• 제목/요약/키워드: Operating mass flow rate

검색결과 200건 처리시간 0.027초

회전하는 산소전달장치가 부착된 동물세포 배양기의 조업 성능에 관한 고찰 (Performance of a Novel Bioreactor Equipped with Moving Membrane Tube-Aeration System)

  • 김영남;전병철;이진하;이현용
    • 한국미생물·생명공학회지
    • /
    • 제21권4호
    • /
    • pp.348-353
    • /
    • 1993
  • The optimal conditions for operating a moving-aeration bioreactor were determined as 30rpm and 150 (ml/min) of air flow rate, which can yield ca. 7.3 (l/h)of maximum mass transfer coefficient. It was also found that the agitation speed played much much important role than air input rate in oxgen transfer into the medium. $2.6{\times}10^6$ (cells/ml) and 0.6 (ml/l) of maximum cell denisty and IL-2 production were observed in batch cultivation of IL-2 producing BHK cell line. 0.53 (mM/l/h) of oxygen uptake rate was also estimated. The performance of a moving-aeration bioreactor (specific growth rate and oxygen uptake rate, etc.) was superior to other culture systems, such as cell-life and static membrane aeration bioreactors. Ii must be useful to apply this reactor to many culture processes by improving structural limitations in scaling-up the system.

  • PDF

중공사 막을 따라 흐르는 순수한 물의 유량, 압력손실, 투과수에 대한 실험과 이론적 고찰 (Experimental and Theoretical Consideration for Flow Rate, Pressure Drop, and Permeate Flow in a Hollow Fiber Membrane)

  • 이정묵;이범석
    • 멤브레인
    • /
    • 제22권6호
    • /
    • pp.470-480
    • /
    • 2012
  • 본 연구에서는 지름이 일정한 하나의 직선 관형 막을 가정하여 그 단위구간의 투과속도에 대한 물질수지를 세웠으며 이것을 기초로 하여 파이프의 정상상태 식과 함께 비선형 연립 2차 미분방정식을 이루었다. 이러한 관형 막의 압력손실을 표현한 연립방정식은 비선형이므로 Gauss-Seidel method와 같은 반복법에 의해서 해결될 수 있다. 이러한 수치해를 나타내기 위해 모사 알고리즘을 제시하였다. 또한 투과수는 운전 조건의 변화에 따라 변하므로 각 조건에서의 연립 방정식의 해를 수치적으로 적분하여 해결하였다. 모사의 결과를 검증, 해석하기 위해서 실제 중공사막과 유사한 관형 막을 사용하여 실험을 진행하였다. 본 연구에서는 중공사막을 유체가 흐를 때 발생하는 압력손실, 유량, 그리고 투과수의 관계를 분석적 방법을 이용해 제시하였고 이러한 이론적 기초를 바탕으로 실제 기공을 가진 막에 적용하여 그 정확성을 실험을 통하여 비교하였다.

강한 음향장에 구속된 고압 액적의 연소 (Unsteady Vaporization of Burning Droplet at High Pressure Environments With Linear Acoustic Mode)

  • 김성엽;신현호;윤웅섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1122-1127
    • /
    • 2004
  • an isolated droplet combustion exposed to pressure perturbations in stagnant gaseous environment is numerically conducted. Governing equations are solved for flow parameters at gas and liquid phases separately and thermodynamic parameters at the interfacial boundary are matched for problem closure. For high-pressure effects, vapor-liquid interfacial thermodynamics is rigorously treated. A series of parametric calculations in terms of mean pressure level and wave frequencies are carried out employing a n-pentane droplet in stagnant gaseous air. Results show that the operating pressure and driving frequency have an important role in determining the amplitude and phase lag of a combustion response. Mass evaporation rate responding to pressure waves is amplified with increase in pressure due to substantial reduction in latent heat of vaporization. Phase difference between pressure and evaporation rate decreases due to the reduced thermal inertia at high pressure. In addition to this, augmentation of perturbation frequency also enhances amplification of vaporization rate because the time period for the pressure oscillation is much smaller than the liquid thermal inertia time. The phase of evaporation rate shifts backward due to the elevated thermal inertia at high acoustic frequency.

  • PDF

사무소건물 태양열급탕시스템의 LCC 최적화 시뮬레이션 (Optimizing the Life Cycle Cost of a Solar Water Heating System in an Office Building Through Simulation)

  • 고명진;최두성;장재동;김용식
    • 설비공학논문집
    • /
    • 제22권12호
    • /
    • pp.859-866
    • /
    • 2010
  • This study examined the economics of a solar water heating system for an office building using life cycle cost (LCC) optimization simulations. The numerical simulations were conducted with TRNSYS and GenOpt employing the Hooke-Jeeves algorithm. The solar collector area, slope, mass flow rate per collector area and storage tank volume were selected as the main design parameters of the solar water heating system. The LCC optimization simulations of the system were carried out for cases where water temperature was $60^{\circ}C$ and $50^{\circ}C$. The results showed that for water temperature at $60^{\circ}C$ and $50^{\circ}C$ the collector area could be decreased by 17% and 28%, storage tank volume could be decreased by 49% and 54%, and mass flow rate per collector area increased by 5% and 9% respectively compared to a non-optimized system. The LCC of the system was reduced by 4% for $60^{\circ}C$ and 7% for $50^{\circ}C$. The initial installation cost of the system was reduced by 24% for $60^{\circ}C$ and 34% for $50^{\circ}C$. However, the operating cost of the system increased by 16% for $60^{\circ}C$ and 36% for $50^{\circ}C$ compared to a traditional solar water heating system.

항공정찰장비용 환경제어시스템의 냉각특성에 관한 실험적 연구 (Experimental Study on the Cooling Characteristics of an Environmental Control System for Avionic Reconnaissance Equipment)

  • 강훈;박형필;이응찬;김용찬;지용남;최희주;변영만;김영진;오광윤
    • 설비공학논문집
    • /
    • 제21권9호
    • /
    • pp.519-526
    • /
    • 2009
  • Environmental control system is adopted to control the thermal load from the avionic equipment in the reconnaissance pod which is mounted under a fighter aircraft, undergoing large and rapid environmental changes with the variations of flight altitude and velocity. In this study, an environmental control system was designed and built by adopting vapor compression cycle using R-124. The cooling performance characteristics of the system were measured varying operating parameters: thermal load in the pod, air mass flow rate through evaporator, condenser inlet air temperature, and air mass flow rate through condenser. The effects of the experimental parameters on the system performance were analyzed based on the experimental results. The problems on the designed system were also analyzed and the solutions were suggested to improve system efficiency and to obtain stable operation.

복합형 태양열 가열기의 일일 운전 특성 및 축열 성능에 관한 연구 (A Study on Thermal Storage Performance and Characteristics of Daily Operation of a Hybrid Solar Air-Water Heater)

  • 최휘웅;파쿠르 로커만;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제35권3호
    • /
    • pp.73-79
    • /
    • 2015
  • In this study, a thermal storage performance and characteristics of daily operation were investigated when the air and the liquid were heated simultaneously by a hybrid solar air-water heater that can make hot water as well as heated air. The hybrid solar air-water heater is kind of a flat plate solar collector that can make hot water and heated air by installing air channel beneath absorber plate of traditional flat plate solar collector for hot water. As a result of daily operation, maximum water temperature reached in a thermal storage was shown $44^{\circ}C$ on 73kg/h of air mass flow rate and about $40^{\circ}C$ on 176kg/h of air mass flow rate. Thus, the necessity of heating water in thermal storage by operating only liquid side was confirmed when the temperature of liquid in thermal storage is lower than we need. In case of efficiency investigated on daily operation, the thermal efficiency of the liquid side was decreased with increment of the inlet liquid temperature and decrement of the solar radiation, but efficiency of the air side was increased with increment of inlet liquid temperature difference as the traditional solar air heater. Total thermal efficiency of the collector was shown from 65.85% to 78.23% and it was decreased with increment of the inlet liquid temperature and decrement of solar radiation same as the traditional system.

분뇨처리장 방류수정화 갈대습지셀의 초기운영단계 질산성질소 제거 (NO3-N Removal of A Reed Wetland Cell Constructed for Purifying Effluent from A Night Soil Treatment Plant During Its Initial Operating Stage)

  • 양홍모
    • 한국환경복원기술학회지
    • /
    • 제7권5호
    • /
    • pp.100-106
    • /
    • 2004
  • $NO^3$-N removal was examined from July 2002 to December 2002 of a surface-flow constructed treatment wetland cell, which was a part of a treatment wetland system composed of four wetland cells and one distribution pond. The system was established on rice paddy near the Kohung Estuarine Lake located at the southern part of the Korean Peninsula. The lake and the paddy were formed by a salt marsh reclamation project. Effluent from a secondary-level treatment plant was funneled into the system. The investigated cell was created in June 2002. Its dimensions were 87 m in length and 14 m in width. It had an open water zone at its center, which was equivalent to 10 percent of its total area. Reeds(Phragmites australis) were transplanted from natural wetlands into the cell and their stems were cut at about 40 cm height from their bottom ends. Average 25 $m^3$/day of effluent from the plant was funneled into the cell by gravity flow and average 24.2$m^3$/day of its treated effluent was discharged into the Sinyang Stream flowing into the lake. Its water depth was maintained about 0.2 m and its hydraulic detention time averaged 5.2 days. The average height of the reed stems was 45.2 cm in July 2002 and 80.5 cm in September 2002. The number of stems averaged 40.3 stems/$m^2$ in July 2002 and 74.5 stems/$m^2$ in September 2002. The reeds were established initially well. $NO_3$-N loading rate of influent and effluent averaged 173.7 and $93.5mg/m2{\cdot}day$, respectively. Removal of $NO_3$-N averaged $80.2mg/m2{\cdot}day$ and its removal rate by mass was about 50 %. Considering the initial operation of the cell and the inclusion of the cold months of November and December in the analysis period, the $NO_3$-N removal rate was good.

오리나무 열매를 이용한 생물처리장치에서의 톨루엔 가스 처리효율 특성 (Characterization of Toluene Vapor Removal Efficiency Using Alnus Firma Fruit in a Biological Treatment Process)

  • 공남식;차수길;서정윤
    • 한국대기환경학회지
    • /
    • 제19권6호
    • /
    • pp.689-699
    • /
    • 2003
  • This study was to examine characteristics of treating toluene vapor, which gets to be problematic due to its harmful carcinogenicity and mass generation from various sources, through a biological treatment facility which is environment-friendly and adopts a high-efficient and low-cost clean technology. In order to identify whether Alnus Firma Fruit (AFF) can be used as a media for a bioreactor, its utility and basic operating factors, a study was conducted on pressure drop, supply of nutrient substances and retention time which are operating factors of a biofilter, and eliminating characteristics were compared between AFF and the conventional biological activatedcarbon (BAC) widely used as filter media. In the case of AFF, the initial microbial deposits was 2.3${\times}$10$^{7}$ CFU/g dry AFF, which represents the initial microbial density higher than the case of BAC showing 5.5${\times}$10$^{6}$ CFU/g dry BAC And it took about 2 weeks to acclimate until its eliminating rate got to be increased over 90%. As a result of comparing pressure loss taking place with the lapse of time between BAC and AFF, after 130 days passed at SV 25h$^{-1}$ , BAC showed that its eliminating efficiency had a tendency to drop greatly due to a great pressure loss (0.53\longrightarrow54.7 mm$H_2O$/m) caused by an excess of biomass as accumulated. On the other hand. AFF showed that the pressure drop was 0.53 mm$H_2O$/m, about 2 times as much as the initial pressure loss of 0.4 mm$H_2O$/m, which represents no great change in the pressure loss, and its eliminating efficiency was also shown to be continuously high. Therefore, when AFF was used as a filler for a biological treatment facility, a biological filter enabling improvement of the purifying efficiency to be promoted could be provided, and moreover, the pressure loss was so small that the filler replacement cycle or the back flushing cycle could be extended. So, even in terms of the operating cost, it was identified to be an economical filler When an inorganic material was used as a filler, the biofilters performance acted sensitively on whether nutrient substances were supplied or not. In the case of AFF with low adsorptivity, addition of ethyl-alcohol increased the solubility of toluene, and consequently, biodegradation got to be actively made by microbes, and thus, its eliminating rate could be increased. As the flow velocity and the inflow concentration got to be more increased, its eliminating rate got to be lower, and particularly, an increase in the flow velocity made its eliminating rate drop more greatly than an increase in the concentration.

Qualitative Analysis of the Major Constituents in Traditional Oriental Prescription Bang-poong-tong-sung-san by Liquid Chromatography/Ultraviolet Detector/Ion-Trap Time-of-Flight Mass Spectrometry

  • Eom, Han Young;Kim, Hyung-Seung;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • 제5권1호
    • /
    • pp.24-29
    • /
    • 2014
  • An advanced and reliable high performance liquid chromatography (HPLC)/ultraviolet detector (UV)/ion-trap time-of-flight (IT-TOF) mass spectrometry was developed for the simultaneous quantification of 19 marker compounds in Bang-poong-tong-sung-san (BPTS), a traditional oriental prescription. Various parameters affecting HPLC separation and IT-TOF detection were investigated, and optimized conditions were identified. The separation was achieved on a Capcell PAK C18 column ($1.5mm{\times}250mm$, $5{\mu}m$ particle size) using a gradient elution of acetonitrile and water containing 0.1% formic acid at a flow rate of 0.1 mL/min. The column temperature was maintained at $40^{\circ}C$ and the injection volume was $2{\mu}L$. IT-TOF system was equipped with an electrospray ion source (ESI) operating in positive or negative ion mode. The optimized electrospray ionization parameters were as follows: ion spray voltage, +4.5 kV (positive ion mode), or -3.5 kV (negative ion mode); drying gas ($N_2$), 1.5 L/min; heat block temperature, $200^{\circ}C$. Automatic $MS^n$ (n = 1~3) analyses were carried out to obtain structural information of analytes. Elemental compositions and their mass errors were calculated based on their accurate masses obtained from a formula predictor software. The marker compounds in BPTS were identified by comparisons between $MS^n$ spectra from standards and those from extracts. Moreover, the libraries of $MS^2$ and $MS^3$ spectra and accurate masses of parent and fragment ions for marker compounds were constructed. The developed method was successfully applied to the BPTS extracts and identified 17 out of 19 marker compounds in the BPTS extracts.

CFD Study for the Design of Coolant Path in Cryogenic Etch Chuck

  • Jo, Soo Hyun;Han, Ji Hee;Kim, Jong Oh;Han, Hwi;Hong, Sang Jeen
    • 반도체디스플레이기술학회지
    • /
    • 제20권2호
    • /
    • pp.92-97
    • /
    • 2021
  • The importance of processes in cryogenic environments is increasing in a way to address problems such as critical dimension (CD) narrow and bottlenecks in micro-processing. Accordingly, in this paper, we proceed with the design and analysis of Electrostatic Chuck(ESC) and Coolant in cryogenic environments, and present optimal model conditions to provide the temperature distribution analysis of ESC in these environments and the appropriate optimal design. The wafer temperature uniformity was selected as the reference model that the operating conditions of the refrigerant of the liquid nitrogen in the doubled aluminum path were excellent. Design of simulation (DOS) was carried out based on the wheel settings within the selected reference model and the classification of three mass flow and diameter case, respectively. The comparison between factors with p-value less than 0.05 indicates that the optimal design point is when five turns of coolant have a flow rate of 0.3 kg/s and a diameter of 12 mm. ANOVA determines the interactions between the above factor, indicating that mass flow is the most significant among the parameters of interests. In variable selection procedure, Case 2 was also determined to be superior through the two-Sample T-Test of the mean and variance values by dividing five coolant wheels into two (Case 1 : 2+3, Case 2: 3+2). Finally, heat transfer analysis processes such as final difference method (FDM) and heat transfer were also performed to demonstrate the feasibility and adequacy of the analysis process.