• Title/Summary/Keyword: Operating mode

Search Result 1,461, Processing Time 0.039 seconds

Study for Block Cipher Operating Mode Using Counter (카운터를 사용한 블록암호 운영모드에 관한 연구)

  • Yang, Sang-Keun;Kim, Gil-Ho;Park, Chang-Soo;Cho, Gyeong-Yeon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.243-246
    • /
    • 2008
  • This thesis suggests block cipher operating mode using ASR(Arithmetic Shift Register). ASR is ratted arithmetic shift register which is sequence that is not 0 but initial value $A_0$ multiplies not 0 or 1 but free number D on $GF(2^n)$. This thesis proposes ASR mode which changes output multiplying d and Floating ASR mode which has same function but having strengthened stability altering d. If we use ASR's output as a counter, there's advantage that it has higher stability and better speed than CTR. Also, ASR mode and FASR mode have advantage of Random access which is not being functioned on CTR mode, they can be widely used to any part which Random access is needed.

  • PDF

The performance of a heat pump with 3-piping system at various charging conditions (3관식 시스템 히트펌프의 충전량 변화에 따른 성능 특성에 관한 연구)

  • Song, In-Sik;Choi, Jong-Min;Joo, Young-Ju;Chung, Hyun-Joon;Kang, Hoon;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.288-293
    • /
    • 2008
  • The cooling load in winter is significant in many commercial buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. The development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the performance of a multi-heat pump with 3-piping system was investigated as a function of refrigerant charge and its performance was analyzed in cooling mode, heating mode, and heat recovery mode. COP in the heating or cooling mode showed little dependence on refrigerant charge at overcharge conditions, while those were strongly dependent on refrigerant charge at undercharge conditions and outdoor inlet temperature. In the heat recovery mode, the performance of the system was very sensitive to charge amount at all conditions. Optimum charge amount in the heat recovery mode was 14% lower than that in the cooling mode at the standard condition because the refrigerant only passed the indoor units. It is required to store the excessive refrigerant charge in a storage tank to optimize the system performance at operating modes.

  • PDF

An intelligent master controller with mixed mode for teleoperation (혼합제어모드를 이용한 텔레오퍼레이션 작업용 지능형 매스터 컨트롤러)

  • 이영우;권동수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.461-465
    • /
    • 1996
  • Position and rate control modes arc the two common modes for controlling remote manipulators with joysticks or hand controllers. Generally, position mode is easier for teleoperation than rate modes, when the manipulation work space is small or comparable to the human operator's control space. When the telemanipulator's work space is very large, human operator's control motion range must be large to allow telemanipulator's full range of motion resulting poor control resolution. One way to solve the poor resolution problem is to use indexing. However, rate mode can provide any higher degree of resolution without use of indexing. If two modes are mixed, master controller will be more convenient. The mixed mode algorithm, changes operating mode from position mode to rate mode or vise versa using fuzzy logic. The fuzzy logic algorithm, which has been designed to recognize the teleoperator's intended motion properly, provides an intelligence to a master controller.

  • PDF

Dual mode LCD with dynamic mode of horizontal switching

  • Lee, Joong-Ha;Lee, Seong-Ryong;Kim, Tae-Hyung;Jhun, Chul-Gyu;Yoon, Tae-Hoon;Kim, Jae-Chang
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.215-217
    • /
    • 2009
  • The authors propose a novel dual mode liquid crystal display (LCD) which has both dynamic and memory operating LCD modes. The mode uses a horizontal switching and bistable chiral splay nematic (BCSN) LCD. The proposed dual mode does not require pixeldivision and has a higher aperture ratio and resolution than the previously proposed dual mode. Experimental results of the memory and dynamic mode show a high contrast ratio of over 100:1.

  • PDF

A Study on the Cost Function Based on Operating Modes for Combined Cycle Power Plant (복합화력발전기의 운전조합별 비용함수에 관한 연구)

  • Lee, Jaehee;Yoon, Hyeok-Jun;Oh, Chang-Jin;Noh, Yu-Rim;Joo, Sung-Kwan;Ryu, Sangmin;Wi, Young-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.3
    • /
    • pp.358-364
    • /
    • 2018
  • In this study, the theoretical methodology is presented for estimating cost function based on operating modes for Combined Cycle Power Plant. The proposed method has estimated cost functions using the relationship between the gas turbine heat input and the output ratio of the steam turbine. In order to verify the proposed method, a regression analysis was performed using the single cost function estimated by the existing performance test method and the cost function for each operating mode estimated by the proposed method. The results of case studies using the 2016 generator input and output data are presented to show the effectiveness of the proposed method.

Effects on Performance of an Internal Heat Exchanger According to Charge Amount and Operating Condition in $CO_2$ Cooling Mode (이산화탄소 냉방운전 시 냉매충전량 및 운전조건에 따라 내부열교환기가 성능에 미치는 영향)

  • Kwak, Myoung-Seok;Cho, Hong-Hyung
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.1
    • /
    • pp.13-20
    • /
    • 2012
  • This is an experimental study on the performance characteristics of effective heat pump in the cooling mode using a single-stage compression $CO_2$ cycle with an IHX(internal heat exchanger). The performance of a single-stage compression with IHX was investigated according to charge amount and operating condition. Moreover, the performance characteristic of cooling operating was analyzed with the length of IHX. As a result, the optimum refrigerant charge amount was 2.2 kg. The optimal system COP for compressor frequency of 30, 40, 50, and 60 Hz was 3.493, 3.228, 2.978, and 2.659, respectively. Since the system with IHX can maintain large cooling capacity regardless of operating condition, the system performance doesn't reduce considerably under unfavorable condition. When the compressor frequency was 40 Hz, the COP for a system with IHX length of 3 m and 5 m was 3.361 and 3.51, respectively. By using the IHX into a $CO_2$ cooling system, the performance and reliability improves simultaneously.

A Case Study on the Seasonal Temperature Variations in Depth of a Vertically-installed Geothermal Heat Exchange Pipe (계절별 운전조건에 따른 수직형 지열교환기의 깊이별 지중온도 변화에 대한 사례 연구)

  • Hwang, Kwang-Il;Shin, Dong-Keol;Kim, Joong-Hun;Shin, Seung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.3
    • /
    • pp.45-50
    • /
    • 2009
  • To estimate the operating performances of the geothermal heat exchange pipe(GHEX), GHEXs of 400RT geothermal system were measured and analyzed through a year. The followings are the results. The temperature of 2 GHEXs installed 4m apart was fluctuated very similarly. When the geothermal system is nor operating or is operating as heating mode, the temperature of G.L.-170m was always higher than G.L.-70m's. But it reversed when the geothermal system is operating as cooling mode. And through a year, it has been observed that the temperature of G.L.-170m is increased approximately $1.5^{\circ}C$. With previously mentioned results, the heat transfer capacity of G.L.-70m's geological stratum is estimated as higher than that of the G.L.-170m.

Induction Heating Water Heater using Dual Mode Phase Shifted ZVS-PWM High Frequency Resonant Inverter (듀얼 모드 위상 시프트 ZVS PWM 제어 고주파 공진형 인버터를 이용한 IH 온수기)

  • Lee, Sang-Wook;Ryu, Yeoi-Joung;Woo, Kyung-Il;Park, Han-Seok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.2
    • /
    • pp.82-89
    • /
    • 2018
  • This paper presents a novel prototype of dual mode control based phase shift ZVS PWM high frequency load resonant inverter with lossless snubber capacitors in addition to a single active auxiliary resonant snubber for electromagnetic induction heating(IH) foam metal based consumer fluid dual packs(DPA) heater. The operating principle in steady state and unique features of this voltage source soft switching high frequency inverter circuit topology are described in this paper. The lossless snubber and auxiliary active resonant snubber assisted constant frequency phase shift ZVS PWM high frequency load resonant inverter employing IGBT power modules actually is capable of achieving zero voltage soft commutation over a widely specified power regulation range from full power to low power. The steady state operating performances of this dual mode phase shift PWM series load resonant high frequency inverter are evaluated and discussed on the basis of simulation and experimental results for induction heated foam metal heater which is designed for compact and high efficient moving fluid heating appliance in the consumer pipeline systems.

A Simple Resonant DC Link Snubber-Assisted Bi-directional Three-phase PWM Converter for Battery Energy Storage Systems

  • Hiraki, Eiji;Nakaoka, Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.3
    • /
    • pp.133-139
    • /
    • 2002
  • In this paper, a prototype of an active auxiliary quasi-resonant DC link (QRDCL) snubber assisted voltage source bidirectional power converter (AC to DC and DC to AC) operating at zero voltage soft-switching (BVS) PWM nlode is presented for a Battery Energy Storage System (BESS). The operating principle of this QRDCL circuit and multifunctional control-based converter system, including PWM inverter mode in which energy flows from the battery bank to the three-phase utility-grid in addition to an active PWM converter mode in which energy flows from the utility-grid to the battery banks are described respectively by the control implementation on the basis of d-q coordinate plane transformation. The multifunctional operation characteristics of this three-phase ZVS PWM bi-directional converter with QRDCL is demonstrated fer a BESS under the power conditioning and processing schemes of energy supply mode and energy storage mode, and compared with a conventional three-phase hard switching PWM bi-directional converter for a BESS. The effectiveness of the three-phase ZVS PWM hi-directional converter with QRDCL is proven via the simulation analysis.

Digital-controlled Single-phase Power-factor Correction Converter Operating in Critical Current Conduction Mode (임계전류도통모드로 동작하는 디지털제어 단상 역률개선 컨버터)

  • Jeong, Gang-Youl
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2570-2578
    • /
    • 2010
  • This paper presents a digital-controlled single-phase power-factor correction (PFC) converter operating in critical current conduction mode. The proposed converter utilizes the DC-DC boost converter topology for the PFC and operates the inductor current in critical conduction mode. Because the proposed converter is controlled digitally using a micom, its control circuit is simplified and the converter operates more effectively. This paper first explains the operational principles of the proposed converter and then analyzes the converter circuit. And this paper explains the implementation method of proposed converter with a detail design example, which is divided into software and circuit design parts. Also, it is shown through the experimental results of the prototype converter by the designed circuit parameters that the proposed converter has good performance as a single-phase PFC converter.