• 제목/요약/키워드: Operative Temperature

검색결과 106건 처리시간 0.027초

Silar(Composite Resin계)의 변연누출(變緣漏出)에 관(關)한 실험적(實驗的) 연구(硏究) (MARGINAL LEAKAGE TEST ON "SILAR" COMPOSITE RESIN)

  • 권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제8권1호
    • /
    • pp.167-172
    • /
    • 1982
  • The purpose of this study was to evaluate the marginal sealing ability of "Silar". Using freshly extracted human teeth and 2% acquous methylene blue, the marginal leakage of dye in restorative materials such as Silar, Silar with acid etching technique, Hi-Pol, Hi-Pol Enamel Bond system, Adaptic and Amalgam were investigated at $37^{\circ}C$ and under temperature cycling in range of $4^{\circ}C-60^{\circ}C$. The results as follows; 1. All filling materials showed some degree of marginal penetration by 2% methylene blue dye. 2. Silar with acid etching technique revealed effective marginal sealing ability, but under temperature cycling it showed increased marginal leakage. 3. All composite resins showed greater marginal leakage than amalgam restoration. 4. Silar had the most effective marginal sealing ability in experimented composite resins.

  • PDF

The Indoor Environmental Quality Improving and Energy Saving Potential of Phase-Change Material Integrated Facades for High-Rise Office Buildings in Shanghai

  • Jin, Qian
    • 국제초고층학회논문집
    • /
    • 제6권2호
    • /
    • pp.197-205
    • /
    • 2017
  • The conflict between indoor environmental quality and energy consumption has become an unneglectable problem for highrise office buildings, where occupants' productivity is highly affected by their working environment. An effective Façade, therefore, should play the role of an active building skin by adapting to the ever-changing external environment and internal requirements. This paper explores the energy-saving and indoor environment-improving potential of a phase-change material (PCM) integrated Façade. Building performance simulations, combined with parametric study and sensitivity analysis, are adopted in this research. The result quantifies the potential of a PCM-integrated Façade with different configurations and PCM properties, taking as an example a south-oriented typical office room in Shanghai. It is found that a melting temperature of around $22^{\circ}C$ for the PCM layer is optimal. Compared to a conventional Façade, a PCM-integrated Façade effectively reduces total energy use, peak heating/cooling load, and operative temperature fluctuation during the periods of May-July and November-December.

열분해 소각시설에서의 일반폐기물의 연소특성 (Combustion Characteristics of Municipal Wastes in Pyrolysis Incinerator)

  • 박명호
    • 한국기계기술학회지
    • /
    • 제13권4호
    • /
    • pp.149-156
    • /
    • 2011
  • In case of domestic pyrolysis dry distillation gassification technology, it stays at the stage of its early introduction and development. Moreover, the companies possessed of this technology are limited to Japan and some countries in Europe, and domestic operative performance of this system is nominal, so there exist a lot of difficulties in securing its basic data. In addition, considering its operation and management, there happens a corrosion of metals by the production of corrosive gases in time of combustion of waste, and there arise a problem of occurrence of low temperature corrosion on exterior casing or gas ducts of a combustion chamber due to the high temperature corrosion around the burner of an incinerator, lowering the durability of an incinerator. Therefore, this study looked at the problems arising in time of incineration by understanding the characteristics of the pyrolysis dry distillation gassification incinerating facility, and did research on the improvement plan for durability of an incinerator for more economic, efficient waste incineration.

노인 전신마취 환자의 회복실 체류에 영향을 미치는 융합적 요인 (Convergent factors affecting length of stay in the postanesthesia care unit among elderly from general anesthesia patients)

  • 이수진
    • 사물인터넷융복합논문지
    • /
    • 제3권2호
    • /
    • pp.21-32
    • /
    • 2017
  • 본 연구는 노인 전신마취 환자의 회복실 체류시간에 영향을 미치는 융합적 요인들을 파악하기 위한 서술적 조사연구이다. 경기도 소재 C대학병원에서 2014년 1월 1일부터 2014년 12월 31일까지 전신마취하에 수술을 받고 회복실에 입실하였던 환자 중 65세 이상인 환자 300명을 대상으로 후향적으로 자료 수집을 하였다. 회복실 체류시간은 평균 48.4분으로 나타났으며, 회복실 체류시간 30-59분이 58.0%로 가장 많았다. 수술중 요인에 따른 회복실 체류시간 정도는 근이완제, 수혈, 동맥혈가스 검사, 체온 그리고 총 마취시간에 따라 유의한 차이가 있는 것으로 나타났다. 수술후 요인에 따른 회복실 체류시간 정도는 합병증, 자가 통증 조절기, 순환기계 약물사용에 따라 유의한 차이가 있는 것으로 나타났다. 회복실 체류시간에 영향을 미치는 요인을 알아보기 위해 다중 회귀분석을 실시한 결과 수술 후 '순환기계 약물사용', '수술 중 저체온'이 회복실 체류시간에 영향을 미치는 것으로 확인되었고 설명력은 13%로 나타났다. 이러한 결과를 토대로 회복실 체류시간 관련요인들을 모니터링하고 신속하게 처치하여 교정하는 것이 노인 전신마취 환자의 회복실 체류시간의 단축에 기여할 것으로 사려된다.

수종(數種) 표면처리제(表面處理劑)에 의(依)한 상아질(象牙質) 표면(表面)의 형태(形態) 변화(變化)에 관(關)한 연구(硏究) (MORPHOLOGICAL CHANGES OF DENTIN SURFACE TREATED WITH VARIOUS DENTIN SURFACE CONDITIONERS)

  • 조진호;최호영;민병순;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제13권2호
    • /
    • pp.323-334
    • /
    • 1988
  • The purpose of this study was to observe the effect of dentin surface conditioners on the dentin surfaces. Freshly extracted human molars were used in this study. They were stored at $4^{\circ}C$ saline solution before experiment. The crown portions of the teeth were cut in various directions by means of wet diamond point to expose dentin which include transverse, vertical oblique, horizontal and oblique cut to the long axis (Fig. 1). Each tooth was then mounted with self curing acrylic resin in brass ring to expose the flattened dentin surfaces. Final finish was accomplished by grinding the dentin specimens with wet No. 180 and No. 600 grit silicon carbide abrasive paper until a 6.0mm in diameter on a dentin surface was exposed without pulp exposure. The specimens were divided into 9 groups according to the modes of dentin treatment procedure. The following surface treatments were applied on these preparation surfaces; Group 1: unetched (control group) after finish with No. 600 silicon carbide abrasive paper. Group 2: etched with 30% phosphoric acid for 60s Group 3: etched with 10-3 solution for 60s Group 4: Cleaned with 5% NaOCl for 30s Group 5: applied Dentin Adhesit Group 6: cleaned with 5% NaOCl followed by applying the Dentin Adhesit$^{(R)}$ Group 7: applied Photo Bond on the unetched dentin followed by applying the Photo Clearfil Bright Group 8: Etched with 30% phosphoric acid followed by applying Photo Bond and Photo Clearfil Bright Group 9: etched with 10-3 solution followed by applying Photo Bond and Photo Clearfil Bright All the specimens were stored in $37^{\circ}C$ under 50% relative humidity for 24 hours before observations. The specimens in 7, 8, and 9 group, omitting the group 1 to 6, were demineralized in 10% HCl for 10s in order to observe the resin tags. All the specimens in each group were then dried at room temperature. The dried specimens were ion coated with Eiko ion coater (Eiko-engineering Co.), and observed in Hitachi S-430 Scanning electron microscope (Hitachi, Co. Tokyo) at 15KV. The following results were obtained as follows; 1. The smear layers were still remained in group 1,2,4,5, and 6. 2. There is no effect of 5% NaOCl and 30% phosphoric acid on the changes of dentin morphology 3. The dentin treated with 10-3 solution, indicating the tubules opened when the smear layer and the dental plug dissolved. 4. In case of applying the bonding agents the resin tag was not formed at the deep area of dentinal tubules, but in case of applying the Dentin Adhesit$^{(R)}$ that was not.

  • PDF

치질(齒質) 잔존량(殘存量)에 따른 색조변화(色調變化)에 관(關)한 연구(硏究) (A STUDY ON THE COLOR CHANGES ACCORDING TO THE AMOUNT OF REMAINING TOOTH MATERIAL)

  • 허성윤;민병순;최호영;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제12권1호
    • /
    • pp.131-147
    • /
    • 1986
  • The purpose of this study was to observe the color matching of lining or filling materials according to the remaining tooth material. Twenty-seven freshly extracted human central incisors were used in this experiments. The teeth were stored in saline solution at room temperature after extraction. All teeth were cut parallel to the tangent to height of contour on labial surface from the lingual surface until the pulp were completely removed. Then 27 teeth were devided into 0.5mm, 1.0mm and 1.5mm reduction groups according to the thickness of cutting the lingual surfaces of teeth. The specimens of control group were three teeth of 27 teeth with cutting the lingual surface same mode as above described. In the specimens of experimental groups, 8 kinds of lining and filling materials; FUJI IONOMER TYPE II (G-C Co. Japan), LINING CEMENT (G-C Co. Japan), Dycal (Caulk, U.S.A.), CLEARFIL F II (Kuraray Co. Japan), Crown Bridge & Inlay Cement (G-C Co. Japan), Copalite (Harry J. Bosworth Co. U.S.A.), HY-BOND (G-C Co. Japan) and LIV-CENERA (G-C Co. Japan); applied on the back of 24 teeth with 0.5mm, 1.0mm and 1.5mm cut thickness of lingual surfaces. Three teeth of control group did not applied linging or filling materials on the back of 3 kinds of different thickness of cutting the lingual surfaces. The absorbances of total 27 specimens were obtained by reflection spectrophotometer. (Cary 17 D, Varian Co, U.S.A.) The following conclusions were drawn from above the results; 1. The absorbance patterns in both experiment and control groups were gradually decreased with increasing wavelength of spectra. 2. The absorbance patterns were not decreased in relation to the kinds of lining or filling materials, but the amount of the remaining tooth materials. 3. In 0.5mm reduction group, FUJI IONOMER TYPE II, LINING CEMENT, LIV-CENERA and Copalite applied on the back of cut lingual surface showed similar absorbance patterns as control group. 4. The specimens which were reduced up to 1.0mm thickness and lined with FUJI IONOMER TYPE II and LINING CEMENT showed the comparable absorbance patterns to the control group. 5. In case of HY-BOND application after 1.5mm reduction were observed the similar absorbance pattern as compared with control group. 6. When Dycal, CLEARFIL and Crown Bridge & Inlay Cement were applied to cut teeth surfaces, there were much differences of absorbance between control groups and experimental groups.

  • PDF

Analysis and structural design of various turbine blades under variable conditions: A review

  • Saif, Mohd;Mullick, Parth;Imam, Ashhad
    • Advances in materials Research
    • /
    • 제8권1호
    • /
    • pp.11-24
    • /
    • 2019
  • This paper presents a review study for energy-efficient gas turbines (GTs) with cycles which contributes significantly towards sustainable usage. Nonetheless, these progressive engines, operative at turbine inlet temperatures as high as $1600^{\circ}C$, require the employment of highly creep resistant materials for use in hotter section components of gas turbines like combustion chamber and blades. However, the gas turbine obtain its driving power by utilizing the energy of treated gases and air which is at piercing temperature and pushing by expanding through the several rings of steady and vibratory blades. Since the turbine blades works at very high temperature and pressure, high stress concentration are observed on the blades. With the increasing demand of service, to provide adequate efficiency and power within the optimized level, turbine blades are to be made of those materials which can withstand high thermal and working load condition for longer cycle time. This paper depicts the recent developments in the field of implementing the best suited materials for the GTs, selection of proper Thermal Barrier Coating (TBC), fracture analysis and experiments on failed or used turbine blades and several other designing and operating factors which are effecting the blade life and efficiency. It is revealed that Nickel based Superalloys were promising, Cast Iron with Zirconium and Pt-Al coatings are used as best TBC material, material defects are the foremost and prominent reason for blade failure.

감마선에 조사된 중합체의 열자극 전류 (Thermally Stimulated Currents in Gamma Irradiated Polymer)

  • 추성실
    • Journal of Radiation Protection and Research
    • /
    • 제7권1호
    • /
    • pp.49-55
    • /
    • 1982
  • 유기중합체의 열자극전류는 방사선량측정기로서 사용가능한 특성을 갖고있으며 중합체의 구성성분이 생체조직과 등가성분이므로 의학 및 생물학분야에서 효과적인 방사선 측정기구로 이용할 수 있었다. 포리에틸렌등 중합체에 방사선을 조사한후 $10{\sim}100V$의 전압과 실온에서 $100^{\circ}C$까지의 온도에 따라 열자극 전류를 측정하고 분석함으로서 물질의 에너지상수($0.8{\sim}1.0eV$)와 방사선피폭량(수Krands)에 따른 열자극전류($10^{-2}{\sim}10^{-4}{\mu}A$)의 상호관계를 계측할 수 있었다.

  • PDF

수종복합레진의 경도측정에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON HARDNESS IN COMPOSITE RESINS)

  • 엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제4권1호
    • /
    • pp.35-38
    • /
    • 1978
  • The purpose of this study was to measure micro-knoop hardness and coefficient of thermal expansion on composite resins (Epolite, Adaptic, Hipol and Compo T.) Four different type of composite resins were measured at the varying depth of 30, 60, 90, 150, 200, 400, 700 and 1000 micron from the surface to deep portion. The specimens were stored both in the air room temperature for 2 days, 30 days and in water at $37^{\circ}C$ for 30 days. Thermal expansions of specimens(4mm in diameter and 50mm in height) were measured in quartz tube dilatometer from $20^{\circ}$ to $70^{\circ}C$ The following results were obtained. 1. The hardness of superficial portion were lower than inner portion of resin. 2. The value of hardness obtained from the specimen stored in room temperature in the water at $37^{\circ}C$ for 30 days were lower than above described Cases. 3. The coefficient of thermal expansion of Adaptic had $29.75{\times}10^{-6}/^{\circ}C$, Hipol had $30{\times}10^{-6}/^{\circ}C$, Epolite had $39.85{\times}10^{-6}/^{\circ}C$ and Compo T had $36.95{\times}10^{-6}/^{\circ}C$.

  • PDF

ECAP으로 제조된 초미세립 알루미늄 합금의 동적 변형거동에 미치는 어닐링 온도의 영향 (Effect of Annealing Temperature on Dynamic Deformation Behavior of Ultra-Fine-Grained Aluminum Alloys Fabricated by Equal Channel Angular Pressing)

  • 김양곤;고영건;신동혁;이종수;이성학
    • 대한금속재료학회지
    • /
    • 제46권9호
    • /
    • pp.563-571
    • /
    • 2008
  • The influence of annealing treatment on dynamic deformation behavior of ultra-fine grained aluminum alloys was investigated in this study. After equal-channel angular pressing at $200^{\circ}C$, most of the grains were considerably reduced to nearly equiaxed grains of $0.3{\mu}m$ in size. With an increment of various annealing treatments for 1 hour, resultant microstructures were found to be fairly stable at temperatures up to $200^{\circ}C$, suggesting that static recovery would be dominantly operative, whereas grain growth was pronounced above $250^{\circ}C$. The tensile test results showed that yield and ultimate tensile strengths decreased, but elongation-to-failure and strain hardening rate increased with increasing annealing temperature. The dynamic deformation behavior retrieved with a series of torsional tests was explored with respect to annealed microstructures. Such mechanical response was analyzed in relation to resultant microstructure and fracture mode.