• Title/Summary/Keyword: Operating range

Search Result 2,435, Processing Time 0.04 seconds

A Study on the Dynamic Analysis of Micro-Grid System (Micro-Grid 시스템의 동특성 해석에 관한 기초 연구)

  • Son, Kwang-M.;Lee, Kye-B.;Jeon, In-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.543-544
    • /
    • 2007
  • Micro-grid consists of micro-sources which adopt environmentally friendly and reliable power sources with independent real and reactive power control capability for providing premium power quality. This paper presents dynamic modeling and the stable operating range of the micro-grid system varying the parameters of the micro-sources. Case study results show the parameters affecting the stability of the micro-grid and the stable operating range of the micro-sources.

  • PDF

CHOPPING AND SWITCHING EXCITATION OF A SWITCHED RELUCTANCE MOTOR (스윗치드 리럭탄스 전동기의 쵸핑여자 및 스윗칭여자특성)

  • Kwon, Y.A.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1013-1015
    • /
    • 1993
  • The switched reluctance motor is excited and controlled by two kinds of excitation; chopped excitation and switched excitation. The former produces additional inverter losses, and onuses drive control to be complicated. The limit of chopping frequency reduces a range of operating speed and torque. This paper examines chopped excitation and switched excitation in a nonlinear switched reluctance motor. The result indicates switched excitation can be satisfactorily applied to the full operating range, and furthermore indicates the improved efficiency.

  • PDF

Using a Stretch Sensor About of Squat Ankle Range of Motion Check Socks -Focusing on Men in Their Late 20s- (스트레치 센서를 이용한 스쿼트 시 발목 가동범위 체크 센서 양말에 관하여 -20대 후반 남성을 중심으로-)

  • Song, Kwanwoo;Park, Jinhee;Kim, Jooyong
    • Journal of Fashion Business
    • /
    • v.26 no.2
    • /
    • pp.129-142
    • /
    • 2022
  • The purpose of this study is to develop socks to check the range of ankle movement during squats for men in their late 20s. Sensors of 6, 8, and 12 mm were selected, and each sample was impregnated 1 to 3 times. It was prepared using a CNT dispersion, and the GF value was measured using UTM. Among them, the sample with 2 impregnation showed the best GF value. As a result of applying each sample to the socks, the 12 mm sensor was wider than the area of the Achilles tendon, resulting in noise, and the 8 mm sensor was higher than the tensile strength of the socks, resulting in a decrease in the graph. Therefore, testing was performed using a 6 mm sensor. In order to determine the effectiveness of the sensor, the normal operating range was checked through squats, and significant changes were confirmed when the operating range was checked again through squats by performing operations that can increase the operating range through Gastrocnemius, Soleus stretching, and low lunge. Using the results of this study, it is expected that the average value of the ankle movement range of the user is checked prevent injury, to be provided as basic data for the production of shoe products and the promotion of physical health.

A 9-bit ADC with a Wide-Range Sample-and-Hold Amplifier

  • Lim, Jin-Up;Cho, Young-Joo;Choi, Joong-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.4 no.4
    • /
    • pp.280-285
    • /
    • 2004
  • In this paper, a 9-bit analog-to-digital converter (ADC) is designed for optical disk drive (ODD) servo applications. In the ADC, the circuit technique to increase the operating range of the sample-and-hold amplifier is proposed, which can process the wide-varying input common-mode range. The algorithmic ADC structure is chosen so that the area can be significantly reduced, which is suitable for SoC integration. The ADC is fabricated in a 0.18-$\mu\textrm{m} $ CMOS 1P5M technology. Measurement results of the ADC show that SNDR is 51.5dB for the sampling rate of 6.5MS/s. The power dissipation is 36.3mW for a single supply voltage of 3.3V.

Advanced Field Weakening Control for Squirrel-Cage Induction Motor in Wide Range of DC-Link Voltage Conditions

  • Son, Yung-Deug;Jung, Jun-Hyung;Kim, Jang-Mok
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.665-673
    • /
    • 2017
  • This paper proposes a field weakening control method for operating an induction motor with a variable DC input voltage condition. In the variable DC voltage condition such as a battery, the field weakening method are required for the maximum output power. The conventional field weakening control methods can be used for operating the induction motor over the rated speed in a constant DC-link voltage condition. However, the conventional methods for operating the motor with the variable DC voltage is not suitable for the maximum output power. To overcome this problem, this paper proposes the optimized field weakening control method to extend the operating range of the induction motor with a rated power in a limited thermal and a wide DC input voltage conditions. The optimized d-axis and q-axis current equations are derived according to the field weakening region I and II to extend the operating region. The experimental results are presented to verify the effectiveness of the proposed method.

Solid Circulation Characteristics of Two Oxygen Carriers for Chemical Looping Combustion System (케미컬루핑 연소시스템을 위한 두 가지 산소전달입자들의 고체순환 특성)

  • RYU, HO-JUNG;LEE, DOYEON;NAM, HYUNGSEOK;JO, SUNG-HO;BAEK, JEOM-IN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.4
    • /
    • pp.393-400
    • /
    • 2018
  • To confirm the operating range of two oxygen carriers for chemical looping combustion system, the effects of operating variables on solid circulation rate were measured and discussed using a two-interconnected circulating fluidized bed system at ambient temperature and pressure. Moreover, suitable operating ranges to avoid choking of the fast fluidized bed (air reactor) were confirmed for two oxygen carriers. A continuous long-term operation of steady-state solid circulation more than 24 hours was also demonstrated within the operating windows. Finally we could confirm that those two oxygen carriers are suitable for chemical looping combustion system with high solid circulation rate and smooth solid circulation.

Sensitivity Analysis of Amino Acids in Simulated Moving Bed Chromatography

  • Lee, Ju-Weon;Lee, Chong-Ho;Koo, Yoon-Mo
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.2
    • /
    • pp.110-115
    • /
    • 2006
  • We conducted a sensitivity analysis of the simulated moving bed (SMB) chromatography with the case model of the separation of two amino acids phenylalanine and tryptophan. We consider a four-zone SMB chromatography where the triangle theory is used to determine the operating conditions. Competitive Langmuir isotherm model was used to determine the adsorption isotherm. The finite difference method is used to solve nonlinear partial differential equation (PDE) systems numerically. We examined the effects of alterations in the operating conditions(feed-extract, feed-raffinate, eluent-extract, eluent-raffinate, recycle, and switching time) and the adsorption isotherm parameters (Langmuir isotherm parameters a and b) on SMB efficiency. The variation range of operating conditions and Langmuir isotherm a was between -50 and 50% of original value and the variation range of the Langmuir isotherm b was between $2.25^{-5}$ and $2.25^5$ times of original value.

Dynamic Analysis of Metal Transfer in Pulsed-GMAW (Pulsed-GMAW의 금속 이행 현상에 관한 동적 해석)

  • 최상균;유중돈;박상규
    • Journal of Welding and Joining
    • /
    • v.15 no.5
    • /
    • pp.84-91
    • /
    • 1997
  • The metal transfer phenomenon of the pulsed-GMAW is simulated by formulating the electromagnetic force incorporated with the Volume of Fluid algorithm. The free surface profiles, pressure and velocity distributions within the drop are computed numerically. Axial velocity and acceleration generated during peak current period are found to have a significant effect on drop detachment. Therefore, the accelerated inertia force becomes one of important factors affecting metal transfer in the pulsed-GMAW. When the pulse current parameters are selected properly, the molten drop is detached just after current pulse, and the operating range of the pulsing frequency increases with higher peak current and duty cycle. Calculated operating ranges show reasonably good agreements with the available experimental data.

  • PDF

Self-Oscillating Switching Technique for Current Source Parallel Resonant Induction Heating Systems

  • Namadmalan, Alireza;Moghani, Javad Shokrollahi
    • Journal of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.851-858
    • /
    • 2012
  • This paper presents resonant inverter tuning for current source parallel resonant induction heating systems based on a new self oscillating switching technique. The phase error is suppressed in a wide range of operating frequencies in comparison with Phase Locked Loop (PLL) techniques. The proposed switching method has the capability of tuning under fast changes in the resonant frequency. According to this switching method, a multi-frequency induction heating (IH) system is proposed by using a single inverter. In comparison with multi-level inverter based IH systems, the advantages of this technique are its simple structure, better transients and wide range of operating frequencies. A laboratory prototype was built with an operating frequency of 35 kHz to 55 kHz and 300 W of output power. The performance of the IH system shows the validity of the new switching technique.

Distributed Control of the Arago's Disc System with Gain Scheduler

  • Ibrahim, Lateef Onaadepo;Choi, Goon-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.3
    • /
    • pp.25-30
    • /
    • 2017
  • Arago's disk system consists of a speed controller of the DC motor (inner loop controller) and a position controller of the magnetic bar angle (main controller), which are implemented by the design of the PI and PID controller, respectively. First, we analyzed the nonlinear characteristics of the Arago disk system and found the operating point range of three locations as a result. In this paper, a gain scheduler method was applied to guarantee a constant control performance in the range of $0{\sim}130^{\circ}C$, and a structure to change the controller according to the control reference value based on the previously obtained operating points was experimentally implemented. The Distributed Control Systems (DCS) configuration using the Controller Area Network (CAN) was used to verify the proposed method by improving the operational efficiency of the entire experimental system. So, simplicity of the circuit and easy diagnosis were achieved through a single CAN bus communication.

  • PDF