• Title/Summary/Keyword: Operation Deviation

Search Result 427, Processing Time 0.031 seconds

Dynamic Paralleling Behaviors of High Power Trench and Fieldstop IGBTs

  • Wu, Yu;Sun, Yaojie;Lin, Yandan
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.788-795
    • /
    • 2014
  • This paper demonstrates the dynamic behaviors of paralleled high power IGBTs using trench and fieldstop technologies. Four IGBTs are paralleled and standard deviation is adopted to represent the imbalance. Experiments are conducted under three different operation conditions and at different temperatures ranging from $-25^{\circ}C$ to $125^{\circ}C$. The experimental results show that operation at very low and very high temperatures usually aggravates the switching behaviors. There is a trade-off between the balance and the losses at low temperatures. These results can help in the design of heat sinks in paralleling applications confronting very low temperatures.

Output improvement on human power generator (휴먼파워 제너레이터에 관한 출력 개선)

  • Han, Seok-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.204-205
    • /
    • 2016
  • Human power is not dependent on other energy sources, but rather is a source of power for ourselves. Human power, the cleanest energy in the world, can be our future. Therefore, we should be interested in sustainable alternative energy. This paper solves the uneven power generation by utilizing the energy storage capability of the flywheel. Therefore, it improved the efficiency by 5% compared to the existing generation method. DC generators produce power at variable speed operation. The constant voltage was generated from the DC-DC converter to the duty ratio control. Therefore, the charging efficiency is improved by 5% by the constant voltage charging of the battery. And it can suppress the decrease of the output due to the circulation current due to the deviation of the output voltage in parallel operation of the pedal generator.

  • PDF

A Study on temperature behavior of pulsating heat pipe with different diameter in evaporator (증발부 내경 변화에 따른 진동형 히트파이프의 온도 거동에 관한 연구)

  • Kim, Jihoon;Park, Chulwoo;Shah, Syed Abdullah;Kim, Daejoong
    • Journal of the Korean Society of Visualization
    • /
    • v.17 no.1
    • /
    • pp.10-18
    • /
    • 2019
  • In this study, the temperature behavior of Pulsating Heat Pipe (PHP) according to the diameter change were studied by limiting the diameter change to only the evaporator. To investigate operation of PHP in various heat input, heat input power was increased from 10 to 120 W. The results show operation can be divided into 3 regimes by temperature behavior. Thermal resistance was increased before start-up and decreased with increasing heat input. At 110 W heat input, thermal conductivity of 2 mm PHP was 8 .times higher compare to thermal conductivity of copper. Further, to investigate details of temperature behavior in higher heat input, FFT analysis was conducted. Based on the results, when the deviation of peak frequency in each section is lowest, the thermal resistance has lowest value.

Estimation on the Regions of Freshwater Influence using the Seasonal Salinity Data in Asan Bay Coastal Zone (계절별 염분 자료를 이용한 아산만 연안의 담수 영향범위 추정)

  • Cho, Hong-Yeon;Cho, Beom-Jun;Kim, Sang-Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.2
    • /
    • pp.219-231
    • /
    • 2008
  • This study analyzes a general pattern of the gate operation at the Asan bay seadikes and its effects on salinity. The coefficient of determination between precipitation and released freshwater from gate operation turns out to be 0.77-0.89. A stratification is not shown in the analysis of the salinity in upper and lower layers at the Asan bay because of strong tidal effects, and the coefficient of determination between runoff and salinity is in the range of 0.49-0.62 except station Daesan 4. Salinity observations from 8 stations show mean and standard deviation are highly correlated (coefficient of determination=0.9936), and both mean and standard deviation are influenced by freshwater. Eventually it is found that stations Asan 2 to 4 and Daesan 1 are within the regions of the freshwater influences.

Garbage Collection Method for NAND Flash Memory based on Analysis of Page Ratio (페이지 비율 분석 기반의 NAND 플래시 메모리를 위한 가비지 컬렉션 기법)

  • Lee, Seung-Hwan;Ok, Dong-Seok;Yoon, Chang-Bae;Lee, Tae-Hoon;Chung, Ki-Dong
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.9
    • /
    • pp.617-625
    • /
    • 2009
  • NAND flash memory is widely used in embedded systems because of many attractive features, such as small size, light weight, low power consumption and fast access speed. However, it requires garbage collection, which includes erase operations. Erase operation is very slow. Besides, the number of the erase operations allowed to be carried out for each block is limited. The proposed garbage collection method focuses on minimizing the total number of erase operations, the deviation value of each block and the garbage collection time. NAND flash memory consists of pages of three types, such as valid pages, invalid pages and free pages. In order to achieve above goals, we use a page rate to decide when to do garbage collection and to select the target victim block. Additionally, We implement allocating method and group management method. Simulation results show that the proposed policy performs better than Greedy or CAT with the maximum rate at 82% of reduction in the deviation value of erase operation and 75% reduction in garbage collection time.

Dynamic simulation of a solar absorption cooling system (태양열을 이용한 흡수식 냉방기의 동특성 시뮬레이션)

  • 정시영;조광운
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.784-794
    • /
    • 1998
  • The present study has been directed at developing thermal models to investigate the dynamic behavior of a solar cooling system including an absorption chiller, solar collectors, a hot water storage tank, a fan coil unit, and the air-conditioned space. The operation of the system was simulated for 8 hours in two different operation modes. In the mode 1, the system operated without any capacity control.0 the mode 2, an auxiliary boiler supplied heat to the generator if hot water temperature became lower than a certain value. Moreover, the mass flow rate of hot water to the generator was controlled by comparing the instantaneous room air temperature with the design value. The variation of temperature and concentration in the system components and that of heat transfer rates in the system were obtained for both modes of operation. It was found that the room temperature was maintained near the desired value in the mode 2 by supplying auxiliary heat or controlling the mass flow rate of hot water, while the deviation of room temperature was quite great in the mode 2.

  • PDF

A Study on the On-Line Fuzzy ULTC Controller Design Based on Multiple Load Center Points (다중 부하중심점에 기반한 온라인 퍼지 ULTC 제어기 설계에 대한 연구)

  • Ko, Yun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.12
    • /
    • pp.514-521
    • /
    • 2006
  • The existing ULTC operation control strategy based on the measured data deteriorates the voltage compensation capability making the efficient corresponding to the load variation difficult by following the fixed load center point voltage. Accordingly, this paper proposes a new on-line fuzzy ULTC controller based on the designed multiple load center points which can improve the voltage compensation capability of ULTC and minimize voltage deviation by moving in real-time the load center point according to the load variation to an adequate position among the multiple load center points designed using the clustering technique. The Max-Min distance technique is adopted as the clustering technique for the decision of multiple load points from measured MTr load current and PTr voltage, and the minimum distance classifier is adopted for the decision of fuzzy output membership function. To verify the effectiveness of the proposed strategy, Visual C++ MFC-based simulation environments is developed. Finally, the superiority the proposed strategy is proved by comparing the fuzzy ULTC operation control results based on multiple load center points with the existing ULTC operation control results based on fixed load center point using the data for three day.

Development of simulator by induced contact loss phenomenon for high-speed train operation (고속전철 주행에 따른 이선현상 모의 시뮬레이터 개발)

  • Kim, Jae-Moon;Kim, Yang-Soo;Kim, Chul-Soo;Chang, Chin-Young;Kim, Youn-Ho
    • Proceedings of the KSR Conference
    • /
    • 2009.05b
    • /
    • pp.499-503
    • /
    • 2009
  • In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated from an electrical response point of view. To analysis power line disturbance by induced contact loss phenomenon for high speed operation, a hardware Simulator which considered contact loss between contact wire and the pantograph as well as contact wire deviation is developed. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system. One of the most important needs accompanied by increasing the speed of high-speed train is reduced that an arc phenomenon by loss of contact brings out EMI. In case of a high-speed train using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI, dummy signal injection etc usually occurs. Throughout experiment, it is verified that an arc phenomenon is brought out for simulator operation and consequently conducted noise is flowed in electric circuit by power line disturbance.

  • PDF

The effect of earnings volatility on current stock price informativeness about expectations of future earnings (이익 변동성이 현재 주가의 미래 이익 기대에 대한 정보성에 미치는 영향: 미국기업을 중심으로)

  • Joong-Seok Cho
    • Asia-Pacific Journal of Business
    • /
    • v.13 no.4
    • /
    • pp.109-121
    • /
    • 2022
  • Purpose - This study investigates how earnings volatility influences current stock price informativeness about expectations of future earnings. Design/methodology/approach - I adopt the FERC model developed by Collins et al. (1994) and modified by Lundholm and Myers (2002) to investigate the connection between earnings volatility and future earnings reflected in current returns. I define five-year rolling standard deviations of earnings and components as earnings volatility measures and the degree of deviation of earnings from cash flows over the same five-year, which is developed by Jayaraman (2008). Finding - My results show that earnings volatility delays current stock price response to future operation expectations. They also verify that as earnings are more divergent from cash flows, current returns are less timely incorporating value-relevant future operation. Research implications or Originality This study shows that when volatile earnings deliver obscure and unreliable information about future operation expectations, they cause the market to be conflicting in understandings their implications and make it difficult in attaining correct future cashflow estimates.

Rapid, Two-Stage Arterial Switch for Transposition of the Great Arteries with Intact Ventricular Septurn Beyond the Neonatal Period -A Case Report (신생아기를 넘긴 대혈관 전위증 환아에서 단기간에 걸친 2단계 동맥 전환술 -1례 보고-)

  • Yang, Hyeon-Ung;Choe, Jong-Beom
    • Journal of Chest Surgery
    • /
    • v.30 no.11
    • /
    • pp.1121-1124
    • /
    • 1997
  • This is a report of a successful, rapid two-stage arterial switch operation in an infant with dextrotransposition of great arteries with an intact ventricular septum beyond the appropriate time for arterial switch operation.'A 4-month-old female infant was admitted due to severe cyanosis, respiratory insufficiency, and frequent dia rhea secondary to ischemic colitis. Echocardiographic examination presented marked leftward deviation of the interventricular septum, and left and right ventricular pressures as measured by cardiac catheterization were 40/4 mmHg and 85/2 mmHg, respectively. Fifteen days after a preparatory operation (pulmonary artery band with modified right Blalock-Taussig shunt), left ventricular-right ventricular systolic pressure ratio increased to 105/90. Arterial switch operation associated with the division of the right Blalock-Taussig shunt and the removal of pulmonary artery band was performed. A(leer the operation, the infant showed normal cardiac function with no postoperative complication.

  • PDF