• 제목/요약/키워드: Operating unit

Search Result 1,243, Processing Time 0.028 seconds

A control system for dual-axis linear motor

  • Uchida, Yoshiyuki;Nohira, Shigemitsu;Seike, Yoshiyuki;Shingu, Hiroyasu;Sumi, Tetsuo;Furuhashi, Hideo;Yamada, Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10b
    • /
    • pp.340-343
    • /
    • 1992
  • Fundamental positioning characteristics of a dual-axis Sawyer linear motor are described. The Sawyer motor is capable of high positional accuracy. An electronic control unit of the motor whose velocity is proportional to the frequency of the electric current was produced in our laboratory. The positioning system was constructed using two Sawyer motors, an air bearings suspension unit and an electronic control unit. The stable motion of the motor was confirmed on the open loop operation. The adjustable operating conditions were the live load of 1 kg, the maximum acceleration of 1.2G and the maximum velocity of 350 mm/s. Absolute positioning accuracy was improved within .+-.5.mu.m, on microstep operating conditions of dividing one pitch of 508.mu.m into 508 steps. The following two conclusions were obtained. An accelerating-cruising-decelerating control is effective for reduction in the travel time required. Also, microstep operation is effective for improving the resolution of position.

  • PDF

Improvement Strategy by Case Study on the Direct Payment Program for Rural Landscape Preservation: Bonghwa-gun, Chungwon-gun, Hongsung-gun (경관보전직불제 시범사업의 시행사례 분석 및 개선방안: 봉화군, 청원군, 홍성군 사례를 중심으로)

  • Jang, Hyo-Sun;Gim, Uhn-Soon;Um, Dae-Ho
    • Journal of Korean Society of Rural Planning
    • /
    • v.13 no.4
    • /
    • pp.69-77
    • /
    • 2007
  • The purpose of this study is to analyze the problems of operating the Direct Payment Program for Rural Landscape Preservation and to derive the way of improvement based on case study for three areas in Bonghwa-gun, Cheongwon-gun, Hongseong-gun. The most important factor for the program is farmer's consciousness and positive participation of the farmer who are the subject of this project. Even if farmers are not satisfied with the amount of direct payment income, they try to create income by utilizing landscape preservation crops. Particularly current unit payment dose not surpass the for the crops farm operating costs and payment time is not appropriate for the farming cycle. Hence, it needs to be considered increasing unit payment and rearranging the payment time. Also, we need to introduce incentive system based the degree of fulfillment of the Direct Payment Program in each areas. In general the Direct Payment Program for Rural Landscape Preservation has potentiality to contribute farmer's income stability and the vitalization of region with three revisions.

Effect of Operating Conditions of a Fan-Coil Unit with an Oval Tube Type Heat Exchanger on Non-Dimensional Performance Coefficient (타원관 열교환기를 적용한 팬코일 유닛의 운전 조건이 무차원 성능계수에 미치는 영향)

  • Yoon, Jaedong;Lee, Younghoon;Sung, Jaeyong
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2019
  • In this study, the effect of operating conditions of fan-coil unit with an oval tube type heat exchanger on its non-dimensional performance coefficient has been investigated. Pressure drops and heat transfer rates were measured under heating condition for various water flow rates, inlet temperatures and wind speeds. As a non-dimensional performance coefficient, Colburn j-factor was evaluated. The results show that the most sensitive parameter on heat flux is the inlet temperature, which affects the heat flux 4.7 and 7.2 times more than the wind speed and water flow rate, respectively. On the other hand, the Colburn j-factor as a non-dimensionalized index decreases with the wind speed, and has an maximum when the wind speed is about 1 m/s. the Colburn j-factor increases slowly with the water flow rate and inlet temperature but at a certain range of inlet temperature, the opposite phenomenon is found.

A Study on the Flooding Phenomena of Cathode Flow Path with Operating Temperatures in a PEM Fuel Cell (고분자전해질형 연료전지의 작동 온도에 따른 공기극 유로 내 플러딩 현상에 관한 연구)

  • Kim Han-Sang;Ha Taehun;Min Kyoungdoug
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.326-329
    • /
    • 2005
  • Proton exchange membrane (PEM) should be sufficiently hydrated with proper water management to maintain a good ionic conductivity and performance of a PEM fuel cell. However. cathode flooding resulting from excess water can impede the transport of reactants and hence deteriorate the fuel cell performance. For the PEM fuel cell to be commercially viable as vehicle or portable applications, the flooding on the cathode side should be minimized during the fuel cell operation. In this study, visualization technique was applied to understand the cathode flooding phenomena on the cathode side of a PEM fuel cell. To this end. a transparent PEM unit fuel cell wi th an act ive area of $25cm^2$ was designed and manufactured to allow for the visualization of cathode channel with performance characteristics. Two-phase flow resulting from the electro-chemical reaction of fuel cell was investigated experimentally. The images photographed by CCD camera with cell operating temperatures $(30\~50^{\circ}C)$ were presented. Results indicated that the flooding on the cathode side first occurs near the exit of cathode channel. As the operating temperature of fuel cell increases. it was found that liquid water droplets tend to evaporate easily and it can have an influence on lowering the flooding level. It is expected that this study can effectively contribute to the detailed researches on modeling water transport of an operating PEM fuel cell including two-phase flow phenomena.

  • PDF

Miniaturized Frequency Selective Surface with a Scalability of Operating Frequency (동작 주파수 확장성을 갖는 소형화된 주파수 선택 표면구조 설계)

  • Lee, In-Gon;Hong, Ic-Pyo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.6
    • /
    • pp.512-520
    • /
    • 2016
  • In this paper, a miniaturized frequency selective surface(FSS) for bandstop operation that provides stability for an angle of incidence and polarization is presented. The proposed miniaturized FSS has the unit cell of hexagonal structure with triangular loops and size of the unit cell is $0.081{\lambda}{\times}0.081{\lambda}$ at 2.5 GHz operating frequency, which is very small compared to operating wavelength. In addition, unlike the conventional design, which requires complicated design parameters, the proposed FSS is easily expanded to the desired operating frequency for 2~8 GHz, by controlling the specific design parameters. To validate the simulation results, the FSS structures having different operating frequencies, 2.5 GHz, 5 GHz and 8.2 GHz were designed, fabricated and measured. The comparisons between the simulation and the measured results show good agreement. The proposed miniaturized FSS can provide better frequency stability for different incidence angles and polarizations.

Tribological Failure Examples Involving Hydraulic Unit, Sensor, Computer of Anti-lock Brake System in Passenger Cars (승용차 ABS의 하이드로릭 유닛, 센서, 컴퓨터에 관련된 트라이볼로지적인 고장사례 고찰)

  • Lee, IlKwon;Han, JaeOh;Lee, JongHo;Lee, YoungSuk;Kim, ChooHa
    • Tribology and Lubricants
    • /
    • v.30 no.3
    • /
    • pp.183-188
    • /
    • 2014
  • In this paper, we present our analysis of tribological failure examples for an anti-lock brake system(ABS) in a car. The study range of this paper is to improve the quality of ABS system by analyzing with sensor, computer, actuator and oil lines. In the first example, the brake leak from hydraulic supply line in a caliper on the rear left side of the ABS hydraulic modulator. This produces the sponge phenomenon, where the car does not brake even when the driver operates the brake pedal. The hydraulic unit operating ABS is actuator that play role regulating drive condition according with the oil pressure supplied with wheel of a car. In the second example, the service man does not completely tighten the fixed bolt after repairing the car. This causes the ABS warning lamp to light up as the ABS wheel speed sensor cannot detect whether the ABS has been activated. In the third example, the ABS electronic control unit is separated from the soldered part of the inner circuit board. Consequently, the ABS fails in control because the ABS motor pump receives no-signal for the hydraulic unit. The wheel speed sensor has to large durability because of giving signal of acting condition to computer by detected the acceleration and deceleration of wheel of a car. In the fourth example, the ABS warning lamp lights up of when cracks propagate in the circuit board soldering part. The circuit of this computer is very important part for input and output the operating signal of system. Such failures can aggravate the durability of the ABS. Thus, the ABS needs to be optimized to eliminate malfunction phenomenon.

A study on evaluation of information retrieval system (정보검색(情報檢索)시스템의 평가(評価)에 관한 연구(硏究))

  • Park, In-Ung
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.5 no.1
    • /
    • pp.85-105
    • /
    • 1981
  • Information is an essential factor leading the rapid progress which is one of the distinguished characteristics in modem society. As more information is required and as more is supplied by individuals, governmental units, businesses, and educational institutions, the greater will be the requirement for efficient methods of communication. One possibility for improving the information dissemination process is to use computers. The capabilities of such machine are beginning to be used in the process of Information storage, retrieval and dissemination. An important problems, that must be carefully examined is whether one technique for information retrieval is better for worse than another. This paper examines problem of how to evaluate an information retrieval system. One specific approach is a cost accounting model for use in studying how to minimize the cost of operating a mechanized retrieval system. Through the use of cost analysis, the model provides a method for comparative evaluation between systems. The general cost accounting model of the literature retrieval system being designed by this study are given below. 1. The total cost accounting model of the literature retrieval system. The total cost of the literature retrieval system = (the cost per unit of user time X the amount of user time) + ( the cost per unit of system time X the amount of system time) 2. System cost accounting model system cost = (the pre-search system cost per unit of time X time) + (the search system cost per unit of time X time) + (the post search system cost per unit of time X time) 1) Pre-search system cost per unit of time = cost of channel per unit time + cost of central processing unit per unit time + cost of storage per unit time 2) Search system cost per unit of time = comparison cost + document representation cost. 3) Post-search system cost per unit of time. = cost of channel per unit time + cost of central processing unit per unit time + cost of storage per unit time 3. User cost accounting model Total user cost = [pre-search user cost per unit of time X (time + additional time) ] + [search user cost per unit of time X (time + additional time) ] + [post-search user cost per unit of time X (time + additional time) ].

  • PDF

The Effect of Electromagnetic Fields Shielding on Electromagnetic Fields Decrease in P. T Room (차폐천이 물리치료실 환경내 전자기장 감소에 미치는 효과)

  • Lim Chang-Hun;Kim Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.12 no.2
    • /
    • pp.69-82
    • /
    • 2000
  • Physical therapists are exposured to radio-and microwave-frequency electromagnetic radiation by operating electrotherapy units. So there is few protection system in physical therapy room. Clinical pathology room and so on where various kins of electromagnetic instruments is used in hospital while protection failities like protection wall or protection glass is being used only in radiological room to reduce the damage of radiation. Acoording to Larsen's survey on female physical therapist in denmark. it was said that the percentage of congenital malfornation was $3.6\%$ and cadiac malformation made up $0.7\%$. It is likely that effect of electromagnetic fields on the result cannot be ruled out. Rita ouellet-Hellstron and Walter F. Steward insisted that the danger of abortion increase in the case of pregnant femeal physical therapist exposured to microwave diathermy. The intention of our study is arousing the necessity of microwave protection in P.T room and finding the proper method for physical therapist safe. The results of this study were as follows: 1. Each electrotherapy units are occurrenced the electromagnetic fields, and specially amply occurrenced in H.P,I.C.T 2 unit operating, M.W.D unit head on parallel, S.W.D unit head on parallel. all electrotherapy units are operating. 2. There were electric fields mount are consideration to species of electrotherapy units(p<.05). 3. There were magnetic fields mount are consideration to species of electrotherapy units(p<.05). 4. There were electric fields mount are consideration to distance of electrotherapy units(p<.05). 7. There were magnetic fields mount are consideration nut to distance of electrotherapy units(p>.05). 8. Before and after protection on magnetic fields mount are consideration to all distance(0m, 0.3m, 1m, 3m, 5m)(p<.05) 9. Before and after protection on electric fields mount are consideration to 0m, 1m, 3m distance(p<.05), and consideration not to 0.3m, 5m distance(p>.05) 10. After protection fellow the each electrotherapy units. distance, intencity to electromagnetic fields are reduced(p<.05).

  • PDF

Study of Tolerance Suitability of Door Operation Mechanism on Mobile Air Handing Unit Using 3-DCS Analysis (3-DCS를 이용한 자동차 공기 분배장치의 도아 구동 기구의 공차 적합성 분석에 대한 연구)

  • Kim, Jongsu;Lee, Daewoong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.5
    • /
    • pp.527-537
    • /
    • 2016
  • Recent automakers are trying to be more precise with the dimension check and moving parts to guarantee high quality and satisfy customer requirements. The aim of this paper is to investigate the design tolerance suitability of door operating mechanism linked arms, lever, and cam-shaft in a mobile air handling unit. These parts are complicated because doors, arms, lever and cam-shaft are connected nonlinearly in 3D. The current tolerance analysis method poses problems in design analysis because the moving doors are reasonably suitable for the AHU function. The 3-DCS analysis method provided useful results not only in establishing the inspection criteria for the quality control of products but also in enabling economical production. As a result, the vent door had $1.62^{\circ}{\sim}1.72^{\circ}$ and the defrost door had $0.84^{\circ}{\sim}0.9^{\circ}$ for the directly connected arms operating-type. For the lever connected arm operating-type, the foot door had $2.0^{\circ}{\sim}2.24^{\circ}$ tolerance, while the tolerance values satisfied the air flow volume distribution rate criteria in the AHU. Finally, the results have confirmed the design's tolerance suitability by using 3-DCS analysis at the early design stages. Reliability can be achieved by analyzing accumulated tolerance during the sub-parts assembly process and the moving mechanism linked especially by arms, lever, and cam-shaft.

Analysis of a Controllable Queueing Model Operating under the Alternating Operating Policies (변동 운용방침이 적용되는 조정가능한 대기모형 분석)

  • Rhee, Hahn-Kyou
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.1
    • /
    • pp.81-90
    • /
    • 2016
  • Different from general operating policies to be applied for controllable queueing models, two of three well-known simple N, T and D operating policies are applied alternatingly to the single server controllable queueing models, so called alternating (NT), (ND) and (TD) policies. For example, the alternating (ND) operating policy is defined as the busy period is initiated by the simple N operating policy first, then the next busy period is initiated by the simple D operating policy and repeats the same sequence after that continuously. Because of newly designed operating policies, important system characteristic such as the expected busy and idle periods, the expected busy cycle, the expected number of customers in the system and so on should be redefined. That is, the expected busy and idle periods are redefined as the sum of the corresponding expected busy periods and idle periods initiated by both one of the two simple operating policies and the remaining simple operating policy, respectively. The expected number of customers in the system is represented by the weighted or pooled average of both expected number of customers in the system when the predetermined two simple operating policies are applied in sequence repeatedly. In particular, the expected number of customers in the system could be used to derive the expected waiting time in the queue or system by applying the famous Little's formulas. Most of such system characteristics derived would play important roles to construct the total cost functions per unit time for determination of the optimal operating policies by defining appropriate cost elements to operate the desired queueing systems.