• Title/Summary/Keyword: Operation Department

Search Result 13,741, Processing Time 0.046 seconds

Surgical Treatment for Acute Acromioclavicular Joint Dislocation (급성 견봉쇄골관절 탈구의 수술적 치료)

  • Kim Jeong Hwan;Kim Chong Kwan;Lee Saeng Guk;Kim Young O;Park Jae Kyu;Yoon Jong Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.4 no.1
    • /
    • pp.17-23
    • /
    • 2001
  • There has been considerable controversy concerning the methods for treatment of dislocation of the acromioclavicular joint, especially in grade III injury. The authors have treated 24 cases of the complete dislocation of the acromioclavicular joint from January 1990 to July 2000. We performed 14 cases of coracoclavicular wiring operation, 10 cases of modified Phemister operation and compared the results and complication of wiring operation with modified Phemister. The clinical results in modified phemister operation were excellent in 8 cases(80%), good in 1 case(l0%), fair 1 case(10%). In wiring operation, excellent is 11 case(78%), good is 2 case(14%), fair is 1 case(14%). The complications of modified Phemister operation were breakage and migration of K-wire in 2 cases. In wiring operation, breakage of wire was in 2 cases but migration was not showed. We prefered coracoclavicular wiring operation for dislocation of acromioclavicular joint of active young adults because of the following advantages: 1) violation of acromioclavicular joint can be avoided but rotation of the clavicle was not restricted. 2) The operation is simple to perform. 3) Postoperative immobilization is minimal. 4) Removal of the wire is easy because wire was not migrated when breakage of wire was occured.

  • PDF

The Anti-islanding Scheme for a Number of Grid-connected Inverters Under Parallel Operation (병렬 연결된 다수 대 계통연계형 인버터를 위한 단독운전 방지 기법)

  • Kim, Dong-Kyune;Cho, Sang-Rae;Choy, Ick;Lee, Young-Kwoon;Choi, Ju-Yeop
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.3
    • /
    • pp.13-22
    • /
    • 2017
  • Anti-islanding scheme of grid-connected inverter is a key function of standards compliance, since unintentional islanding results in safety hazards, reliability, and many other issues. Therefore, many anti-islanding schemes have been researched, however, most of them have problems, which deteriorate performance of islanding detection under parallel-operation. Therefore, this paper proves the reason of problems and proposes a new anti-islanding scheme that has precise islanding detection under parallel-operation in single-phase and three-phase system. Finally, both simulation and experimental result validate the proposed scheme.

Aortic Root Reimplantation in a Patient Who Underwent an Arterial Switch Operation

  • Kwon, Young Kern;Kang, Seung Ri;Park, Sung Jun;Kim, Wan Kee;Kim, Joon Bum
    • Journal of Chest Surgery
    • /
    • v.51 no.6
    • /
    • pp.395-398
    • /
    • 2018
  • Neo-aortic insufficiency associated with root enlargement following an arterial switch operation is a serious late complication. To achieve successful surgical correction of this condition, multiple factors should be considered, including the individual patient's anatomy, the challenging nature of the redo procedure, and the patient's young age. However, limited publications have described the use of valve-sparing techniques for the treatment of neo-aortic insufficiency associated with root enlargement following an arterial switch operation. Herein, we report our recent experience of a valve-sparing aortic root procedure with ascending aorta and hemiarch replacement despite the presence of a discrepancy in leaflet size and nearby severe adhesions.

COMPUTER SIMULATION OF TRACTOR PERFORMANCE WITH REGARD TO ENERGY SAVING AND POLLUTION REDUCING

  • Zou, Cheng;Sakai, Jun;Nagata, Masateru
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.1110-1116
    • /
    • 1993
  • A study on optimum operation performances of power efficiency, economy and exhaust emissions for a tractor was conducted. A mathematical model of multiple degree polynomial equation was applied to established the function of solid multiple parameter curves for specific fuel consumption (ge), cabon monoxide (CO) ,hydrcarbons (HC) and cabonaceous smoke (Rb). The optimum operation theorems for economy operation indicated by ge and for exhaust emissions described by Co , HC and Rb were obtained from analytical method and performance test data. The optimum operation theorems could exhibit optimum operation working points, curves, and regions. The optimum matching relations of engine speed and transmission parameters were analyzed by using computer simulation methods in accordance with the tractor specifications , actual farm working conditions in a typical drawbar pull work such as plowing , the optimum operation objective function, the ideal transmission ratio, practical gear shif ing positions and practical travel speed of the tractor TN55 medel. The results of the anlayzes indicated clearly that the optimum power efficient operation, energy saving and pollution reducing would be realized if the tractor would be operated according to theoptimum operation methods.

  • PDF

Concomitant or Delayed Intra-abdominal Operation in Immediate Breast Reconstruction with TRAM Flap (횡복직근피판술을 이용한 즉시 유방재건과 동시 혹은 후에 시행한 복강 내 수술)

  • Kim, Kyu-Nam;Lee, Taik-Jong
    • Archives of Plastic Surgery
    • /
    • v.37 no.1
    • /
    • pp.22-25
    • /
    • 2010
  • Purpose: As patients who take immediate breast reconstructions with TRAM flap have increased, concomitant or delayed other elective intra-abdominal operations in these patients also have increased. There are few reports of concomitant or delayed intra-abdominal operation in TRAM flap patients. We report our experiences and outcomes of these operations which is safe and feasible. Methods: We reviewed the charts and postoperative follow-up results of 11 patients among 471 consecutive patients who took immediate breast reconstruction with TRAM flap from December of 2002 to September of 2006. Four patients took concomitant intra-abdominal operation and 7 patients took delayed intra-abdominal operation between 1 to 52 months after TRAM flap Results: There were no significant postoperative abdominal and systemic complications. One patient who took concomitant intra-abdominal operation presented partial skin necrosis of abdomen, but recovered completely with conservative treatments. Two patients took transfusion in peri-operative periods. Conclusion: Concomitant or delayed intra-abdominal operation in immediate breast reconstruction with TRAM flap could be performed safely and feasibly when it is necessary. Furthermore, it could be helpful to patients and surgeons.

Re-pull-through Operation in Hirschsprung's Disease (Hirschsprung 병에서의 재 교정 수술의 성적)

  • Kim, Hyun-Young;Park, Kwi-Won;Chun, Yong-Soon;Jung, Seung-Eun;Lee, Seong-Cheol;Kim, Woo-Ki
    • Advances in pediatric surgery
    • /
    • v.10 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • A re-pull-through operation for Hirschsprung's disease is performed when the primary operation has failed because of the remnant or acquired aganglionosis, anastomotic stricture and/or fistula. The purpose of this study is to review our experience of the re-pull-through procedure for Hirschsprung's disease. From May 1978 to July 2003, 26 patients who underwent re-pull-through operations at the Department of Pediatric Surgery, Seoul National University Children's Hospital, were studied retrospectively by means of chart review as well as telephone interview. The mean age at primary operation and re-operation were llmonths (2 months - 10 years) and 43 months (1 year - 23 years 3 months), respectively. Initial operation for Hirschsprung's disease was Duhamel's procedure in 17, Swenson's in 6 and Soave's 3. Causes of failure of primary operation were remains of secondary aganglionic segment (n=23), vascular arcade injury (n= 1), rectoperineal fistula (n=2, due to mesenteric torsion and poor blood supply), Mean interval between the primary operation and the re-operation was 34 months (6 months-22 years). Reoperation methods were Soave's in 12, Duhamel's in 8, APSP (abdomino-posterosagittal pull-through procedure) in 5, and Swenson's in 1 case. In 2 cases of repeated rectoperineal fistula or rectourethral fistula, re-APSP were performed 3 times, respectively. A total of 29 re-pull-through operations were performed. Postoperative complications were wound infection (n=1), adhesive ileus (n=1), rectoperineal fistula (n=3), rectourethral fistula (n=2), and death due to pulmonary embolism (n=1). Mean follow up period of reoperation was 78 months (1 month-23years). In current state, 2 patients have an ileostomy because of repeated rectoperineal fistula and rectourethral fistula. Of the remaining 23 patients, 21(91 %) are totally continent with or without minimal soiling. Reoperation for Hirschsprung's disease was effective and safe for the patients complicated to the initial pull-through operation.

  • PDF

Comparison of Customer Satisfaction by Operation Types of Business Foodservice in Chungbuk Province (충북지역 사업체 급식소의 운영형태에 따른 고객 만족도 비교)

  • An, Kwang-Bok;Yon, Mi-Yong;Lee, Yu-Jin;Kim, Woon-Ju
    • Journal of the Korean Society of Food Culture
    • /
    • v.24 no.6
    • /
    • pp.721-727
    • /
    • 2009
  • In this study, the current status of the business foodservice industry, evaluation of leftover food and customer satisfaction with foodservice at direct operation and consignment foodservice businesses in Chungbuk were examined. This study has managerial implications in terms of improving the quality and effectiveness of the business operation of the foodservice industry. The sample size of this study included 800 customers who use foodservices provided by 11 selected businesses including 6 direct operation and 5 consignment foodservice businesses. From these 800 customers, a total of 692 were used (direct operation foodservice (n=361) and consignment foodservice (n=331) businesses). The results were as follows; First, as for the main reasons for using the employee restaurants in types of direct operation and consignment foodservice business, 'the close location' had the high percentage. Approximately 41% of respondents were not satisfied with the foodservice in the employee restaurants. Second, leftover food from consignment foodservices was higher than that for direct operation foodservices. Third, there were significant differences in customer satisfaction with five areas of foodservice between the two types of food service businesses: food, sanitation, feeding environment, mealing process and information and service. Customer satisfaction in the direct operation foodservice was higher than that of the consignment foodservice. In terms of the satisfaction level of foodservices, mealing process was the highest, followed by sanitation, food, and information and service in the direct operation and consignment foodservice businesses. Overall, satisfaction with the business foodservice was affected by the customers' satisfaction in five areas of foodservices (e.g., food, sanitation, feeding environment, mealing process, information and service). Especially, 'food' and 'information and service' were important areas for determining overall customer satisfaction with foodservice. In addition, the overall satisfaction was negatively correlated with the quantity of leftover food in the direct operation and consignment foodservice business.

The 2004 Cleft Lip and Palate Charity operation in Vietnam and 10-Year Review (2004년 베트남 구순구개열 무료수술 및 10주년 봉사 활동에 관한 보고)

  • Ahn Kang-Min;Yu Soon-Yong;Cho Jin-Young;Kim Jong-Ryoul;Kim Myung-Jin;Oh Yong-Seok;Tri Tri;Min Byong-Il
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.7 no.2
    • /
    • pp.141-150
    • /
    • 2004
  • The cleft lip and palate charity operation team visited Binh Duong General Hospital in Vietnam from 17th Dec to 25th Dec 2004. Total 25 cleft lip and palate patients (male : female = 15:10) were undergone the operation. The mean age of the patients was 13.6 year. The types of surgical operation were primary cheilorrhaphy (8 cases), primary palatorrhaphy(10 cases), pharyngoplasty(2 cases), scar revision(3 cases), alveolorrhaphy(2 cases). There were no intraoperative and immediate postoperative complications. The year 2004 was the 10th charity operation in the same area so it is meaningful to review the start of this charity mission and the course, and the future of our activity.

  • PDF

A Study on Boost/Flux-Weakening Controller for Wide Speed Operation Range having Engine and IPMSG for Special Equipment Vehicle (특수차량용 엔진 직결형 IPMSG의 넓은 속도운전 범위를 위한 부스트/약자속 제어기에 관한 연구)

  • Lee, Sang-Geon;Kim, Sung-An;Cho, Yun-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.8
    • /
    • pp.54-61
    • /
    • 2014
  • This paper proposes a boost/flux-weakening controller (BFWC) for wide speed operation range having engine and interior permanent magnet synchronous generator (IPMSG) for special equipment vehicle. The proposed BFWC exploits direct torque/flux control (DTFC) scheme based on space vector modulation method to control the constant DC voltage output within the entire speed operation range of engine. And, to improve the response characteristics of maximum torque per ampere (MTPA) operation and flux-weakening operation, the MTPA and flux-weakening feed-forward controllers are applied. To estimate feasibility and usefulness of the proposed controller, the simulation and experimental results are compared.

Time Complexity Measurement on CUDA-based GPU Parallel Architecture of Morphology Operation

  • Izmantoko, Yonny S.;Choi, Heung-Kook
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.4
    • /
    • pp.444-452
    • /
    • 2013
  • Operation time of a function or procedure is a thing that always needs to be optimized. Parallelizing the operation is the general method to reduce the operation time of the function. One of the most powerful parallelizing methods is using GPU. In image processing field, one of the most commonly used operations is morphology operation. Three types of morphology operations kernel, na$\ddot{i}$ve, global and shared, are presented in this paper. All kernels are made using CUDA and work parallel on GPU. Four morphology operations (erosion, dilation, opening, and closing) using square structuring element are tested on MRI images with different size to measure the speedup of the GPU implementation over CPU implementation. The results show that the speedup of dilation is similar for all kernels. However, on erosion, opening, and closing, shared kernel works faster than other kernels.