복합전력계통 신뢰도평가의 확률론적 안전도 도입 (The Implementation of Probabilistic Security Analysis in Composite Power System Reliability)

  • 차준민;권세혁;김형철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권5호
    • /
    • pp.185-190
    • /
    • 2006
  • The security analysis relates to the ability of the electric systems to survive sudden disturbances such as electric short circuits or unanticipated loss of system elements. It is composed of both steady state and dynamic security analyses, which are not two separate issues but should be considered together. In steady state security analysis including voltage security analysis, the analysis checks that the system is operated within security limits by OPF (optimal power flow) after the transition of a new operating point. On the other hand, dynamic security analysis deals that the transition will lead to an acceptable operating condition. Transient stability, which is the ability of power systems to maintain synchronism when subjected to a large disturbance, is a principal component in dynamic security analysis. Usually any loss of synchronism will cause additional outages. They make the present steady state analysis of the post-contingency condition inadequate for unstable cases. This is the reason of the need for dynamics of systems. Probabilistic criterion can be used to recognize the probabilistic nature of system components and shows the possibility of system security. A comprehensive conceptual framework for probabilistic static and dynamic assessment is presented in this paper. The simulation results of the Western System Coordinating Council (WSCC) system compare an analytical method with Monte-Carlo simulation (MCS). Also, a case study of the extended IEEE Reliability Test System (RTS) shows the efficiency of this approach.

2단 변속기 적용 전기차의 구동 효율 향상을 위한 변속 제어 최적화 (Optimization of Shift Control to Improve Driving Efficiency of Battery Electric Vehicles with Two-speed Transmission)

  • 정택호;김영희
    • 한국분무공학회지
    • /
    • 제28권2호
    • /
    • pp.62-67
    • /
    • 2023
  • Recently, the global automobile industry is aiming for a transition from internal combustion locomotives to zero-emission vehicles. Electric vehicles powered by battery energy can operate at peak performance and improve fuel economy by applying multiple motors or multi-speed transmissions. In order to design a two-speed transmission, it is necessary to evaluate and analyze the application system and performance of electric vehicles. In this study, control performance optimization of a twostage battery electric vehicle equipped with an AMT-based automatic transmission was performed and performance according to control pattern changes was analyzed. In order to improve the operating efficiency of the motor, the shift control that sets the optimal operating point according to the vehicle speed and required torque was derived from the motor efficiency map. The performance of battery energy consumption and transmission loss energy according to the hysteresis interval was analyzed and optimized. The hysteresis interval applied to the optimal shift map acted as a factor in reducing the frequency and loss of shifts. It has been shown that keeping the hysteresis interval at about 4 km/h can reduce energy consumption while reducing the number of shifts.

대도시 내 BTB HVDC 투입 시 운전점 결정 방안 (Determination of BTB HVDC Operating Point in Metropolitan area)

  • 이재형;윤민한;한창희;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.331-332
    • /
    • 2015
  • Since $20^{th}$ century, along with the rapid industrial advancement, the concentrated urban development in specific large cities have made people migrate to those cities, thus causing problems in the power system stability. In case of Korea, more than 40% of the power system demand comes from the consumers in Seoul Metropolitan area and the rate is expected to increase. With the continuous increase of power demand, in order to meet the demand for system reliability improvement, the power system was multi-looped for reliability enhancement, the problem of fault current happened. In this situation, there are several methods for fault current reduction likes current limiting reactor, replacing circuit breaker, splitting busses, etc. But these methods reached its limit, power system needs more fundamental solutions such as grid segmentation. In this paper, we assume grid segmentation already has been progressed using VSC BTB HVDC. Then, this paper discusses operating point of HVDC in metropolitan area considering loss minimization and handy flow control. The simulation is proceeded on 2027 KEPCO system.

  • PDF

熱機關의 最適 運轉條件 (The optimal operation condition of heat engine)

  • 정평석;김수연
    • 대한기계학회논문집
    • /
    • 제11권6호
    • /
    • pp.971-974
    • /
    • 1987
  • 본 연구에서는 최적설계를 위한 기초로서, 고정된 두 열원사이에서 작동하는 열기관을 예로 들어 운전조건에 따른 출력과 효율의 변화를 정성적으로 설명하여 출력 과 효율의 최대값이 극대값으로 나타남을 보이고, 경제적 측면에서 이들의 의의 및 경 제적 최적운전조건과의 관계 등을 고찰하려 한다.

산업용 서보 구동 시스템을 위한 자동 P/PI 속도 제어기 설계 (Automatic P/PI Speed Controller Design for Industry Servo Drives)

  • 배상규;석줄기;김경태;이동춘
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권12호
    • /
    • pp.616-623
    • /
    • 2003
  • Conventional P/PI speed controller of today's servo drives should be manually tuned the controller switching set-point by trial-and-errors, which may translate the drive system down-time and loss of productivity. The adjustable drive performance is heavily dependent on the quality of the expert knowledge and becomes inadequate in applications where the operating conditions change in a wide range, i.e., tracking command, acceleration/deceleration time, and load disturbances. In this paper, the demands on simple controls/setup are discussed for industry servo drives. Analyzing the frequency content of motor torque command, P/PI control mode switching is automatically performed with some prior knowledge of the mechanical dynamics. The dynamic performance of the proposed scheme assures a desired tracking response curve with minimal oscillation and settling time over the whole operating conditions. For comprehensive comparison of traditional P/PI control scheme, extensive test is carried out on actual servo system.

무상수리 정책에서 응급수리 적용의 비용분석 모델 (Cost Analysis Model for Minimal Repair in Free-Replacement Policy)

  • 김재중;김원중
    • 산업경영시스템학회지
    • /
    • 제20권43호
    • /
    • pp.241-247
    • /
    • 1997
  • This paper is concerned with cost analysis model in free-replacement policy. The free-replacement policy with minimal repair is considered as follows; in a manufacturer's view point operating unit is periodically replaced, if a failure occurs between minimal repair and periodic maintenance time, unit is remained in a failure condition. Also unit undergoes minimal repair at failures in minimal-repair interval. Then total expected cost is calculated according to the parameter of failure distribution in a view of consumer's. The expected costs are included repair cost and usage cost: operating, fixed, minimal repair and loss cost. Numerical example is shown in which failure time of item has weibull distribution.

  • PDF

정기보전제도에서 응급수리제품에 대한 무상수리 적용의 비용분석 모델 (A Cost Analysis Model of Minimal-Repairable Items in Free Replacement under the Periodic Maintenance Policy)

  • 김재중;김원중;조남호
    • 산업경영시스템학회지
    • /
    • 제19권39호
    • /
    • pp.89-98
    • /
    • 1996
  • This paper is concerned with cost analysis model in free -replacement policy under the periodic maintenance policy The free-replacement policy with minimal repairable item is considered as follows; in a manufacturer's view point operating unit is periodically replaced, if a failure occurs between minimal repair and periodic maintenance time, unit is remained in a failure condition. Also unit undergoes minimal repair at failures in minimal-repair interval. Then total expected cost per unit time is calculated according to maintenance period Tin a viewpoint of consumer's. The expected costs are included repair cost and usage cost: operating, fixed, minimal repair and loss cost. Numerical example is shown in which failure time of item has beta distribution.

  • PDF

소형 스크류식 원심펌프의 기액 이상류 특성 (Characteristics of a Small Screw-type Centrifugal Pump Operating in Air-Water Two-Phase Flow)

  • 김유택;다나카카즈히로;이영호
    • 한국유체기계학회 논문집
    • /
    • 제2권4호
    • /
    • pp.9-15
    • /
    • 1999
  • A screw-type centrifugal pump was manufactured to carry primarily solids and its impeller had a wide flow passage. However, there was an effect on the flow passage shape on delay of the choke due to entrained air not being clarified yet. Moreover, because its impeller has a particular shape, only few studies have tried to clarify the pump performance and details of internal flow pattern of that pump. For this reason, we carried out the pump performance experiment under air-water two-phase flow condition with different impeller tip clearances, pump rotational speeds and void fractions by using a small screw-type centrifugal pump designed to acquire basic data. In a general centrifugal pump, it was reported that there was a loss of pump head from single-phase flow to the choke due to air entrainment near the best efficiency point being large. However, the loss near the best efficient point in a screw-type centrifugal pump became less than that in a general centrifugal pump.

  • PDF

도로노면 유출수 처리를 위한 여과에서의 여재별 손실수두 특성 (A study on the headloss of filter media for treatment of Road Runoff)

  • 최원석;송창수;김석구
    • 상하수도학회지
    • /
    • 제22권6호
    • /
    • pp.697-704
    • /
    • 2008
  • Stormwater runoff from urban road area as non-point source has a tendency of including lots of pollutants at initial rain period. Recently, there are several cases of having installed treatment facilities for reducing pollution discharge from the impervious cover in urban area to prevent watershed environment from getting worse. The filtration type among non-point source treatment systems has been known as one of the most efficient system for treatment of non-point source pollutants. Therefore, various kinds of filter media such as expanded polypropylene(EPP), granular activated carbon, zeolite, perlite, illite, sand, gravel has been developed. This study was conducted to verify performance and hydraulic characteristics of filter media as measures for non-point source. The experiment was carried out to evaluate applicability and variation of 4 kind of most popular filter media(EPP, GAC, Zeolite, Perlite) in headloss with elapsed time and influent flow rate and to obtain data base that could be used to establish management plan for road runoff treatment. In experiment by tap water, it showed that EPP and perlite those are floatable materials showed stable operating performance and lower headloss than the others.

표면부착형 동기전동기의 철손을 고려한 벡터제어 (Vector Control of a Surface-mounted Permanent Magnet Synchronous motor Including Iron Loss)

  • 최영태;이득기;김흥근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2217-2220
    • /
    • 1997
  • To achieve the high performance speed control of synchronous permanent magnet motor, the influence of iron loss can not be negleced as the increase of driving frequency with high speed operation. This paper proposes a maximum efficiency control algorithm for permanent magnet synchonous motors by controlling the d-axis component of the armature current at any speed and torque. The objective of the optimum efficiency controller is to seek a combination of d-q axis current components which provide minimum input power (minimum losses) at a certain operating point by adding a small amout of perturbation to the d-axis current reference.

  • PDF