation performance. When two kinds of faults, such as a decrease in the mass flow rate of cooling water and temperature sensor fault of cooling water inlet, are detected, COP is a little decreased by these faults.

  • PDF

ATWS Frequency Quantification Focusing on Digital I&C Failures

  • Kang Hyun Gook;Jang Seung-Cheol;Lim Ho-Gon
    • Nuclear Engineering and Technology
    • /
    • v.36 no.2
    • /
    • pp.184-195
    • /
    • 2004
  • The multi-tasking feature of digital I&C equipment could increase risk concentration because the I&C equipment affects the actuation of the safety functions in several ways. Anticipated Transient without Scram (ATWS) is a typical case of safety function failure in nuclear power plants. In a conventional analysis, mechanical failures are treated as the main contributors of the ATWS. This paper quantitatively presents the probability of the ATWS based on a fault tree analysis of a Korea Standard Nuclear Power Plant is also presented. An analysis of the digital equipment in the digital plant protection system. The results show that the digital system severely affects the ATWS frequency. We also present the results of a sensitivity study, which show the effects of the important factors, and discuss the dependency between human operator failure and digital equipment failure.

A Study on the Reliability Analysis Methodology of Passenger Door System of Electrical Type (전기식 출입문 시스템의 신뢰도 분석기법에 관한 연구)

  • Kim, Chul Sub;Lee, Hi Sung
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.10 no.1
    • /
    • pp.43-48
    • /
    • 2014
  • The door system for railway vehicles is the critical device directly influences on safety and satisfaction of passengers, Recently, electrical type of passenger door system is widely used for EMU type train instead of pneumatic type of passenger door system. The estimation of MTBF and failure rates for electrical type door system is essential. The manufacturor simply provides intrinsic reliability data for the railway operator. But actual reliability data based on operation and maintenance data is not complying with intrinsic reliability. In this study, operation and failure data associated with electrical door system were analyzed in order to determine actual MTBF and failure data. Intrinsic reliability data and service reliability data were studied to finallize much more practical and reliable actual reliability. Relax 2011 was used to predict intrinsic reliability and 217Plus model was also used to estimate of actual reliability data based on field data. Furthermore, it is necessary to keep studying on reliability prediction methodology and applying it in the field and doing research on improvement of reliability through feedback as well.

A study on the advanced method of aging manufacturing factory (노후화된 제조공장의 고도화 방법에 관한 연구)

  • Kim, Jeong-Min;Jang, Jong-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.69-71
    • /
    • 2018
  • Looking at Korea's manufacturing industry, there are many old manufacturing plants. In fact, the manufacturing process of the product inventory management and the unit price of the product are all created by using Excel, and the factory is operated by using it. Also, the operator can not predict the failure of the equipment in order to produce the product at work. Problems related to this may result in the loss of the documents during the instruction and work process between the manager and the worker, and the communication between the manager and the worker can not be properly performed, There is appear a situation in which the operation is continued by using the equipment without recognizing in the failure. In this paper, we propose a method for upgrading the aging manufacturing plant to improve the productivity and productivity of the product by predicting the efficient inventory management, unit price management, production volume, and the operator's failure prediction.

  • PDF

Reliability Improvement Method of the Electrical Door System for the Railway Vehicles (철도차량의 전기식 출입문 시스템의 신뢰도 개선 방안)

  • Yang, Yong Joon;Lee, Hi Sung
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.17-23
    • /
    • 2015
  • Electrical door system is one of the most essential items for the successful commercial operation of the railway vehicles. Nowadays, reliability values of electrical door system have a tendency to be included in technical requirements for design and manufacturing of rolling stocks. Manufacturer shall meet the reliability target values of electrical door system which is proposed by railway operator in procurement contract book. Railway operator shall approve the supplier's the reliability target values based on maintenance operation data. Railway operators are in the transition stage from the framework of maintenance interval based on time to the framework of maintenance interval based on distance. In this study, failure rates of the electrical door system currently used in railway vehicles are collected from maintenance field data. Failure rates are analyzed by using Minitab. Several kinds of plan for improving reliability are also suggested. It is necessary to keep studying on reliability prediction methodology, applying it in the field and implementing on improvement of reliability through feedback as well. Further, it will be useful for determining new maintenance policies or changing maintenance intervals for existing railway vehicles.

The Study on Intelligent Cooling Load Forecast of Ice-storage System (빙축열 시스템의 지능형 냉방부하예측에 관한 연구)

  • Koh, Taek-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.2061-2065
    • /
    • 2008
  • In the conventional operation of ice-storage system based on operator's experience and judgement, the failure in forecast of cooling load occurs frequently due to operator's misjudgement and unskilled operation. This study presents the method of constructing self-organizing fuzzy models which forecast tomorrow temperature, humidity and cooling load periodically for economic and efficient operation of ice-storage system. To check the effectiveness and feasibility of the suggested algorithm, the actual example for forecasting temperature, humidity and cooling load of ice- storage system in KEPCO training institute, Sokcho, is examined. The computer simulation results show that the accuracy of temperature, humidity, cooling load forecast of the suggested algorithm is higher than that of the conventional methods.

The On-Line Fault Detection and Diagnostic Testing of Systems using Neural Network (신경회로망을 이용한 시스템의 실시간 고장감지 및 진단 방법)

  • 정진구
    • Journal of the Korea Society of Computer and Information
    • /
    • v.3 no.2
    • /
    • pp.147-154
    • /
    • 1998
  • As technical systems in building are being developed, the processes and systems get more difficult for the average operator to understand. When operating a complex facility, it is beneficial in equipment management to provide the operator with tools which can help in dicision making for recovery from a failure of the system. The main object of the study is to develop real-time automatic fault detection and diagnosis system for optimal operation of IBS building.

  • PDF