• Title/Summary/Keyword: Operation characteristics

Search Result 7,606, Processing Time 0.037 seconds

An Analysis of Recloser Operation According to Recovery Characteristics of Superconducting Fault Current Limiter (초전도 한류기의 회복특성에 따른 재폐로 동작 분석)

  • Rhee, Sang-Bong;Kim, Chul-Hwan;Kim, Kyu-Ho;Kim, Jae-Chul;Hyun, Ok-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.905-910
    • /
    • 2009
  • For proper application and operation of a SFCL(Superconducting Fault Current Limiter) in distribution systems, the prior investigation of fundamental characteristics and its effects analysis to the systems are very important. A point of view in coordination with recloser in distribution systems, characteristic about quenching and recovering of SFCL should be studied. Especially, its detailed study of recovery characteristic is particularly important to avoid conflict between the SFCL and the recloser. In this paper, the resistive type SFCL and recloser, which used in distribution system, were implemented using EMTP/ATPDraw and MODELS language. To analyze the recovery characteristics of SFCL according to recloser operation in distribution systems, case studies have been simulated and investigated.

Analysis of Reactive Power Characteristic for Wind Farms in Jeju System (제주계통 풍력발전단지의 무효전력 특성 분석)

  • Choy, Young-Do;Park, Young-Shin;Jeon, Dong-Hoon;Yoon, Gi-Gab;Park, Sang-Ho
    • New & Renewable Energy
    • /
    • v.6 no.2
    • /
    • pp.19-26
    • /
    • 2010
  • Experiences in wind farm operation are very limited in Korea, and the foundation for setting standards in power system connection is weak. Therefore, connection and operation standards for wind farms in other countries must be reviewed and power system operation criteria need to be established in order to set up connection standards and optimal operation plans according to the Jeju power system. In this study, reactive power control characteristics of a wind farm were analyzed using a wind farm model of the Jeju power system to propose power system connection operation standards for wind generation within the Jeju power system. Also, change in characteristics of the power system for the application of each reactive power control standard was confirmed, and the results were verified through trial tests arm was analyzed.

Development of Linking Methodology of Direct Load Control and System Economic Operation (직접부하제어와 계통경제운용의 연계기법 개발)

  • Lee, Buhm
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.594-597
    • /
    • 2003
  • To link direct load control and economic operation considering system spinning reserve characteristics, this paper presents a new metholodogy. By formulating new constraints, considering system spinning reserve characteristics is possible. And by employing 3-D dynamic programming, linking direct load control and economic operation is possible. As a result, economical DLC and operation schedule of the power system is possible. The usefulness of the method is verified by applying to the test system.

  • PDF

Analysis of Output Characteristics for the Resonant DC Link Inverter Using PWM Inverter Modulation Methods (인버터 PWM 방식을 이용한 공진형 직류 링크 인버터의 출력 특성 해석)

  • 김윤호;윤병도;이병순
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.6
    • /
    • pp.615-624
    • /
    • 1992
  • For the operation of the resonant DC link inverters, only limited number of modulation techniques such as the delta modulation and instantaneous current control techniques have been suggested. However, these modulation techniques have some limitations in practical operation. In this paper, the application of conventional inverter modulation techniques is suggested for the control of the resonant DC link inverter. The harmonic analysis results are presented. The results show that these modulation techniques offer good output characteristics similar to conventional inverter PWM techniques for the operation of the resonant DC link inverter. This implies that not only the delta modulation technique and instantaneous current control techniques but also various other modulation techniques can be applied to the operation of the resonant DC link inverter. This also indicates that open loop control as well as closed loop control can be used for the operation of the resonant inverter. The resonant DC link inverter with various modulation strategies is implemented using V-40 microprocessors.

  • PDF

A Study on the Characteristics of Vibration Induced by Subway Operation (지하철 운행에 따른 진동특성에 관한 연구)

  • 배동명;신창혁;최철은;박상곤;백용진
    • Journal of KSNVE
    • /
    • v.11 no.2
    • /
    • pp.249-256
    • /
    • 2001
  • In this paper the characteristics of vibration induced by subway trains running on track is discussed. The quantitative prediction of the vibration level and the countermeasure for reduction of necessary, is of importance for the better environment. It was made the constructed Bundang line as first step with the modified Young-Dan type to basis on the Japanese Young-Dan type. In this paper it was measured and analyzed to two region ($ \circled1$Susuh-Bokjung. $ \circled2$Chorim-Suhyun region) of this. at present, operational Bundang line when averaging velocity of train is 60 (km/h). As the response characteristics of frequency Induced by subway operation, it was confirmed that frequency band of neighborhood of 30~80 Hz in generally dominant. Also to assess the quantitative nitration as response level to be measured for each point of two region in subway operation, the vibrational response level was measured at the state to be not subway operation. And the level was approximately $\fraction one-fifth~\fraction one-ten$ level comparing to subway operation.

  • PDF

The Analysis of Characteristics of Flux-Lock Type SFCL with Adjustable Inductance Level in Current Limiting Operation (인덕턴스 조정에 따른 자속구속형의 전류제한특성분석)

  • Lee, Na-Young;Choi, Hyo-Sang;Park, Hyoung-Min;Cho, Yong-Sun;Nam, Gueng-Hyun;Lim, Sung-Hun;Park, Chung-Ryul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.157-158
    • /
    • 2005
  • Superconducting fault currents(SFCLs) are expected to improve not only reliability but also stability of real power systems. The analysis on the single line-to-ground fault of the integrated three phase flux-lock type SFCL, which consists of three flux-lock reactor wound on an iron core in each single phase and three YBCO thin films, was investigated in current limiting operation characteristics. We compared 21turn numbers with 42turn numbers according to wound turn numbers each the coil 2 under the additive polarity winding operation between coil 1 and coil 2. The three phase flux-lock type SFCL using an iron core differently operates general three phase resistive SFCLs. When a single line-to-ground fault occurred, the SFCL's three units were quenched after fault onset. We confirmed effective current limiting operation characteristics with adjustable inductance level.

  • PDF

Prediction of practically chargeable cold energy in an ice storage system (빙축열시스템의 실질적인 최대 축열 가능량 예측)

  • Lee, D.-Y.;Kang, B.H.;Kim, M.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.133-146
    • /
    • 1999
  • The charge operation of an ice storage system has been analyzed in this paper. The thermal characteristics of major components of the ice storage system. i.e., the refrigerator and the ice storage tank are evaluated from performance tests on an existing ice storage system. Based on the measured data for thermal characteristics, a simulation is carried out for the charge operation and the effect of the refrigerator size on the system performance is investigated. The results indicate that the larger the refrigerator size for a given storage capacity, the lower the inlet temperature of the ice storage tank so that the lower the efficiency of charge operation. It is also found that there exists an optimal size of the refrigerator with which the ice storage at the end of the charge operation is maximized, but the complete charge is not possible even with the optimally sized refrigerator. This leads to the result that the design capacity of the storage tank should be larger than the required amount of cold energy for the daytime cooling considering the practically chargeable amount of cold energy during the nighttime. Where the cooling load sharing of the storage is 40%, the nominal capacity of an ice storage tank needs to be larger than the required storage amount by 30%.

  • PDF

A Study on Optimal Operation of Microgrid Considering the Probabilistic Characteristics of Renewable Energy Generation and Emissions Trading Scheme (신재생에너지발전의 확률적인 특성과 탄소배출권을 고려한 마이크로그리드 최적 운용)

  • Kim, Ji-Hoon;Lee, Byung Ha
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.1
    • /
    • pp.18-26
    • /
    • 2014
  • A microgrid can play a significant role for enlargement of renewable energy sources and emission reduction because it is a network of small, distributed electrical power generators operated as a collective unit. In this paper, an application of optimization method to economical operation of a microgrid is studied. The microgrid to be studied here is composed of distributed generation system(DGS), battery systems and loads. The distributed generation systems include combined heat and power(CHP) and small generators such as diesel generators and the renewable energy generators such as photovoltaic(PV) systems, wind power systems. Both of thermal loads and electrical loads are included here as loads. Also the emissions trading scheme to be applied in near future, the cost of unit start-up and the operational characteristics of battery systems are considered as well as the probabilistic characteristics of the renewable energy generation and load. A mathematical equation for optimal operation of this system is modeled based on the mixed integer programming. It is shown that this optimization methodology can be effectively used for economical operation of a microgrid by the case studies.

Clinical Characteristics of Small Bowel Perforation due to Blunt Abdominal Trauma (복부 둔상으로 인한 소장 천공의 임상 양상에 대한 고찰)

  • Bae, Jung-Min
    • Journal of Trauma and Injury
    • /
    • v.24 no.2
    • /
    • pp.125-128
    • /
    • 2011
  • Purpose: Blunt small bowel injury (SBI) is frequently combined other organ injury. So, clinical outcome and characteristics of SBI are influenced by other combined injuries. Thus, we analyzed isolated SBI patients and studied clinical outcome and characteristics. Methods: Between 2005 and 2010, 36 consecutive patients undergoing laparotomy due to isolated SBI were identified in a retrospectively collected. Database. Clinical outcome and characteristics were analyzed. Results: Laparotomy was performed in 36 patients. Primary repair was performed 17 patients. Segmental resection of small bowel was performed 19 patients. Median time gap from trauma to operation was 9 hours. In 24 hours from trauma, operation was performed 31 patients. Post operative death was 5 patients. Mean hospital stay was 18 days and median hospital stay was 12 days. There were significant differences between operation type and minor complication and hospital stay. And there were significant differences between time gap in 24 hours and minor complication. But, there were no significant between time gap and mortality. Conclusion: Although this study had many limitations, some valuable information was produced. When operation above 24 hours was delayed in SBI, minor complications were significantly increased. Segmental resection of small bowel in SBI were significantly increased minor complications and hospital stay. So, preventive measures for surgical site infection was important to reduce wound complication and hospital stay. Further continuous study and multi-center study were should be performed to improve clinical outcome in SBI.

Analysis of RCSTP Sewage Characteristics and Treatment Efficiency in Rural Area (농촌 지역 마을하수도 유입 하수 특성과 효율 분석)

  • Im, Jiyeol;Jung, Donggi;Gil, Kyungik
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.851-858
    • /
    • 2012
  • This study conducted a result analysis on operation of 26 Rural Community Sewage Treatment Plant (RCSTP) newly constructed in Yeong-yang, Bong-hwa and An-dong areas which are located at the upper region of An-dong Dam and Im-ha Dam. Based on operation result, an analysis on characteristics of sewage in each area and the treatment efficiency of the installed treatment process was conducted. The result of analysis on characteristics of sewage has shown the difference in concentration of the sewage according to area characteristics. Sewage in areas with frequent occurrence of agricultural water and livestock wastewater had high concentration. It is important to select the most suitable treatment process when selecting a treatment process for RCSTP according to properties of sewage in each area. As a result of operation, the disposal efficiency for organic matter and suspended solids was stable with less fluctuation, but the disposal efficiency for nitrogen and phosphorus showed high fluctuation. This signifies that it is necessary to pay attention to operation condition management of nitrogen and phosphorus when operating RCSTP.