• 제목/요약/키워드: Operation stability

검색결과 1,719건 처리시간 0.034초

에너지 마진을 이용한 과도안정도 제약 급전 알고리즘 (A Dispatch Algorithm with Transient Stability Constraints by using Energy Margin)

  • 정연재;장동환;전영환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권1호
    • /
    • pp.1-6
    • /
    • 2006
  • The emergence of competitive power market makes dispatch algorithm with transient stability constraints increasingly important for the transparent power system operation. Heuristic and off-line evaluation for the operation point can produce a discrimination among market players in the deregulated power system. In this paper, a dispatch algorithm with transient stability constraints is proposed. Energy margin under the TEF(Transient Energy Function) structure is adopted as a measure for the stability index. Implementation issues and simulation results are discussed in the context of a 10-bus system

Research and Stability Analysis of Active-Disturbance-Rejection-Control-Based Microgrid Controllers

  • Xu, Xiaoning;Zhou, Xuesong;Ma, Youjie;Liu, Yiqi
    • Journal of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.1611-1624
    • /
    • 2017
  • With the rapid development of microgrid technology, microgrid projects are no longer limited to laboratory demonstrations and pilot platforms. It shows greater value in practical applications. Hence, the smooth interaction between a microgrid and the main grid plays a critical role. In this paper, a control method based on active disturbance rejection control (ADRC) is proposed in order to realize seamless transitions between grid-connected and islanding operation modes and stable operation with variable loads. It is verified by simulations that the proposed ADRC-based method features better performance when compared to conventional proportional-integral-differential (PID) control. Meanwhile, the stability of the third-order extended state observer (ESO) in second-order ADRC is validated by using Lyapunov stability criteria.

Stability Tests on Anion Exchange Membrane Water Electrolyzer under On-Off Cycling with Continuous Solution Feeding

  • Niaz, Atif Khan;Lim, Hyung-Tae
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권3호
    • /
    • pp.369-376
    • /
    • 2022
  • In this study, the stability of an anion exchange membrane water electrolyzer (AEMWE) cell was evaluated in an on-off cycling operation with respect to an applied electric bias, i.e., a current density of 500 mA cm-2, and an open circuit. The ohmic and polarization resistances of the system were monitored during operation (~800 h) using electrochemical impedance spectra. Specific consideration was given to the ohmic resistance of the cell, especially that of the membrane under on-off cycling conditions, by consistently feeding the cell with KOH solution. Owing to an excess feed solution, a momentary increase in the polarization resistance was observed immediately after the open-circuit. The excess feed solution was mostly recovered by subjecting the cell to the applied electric bias. Stability tests on the AEMWE cell under on-off cycling with continuous feeding even under an open circuit can guarantee long-term stability by avoiding an irreversible increase in ohmic and polarization resistances.

틸팅차량 주행에 따른 기존선 궤도의 주행안정성 평가 (Stability Evaluation of Track on Conventional Line According to Traveling Tilting Train)

  • 박용걸;엄기영;최정열;성덕룡
    • 한국철도학회논문집
    • /
    • 제10권6호
    • /
    • pp.701-708
    • /
    • 2007
  • 기존선 속도향상을 위해 개발된 틸팅열차는 기존열차에 비하여 승차감의 저하 없이 곡선부를 더욱 빠르게 주행할 수 있기 때문에 전체 운행시간을 단축시킬 수 있는 장점이 있다. 그러나 일반적으로 주행열차에 의해 궤도에 발생하는 힘은 주행속도의 함수로 표현되므로 주행속도가 증가하는 만큼 궤도가 부담해야할 힘의 크기도 증가하게 된다. 따라서 본 연구에서는 틸팅차량의 기존선 곡선부 주행 시 내 외측 레일의 탈선계수를 산정하여, 곡선반경 증속 여부, 선로개량 유 무에 따른 주행안정성을 평가하였으며, 기존에 운행중인 일반열차와 고속열차의 주행안정성을 비교, 분석하였다. 연구결과, 측정대상 구간에서 측정된 동적 윤중을 이용하여 산출한 동적 윤중 감소량은 차체진동을 고려한 차량 전복에 대한 동적윤중 감소한계치를 모두 만족하는 것으로 나타나 향후 틸팅차량 투입시 대상구간에서의 윤중 감소에 따른 열차탈선의 위험은 없을 것으로 판단된다.

An Advanced Embedded SRAM Cell with Expanded Read/Write Stability and Leakage Reduction

  • Chung, Yeon-Bae
    • 전기전자학회논문지
    • /
    • 제16권3호
    • /
    • pp.265-273
    • /
    • 2012
  • Data stability and leakage power dissipation have become a critical issue in scaled SRAM design. In this paper, an advanced 8T SRAM cell improving the read and write stability of data storage elements as well as reducing the leakage current in the idle mode is presented. During the read operation, the bit-cell keeps the noise-vulnerable data 'low' node voltage close to the ground level, and thus producing near-ideal voltage transfer characteristics essential for robust read functionality. In the write operation, a negative bias on the cell facilitates to change the contents of the bit. Unlike the conventional 6T cell, there is no conflicting read and write requirement on sizing the transistors. In the standby mode, the built-in stacked device in the 8T cell reduces the leakage current significantly. The 8T SRAM cell implemented in a 130 nm CMOS technology demonstrates almost 100 % higher read stability while bearing 20 % better write-ability at 1.2 V typical condition, and a reduction by 45 % in leakage power consumption compared to the standard 6T cell. The stability enhancement and leakage power reduction provided with the proposed bit-cell are confirmed under process, voltage and temperature variations.

Driving technologies for AMOLEDs

  • Matsueda, Yojiro;Kim, Hong-Kwon;Chung, Ho-Kyoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.393-398
    • /
    • 2006
  • This paper classifies driving technologies for AMOLEDs by the driving TFT conditions in pixels. A saturation region operation type driving TFT circuit provides good stability of OLED because of constant current drive. However, complicated compensation circuits are necessary to avoid effect of the TFT characteristics deviation. On the other hand, a linear region operation type driving TFT circuit provides better uniformity of the display image and lower power consumption. However, the stability of OLED is critical because of constant voltage drive.

  • PDF

적정 공급신뢰도 확보를 위한 안정화장치 구성 및 설치운영 (Design, Implementation of the Bulk Power Stabilizing System to ensure the appropriate Power System Reliability)

  • 김창무;이효상;이승언;김석일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1510-1513
    • /
    • 1999
  • Carried out simulation for yearly peak and March load time of the KEPCO Power System in 1999. Analysis of the problems in power system operation by powerflow, fault and stability study. Establishment of power system optimal operating plan by installation of power system stabilizer.

  • PDF

2로 온도계수 궤환로에서의 안정성 해석 (Stability analysis in a two-path Temperature coefficient feedback reactor)

  • 노윤래
    • 전기의세계
    • /
    • 제16권2호
    • /
    • pp.17-21
    • /
    • 1967
  • In reactor operation, it is widely known that the absolute stability may not exist for multiple feedback paths even though the single lumped negative temperature coefficient feedback case is clearly stable at all frequencies above those creating xenon poisoning effects. However, interesting and useful stability information may be obtained from a two-path temperature coefficient feedback which can be represented in a water-cooled, water-moderated hetergeneous reactor. In this paper, the outline of an operating stability of a reactor having two-path temperature coefficient feedback is analyzed and described neglecting poison effects.

  • PDF

장대교량 신축부에서 침목간격 확대가 차량의 주행안전성 및 궤도의 구조안정성에 미치는 영향 (Effects of Expansion of Sleeper Span at the Deck End of a Long Continuous Bridge on Train Safety and Track Stability)

  • 양신추
    • 한국소음진동공학회논문집
    • /
    • 제25권9호
    • /
    • pp.620-627
    • /
    • 2015
  • Long continuous bridge deck can become contracted considerably as temperature drops, which can lead to a large expansion of sleeper span at the end of it. Since this huge sleeper span then can cause problems both with safety of train operation and structural stability of tracks, it is necessary to take the issue into consideration systematically in the designing process of the bridge. In this paper, an evaluation process through the analysis of train-track interaction was presented which can basically review the effects of the expansion of sleeper span at the end of long continuous bridge deck on the safety of the train and the structural stability of the track. The analyses of the interaction between the light rail train and tracks were carried out targeting the sleeper span as a main parameter. The safety of train operation and structural stability of tracks in a light rail system due to the expansion of the sleeper span were evaluated by comparing the numerical results with the related criteria.

연료전지용 탄화수소 전해질 막의 산화안정성 향상을 위한 유기물 복합막의 제조 및 특성 분석 (Hydrocarbon-Organic Composite Membranes for Improved Oxidative Stability for PEMFC Applications)

  • 박샛별;이혜진;배병찬
    • 전기화학회지
    • /
    • 제19권2호
    • /
    • pp.45-49
    • /
    • 2016
  • 양이온 교환막 연료전지 운전 중에 발생하는 하이드록시 라디칼에 의한 전해질 막의 산화분해를 효과적으로 방지하기 위해 유기물 라디칼냐��쳐를 도입하였다. 술폰화 폴리아릴렌에테르술폰 고분자를 이용하여 폴리페놀 화합물의 일종인 루틴을 도입하여 복합막을 제조하였고, 제조된 고분자 전해질 복합막은 함수율 및 이온전도도의 측정을 통하여 루틴이 전해질 막의 물리화학적 성질에 미치는 영향에 대해서 조사하였다. 실제 연료전지 운전과 유사한 조건을 구현할 수 있는 과산화수소 폭로 가속화 평가장치를 이용하여 전해질 복합막의 산화안정성을 평가하였다. 루틴을 함유한 고분자 전해질 복합막은 이온전도도가 유지되면서 산화안정성이 향상된 결과를 보여주었다.