• 제목/요약/키워드: Operation voltage

검색결과 3,665건 처리시간 0.028초

BESS의 경제성과 충방전 전압 특성을 고려한 적정 SOC 운영 영역 설정 기법에 관한 연구 (A Study on the Methodology of Determining Proper SOC Operation Range Considering the Economic Characteristics and the Charge and Discharge Voltage Characteristics of BESS)

  • 윤대식;추대혁;기병국;김준석;이병하;채우규
    • 전기학회논문지
    • /
    • 제64권4호
    • /
    • pp.529-536
    • /
    • 2015
  • With the growing interest of microgrid all over the world, many studies on microgrid operation are being carried out. The battery energy storage system(BESS) is a key equipment for effective operation of the microgrid. In this paper, we analyze the characteristics of the charge and discharge output voltage of the battery and the characteristics of the life-span variation and the investment cost when the state-of-charge (SOC) changes. The formulas to represent the quality of the charge and discharge output voltage of the battery and the economics due to the life-span variation and the investment cost according to DOD(Depth of Discharge) are derived. The methodology of determining the proper operation ranges of the battery SOC with varying the weighting of the quality of its charge and discharge output voltage of the battery and the economics due to its life-span variation and the investment cost is presented using these formulas.

Fast Detection Algorithm for Voltage Sags and Swells Based on Delta Square Operation for a Single-Phase Inverter System

  • Lee, Woo-Cheol;Sung, Kook-Nam;Lee, Taeck-Kie
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.157-166
    • /
    • 2016
  • In this paper, a new sag and peak voltage detector is proposed for a single-phase inverter using delta square operation. The conventional sag detector is from a single-phase digital phase-locked loop (DPLL) that is based on d-q transformations using an all-pass filter (APF). The d-q transformation is typically used in the three-phase coordinate system. The APF generates a virtual q-axis voltage component with a 90° phase delay, but this virtual phase cannot reflect a sudden change in the grid voltage at the instant the voltage sag occurs. As a result, the peak value is drastically distorted, and it settles down slowly. A modified APF generates the virtual q-axis voltage component from the difference between the current and the previous values of the d-axis voltage component in the stationary reference frame. However, the modified APF cannot detect the voltage sag and peak value when the sag occurs around the zero crossing points such as 0° and 180°, because the difference voltage is not sufficient to detect the voltage sag. The proposed algorithm detects the sag voltage through all regions including the zero crossing voltage. Moreover, the exact voltage drop can be acquired by calculating the q-axis component that is proportional to the d-axis component. To verify the feasibility of the proposed system, the conventional and proposed methods are compared using simulations and experimental results.

제한된 환경에서의 해수냉각펌프용 유도전동기 최대출력 운전을 위한 약계자 제어 (Advanced Field Weakening Control for Maximum Output Power Operation of Seawater Cooling Pump Induction Motor in a Limited Environment)

  • 손영득;서용주;정준형;김장목
    • 전력전자학회논문지
    • /
    • 제18권6호
    • /
    • pp.540-546
    • /
    • 2013
  • The induction motor is used for driving the special equipments such as warship and submarine pump due to robust structure and simple maintenance. Domestic and foreign warships use a wide range of voltages and the DC voltage sources mainly from battery. In the low voltage level, the ${\Delta}$-connection operation of induction motor can be used for the maximum power. However, the temperature of the inverter increases because of the high input current. On the other hand, Y-connection operation of the induction motor does not cause a problem of temperature because of the low input current compared to the ${\Delta}$-connection. But the lack of the supply voltage can not be avoided. Therefore, this paper suggests the algorithm of the optimum field weakening control to extend the operating range of the induction motor with maximum power in a limited thermal and DC voltage condition.

Advanced Field Weakening Control for Maximum Output Power Operation of Induction Motor in a Limited Environment

  • Seo, Yong-Joo;Go, Hee-Young;Kim, Jang-Mok
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 추계학술대회 논문집
    • /
    • pp.217-218
    • /
    • 2012
  • A load motor used for warship or submarine is with limited volume and weight, also specific environmental tests like impact, vibration, noise, temperature and EMC/EMI have to be satisfied. Induction motors, synchronous motors, BLDC motor and etc, are used depending on the purpose of using military equipment. Induction Motors are used for a number of military equipment more commonly due to the robust structure and simple maintenance. Domestic and foreign warships have a wide range of voltages as the DC voltage sources with battery are mainly used for them. The ${\Delta}-connection$ operation of the induction motor is required to make the maximum power in a low voltage level. But the elements' temperature of the inverter increases due to high input current when it is in the ${\Delta}-connection$ operation. Therefore, the induction motor must be driven with the Y-connection. The lack of voltage needs to be with the field weakening control. This paper suggests the optimum field weakening control algorithm to drive the induction motor with maximum power in a limited thermal and DC voltage condition.

  • PDF

A Study on Variable Speed Generation System with Energy Saving Function

  • Dugarjav, Bayasgalan;Lee, Sang-Ho;Han, Dong-Hwa;Lee, Young-Jin;Choe, Gyu-Ha
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.137-143
    • /
    • 2013
  • This paper presents development of variable speed generation (VSG) system with energy saving function. The rubber tyred gantry crane (RTGC) requires the power from diesel-engine. Significant fuel savings by reducing the engine speed can be achieved, because all of operation modes except hoisting are required lower power than rated value of engine. When low speed operation output voltage of generator is decrease until acceptable range of motor driver inverters and auxiliary load supplier. According to power demand engine speed is varying from 20 to 60Hz, and voltage is varying between 210Vac and 480Vac. When idle mode or low power operation dc/dc converter operates by constant output voltage control and inverters dc site voltage is compensated by it. This paper proposed 3-phase interleaved boost converter which has the same structure as the commercially available 3-phase inverter and current sharing capability. 400kW interleaved converter is designed and a performance of converter is evaluated through several experiments with a RTGC system. Energy saving VSG system can cut down fuel consumption by 36% and 21.3% at idle and unidirectional load operations.

Integrated High-Voltage Generators for Low-Power Bistable LCD Drivers

  • Doutreloigne, Jan;Hendrix, Wim
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.135-138
    • /
    • 2004
  • This paper describes the architecture, the basic operation principle and detailed experimental results of digitally programmable high-voltage generators that can be used in monolithic low-power high-voltage bistable LCD drivers. Two different design approaches, depending on whether the application allows the use of external passive components or not, are analyzed.

  • PDF

연속적인 운전모드의 전환을 위한 계통연계형 인버터의 간접 전류 제어기법 (Indirect Current Control of Utility Interactive Inverter for Seamless Transfer)

  • 유태식;배영상;김효성;최세완
    • 전력전자학회논문지
    • /
    • 제11권1호
    • /
    • pp.72-78
    • /
    • 2006
  • 분산발전시스템에 비상부하 등의 전용부하가 접속되어 있는 경우, 주전원에 고장이 발생하러라도 비상전용부하에는 지속적인 전력을 공급하기 위하여 의도적인 단독운전을 하게 된다. 기존의 계통연계형 인버터는 주전원에 전력을 주입하기 위하여 평소에 전류제어모드로 운전을 하기 때문에, 의도적인 단독운전 상황이 발생하는 경우 비상부하에 안정된 전압을 공급해 주기 위하여 전압제어모드로 운전을 전환하여야한다. 이러한 운전모드의 전환시 인버터의 출력단 전압에 심각한 과도문제가 발생된다. 본 논문에서는 의도적인 단독운전 발생시 인버터 운전모드 전환에 따른 출력전압의 과도현상을 최소화하기 위한 인버터 토폴로지와 제어알고리즘을 제안한다. 제안된 간접전류제어 알고리즘에 적합한 LCL필터 설계방법과 설계데이터를 제시한다.

대전력 3상 유도전동기의 고정자권선을 이용한 전압원 인버터의 병렬운전 (Parallel Operation of Voltage Source Inverters by Using Stator Windings of High Power Three-Phase Induction Motors)

  • 김인동;노의철;전성즙
    • 한국정보통신학회논문지
    • /
    • 제8권4호
    • /
    • pp.815-820
    • /
    • 2004
  • 본 논문에서는 고압 대전력 3상 유도전동기의 고정자 권선을 이용한 전압원 인버터의 병렬운전 방식을 제안한다. 현재 사용되고 있는 대부분의 4극 이상 대전력 유도전동기는 각 상의 권선이 외부에서 접근이 가능하도록 외부단자가 설치되어 있으며, 이들 외부 단자를 이용하여 복수대의 전압원 인버터를 병렬운전 하여 대전력 유도전동기를 구동할 수 있다. 이와 같이 고압 대전력 유도전동기를 복수 개의 전압원 인버터를 병렬 운전하여 구동할 경우, 특정 인버터의 고장발생 시 비록 구동 토오크는 감소될지라도, 나머지 인버터로 시스템을 계속 구동할 수 있어 시스템의 고장대처능력을 향상시킬 수 있다. 또한 병렬 운전되고 있는 각 인버터의 스위칭 동작에 대해 서로 위상차를 갖게 함으로서, 등가 스위칭 주파수를 증가시켜 출력 토오크 리플 감소와 입력 전류 리플 감소, DC Link 커패시터의 크기 감소와 같은 좋은 특성을 얻을 수 있다. 또한 각 인버터로의 전력의 분산에 의해 시스템에서 발생하는 EMI영향을 감소시킬 수 있다. 본 논문에서는 제안한 방식을 컴퓨터 시뮬레이션을 통해 특성을 증명하였다.

단상 SRM 구동을 위한 Passive Converter 동작특성 (Driving Characteristic of Passive Converter for Single Phase SRM)

  • ;석승훈;이동희;안진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.113-115
    • /
    • 2008
  • At the high speed operation, the high demagnetization voltage can reduce the negative torque, so the output power and efficiency can be improved. In this paper, a novel power converter for single phase SRM with high demagnetization voltage is proposed. A simple passive capacitor circuit is added in the front-end, which consists of three diodes and one capacitor. Based on this passive network, the two capacitors can be connected in series and parallel, so the phase winding of SRM obtains general do-link voltage in excitation mode and the double dc-link voltage in demagnetization mode. The operation modes of the proposed converter are analyzed in detail. Some computer simulation results is done to verify the performance of proposed converter.

  • PDF

전력용 백업퓨우즈 차단특성 모델링 (Empirical Modeling on the Breaking Characteristics of Power Current Limited Fuse)

  • 이세현;이병성;한상옥
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권9호
    • /
    • pp.391-396
    • /
    • 2005
  • In this paper the modeling of interrupting characteristics of a high voltage current limiting fuse to be used in a power distribution system is introduced. In order to reduce the level of energy which can be absorbed by equipment during fault current flow, a high voltage current limiting fuse can generate a high voltage at the fuse terminals. Consequently it is necessary to model and analyze precisely the voltage and current variation during a CL fuse action. The characteristics of CL fuse operation modeled by electrical components have been performed with less than 6 [$\%$] errors. So the fuse designer or manufacturer can estimate the characteristics of CL fuse operation by using this modeling. The Electro Magnetic Transient Program (EMTP) is used to develop the modeling.