• Title/Summary/Keyword: Operating temperature range

Search Result 548, Processing Time 0.036 seconds

Analysis of freeze-thaw conditions of soil using surface state factor and synthetic aperture radar (지표상태인자와 영상레이더를 활용한 토양의 동결-융해 상태 분석)

  • Yonggwan Lee;Jeehun Chung;Wonjin Jang;Wonjin Kim;Seongjoon Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.53-53
    • /
    • 2023
  • 본 연구에서는 토양의 동결-융해 상태 구분을 위해 영상레이더(Synthetic Aperture Radar) 자료를 활용해 지표상태인자(Surface State Factor, SSF)를 산정하고, 관측 토양수분 자료 및 지표면 온도(Land Surface Temperature, LST) 자료와의 비교를 통해 SSF의 정확도를 분석하였다. SSF 산정은 용담댐 유역을 포함한 인근 40×50 km2의 영역(N35°35'~36°00', E127°20'~127°45')에 대한 9개의 토양수분 관측지점(계북, 천천, 상전, 안천, 부귀, 주천, 장수읍, 진안읍, 무주읍)을 대상으로 연구를 수행하였으며, 이를 위해 2015년부터 2019년까지의 해당 지점의 토양수분 관측자료와 Sentinel-1A Interferometric Wide swath (IW) 모드의 Ground Range Detected (GRD) product를 구축하여 활용하였다. SSF 자료의 정확도 분석을 위한 토양수분 관측지점에 대한 LST 자료는 인근 7개 기상관측소 지점(전주, 금산, 임실, 남원, 장수, 함양군, 거창)의 관측자료로부터 역거리가중법을 통해 산정하였다. Receiver Operating Characteristic (ROC) 분석을 통한 겨울철(12-2월)의 SSF 산정 정확도를 평가한 결과, 지표면 온도 자료와의 평균 정확도는 0.75(0.48-0.87)로 나타났다. 그러나, 지표면 온도가 0℃ 이상일 때 SSF가 동결 상태로 나타나는 오차가 관측되었으며, 이는 여름철 후방산란계수의 평균값과 겨울철 후방산란계수의 평균값을 통해 산정하는 SSF 산정 수식의 특성 때문으로 이 값의 조정을 통해 오차를 개선할 수 있음을 보였다.

  • PDF

Hydrogen Refueling Stations Improving Safety and Economic Feasibility (안전성과 경제성이 개선된 수소충전소)

  • YunSil Huh;DongHoon Lee;Yongjin Chung;Yongchai Kwon
    • Korean Chemical Engineering Research
    • /
    • v.61 no.4
    • /
    • pp.611-618
    • /
    • 2023
  • The purpose of the refueling protocol and the contents of SAE J2601, which is used as the basis for hydrogen vehicles refueling around the world, were investigated, and research contents related to domestic protocols were also investigated. In addition, the components of the hydrogen refueling performance evaluation device developed in Korea and the method for evaluating the performance and safety of hydrogen refueling stations were reviewed. And, the result were analyzed by applying it to the hydrogen refueling stations currently operating in Korea. In addition, an economic feasibility analysis was conducted using data collected from domestic hydrogen refueling stations. In order to secure the safety and economy of a hydrogen refueling station, the protocol must be satisfied, and in order to satisfy the protocol, it is necessary to evaluate whether the refueling temperature, refueling pressure, and refueling flow are controlled within a safe range.

System Analysis and Power Amplifier Design for ILS Localizer (ILS 로컬라이저 시스템 분석 및 전력증폭기 설계)

  • Su kyung Kim;Kyung Heon Koo
    • Journal of Advanced Navigation Technology
    • /
    • v.28 no.1
    • /
    • pp.116-122
    • /
    • 2024
  • In this paper, course structure and course width were studied among the main performances of the system to derive the required performance of the modulation index, output power, and phase change specifications of the instrument landing system (ILS) localizer power amplifier. To satisfy the course structure's deviation standard (± 5 uA), the difference in depth of modulation (DDM) deviation standard of the carrier with sideband (CSB) amplifier was standardized to ± 1 uA(0.001 DDM). CSB 30 W power amplifier was designed, and through the modulation compensation circuit, sum in depth of modulation (SDM) is 40% ± 0.1% and DDM is ± 0.0005 DDM in the operating output range(45 dBm ~ 35 dBm). In addition, the course width and displacement sensitivity specifications were analyzed through simulation, and the ± 0.1° change applied during comissioning inspection, which is the most stringent standard, was applied. The output variation of the suppressed with sideband only ( SBO) amplifier was ± 2 mW or less, The phase was standardized to within ± 3 ° and the characteristics were satisfied. By applying a compensation circuit according to output power and temperature, stable modulation index, output, and phase characteristics were obtained.

Characterization and annealing effect of tantalum oxide thin film by thermal chemical (열CVD방법으로 증착시킨 탄탈륨 산화박막의 특성평가와 열처리 효과)

  • Nam, Gap-Jin;Park, Sang-Gyu;Lee, Yeong-Baek;Hong, Jae-Hwa
    • Korean Journal of Materials Research
    • /
    • v.5 no.1
    • /
    • pp.42-54
    • /
    • 1995
  • $Ta_2O_5$ thin film IS a promising material for the high dielectrics of ULSI DRAM. In this study, $Ta_2O_5$ thin film was grown on p-type( 100) Si wafer by thermal metal organic chemical vapo deposition ( MCCVD) method and the effect of operating varialbles including substrate temperature( $T_s$), bubbler temperature( $T_ \sigma$), reactor pressure( P ) was investigated in detail. $Ta_2O_5$ thin film were analyzed by SEM, XRD, XPS, FT-IR, AES, TEM and AFM. In addition, the effect of various anneal methods was examined and compared. Anneal methods were furnace annealing( FA) and rapid thermal annealing( RTA) in $N_{2}$ or $O_{2}$ ambients. Growth rate was evidently classified into two different regimes. : (1) surface reaction rate-limited reglme in the range of $T_s$=300 ~ $400 ^{\circ}C$ and (2: mass transport-limited regime in the range of $T_s$=400 ~ $450^{\circ}C$.It was found that the effective activation energies were 18.46kcal/mol and 1.9kcal/mol, respectively. As the bubbler temperature increases, the growth rate became maximum at $T_ \sigma$=$140^{\circ}C$. With increasing pressure, the growth rate became maximum at P=3torr but the refractive index which is close to the bulk value of 2.1 was obtained in the range of 0.1 ~ 1 torr. Good step coverage of 85. 71% was obtained at $T_s$=$400 ^{\circ}C$ and sticking coefficient was 0.06 by comparison with Monte Carlo simulation result. From the results of AES, FT-IR and E M , the degree of SiO, formation at the interface between Si and TazO, was larger in the order of FA-$O_{2}$ > RTA-$O_{2}$, FA-$N_{2}$ > RTA-$N_{2}$. However, the $N_{2}$ ambient annealing resulted in more severe Weficiency in the $Ta_2O_5$ thin film than the TEX>$O_{2}$ ambient.

  • PDF

Basic Analysis of Heat and Mass Transfer Characteristics of Tubular Membrane Humidifier for Proton Exchange Membrane Fuel Cell (이온교환막 연료전지용 원통형 막 가습기의 열 및 물질전달특성 기초 연구)

  • Bae, Ho-June;Ahn, Kook-Young;Lee, Young-Duk;Kang, Sang-Kyu;Yu, Sang-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.5
    • /
    • pp.473-480
    • /
    • 2011
  • The proton exchange membrane (PEM) fuel cell system is critically dependent on the humidity, which should be properly maintained over the entire operating range. A membrane humidifier is used for the water management in the PEMFC because of the membrane humidifier's reliable performance and zero parasitic power loss. In the PEMFC system, the membrane humidifier is required to provide appropriate humidity for the design point of the fuel cell. Although the performance of the fuel cell depends on the performance of the humidifier, few studies have provided a systematic analysis of the humidifier. We carry out an experimental analysis of the membrane humidifier using a vapor condensation bottle. The dry air pressure, water flow temperature, and air flow rate were chosen as the operating parameters. The results show that the time constant for the dynamic response of the membrane humidifier is relatively short, but additional analysis should be carried out.

A Practice-Oriented Study on Sawdust File Filteration Composting of High Moisture Pig Slurry (고수분 돈분슬러리의 톱밥여과 퇴비화 현장적용 연구)

  • Ryoo, J.W.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.2
    • /
    • pp.129-138
    • /
    • 2008
  • This study was carried out to investigate the operating characteristics, water balance and chemical properties of compost during the composting with pig slurry on-farm trial. The composting plant with sawdust pile filteration was done in a forced aeration inside a house and equipped with a turning machine moving on a rails. The composting pit was 4.6m wide, 53m long and the maximum height was 2m. A field scale aerobic composting facility was tested the composting efficiency of high moisture pig slurry. The sawdust materials remained 6 months. Pig slurry was added to compost pile every other day during 6 months run. The temperature in compost pile and compost house, and input and output of moisture were measured during composting process. The result are summarized as follows; 1. The temperature of compost was varied in range of at $22.4^{\circ}C{\sim}71.1^{\circ}C$. After turning, the composting temperature decreased to $50^{\circ}C{\sim}36^{\circ}C$ during $3{\sim}5$ hours, and then raised to $64.5^{\circ}C$ 2. The temperature of compost house was maintained $20^{\circ}C{\sim}30^{\circ}C$, and relative humidity was varied in range of $50{\sim}99%$. 3. BOD, CODcr and SS of leachate water was reduced 89.5%, 81.2%, 97.5%, respectively. 4. The content of heavy metal in the final compost was lower those of Korea standards. 5. The amount of effluent was 10.2%. Total evaporation during composting Period were 74.8%. The amount of slurry per $1m^3$ sawdust was $3.16m^3$ without treatment of effluent output.

  • PDF

Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility (다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구)

  • Kim, Tae-Han;Choi, Boo-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.5
    • /
    • pp.80-88
    • /
    • 2020
  • With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM10, PM2.5, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM10) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM2.5) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM10, PM2.5) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.

Turbine Efficiency Analysis of Steady Flow in a Twin Scroll Turbocharger (트윈 스크롤 터보과급기에서 정상유동의 터빈 효율 분석)

  • Chung, Jin-Eun;Jeon, Se-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.765-770
    • /
    • 2020
  • The turbochargers used widely in diesel and gasoline engines are effective devices to reduce fuel consumption and emissions. In this study, the isentropic turbine efficiency of the steady flow in a twin-scroll turbocharger for the passenger vehicle gasoline engine was analyzed. The cold gas test bench was designed and made. The pressure and temperature of the inlet and exit of the turbine were measured at 60,000, 70,000, 90,000, and 100,000rpm under the steady-state flow. The isentropic turbine efficiency was calculated. The efficiency was the range of 0.53 to 0.57. The BSR and expansion ratio were changed from 0.71 to 0.84 and from 1.24 to 1.72, respectively. The isentropic turbine efficiency decreased with increasing BSR and expansion ratio. The operation of only scroll A or B was compared with that of the twin-scroll turbine. The isentropic efficiency of using only scroll B was higher than those of only scroll A at 60,000rpm. The isentropic efficiency of using only scroll A was higher than those of only scroll B at 100,000rpm. Therefore, the twin-scroll turbine used in this study is operating effectively in the wide speed range.

Optical Current Sensors with Improved Reliability using an Integrated-Optic Reflective Interferometer (반사형 간섭계를 이용하여 신뢰성을 향상시킨 광전류센서)

  • Kim, Sung-Moon;Chu, Woo-Sung;Oh, Min-Cheol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.5
    • /
    • pp.17-23
    • /
    • 2017
  • Optical current sensors are suitable for operation in high voltage and high current environments such as power plants due to they are not affected by electromagnetic interference and have excellent insulation characteristics. However, as they operate in a harsh environment such as large temperature fluctuation and mechanical vibration, high reliability of the sensor is required. Therefore, many groups have been working on enhancing the reliability. In this work, an integrated optical current sensor incorporating polarization-rotated reflection interferometer is proposed. By integrating various optical components on a single chip, the sensor exhibits enhanced stability as well as the solution for low-cost optical sensors. Using this, we performed the characterization for the actual field application. By using a large power source, the current of 0.3 kA~36 kA was applied to the photosensor and the linear operation characteristics were observed. The error of the sensor was within $0{\pm}.5%$. Even when operating for a long time, the error range of the sensor was kept within $0{\pm}.5%$. In addition, the measurement of the frequency response over the range of 60 Hz to 10 kHz has confirmed that the 3-dB frequency band of the proposed OCT is well over 10 kHz.

Extraction of Pigment from Sea Mustard ( Undaiia pinnatinda) using Supercritical Carbon Dioxide and Entrainer (초임계 이산화탄소와 보조용매를 이용한 미역으로부터 색소 추출)

  • HONG Seok-Ki;CHUN Byung-Soo;PARK Sun-Young
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.34 no.3
    • /
    • pp.213-217
    • /
    • 2001
  • In order to develop a new separation technology, supercritical fluid extraction process was used to produce high purity pigments and fatty acids from seaweed (Undaria pinnatifida). Supercritical carbon dioxide was used as a solvent and ethanol as an entrainer. The sample was treated by a frozen drier and experiments were conducted with a semi-batch flow system at various operating conditions (pressure range, $10.3\~17.2$ MPa; temperature range, $30\~45^{\circ}C$: particle size, $500\~1,000{\mu}m$ extraction time, 60 min). Characteristics of the recovered pigment (chlorophyll a) and fatty acids were determined by UV-spectrophotometry and gas chromatography, respectively. The highest extraction efficiency for fatty acids and pigments was achieved at 12.4 MPa, $35^{\circ}C$, $500{\mu}m$of seaweed size.

  • PDF