• Title/Summary/Keyword: Operation environment test bed

Search Result 25, Processing Time 0.022 seconds

A Study on the Factors Affecting the Low Back Pain of Workers in Hospital (병원 근무자의 요통 발생 요인에 관한 연구)

  • Jeong, Jin-Young;Son, Kyung-Hyun
    • Journal of Korean Physical Therapy Science
    • /
    • v.16 no.3
    • /
    • pp.55-66
    • /
    • 2009
  • Background: The purpose of this research was to investigate the factors affecting the low back pain of workers in hospital. 214 subjects waking at two general hospitals in Yosu city participated in this survey. Subjects consisted of doctors, nurses, medical engineers, officers and general laborers. The survey data were collected by a written questionnaire which made out by themselves for 25 days, from fourth August to 29th August, 2008. Methods: The questionnaire consisted of four categories, general, occupational, working habitual and the daily living characteristics. The collected data were analyzed by Chi-square test based on the present or absent of low back pain. Results: 1. In the general characteristics, low back pain had no significant relationship to all factors, sex, ago, body mass index, weight and height. 2. In the occupational characteristics, the phase of distribution of low back pain had statistical significant differences in the working hours a week, satisfaction of pay, satisfaction of occupation(p<0.05). However low back pain did not significantly related to the kind of occupation, period of work and degree of stress. 3. In the habitual characteristics, low back pain was significantly influenced by working posture, frequency of using lumbar and heavy material lifting, monotonous repetition of working operation and noise(p<0.05). No significant difference was shown in the factor of convenience of chair. 4. In the daily living characteristics, low back pain shown the significant differences in walking time a day, status of health and smoking pattern(p<0.05). there were, however, no significant differences in the aspect of the kind of house and bed, sleeping attitude, driving, riding time on the vehicle, exercising, frequency of cultural life and drinking alcohol. Conclusion: when I see above resultants totally, it appears a higher incidence caused by working environment rather than living habit and then consequently compared to hospital workers, they also have high incidence like others. In order to reduce incidence of low back pain and enjoy the our life we need to educate ourselves preventing program for low back pain and try to effort for preventing of low back pain on each department and individual.

  • PDF

A case study for installing of Energy Metering Systems in an Office Building (사무소 건물의 에너지 미터링 시스템 구축에 관한 사례연구)

  • Han, Hye-Sim;Lee, Na-Eun;Lee, Jin-Sook;Jeong, Hak-Geun;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.51-57
    • /
    • 2013
  • Energy saving starts by knowing how much energy is being consumed. A building factor is easier than any other things in energy saving. Since, especially, it is closely connected with user's space-use-patterns and manager's utility-operation-style. An energy metering system lets building users know about energy consumption pattern in buildings and measure energy in real time. Development and materialization of metering systems need more careful plans, so that they depend on a demand of individual facilities and available infrastructures they used to use. But, so far, there is no guidelines how to install metering systems. This paper suggested how to install meters and researched a method for how to analyze by using metered data. For that, Green Building in KIER is used as a test bed. As the results, nevertheless the smallest number of meters is basically one for the whole building energy measuring, it is too limited in analysis. So we needed to add the sort of fuel and utility types and found that it depends on all cases. For this reasons, a guideline should be created in order to install meters as soon as possible. It would be suggest a way to save more energy in building factor.

A Study on Routing Implementation and Performance Measurement Scheme among IPv6 Terminals (IPv6 단말간 라우팅 구현과 성능측정 구성 방안에 관한 연구)

  • Woo, Jung-Yoon;Yang, JaeSoo;Lee, Jong Won;Kim, Kangju
    • Journal of Digital Contents Society
    • /
    • v.19 no.3
    • /
    • pp.505-512
    • /
    • 2018
  • Internet demand has increased rapidly, and Internet Protocol Version 4, the main Internet protocol, can not cope with various types of network demand in the future. Therefore, it is urgent to spread IPv6-based stable network to solve the shortage of Internet address resources. Due to the proliferation of IoT and the increase in mobile devices, efficient and optimal IPv6 routing design is indispensable. In this paper, we have studied about characteristics of IPv6, address system of IPv6, structure analysis and efficient routing technology among IPv6 terminals. Furthermore, experimental results on routing packet analysis and convergence time are presented in network - based IPv6 routing implementation environment. In addition, we show the results of the experiment analysis by dividing the implementation of IPv6 routing, operation test, and fail over performance into three kinds of routing protocol methods. As a result, this study can be applied to the introduction of IPv6 system, test bed environment construction, and network design.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

An Analytical Study on Rational use of Undersea Space (해저공간의 합리적 활용을 위한 분석적 연구)

  • Won-Jo Jung;Nam-Ki Park
    • Journal of Navigation and Port Research
    • /
    • v.47 no.3
    • /
    • pp.147-154
    • /
    • 2023
  • This study aims to determine the necessity, role, utilization, and operation and management plan in relation to the underwater space platform where humans can newly reside. It provides a comprehensive opinion on the need for creating undersea space and operation plans based on opinions of industry-university-affiliated organizations involved in the R&D project of the Ministry of Maritime Affairs and Fisheries for the utilization of undersea space and external experts participating in marine technology development. In this study, a survey was conducted on researchers participating in the construction of a Korean submarine space platform. FGI was conducted on marine technology development experts. Results were then derived. As a result of the analysis, the need for subsea space construction was found to be high. As for the role of subsea space, the most common opinion was to develop technology for utilizing subsea space and to secure marine science research functions. It was found that the creation of subsea space would have a positive impact on the domestic industry, especially the deep-sea development industry and the shipbuilding/offshore structure industry. In terms of utilization, after the end of the seabed space test bed, the response to utilization as a marine observation base and marine ecosystem research had the highest proportion. As for expected inconvenience, discomfort in the psychological environment was the highest. Experts suggest that securing a continuous budget is most important for stable operation in the future and that securing a manpower budget is essential for itemized budgets. In addition, it was judged that it would be appropriate to establish a prior agreement from the time of the prior agreement and prepare a countermeasure before proceeding with the project in order to ensure ownership issues, consignment management issues, and cost issues when using the project after the end of the project.