• Title/Summary/Keyword: Operating mode

Search Result 1,464, Processing Time 0.025 seconds

Development of Advanced Annunciator System for Nuclear Power Plants

  • Hong, Jin-Hyuk;Park, Seong-Soo;Chang, Soon-Heung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.185-190
    • /
    • 1995
  • Conventional alarm system has many difficulties in the operator's identifying the plant status during special situations such as design basis accidents. To solve the shortcomings, an on-line alarm annunciator system, called dynamic alarm console (DAC), was developed. In the DAC, a signal is generated as alarm by the use of an adaptive setpoint check strategy based on operating mode, and time delay technique is used not to generate nuisance alarms. After alarm generation, if activated alarm is a level precursor alarm or a consequencial alarm, it would be suppressed, and the residual alarms go through dynamic prioritization which provide the alarms with pertinent priorities to the current operating mode. Dynamic prioritization is achieved by going through the system- and mode-oriented prioritization. The DAC has the alarm hierarchical structure based on the physical and functional importance of alarms. Therefore the operator can perceive alarm impacts on the safety or performance of the plant with the alarm propagation from equipment level to plant functional level. In order to provide the operator with the most possible cause of the event and quick cognition of the plant status even without recognizing the individual alarms, reactor trip status tree (RTST) was developed. The DAC and the RTST have been simulated with on-line data obtained from the full-scope simulator for several abnormal cases. The results indicated that the system can provide the operator with useful and compact information fur the earlier termination and mitigation of an abnormal state.

  • PDF

A Study on the Wedge Angle of the Rail Clamp according to the Change of the Design Wind Speed Criteria (설계풍속 상향조정에 따른 레일클램프의 쐐기각에 대한 연구)

  • Lee, Jung-Myung;Han, Dong-Seop;Lee, Seong-Wook;Shim, Jae-Joon;Han, Geun-Jo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.12 s.189
    • /
    • pp.103-110
    • /
    • 2006
  • The rail clamp is very important device to prevent that a container crane slips along a rail due to the wind blast as well as to locate the crane in the set position during an operating mode. Recently, the design wind speed criteria were intensified from the wind speed of 16m/s to 35m/s during an operating mode, and from 50m/s to 75m/s during a stowed mode in Korea, according to the 'Inspection Criteria for Facilities and Equipments in Port' reformed after typhoon 'Maemi'. In order to design the wedge type rail clamp for the reinforced design wind speed criteria of 35m/s, we carried out the finite element analysis of the rail clamp with respect to the wedge angle, and analyzed the relationship between the wedge angle and the sliding distance of the rail clamp.

Characteristics of Exhaust Emission Reduction of Heavy Duty Diesel Engine by Oxidation Catalyst - Engine Bench Test - (산화촉매에 의한 대형디젤엔진의 배출가스 정화특성 -실차실험을 중심으로-)

  • 조강래;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.5
    • /
    • pp.443-454
    • /
    • 1998
  • Pt-V catalytic converter was installed on a heavy duty diesel engine and the characteristics of the emission reduction were tested using a engine dynamometer at various operating conditions. The emission reduction performance of Pt-V catalyst was also compared with that of a commercialized Pt catalyst currently being used in some of the heavy duty diesel engines in advanced countries. The effects of Pt-V and Pt catalysts on regulated and unregulated emissions were investigated using a 0.05 weight percent sulfur content fuel with an engine dynamometer Experiments for gaseous emissions (CO, HC and aldehyde) as well as particulate emissions (TPM, SOF and sulfate) have been conducted at several operating conditions such as T-7 mode, D-13 mode and S-13 mode before and after installing the Pt-V and Pt catalysts in the exhaust system. The emission reduction performance of Pt catalyst with respect to CO, HC, SOF, PAHs and aldehyde was found to be a little higher than that of Pt-V catalyst, but the Pt catalyst showed innate disadvantage of causing an increase of PM due to the sulfate formation via high SO2 conversion at high exhaust temperature, especially above 45$0^{\circ}C$.

  • PDF

Advanced Induction Heating Equipment using Dual Mode PWM-PDM Controlled Series Load Resonant Tank High Frequency Inverters

  • Fathy, Khairy;Kwon, Soon-Kurl;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.246-256
    • /
    • 2007
  • In this paper, a novel type auxiliary active edge resonant snubber assisted zero current soft switching pulse modulation Single-Ended Push Pull (SEPP) series load resonant inverter using IGBT power modules is proposed for cost effective consumer high-frequency induction heating (IH) appliances. Its operating principle in steady state is described by using each switching mode's equivalent operating circuits. The new multi resonant high-frequency inverter with series load resonance and edge resonance can regulate its high frequency output power under a condition of a constant frequency zero current soft switching (ZCS) commutation principle on the basis of the asymmetrical pulse width modulation (PWM) control scheme. Brand-new consumer IH products using the proposed ZCS-PWM series load resonant SEPP high-frequency inverter using IGBTs is evaluated and discussed as compared with conventional high-frequency inverters on the basis of experimental results. In order to extend ZCS operation ranges under a low power setting PWM as well as to improve efficiency, the high frequency pulse density modulation (PDM) strategy is demonstrated for high frequency multi-resonant inverters. Its practical effectiveness is substantially proved from an application point of view.

A Wind Turbine Simulator for Doubly-Fed Induction-type Generator with Automatic Operation Mode Change during Wind Speed Variation (가변 풍속시 운전모드 절환을 고려한 이중여자 유도형 풍력발전기의 시뮬레이터)

  • Song, Seung-Ho;Sim, Dong-Joon;Jeong, Byoung-Chang
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.349-360
    • /
    • 2006
  • Controller for doubly-fed induction-type wind generation system should be designed with mechanical power on blade. The controller in this paper consists of upper level controller and lower level controller. The upper level controller determines operating modes according to mechanical input power and calculates proper reference values. There are 4 operating modes - minimum speed control, variable torque control, torque limit control and idle mode. The lower level controller performs current regulated PWM control of rotor-side converter and grid-side inverter. A wind turbine simulator is implemented using doubly-fed induction-type generator and DSP based back-to-back converter to verify the performance of designed controller experimentally.

Unified Controller for Solar Array Simulator (동작지점 투영기법을 이용한 태양광패널 모사장치의 통합 제어기법)

  • Wellawatta, Thusitha;Seo, Young-Tae;Choi, Sung-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.2
    • /
    • pp.118-126
    • /
    • 2020
  • A solar array simulator is a special power supply that regulates the output voltage and current to simulate the characteristics of a photovoltaic panel. The operating point of the panel is difficult to control with a single controller because of the non-linearity of the output curve, which is determined by the amount of irradiation, temperature, and panel material. In the conventional method, the output curve is divided into sections through the current and the voltage mode controls. It reduces the overall performance of the system due to the interchanging control mode. By using the single mode controller, the noise interference of the measured value and the stability of the control around the maximum power point were demonstrated. To solve these issues, this study proposes a new unified controller. The stability of the controller was analyzed along with operating principles, and performance improvement was experimentally verified.

Study for a Novel Fast Response time Liquid Crystal Operating Mode using Control of Tilt Angle for Nematic Liquid Crystal (네마틱 액정의 틸트 제어를 이용한 새로운 고속응답 액정 모드에 관한 연구)

  • Kim, Sang-Hoon;Kang, Hyung-Ku;Hwang, Jeoung-Yeon;Bae, Yu-Han;Kim, Young-Hwan;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.181-184
    • /
    • 2005
  • In this paper, we have improved a novel fast response time liquid crystal operating mode using tilt angle in the unique condition by hot-plate equipment. The new control of tilt angle for nematic liquid crystal (NLC) with negative and positive dielectric anisotropy on the rubbed homeotropic polyimide (PI) using baking method by Hot-plate equipment was investigated. LC tilt angle decreased with increasing baking temperature and time. Especially, the low LC tilt angle of positive type NLC (${\Delta}n$>0) on the rubbed homeotropic PI surface by increasing temperature and time was measured. The EO characteristics of the high tilted OCB(HTOCB) mode using control of tilt angle on the homeotropic surface than that of conventional OCB cell can be improved. We suggest that the developed the HTOCB cell using control of tilt angle on the homeotropic surface is a promising technique for the achievement of a fast response time and a high contrast ratio.

  • PDF

A new method for safety classification of structures, systems and components by reflecting nuclear reactor operating history into importance measures

  • Cheng, Jie;Liu, Jie;Chen, Shanqi;Li, Yazhou;Wang, Jin;Wang, Fang
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1336-1342
    • /
    • 2022
  • Risk-informed safety classification of structures, systems and components (SSCs) is very important for ensuring the safety and economic efficiency of nuclear power plants (NPPs). However, previous methods for safety classification of SSCs do not take the plant operating modes or the operational process of SSCs into consideration, thus cannot concentrate on the safety and economic efficiency accurately. In this contribution, a new method for safety classification of SSCs based on the categorization of plant operating modes is proposed, which considers the NPPs operating history to improve the economic efficiencies while maintaining the safety. According to the time duration of plant configurations in plant operating modes, average importances of SSCs are accessed for an NPP considering the operational process, and then safety classification of SSCs is performed for plant operating modes. The correctness and effectiveness of the proposed method is demonstrated by application in an NPP's safety classification of SSCs.

Test of a Multilayer Dose-Verification Gaseous Detector with Raster-Scan-Mode Proton Beams

  • Lee, Kyong Sei;Ahn, Sung Hwan;Han, Youngyih;Hong, Byungsik;Kim, Sang Yeol;Park, Sung Keun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.5
    • /
    • pp.297-304
    • /
    • 2015
  • A multilayer gaseous detector has been developed for fast dose-verification measurements of raster-scan-mode therapeutic beams in particle therapy. The detector, which was constructed with eight thin parallel-plate ionization chambers (PPICs) and polymethyl methacrylate (PMMA) absorber plates, is closely tissue-equivalent in a beam's eye view. The gas-electron signals, collected on the strips and pad arrays of each PPIC, were amplified and processed with a continuous charge.integration mode. The detector was tested with 190-MeV raster-scan-mode beams that were provided by the Proton Therapy Facility at Samsung Medical Center, Seoul, South Korea. The detector responses of the PPICs for a 190-MeV raster-scan-mode proton beam agreed well with the dose data, measured using a 2D ionization chamber array (Octavius model, PTW). Furthermore, in this study it was confirmed that the detector simultaneously tracked the doses induced at the PPICs by the fast-oscillating beam, with a scanning speed of 2 m s-1. Thus, it is anticipated that the present detector, composed of thin PPICs and operating in charge.integration mode, will allow medical scientists to perform reliable fast dose-verification measurements for typical dynamic mode therapeutic beams.

A Design of an Embedded Microprocessor with Variable Length Instruction Mode (가변길이 명령어 모드를 갖는 Embedded Microprocessor의 설계)

  • 박기현;오민석;이광엽;한진호;김영수;배영환;조한진
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.4
    • /
    • pp.83-90
    • /
    • 2004
  • In this paper, we proposed a new instruction set(X32Y ISA) with 3 different types of instruction mode. The proposed instruction set organizes 32-bit, 24-bit, 16-bit instruction in order to solves a problem of memory size limitation in an embedded microprocessor. We designed a 32-bit 5 stage pipeline RISC microprocessor based on the X32V ISA. To verify the proposed the X32V ISA and a microprocessor, we estimated a program code size of multimedia application programs using a X32V simulator. In result, we verified that the Light mode and the Ultra Light mode obtains 8%, 27% reduction of a program code size through comparison with the Default mode. The proposed microprocessor was verified all X32V instructions execution at Xilinx FPGA with 33MHz operating frequency,