• Title/Summary/Keyword: Operating limit

Search Result 522, Processing Time 0.029 seconds

A Study on the Driving Principles of a Novel Non-contact Surface Actuator Using Combination of Magnetic Force (비접촉 평면 구동기의 자기력 조합 방식 구동 원리)

  • Jung, Kwang-Suk;Baek, Yoon-Su
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.3
    • /
    • pp.115-121
    • /
    • 2001
  • In micro automation technology, the concurrent realization of a high resolution and a large operating rage has been achieved by a dual actuator, usually called by piggy-back system, conventionally. But, because of its manufacturing cost, the complexity of control, and the limit of overall bandwidth, the contract-free and single servo actuators have been suggested with specific applications. In this paper, we suggest a novel non-contact surface actuator suing combination of the Lorentz force and the magnetized force, and discuss the actuating principles including an analytical approach. Differently from the existing planar system, an operating range of the suggested system can be expanded by an additional attachment of active elements. Therefore, it is estimated to be suitable for the next-generation moving system.

  • PDF

An Investigation on the Fault Currents in 22.9 kV Distribution System Due to the Increased Capacity and Operating Conditions of Power Transformers in 154 kV Substation (154 kV 변전소 주변압기의 용량 및 운전조건이 22.9 kV 배전계통의 고장전류에 미치는 영향)

  • Cho, Seong-Soo;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.302-310
    • /
    • 2008
  • In order to evaluate the nominal rating of breakers in distribution system due to the increased capacity and operating conditions of power transformers in 154 kV substation, the fault currents in distribution system were calculated by the conventional method and simulations of PSCAD/EMTDC program. Consequently, under the condition of the parallel operation of transformers, the fault currents exceed the nominal current of the breakers in some areas. Without NGR at the secondary neutral of the transformer, the current of single line-to-ground fault was bigger than that of 3-phase fault. Therefore, the results clearly show that the measures to limit the fault currents in distribution system are needed when the increased capacity of power transformers is introduced into 154 kV substation.

STUDY ON THE OPERATING CONDITION AND STABILITY OF CONTROL SYSTEM IN THE SPACE OF ADJUSTING PARAMETERS (조정파라미터 공간에서의 제어계 동작점과 안정성에 관한 연구)

  • 최순만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.470-477
    • /
    • 2000
  • The states of control loops in existing actual systems are changed according to time varying conditions of controllest process and other system components. Adjusting control parameters properly at site which is performed generally by Ziegler & Nichols mthod is important for safe and efficient operation, but the method may require much time to adjust and not easy to inexperienced engineers. This study is aimed to propose more handy method to adjust control parameters by plotting operating conditions on the space of adjusting parameters. One loop of model control system without perturbation condition has been adopted and its stability limit was plotted on the coordinates of Gain and Integral time which was acquired after analyzing Nyquist diagrams and time domain responses. The result showed that the sets of adjusting parameters according to critical stability and proper stability could be acquired reasonably through both responses and the curves on parameter space revealed available patterns for the purpose of easy maintenance of control characteristics.

  • PDF

Economic Evaluation Model of FMS Replacement under Technological Progress (FMS의 설비교체계획에 대한 경제적 평가모형)

  • 이상철;하정진
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.14 no.24
    • /
    • pp.7-13
    • /
    • 1991
  • Recently, in FMS composing of various automatic equipments, the machines with lower operating costs, and with higher operating costs and replacement costs resulting from deterioration have been appearing successively as a result of rapidly advances in technology. "Control Limit Policy" [1] by using Markov decision policy, a kind of optimal economic replacement decision, well reflects and represents this environment. In this paper, it is reviewed that the decision method of the forecasted replacement alternatives in planning horizon under technological advances is derived. The proposed method is applied to a numerical example and some characteristics are examined by sensitivity. It is clarified that the method is relatively insensitive to changes of parameters at the present decision. decision.

  • PDF

Sensitivity Analysis for Allowable Operating Period Based on the Flaw Tolerance Evaluation of ASME BPVC Section XI Appendix L (ASME BPVC Section XI Appendix L의 결함허용평가에 따른 허용운전주기 민감도 분석)

  • Changsik Oh;Dooho Cho;Myung Jo Jhung
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.2
    • /
    • pp.126-136
    • /
    • 2021
  • During operation of nuclear power plants, the fatigue assessment should be conducted repeatedly, considering changes of operating environments. For the case that cumulative usage factors (CUFs) may exceed the acceptance limit, flaw tolerance evaluation can be an alternative method to meet the regulatory requirements. In this respect, this paper analyzes the effects of the input variables for flaw tolerance evaluation based on ASME BPVC Section XI Appendix L. The reference analysis is performed for the example problem in NUREG/CR-6934. Then effects of the crack orientation, stress intensity factor solutions, thermal stress profiles, fatigue stress decomposition and fatigue crack growth curves are considered for the sensitivity analysis. The results show that the stress analysis considering the actual environment plays a crucial role in flaw tolerance evaluation.

Electric Field Analysis and Design of Direct current Arresters for electric Traction Vehicles (전철 탑재용 DC 피뢰기의 설계 및 전계분포 특성)

  • Cho, Han-Goo;Yoo, Dae-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1442_1442
    • /
    • 2009
  • This paper describes electric field analysis and design of direct current arresters for electric traction vehicles. Generally, DC arresters are used to protect the electric traction to limit the overvoltage invading into its inner electrical circuits. We could proposed operating voltage(Uc), the rated voltage(Ur). Finally maxwell 2D simulator based on the boundary element method was also introduced in order to verify the reliability of the DC arresters.

  • PDF

A Study on Load Control in a Steam Turbine Power Plant using Acquired Data (운전데이터에 의한 증기터빈 발전소의 부하제어에 관한 고찰)

  • Woo, Joo-Hee;Choi, In-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.749-751
    • /
    • 1999
  • We acquired operating data in an existing steam turbine power plant using analog control system to investigate operation characteristics. We analyzed a load control logic to develop a digital turbine control system. The load control logic is constituted of load target, load reference, loading rate, load limit and admission mode transfer of valve. The result of this paper is utilized to implement a digital turbine control system.

  • PDF

긴급제언 - 개방형 모바일 플랫폼 이해와 기술발전 방향

  • Kim, Yon Hong
    • Journal of the Korean Professional Engineers Association
    • /
    • v.46 no.2
    • /
    • pp.24-27
    • /
    • 2013
  • Following the mobile era, the technical architecture and the software development environment of mobile system plat form has been explained, and the future development direction has been summarized in the 5 ways. Closed operating system can be developed in the certain period. However, because of the lack of maintenance of the development infrastructure, it has been met its limit. Android, which is open source mobile, will be greatly spread, As it is the age SNS(Social Network System), I will introduce cases apply to formal community which used Twitter, Facebook, and so on.

  • PDF

Life Time Prediction Using Accelerated Ageing Test for a CR/CB Rubber Composite

  • Ahn, WonSool;Lee, Hyung Seok
    • Elastomers and Composites
    • /
    • v.52 no.4
    • /
    • pp.237-241
    • /
    • 2017
  • The tensile strength (TS) and elongation-at-break (EB) loss of a CR/CB rubber composite sample prepared for the automotive parts were measured after accelerated thermal ageing at temperatures of 100, 120, 140, and $150^{\circ}C$. The change in TS was observed to be linear from the master curve prepared using the time-temperature superposition-principle (TTSP). An Arrhenius type of shift factor, $a_T$ was used to predict the life time of the sample, and a plot of ln $a_T$ vs. 1/T was also shown to be linear. The activation energy ($E_a$) of the sample was calculated as 70.30 kJ/mole from the Arrhenius plot. The expected life time of the sample was predicted at the given operating conditions by applying Arrhenius analysis. Assuming the $E_a$ value was constant at lower operating condition, life time of the sample was calculated as 2.3 years when the life limit was set as time to reach the 20% decrease of the initial TS value at operating temperature of $40^{\circ}C$.

An experimental study on the dynamic behavior in an aero-valved pulsating combustor (공기밸브형 맥동연소기의 동적 특성에 관한 실험적 연구)

  • 임광열;최병륜;오상헌
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.5
    • /
    • pp.846-855
    • /
    • 1987
  • The experimental study was carried out to investigate the performance characteristics of the aero-valved pulsating combustor designed to increase the practical applications of the system. The geometric effect on the stable condition and the dynamic behavior of the system is identified. The equivalence ratio, the inflammability limit, the operating frequency, and thrust were also measured when the system oscillated stably. It is found that while the operating condition is sensitive to the diameter of the inlet pipe and the length of the tailpipe, the maximum value of the turn down ratio was obtained up to 3.2. The measured air flow rate shows that the equivalence ratio increases monotonously with the increasing fuel flow rate and decreasing air inlet diameter and tailpipe length. The measured operating frequency can be approximated by the simple linear equation and the discrepancy is within five percent. The system produced the maximum total thrust of 14N and the minimum specific fuel consumption of 0.155 Nm$^{3}$/h.N when the total thrust was 13N.