• Title/Summary/Keyword: Operating status

Search Result 967, Processing Time 0.025 seconds

Development of Operating Technology for AGV System (AGV 시스템의 운영기술 개발)

  • Song, Jun-Yeop;Lee, Seung-U;Lee, Hyeon-Yong
    • 연구논문집
    • /
    • s.22
    • /
    • pp.27-38
    • /
    • 1992
  • We deals with stationary layout control system of AGV. It is a intelligent control system to he wholly charged control PC a layout information and guided command and to be controlled a vehicle driving, steering, safety of natural functions of AGV. Fieldbus concentrator of stationary layout control system serves control command from control PC and status information of AGV. Telegram software monitors transmitted command and status information through IR(JnfraRed) modem. Especially it is possible to easily network to use not an exclusive controller of AGV but personal computer(PC) when communicate and interface a different kind of controller.

  • PDF

Analysis Method of CTC Status Monitoring (CTC 상태감시 데이터 해석기법)

  • 최규형;정의진;강규현
    • Proceedings of the KSR Conference
    • /
    • 1999.11a
    • /
    • pp.273-279
    • /
    • 1999
  • The main purpose of this study is to develope a Simulator for Central Traffic Controller(CTC) which can check the operating status of CTC and support tile maintenance procedure. The simulator supervise the CTC processor units and the data transmission between the CTC modules and the railway station equipments to define the validity of system functions and notify whether the eqipments are good or not. With the help of the simulator we could detect the error of CTC equipments easily. repair the faults efficiently. and improve tile reliability of CTC system.

  • PDF

A study on the implementation of a CATV status monitoring system using HDLC protocol (HDLC 프로토콜을 채용한 CATV 망감시 시스템 구현에 관한 연구)

  • 김내진;김진태;박인갑
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.10
    • /
    • pp.10-20
    • /
    • 1994
  • This paper presents a CATV SMS (Status Monitoring System) using HDLC (High Level Data Link Contorl) protocol and the system implementation.The system specifications were derived from the analysis of technical status and requirement of the domestic CATV industry. For the interoperability with a global network management system in the future, HDLC protocol was adopted in the system. The system performance was improved by using the communication controller chip and the large data buffer. For reducting the communication problems induced by accumulated noise in up-stream data channels, the system was designed that the different communication channel can be assigned to each proper mass of terminal. The operating software was designed with menu driven user interface and have various functions for the convenience of users. The test result of the implemented system at the experimental network showed good performance and suitability for a coaxial CATV Status Monitoring System.

  • PDF

Physiological Status Assessment of Locomotive Engineer During Train Operation

  • Song, Yong-Soo;Baek, Jong-Hyen;Hwang, Do-Sik;Lee, Jeong-Whan;Lee, Young-Jae;Park, Hee-Jung;Choi, Ju-Hyeon;Yang, Heui-Kyung
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.324-333
    • /
    • 2014
  • In this study, physiological status of locomotive engineers were measured through EEG, ECG, EDA, PPG and respiration signals from 6 subjects to evaluate their arousal status during train operating. Existence of tunnels and mechanical vibration of train using 3-axes acceleration sensors were recorded simultaneously and were correlated with operator's physiological status. As the result of the analyzed subjects' physiological signals, mean SCR was increased in the section where more body movement is required. The RR interval was decreased before and after train stop due to the higher level of mental tension. The intensity of beta wave of EEG was found to be higher before and after train stop and tunnel section due to the increased mental arousal and tension. Therefore, it is expected that the outcomes of the physiological signals explored in this study can be utilized as the quantitative assessment methods for the arousal status to be used for sleepiness prevention system for vehicles operators which can greatly contribute to public transportation system safety.

Modeling of Left Ventricular Assist Device and Suction Detection Using Fuzzy Subtractive Clustering Method (퍼지 subtractive 클러스터링 기법을 이용한 좌심실보조장치 모델링 및 흡입현상 검출)

  • Park, Seung-Kyu;Choi, Seong-Jin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.4
    • /
    • pp.500-506
    • /
    • 2012
  • A method to model left ventricular assist device (LVAD) and detect suction occurrence for safe LVAD operation is presented. An axial flow blood pump as a LVAD has been used to assist patient with heart problems. While an axial flow blood pump, a kind of a non-pulsatile pump, has relative advantages of small size and efficiency compared to pulsatile devices, it has a difficulty in determining a safe pump operating condition. It can show different pump operating statuses such as a normal status and a suction status whether suction occurs in left ventricle or not. A fuzzy subtractive clustering method is used to determine a model of the axial flow blood pump with this pump operating characteristic and the developed pump model can provide blood flow estimates before and after suction occurrence in left ventricle. Also, a fuzzy subtractive clustering method is utilized to develop a suction detection model which can identify whether suction occurs in left ventricle or not.

A Study on Data Linkage Between Public Data Portals and Individual Portals (공공데이터 포털과 개별 포털 간의 데이터 연계방안 연구)

  • Jin Ho, Park;Sang Woo, Han
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.33 no.4
    • /
    • pp.249-269
    • /
    • 2022
  • The Public Data Portal(data.go.kr) is a gateway for searching and using public data in South Korea. In 2021, the Ministry of Public Administration and Security established individual portal maintenance plans. Individual portals refer to portals built by public institutions in Korea other than the public data portal. According to the maintenance plan, the Korea Intelligence Information Society, the operator of the public data portal, needs to establish operating and data integration plans to link the public data portal and individual portals. In this study, we investigated the current operating status and data integration methods of the public data portal in South Korea, the United States, the United Kingdom, and France, and proposed that the adoption of a top-down approach is efficient when integrating data. In addition, we divided the specific procedures that should be pursued when integrating data into five stages: determination of data integration standard methods, analysis of metadata status, expansion of operating infrastructure, confirmation of data import, and launch of services.

Analysis of the Principle and Operation Characteristics of an (Igc-Free ELB) Operated by an Active Component (유효성분 동작형 누전차단기(Igc Free ELB)의 원리 및 동작 특성 해석)

  • Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.456-461
    • /
    • 2010
  • This study compares the criteria of earth leakage breakers (ELB) and analyzes the characteristics of an Igc-free ELB operated by an active component which is not misoperated by capacitive current. Even for the same ELB, the earth leakage current flowing through the human body is estimated to be differ greatly depending on the power source, voltage, location and status of contact, contact time duration, etc. Earth leakage breakers are classified based on the rated voltage, rated sensing current, rated operating time etc. Mounting and demounting of the existing equipment can be performed easily since an $I_{gc}$-free ELB is manufactured with the same structure as a conventional ELB. The rated operating current of a conventional and an $I_{gc}$-free ELB is 30mA, the sensing current is 25mA and the rated non-operating current is 15mA. In the analysis of non-operating current characteristics, the rated non-operating current of 15mA was satisfied up to a 20mA charging current in the conventional ELB, but does not satisfy the rated non-operating current as it operates when the resistive leakage current is lower than 15mA for a charging current exceeding 20mA. Also, the ELB is misoperated without a resistive leakage current when the charging current exceeded 25mA. However, the newly developed $I_{gc}$-free ELB satisfied the rated non-operating current even when the charging current was 60mA. Also, in comparison to the interrupting characteristics, it was confirmed that the charging current satisfying the rated non-operating current of the $I_{gc}$-free ELB was three times higher than that of the conventional ELB.

Factors Affecting on the Level of Practice on Nosocomial Infection Management among Operating Room Nurses (수술실 간호사의 병원감염관리 실천정도에 영향을 미치는 요인)

  • Her, Sun;Kim, In-Sook;Kim, Kye-Ha
    • Korean Journal of Adult Nursing
    • /
    • v.20 no.3
    • /
    • pp.375-385
    • /
    • 2008
  • Purpose: This study is to identify factors affecting on the level of practice on nosocomial infection management of operating room nurses. Methods: The subjects of this study were 155 nurses who worked in operating rooms of six medical centers in located Gwangju and Chonanam area. Data were collected during October, 2006 by the questionnaire including a total of 124 questions. Data collected were analysed with use of SPSS 12.0 program. Results: There was a significant difference of the level of practice by marital status(t=3.957, p=.048), education level(F=3.691, p=.027), position(F=6.588, p=.002), type of hospital(t=4.857, p=.029), number of nurse(F=4.243, p=.007), education about nosocomial infection management(F=3.069, p=.030), management council(t=6.397, p=.012) and management manual(t=6.961, p=.009). There were significant correlations between knowledge and practice (r=.389, p=.000), and between awareness and practice(r=.389, p=.000). Knowledge on nosocomial infection management, awareness of hands washing and positions were affecting factors on the level of practice. Conclusion: This study suggests that knowledge and awareness on nosocomial infection prevention and management of operating room nurses should be improved through consistent education. and support of administrator's of hospitals is needed.

  • PDF

A Study on the Location and Area Composition of the Operation Department in Regional Public Hospitals - Focused on Net Floor Area (지방의료원 수술부 배치 및 규모에 관한 연구 - 순면적을 중심으로)

  • Yun, Woo Yong;Chai, Choul Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.4
    • /
    • pp.93-104
    • /
    • 2019
  • Purpose: To establish the building guidelines and to analyze the function of Regional Public Hospitals, the survey was conducted primarily on the current status focusing on the location and relationship of the department, area composition ratio, area per bed, and area per operating room. Methods: The research methods of this paper are as follows. 1) A literature survey on the function of the operating and related departments, 2) A drawing analysis for spatial composition and net area calculation. Results: The area of the Operation Department in the Regional Public Hospitals with 200 to 300 beds are as follows. Area ratio: 3.35%, area per Bed: 2.53㎡/bed, the number of beds per operating room: 64.37bed, area per operating room: 146.46㎡/n, area per operating room by plan type: integration corridor 133.84㎡/n, separation corridor 184.82㎡/n. Implications: This paper analyzed data on the current state of Operation Departments for setting up the function and role for the Regional Public Hospital. In the future, it is also required to provide size that takes into account user behavior and the user's psychological aspect in order to suggest appropriate area.

Competency of Nursing Performance and Job Satisfaction of Operating Room Nurse by Type of Nurse Staffing (간호인력배치유형에 따른 수술실 간호사의 업무수행능력 및 직무만족)

  • Ahn, Young-Mi;Park, Chai-Soon
    • Women's Health Nursing
    • /
    • v.11 no.2
    • /
    • pp.169-175
    • /
    • 2005
  • Purpose: This study was designed to investigate the relationships of the types of nurse staffing, the competency of nursing performance and job satisfaction by analyzing the types of nurse staffing in operating room. Method: The subjects were 472 nurses who work in operating room. The instruments used in this study were three tools: competency of nursing performance, job satisfaction and type of nurse staffing. Result: Type 4 was most in the type of nurse staffing of the subjects. According to the type of nurse staffing, the competency of nursing performance was significantly different. There was significant difference in the competency of nursing performance according to age, marital status, bachelor, employ, position, and career, and job satisfaction according to age, position, and career. In opinion about the ideal type of nurse staffing, type 2 was most regardless of career. Conclusion: Type 4 which has lower competency of nursing performance was adopted in many hospitals now but, type 2 which has highest competency of nursing performance was selected by many nurses as the best one. So, it should be considered the type of nurse staffing of in operating room and change it.

  • PDF