• 제목/요약/키워드: Operating parameter

검색결과 800건 처리시간 0.027초

A Simple and Robust Digital Current Control for a PM Synchronous Motor under the Parameter Variations

  • Kim, Kyeong-Hwa;Baik, In-Cheol;Young, Myung-Joong
    • Journal of Electrical Engineering and information Science
    • /
    • 제3권2호
    • /
    • pp.174-183
    • /
    • 1998
  • A simple and robust digital current control technique for a permanent magnet (PM) synchronous motor under the parameter variations is presented. Among the various current control schemes for an inverter-fed PM synchronous motor drive, the predictive control is known to give a superior performance. This scheme, however, requires the full knowledge of machine parameters and operating conditions, and cannot give a satisfactory response under the parameter mismatch. To overcome such a limitation, the disturbances caused by the parameter variations will be estimated by using a disturbance observer theory and used for the computation of the reference voltages by a feedforward control. Thus, the steady-state control performance can be significantly improved with a relatively simple control algorithm, while retaining the good characteristics of the predictive control. The proposed control scheme is implemented on a PM synchronous motor using the software of DSP TMS320C30 and the effectiveness is verified through the comparative simulations and experiments.

  • PDF

Online Compensation of Parameter Variation Effects for Robust Interior PM Synchronous Motor Drives

  • Shrestha, Rajendra L.;Seok, Jul-Ki
    • Journal of Power Electronics
    • /
    • 제11권5호
    • /
    • pp.713-718
    • /
    • 2011
  • This paper presents an online voltage disturbance estimator to achieve precise torque control of IPMSMs over a high speed operating region. The proposed design has a type of state-filter based on a Luenburger-style closed loop stator current vector observer. Utilizing the frequency response plot (FRF) approach, the estimation accuracy and the parameter sensitivities are analyzed. Accurate torque control and improved efficiency are provided with the decoupling of the effect of the parameter variations. The feasibility of the presented idea is verified by laboratory experiments.

공기분급식 미분쇄기의 운전조건이 미세분말의 크기에 미치는 영향 (Effects of Operating Conditions of an Air-Classifier Mill on the Particle Size of Fine Powder)

  • 신응수;김기성;김용욱
    • 한국생산제조학회지
    • /
    • 제25권6호
    • /
    • pp.426-433
    • /
    • 2016
  • This paper investigates the effects of operating conditions of an air classifier mill (ACM) on the particle sizes of PVC and rice hull. Based on the Box-Behnken matrix, the pulverization experiments were performed considering three operating factors: the air flow rate, the classifier speed and the mill speed. The response surface methodology was applied to identify the effects of the operating factors on the particle size. Results show that the particle sizes are governed by the linear variations of the operating factors. As less air is supplied and the mill rotates more slowly, the powder of both PVC and rice hull becomes finer. Furthermore, the classifier speed has a significant effect on the PVC powder but almost no effect on the rice hull powder. Thus, it is found that strong interactions exist between the material characteristics of a particle and the operating conditions of the ACM.

저마찰.고속 공압실린더의 마찰특성 연구 (An Experimental Study on the Frication Forces in Low Friction and High Speed Pneumatic Cylinders)

  • 김동수;김광영;최병오
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.476-479
    • /
    • 1997
  • A Knowledge of friction force in pneumatic cylinders makes it possible to improve cylinder description during simulation and to asses performance under changing operating conditions more accurately. Such knowledge is particularly useful, for example, when modeling continuous pneumatic positioning systems or predicting the operating conditions under which stick slip may occur, as well as in establishing preventive maintenance procedures for pneumatic cylinders. Friction force depends on a number of factors, including operating pressure, seal running speed on the cylinder barrel and rod, barrel material and surface roughness, seal dimensions and profile, seal material, lubrication conditions, cylinder distortion during assembly, and the operating temperature of cylinder components. This paper shows a system for measuring the friction force caused by a seal used in pneumatic cylinders. Results of experimental tests show that seal friction forces for grease lubricated service are clearly dependent on speed and pressure and are les sensitivity to other parameter. i.e., barrel material and roughness, seal material, and profile.

  • PDF

부채꼴형 추력베어링의 설계에 있어서 선단압력의 영향 (An Inflence of Inlet Pressure in the Design of Sector-Shaped Pad Thrust Bearings)

  • 김종수;김경웅
    • Tribology and Lubricants
    • /
    • 제10권4호
    • /
    • pp.33-42
    • /
    • 1994
  • An influence of inlet pressure on the performance of sector-shaped pad thrust bearings is investigated theoretically. The optimum conditions of film thickness or the optimum positions of pivot are found through the evaluation of load capacity for all available conditions of film thickness, under the operating conditions which the thermal and pad deformation effects can be neglected. The bearing performance including the inlet pressure effects is obtained for a wide operating ranges that inertia parameter(Re$^{*}$) is up to unity, and for the various cases of pad extent angle (number of pad) and the three cases of the angle between pads. The results show that the inlet pressure has a large influence on the performance of sector-shaped pad thrust bearings. In the design of sector-shaped pad bearings, due to the inlet pressure, the optimum number of pad is varied with the operating speed and the angle between pads, and the optimum position of pivot is located toward the leading edge along with the operating speed increases.

Estimation of Insulated-gate Bipolar Transistor Operating Temperature: Simulation and Experiment

  • Bahun, Ivan;Sunde, Viktor;Jakopovic, Zeljko
    • Journal of Power Electronics
    • /
    • 제13권4호
    • /
    • pp.729-736
    • /
    • 2013
  • Knowledge of a power semiconductor's operating temperature is important in circuit design and converter control. Designing appropriate circuitry that does not affect regular circuit operation during virtual junction temperature measurement at actual operating conditions is a demanding task for engineers. The proposed method enables virtual junction temperature estimation with a dedicated modified gate driver circuit based on real-time measurement of a semiconductor's quasi-threshold voltage. A simulation was conducted before the circuit was designed to verify the concept and to determine the basic properties and potential drawbacks of the proposed method.

Dual EKF-Based State and Parameter Estimator for a LiFePO4 Battery Cell

  • Pavkovic, Danijel;Krznar, Matija;Komljenovic, Ante;Hrgetic, Mario;Zorc, Davor
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.398-410
    • /
    • 2017
  • This work presents the design of a dual extended Kalman filter (EKF) as a state/parameter estimator suitable for adaptive state-of-charge (SoC) estimation of an automotive lithium-iron-phosphate ($LiFePO_4$) cell. The design of both estimators is based on an experimentally identified, lumped-parameter equivalent battery electrical circuit model. In the proposed estimation scheme, the parameter estimator has been used to adapt the SoC EKF-based estimator, which may be sensitive to nonlinear map errors of battery parameters. A suitable weighting scheme has also been proposed to achieve a smooth transition between the parameter estimator-based adaptation and internal model within the SoC estimator. The effectiveness of the proposed SoC and parameter estimators, as well as the combined dual estimator, has been verified through computer simulations on the developed battery model subject to New European Driving Cycle (NEDC) related operating regimes.

운전조건이 변화하는 공정설비의 신뢰도 분석기법 (A Method for Reliability Analysis of Process Facilities under Changing Operating Conditions)

  • 최수형
    • 한국가스학회지
    • /
    • 제7권4호
    • /
    • pp.20-23
    • /
    • 2003
  • 공정설비의 신뢰도분석은 자주 Weibull 분포에 기초를 둔 모델을 사용한다. 여기에 사용되는 매개변수들은 조업조건의 함수로서 실험에 의해 값이 결정되며 이를 토대로 신뢰도, 평균수명 및 표준편차를 계산한다 이때 기존 방법은 조업조건이 일정하다고 가정하고 이 매개변수들을 상수로 취급한다. 본 논문에서는 척도모수가 시간의 함수일 때 적용할 수 있는 신뢰도함수 및 이를 토대로 한 분석기법을 제안한다. 냉각팬에 대한 사례연구 결과 평균조업조건을 적용한 기존 방법과 큰 차이를 보였다. 제안된 방법은 다른 공정설비들에도 적용 가능하며 조업조건변화가 설비신뢰도에 미치는 영향을 효과적으로 고려할 수 있을 것으로 기대된다.

  • PDF

파라미터 설계에서 신경망을 이용한 최적화 방안 (Optimization procedure for parameter design using neural network)

  • 나명환;권용만
    • Journal of the Korean Data and Information Science Society
    • /
    • 제20권5호
    • /
    • pp.829-835
    • /
    • 2009
  • 다구찌 파라미터 설계는 품질특성의 변동을 최대한 줄이면서 동시에 품질특성의 평균을 목표치 가까이 가져가기 위한 설계인자의 최적조건을 찾는 방법이다. 제품의 설계단계에서 품질특성과 여러 개의 설계인자와의 관계는 복잡한 비선형 형태를 가지는 경우가 대부분이다. 신경망에서 유연한 모형선택과 학습능력은 알 수 없는 복잡한 비선형 형태를 파악하는데 아주 유용한 도구이다. 본 연구는 파라미터 설계에서 설계인자의 최적조건을 찾기 위하여 신경망을 이용한 최적화 방안을 제안하였다.

  • PDF

바닥 난방공간의 다인자 제어에 관한 실험적 연구 (An experimental study on the multiple parameter switching control for floor heating system)

  • 조성환;태춘섭;장철용
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.472-483
    • /
    • 1997
  • An experimental facility consisting of two $3{\times}4.4{\times}3.8m$ rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparision of two different control stratigies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study : (i) conventional on-off control based on feedback from room air temperature (ii) TPSC(two parameter switching control) (iii) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF