• Title/Summary/Keyword: Operating type

Search Result 2,919, Processing Time 0.024 seconds

Competency of Nursing Performance and Job Satisfaction of Operating Room Nurse by Type of Nurse Staffing (간호인력배치유형에 따른 수술실 간호사의 업무수행능력 및 직무만족)

  • Ahn, Young-Mi;Park, Chai-Soon
    • Women's Health Nursing
    • /
    • v.11 no.2
    • /
    • pp.169-175
    • /
    • 2005
  • Purpose: This study was designed to investigate the relationships of the types of nurse staffing, the competency of nursing performance and job satisfaction by analyzing the types of nurse staffing in operating room. Method: The subjects were 472 nurses who work in operating room. The instruments used in this study were three tools: competency of nursing performance, job satisfaction and type of nurse staffing. Result: Type 4 was most in the type of nurse staffing of the subjects. According to the type of nurse staffing, the competency of nursing performance was significantly different. There was significant difference in the competency of nursing performance according to age, marital status, bachelor, employ, position, and career, and job satisfaction according to age, position, and career. In opinion about the ideal type of nurse staffing, type 2 was most regardless of career. Conclusion: Type 4 which has lower competency of nursing performance was adopted in many hospitals now but, type 2 which has highest competency of nursing performance was selected by many nurses as the best one. So, it should be considered the type of nurse staffing of in operating room and change it.

  • PDF

A System Operating Algorithm for the Effective Operation of a Multi-type Air-conditioning System (멀티형공조시스템의 효과적인 운전을 위한 시스템운전알고리즘)

  • Han Do-Young;Park Kwan-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.7
    • /
    • pp.587-595
    • /
    • 2006
  • A system operating algorithm was developed for the effective operation of a multi-type air-conditioning system. The system operating algorithm includes control algorithms for a safety mode, an initial operating mode, a stabilization mode, a fault diagnosis mode, an efficiency mode, and a tracking mode. Various tests were performed to show the effectiveness of these algorithms. Tests showed good results for the operation of a multi-type air-conditioning system. Therefore, these algorithms developed for this study may be used for the effective control of a multi-type air-conditioning system.

Study on The Qptimization of Operating Conditions of batch-type Grain Dryer (평면식 건조기의 적정작업조건 설정에 관한 연구)

  • 박경규;정창주
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.16 no.4
    • /
    • pp.3600-3610
    • /
    • 1974
  • Experimental work of batch-type dryer was conducted to develop its optimurm operating conditions by analyzing the major factors which affect the drying performance. A laboratory batch-type dryer was constructed and tested for various levels of heated-air rates, and depths of grain deposit. Tong-il rice variety having the initial moisture content of approximaely 23 per cent in wet basis was used for the experiment. The criteria selected for establishing the optimum operating condition were the drying performance rate, the thermal efficiency, and the operational cost of the dryer. The results of the study are summarized as follows: 1. The performance rate of dryer for a specific operating condition was defined as total amount of material dried per hour when the moisture content of grains in the upperlayer reaches to 16 per cent in wet basis. The optimum operating conditions as viewed in the rate of drying performance could be justified by functional realtionship between the depth of grain deposit and air flow rate. In other words, there was a definite depth of grain deposit for a given air-rate which make the dryer performance maximum. The optimum grain depth for the batch-type dryer with 3.3㎡ loading area and with the attached axial fan was about 35cm. 2. The thermal efficiency for the dryer was evaluated by the ratio of the latent heat required to evaporate the grain moisture to the heat input required to raise the ambient air-temperature to 40 degree centigrade. The optimum operating condition as viewed in term of thermal efficiency analyzed was that grater depth and lower air flow-rate may be desirable. This condition is contracted with the optimum condition as viewed by the dryer performance rate. 3. The annual operating cost of batch-type dryer was analyzed for different annual hour of use and for different operation condition. The optimum condition as viewed in terms of operating cost was almost identical to one as viewed in terms of dryer performance rate. Therefore, the most economical use of batch-type dryer for the same annual operating hours can be obtained when the dryer operated in the condition of maximum dryer performance rate. Increasing the annual operating hour may be desirable to cut down the dryer operation cost, since the annual hour of dryer use is much sensitive to the operating cost than any peractical conditions of dryer operation. 4. The most desirable operational condition as justified by combining all the criteria, dryer performance rate, thermal efficiency and annual operating cost, could be concluded to operate the dryer in the condition of maximum performance rate. The condition in general is identical to the lowest operation cost for a given annual operating hour.

  • PDF

A Study on the Spatial Typology and Size of Health Examination Center Depending on the Operating System (건강검진센터 운영방식에 따른 공간 유형과 규모에 관한 연구)

  • Son, Jihye;Cho, Junyoung;Kim, Uihyeon;Kim, Hyeonjeong;Yang, Naewon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.3
    • /
    • pp.17-26
    • /
    • 2022
  • Purpose: The purpose of this study is to classify space types according to the operating system of health examination centers and compare and analyze their sizes. Methods: Seven examination centers under the K Medical Research Institute with the same operating system and similar examination types and functional spaces are the subject of the investigation. Research is conducted through field investigation, user surveys, and drawing analysis. Results: The operating method of the health examination center can be largely divided into the function dispersed type and the function central type. The function dispersed type was planned as a vertical type, and the function central type was planned as a horizontal type. In the case of the function dispersed type, since the examinees move vertically to use the endoscope center and special examination center, the efficiency of the vertical movement must be considered when planning the function dispersed type of facility. The function dispersed type plans to increase work and manpower efficiency by arranging the areas used at the start and end of the examination. Because the function central type horizontally arranges related functions by area, it should be planned in a structure that makes it easy for examinees to find their way. Implications: Through this study, it is judged that it is possible to suggest architectural planning considerations that vary depending on the operation system of the examination center.

Introduce and application of the angular velocity sensing type of wheel flange lubricator for the railways in KOREA (국내 철도차량용 각속도 감지식 도유기의 적용 및 소개)

  • La, Won-Ki;Yang, Bang-Sub;Lee, Won-Sang;Chang, Dae-Sung
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.958-962
    • /
    • 2010
  • Most of operating railways in domestic, it is used to be Wheel flange lubricator system applied liquid spray type. Wheel flange lubricator are reduced the abrasion of wheel flange through spraying in accordance with operating on the curve or operating function of time base and/or distance base. this paper is written to introduce and study the efficiency for the angular velocity sensing type of lubricant systems.

  • PDF

The Separation Performance of Disc Plate and Frame Type Reverse Osmosis Modules (원판틀형 역삼투 모듈의 투과성능 비교)

  • 박민수;배성렬;정건용
    • Membrane Journal
    • /
    • v.7 no.2
    • /
    • pp.75-83
    • /
    • 1997
  • The disc plate and frame type modules for reverse osmosis were developed using three different types of baffles: linear (Type 1), curved (Type 2) and parallel shapes (Type 3). Separation performance tests were carried out for the modules using NaCl and sucrose solutions under the various concentrations and operating pressures. The permeation flux and solute rejection ratio for Type 3 module were the highest within operating pressure (35bar) and flow rate (6 l/min). The flux improvement ratio of Type 2 or 3 to Type 1 for NaCl solution decreased as operating pressure increased: flux improvement ratios of Type 3 for 1wt% of NaCl solution were about 100 and 10% at 10 and 35bar, respectively. However, the flux improvement ratio for sucrose solutions varied with the operating pressure and concentration. The permeation flux for Type 3 depended on the flow rate linearly, which is higher than that of turbulent flow region in the smooth channel.

  • PDF

Object-Based Operating System (OBJECT에 의한 운영체제의 구성에 대한 연구)

  • 이창수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.8 no.1
    • /
    • pp.23-29
    • /
    • 1983
  • This paper describes object-based operating system to suppeor relability and abstract data type. For reliability, all objects should be accessed through access rights in capability, and the protection domain is provided for all program modules such that efficient domain switching can be achieved. For abstract data type, type manager is provided.

  • PDF

Drive Characteristics of Outer-rotor Type SRM Considering Dual Operating Modes (이중운전조건을 고려한 외전형 SRM의 구동특성)

  • Ahn, Jin-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.7
    • /
    • pp.903-909
    • /
    • 2014
  • As a direct drive type washing machine requires two operating modes, washing and spinning modes, a design of the motor with high efficiency in each mode is not applicable to a conventional procedure. To achieve the requirements, a multi-pole outer rotor type switched reluctance motors are considered. To select a suitable motor type for the application, a static toque is compared based on the FEM analysis. The selected type is obtained for high and wide toque than other types of the motor. Further, the pole shape and arc are optimized to meet the required torque and torque ripple. To verify the proposed structure, the prototype is designed and manufactured. And the simulation and experimental results verify the validity of the proposed structure.

Dynamic Behavior of Rotating Shaft System Corresponding to Operating Modes (운전모드에 따른 회전축계의 동적거동)

  • Kim, Sang-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.9
    • /
    • pp.2744-2751
    • /
    • 1996
  • In case of limited power supply, a rotating shaft system may not reach its operating speed that is greater than its critical speed, but the speed oscillates with small ampllitude near critical speed. As a result, it is considered that the operating mode plays an important role in the smooth start of machines. In order to investigate the dynamic behaviors of the rotating shaft system at the beginning stage, one has derived the equations of motion whose degrees of freedom is three, two translations and one rotation. The simultaneous differential equations are numerically solved by using runge-Kutta method, and thus the small time step length could be required corresponding to the stability of solution. Three types of operating modes dependent upon the driving torque rate have been numerically investigated according to the maximum displacement of shaft center. The first type of relation is linear, the second type is composed of two linear curves recommended by machine manufacturer, and the last one is the proposed torque curve reflecting the frequency response curve of one degree of freedom system. For the second type of modes, it is found that the optimal range of intermediate speed to the critical speed lies between 0.8 and 0.9. In addition to that, the maximum displacement can be reduced more if the third type of mode is utilized.

A Study on the Area Composition of the Operating Unit After Remodeling (수술부 리모델링을 통한 공간구성 변화에 관한 연구)

  • Kim, Khilchae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.4
    • /
    • pp.57-67
    • /
    • 2023
  • Purpose: Recently, the operating unit remodeling compititon has been increasing rapidly in Korea, but there are no design infomation for spatial planning of sterile supply storage. Therefore, the propose of this study is to present area composition of the operating unit after remodeling. Methods: For literature review, the 6 studies and guidelines of operating unit(guidelines in the U.S, Australia, UK and Korea and 2 studies in Korea) conducted surveys and analysis. Room and space composition and zone of operating unit are redefined for this study. For obtaining area, to conduct masuring and calcuating of document of operating unit before and after remodeling in 3 cases. There are some patterns of plan in operaing unit by sterile supply storage. This study derived data for attributes of area composition of sterile supply storage. Results: The results of this study are as follows: First, Reviewing previous studies and Guidelines, for this study the suggested model was 5 zones(Operating zone, Support zone, Patient zone, Staff zone, Circulation zone) and redefined each room and space. Second, For infection control, sterile supply storage was provided to directly accessible to the operating room. Third, According to ralation of operting room and sterile supply storage, there are two types : 'double loaded type' and 'single loded type'. Sterile supply storage shall increase area of ciculation zone. Implications: This study can be used as primary data on remodeling of operating unit. In addition, it suggests that for infect control sterile supply storage is functional area.