• Title/Summary/Keyword: Operation Rule

Search Result 529, Processing Time 0.027 seconds

Parallel reservoirs system operation using NYC-Space Allocation-Rule (NYC-Space Allocation Rule을 이용한 병렬저수지 연계운영)

  • Park Ki-Bum;Lee Soon-Tak
    • Journal of Environmental Science International
    • /
    • v.14 no.6
    • /
    • pp.533-542
    • /
    • 2005
  • In this study, an optimization technique was developed from the application of Allocation Rule. Average Allocation coefficients of the Andong and Imha dam compare constant water supply condition with vary water supply condition that are above the contribute ratio $67\%\~50\%$ the Andong dam in Rule(A)-Rule(C). In the Refill Season, Andong dam water supply contribution is higher than Imha dam at the Control point water supply. In the Allocation analysis results, Rule(A) is calculated storage ratio because Andong dam contribute to Control point larger than Imha dam which Andong dam storage is larger than Imha dam storage. Rule(B) calculated sum of the storage and inflow ratio for Andong dam and Imha dam, as Andong dam contribution is higher than Imha dam. Rule(C) calculated that sum of storage, inflow and water supply is divided average storage ratio, as the best results of the Allocation coefficients and water supply capacity. The results of storage analysis is larger vary water supply condition than constant water supply condition and the results of water supply analysis is larger vary water supply condition than constant water supply condition. Water supply deficit is decrease $30\%$ for vary water supply condition.

A Study on the Operation and Personal Information Management of Public and Private Kindergarten Homepages (공·사립 유치원 홈페이지의 운영 및 개인정보 관리 실태 연구)

  • Kim, Jong Min;Chun, Hui Young;Choi, Eun A
    • Korean Journal of Child Studies
    • /
    • v.37 no.6
    • /
    • pp.119-132
    • /
    • 2016
  • Objective: The purpose of this study was to analyze the operation and personal information management of public and private kindergarten homepages. Methods: A total of 2,846 kindergartens were selected from the I-Sarang portal service for analyzing operation, and 217 self-operating homepages were selected for evaluating management. Seven evaluation items from three domains (information gathering procedures and scope, information security, and management of file exposure protection) were used. Wireshark and Google were used for analyzing some evaluation items. Results: The operating ratio of kindergarten homepages was low and most of the kindergartens self-operated their homepages. The evaluation of the information gathering procedures and scope showed that the rule of consent process was not rigidly followed but that the rule of legality for information gathering was followed. Items related to information security were followed at very low levels. As for the management of file exposure protection, the evaluation of items related to the prevention of attachment disclosure showed that the rule of protecting personal information included in an attached file was followed but that the notice regarding information protection was not. Across all evaluation items, the level of personal information management was higher in public (vs. private) kindergartens. Conclusion: These results indicate methods to more securely and effectively manage personal information on kindergarten homepages.

Development of an Expert System (ESRCP) for Failure Diagnosis of Reactor Coolant Pumps (원자로냉각재펌프 고장진단을 위한 전문가시스템의 개발)

  • Cheon, Se-Woo;Chang, Soon-Heung
    • Nuclear Engineering and Technology
    • /
    • v.22 no.2
    • /
    • pp.128-138
    • /
    • 1990
  • This paper presents a prototype expert system (ESRCP) for Reactor Coolant Pumps. The purpose of this system is to diagnose RCP failures and to offer corrective operational guides to plant operators. The first symptoms for the diagnosis are the alarms which are related to the RCP domain. Alarm processing is required to find a primary causal alarm when multiple alarms occur. The system performs the alarm processing by rule-based deduction or priority factor operation. To diagnose the RCP failure, the system performs rule-based deduction or Bayesian inference. Various sensor readings are required as symptoms to infer a root cause. When the symptoms are insufficient or uncertain to diagnose accurately, Bayesian inference is performed.

  • PDF

Operating Rules for Allocating Storage among Reservoirs in Parallel for Coordinated Operation (연계 운영을 위한 병렬 저수지의 저수량 할당 방안)

  • Lee, Yong-Dae;Jeon, Seung-Mok;Kim, Sheung-Kown;Ko, Ick-Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.343-348
    • /
    • 2006
  • 본 연구에서는 병렬로 구성된 저수지군 연계 운영을 위하여 병렬 저수지의 저수율에 대한 상대적 가중치를 고려한 저수량 할당 방안을 제시한다. 이를 위하여 기존 문헌 등에서 제시된 NYC Rule(New York City Water Supply Rule), Space Rule, 등가 저수위 등의 운영 방안을 낙동강수계 연계운영에 적용하여 용수공급 측면에서 비교하였다. 그리고 Space Rule을 변형하여 각 저수지의 저수율에 대한 상대적 가중치를 설정하고, 이를 바탕으로 불학실성을 감안한 실시간 모의 운영을 진행하여 기존 운영 방안과 효과를 비교 분석해 보았다. 이와 같이 제시된 방안은 실시간 운영, 최적화 모형의 가중치 설정, 유역 시뮬레이션 모형의 저수지 운영방안 설정 등에 활용이 가능할 것이다.

  • PDF

A study on Multi-Attribute AGV Dispatching Rules (다요소를 고려한 AGV 배송규칙에 관한 연구)

  • 이찬기
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1999.04a
    • /
    • pp.184-188
    • /
    • 1999
  • The performance of an AGV varies with the applied AGV dispatching rule in the operation of AGVS. This study proposes a multi-attribute AGV dispatching rule. The suggested dispatching rule considers the output queue of a workstation, distance between an idle AGV and a workstation to be served, the input queue of the destination and the remaining job process of a part. This study suggests two types of and the remaining job process of a part. This study suggests two types of multi-attribute dispatching rules. One is an one-stage rule which selects the part to be served considering four attributes simultaneously. The other is a two-stage rule by which a workstation is selected and a part is chosen from the selected workstation. The simulation runs were executed under different experimental conditions to obtain preliminary statistics on the several performance measures.

  • PDF

A study on sequencing of Mixed Model Assembly Line for increasing productivity (혼합모델조립라인의 생산성 제고를 위한 작업순서 결정)

  • 최종열
    • Korean Management Science Review
    • /
    • v.13 no.2
    • /
    • pp.25-48
    • /
    • 1996
  • Mixed Model Assembly Lines (MMALs) are increasingly used to produce differentiated products on a single assembly line without work-in-process storage, Usually, a typical MMAL consists of a number of (1) stations doing exactly the same operation on every job, (2) stations involving operations with different choices, and (3) stations offering operations that are not performed on every job, or that are performed on every job but with many options. For stations of the first type there is no sequencing problem at all. However, for the second type a set-up cost is incurred each time the operation switches from one choice to another. At the third type of stations, different models, requring different amounts and choices of assembly work, creates an uneven flow of work along the line and variations in the work load at these stations. When a subsequence of jobs requires more work load than the station can handle, it is necessary to help the operations at the station or to complete the work elsewhere. Therefore, a schedule which minimize the sum of set-up cost and utility work cost is desired. So this study has developed Fixed Random Ordering Rule (FROR), Fixed Ascending Ordering Rule (FAOR), Fixed Descending Ordering Rule, and Extended NHR (ENHR). ENHR is to choose optimal color ordering of each batch with NHR, and to decide job sequence of the batch with it, too. As the result of experiments, ENHR was the best heuristic algorithm. NHR is a new heuristic rule in which only the minimum addition of violations from both partial sequence and unassigned sequence at every branch could be considered. And this is a heuristic sequencing rule for the third type of stations at MMAL. This study developed one more heuristic algorithm to test the performance of NHR, which is named as Practical Heuristic Rule (PHR).

  • PDF

Optimization of Multi-reservoir Operation considering Water Demand Uncertainty in the Han River Basin (수요의 불확실성을 고려한 한강수계 댐 연계 운영 최적화)

  • Chung, Gun-Hui;Ryu, Gwan-Hyeong;Kim, Joong-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.1
    • /
    • pp.89-102
    • /
    • 2010
  • Future uncertainty on water demand caused by future climate condition and water consumption leads a difficulty to determine the reservoir operation rule for supplying sufficient water to users. It is, thus, important to operate reservoirs not only for distributing enough water to users using the limited water resources but also for preventing floods and drought under the unknown future condition. In this study, the reservoir storage is determined in the first stage when future condition is unknown, and then, water distribution to users and river stream is optimized using the available water resources from the first stage decision using 2-stage stochastic linear programming (2-SLP). The objective function is to minimize the difference between target and actual water storage in reservoirs and the water shortage in users and river stream. Hedging rule defined by a precaution against severe drought by restricting outflow when reservoir storage decreases below a target, is also applied in the reservoir operation rule for improving the model applicability to the real system. The developed model is applied in a system with five reservoirs in the Han River basin, Korea to optimize the multi-reservoir system under various future water demand scenarios. Three multi-purposed dams - Chungju, Hoengseong, and Soyanggang - are considered in the model. Gwangdong and Hwacheon dams are also considered in the system due to the large capacity of the reservoirs, but they are primarily for water supply and power generation, respectively. As a result, the water demand of users and river stream are satisfied in most cases. The reservoirs are operated successfully to store enough water during the wet season for preparing the coming drought and also for reducing downstream flood risk. The developed model can provide an effective guideline of multi-reservoir operation rules in the basin.

Flood Control Operation of Soyang and Choongju Reservoirs by the Min-max DP (Min-Max DP에 의한 소양 및 충주호의 홍수조절운영)

  • 오영민;이길성
    • Water for future
    • /
    • v.19 no.4
    • /
    • pp.339-346
    • /
    • 1986
  • A real-time single reservoir operation model using the Min-max Dynamic Programming for the flood control of Soyanggang Dam and Choongju Dam is developed. The objective function is to minimize the maximum release from each dam and the constraints are those from ther reservoir and channel characteristics. Control and utilization efficiencies are used to measure the performance of the reservoir operation method (ROM). In comparison with those of simulation models(such as the Rigid ROM, the Technical ROM and the Linear Decision Rule), the efficiencies of the optimization model are superior for all return periods.

  • PDF

Affecting Water Supply Capacity Followed by Allocating Flood Control Volume in Heightening Reservoir (홍수조절용량 설정에 따른 증고저수지의 용수공급능력 변화)

  • Noh, Jae-Kyoung
    • KCID journal
    • /
    • v.17 no.2
    • /
    • pp.57-70
    • /
    • 2010
  • This study was performed to analyze the affect of water supply capacity followed by allocating flood control volume in heightening reservoir, of which Baekgog reservoir was selected as a case study in here. Baekgog reservoir is located in Jincheon county, Chungbuk province, of which full water level will be heightened from EL. 100. 1m to EL. 102.1m, and total storage from 21.75M $m^3$ to 26.67M $m^3$. Flood inflow with 200year frequency was estimated to 997 $m^3$/s in peak flow and 22.54M $m^3$ in total volume. Reservoir flood routing was conducted to determine flood limited water levels, which was determined to have scenarios such as EL 97-98-99m in periods of 6.21.-7.20., 7.21.-8.20., and 8.21.-9.20., respectively, EL 97-97-97m, EL 98-98-98m in present reservoir, and EL 99-100-101m, EL 99-99-99m, and EL 100-100-100m in heightened reservoir. Reservoir inflow was simulated by DAWAST model. Annual paddy irrigation requirement was estimated to 33.19M $m^3$ to 2,975ha. Instream flow was allocated to 0.14mm/d from October to April. Operation rule curve was drawn using inflow, irrigation and instream flow requirements data. In case of withdrawal limit reservoir operation using operation rule curve, reduction rates of annual irrigation supply before and after flood control by reservoir were 2.0~4.3% in present size and 1.5~3.6% in heightened size. Reliability on water supply was decreased from 77.3% to 63.6~68.2% in present size and from 81.6% to 72.7~79.5% in heightened size. And reduction rates of water storage at the end of year before and after flood control by reservoir were 7.3~16.5% in present size and 7.7~16.9% in heightened size. But water supplies were done without any water deficiency through withdrawal limit reservoir operation in spite of low flood regulating water level.

  • PDF

A Study on Remarshaling Operation in Automated Container Terminal (시뮬레이션을 이용한 자동화 컨테이너터미널의 이적운영규칙에 관한 연구)

  • 윤원영;이주호;최용석
    • Journal of the Korea Society for Simulation
    • /
    • v.12 no.3
    • /
    • pp.21-29
    • /
    • 2003
  • The operation rules to remarshaling works in yard is very important in automated container terminal (ACT). However, the decision rules for conventional container terminals have some restrictions to be applied to ACT whose block layout Is vortical for berth. The objective of this study is to propose the efficient operations rules for remarshaling works of automated transfer crane (ATC) in ACTs. Then, the various operation rules are simulated to verify the proposed operation rules. The results of the simulation study on various rules are provided and discussed.

  • PDF