Establishment of Biotin Analysis by LC-MS/MS Method in Infant Milk Formulas (LC-MS/MS를 이용한 조제유류 중 비오틴 함량 분석법 연구)

  • Shin, Yong Woon;Lee, Hwa Jung;Ham, Hyeon Suk;Shin, Sung Cheol;Kang, Yoon Jung;Hwang, Kyung Mi;Kwon, Yong Kwan;Seo, Il Won;Oh, Jae Myoung;Koo, Yong Eui
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.5
    • /
    • pp.327-334
    • /
    • 2016
  • This study was conducted to establish the standard method for the contents of biotin in milk formulas. To optimize the method, we compared several conditions for liquid extraction, purification and instrumental measurement using spiked samples and certified reference material (NIST SRM 1849a) as test materials. LC-MS/MS method for biotin was established using $C_{18}$ column and binary gradient 0.1% formic acid/acetonitrile, 0.1% formic acid/water mobile phase is applied for biotin. Product-ion traces at m/z 245.1 ${\rightarrow}$ 227.1, 166.1 are used for quantitative analysis of biotin. The linearity was over $R^2=0.999$ in range of $5{\sim}60{\mu}g/L$. For purification, chloroform was used as a solvent for eliminating lipids in milk formula. The linearity was over 0.999 in range of 5~60 ng/mL. The detection limit and quantification limit were 0.10, 0.31 ng/mL. The accuracy and precision of LC-MS/MS method using CRM were 103%, 2.5% respectively. Optimized methods were applied in sample analysis to verify the reliability. All the tested milk formulas were acceptable contents of biotin compared with component specification and standards for nutrition labeling. The standard operating procedures were prepared for biotin to provide experimental information and to strengthen the management of nutrient in milk formula.

The 'Consequence Analysis' of Variables Affecting the Extent of Damage Caused by Butane Vapor Cloud Explosions (부탄가스 증기운폭발의 피해범위에 영향을 미치는 변수에 관한 고찰)

  • Char Soon-Chul;Choo Kwang-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.1-7
    • /
    • 2001
  • This paper presents a 'consequence analysis' for vapor cloud explosions caused by heavy gas leakages from commercially used storage tanks at petrochemical plants. Particularly, this paper emphasizes on evaluating the results of various vapor cloud explosion accidents from Butane storage tanks. Also this paper analyses the impact of variables on the accidents in order to acquire the optimum conditions for variables. $SuperChems^{TM}$ Professional Edition was applied to analyse the impact (If atmospheric and other variables in the situation where vapor cloud continuously disperses from the ground level. Under the assumption that practical operating conditions are selected as a standard condition, and Butane leaks from the storage tank for 15 minutes, the results show that the maximum distance of LFL (Lower Flammable Limit) was 52 meters and overpressure by the vapor cloud explosion was 1 psi at 128.2 meters. It is observed that the impact of the variables on accidental Butane storage tank leakage mainly varied upon atmospheric stability, wind velocity, pipe line size, visible length, etc., and changes in the simulation result occurred as the variables varied. The maximum distance of the LFL (Lower Flammable Limit) increased as the visible length became shorter, the size of the leak became larger, the wind velocity was decreased, and the climatic conditions became more stable. Thus, by analysing the variables that influence the simulation results of explosions of Butane storage tanks containing heavy gases, I am presenting the most appropriate method for 'consequence analysis' and the selection of standards for suitable values of variables, to obtain the most optimal conditions for the best results.

  • PDF

Establishment of Choline Analysis in Infant Formulas and Follow-up Formulas by Ion Chromatograph (이온크로마토그래프를 이용한 조제유류 및 영아용·성장기용 조제식 중 콜린 함량 분석법 연구)

  • Hwang, Kyung Mi;Ham, Hyeon Suk;Lee, Hwa Jung;Kang, Yoon Jung;Yoon, Hae Seong;Hong, Jin Hwan;Lee, Hyoun Young;Kim, Cheon Hoe;Oh, Keum Soon
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.5
    • /
    • pp.411-417
    • /
    • 2017
  • This study was conducted to establish the analysis method for the contents of choline in infant formulas and follow-up formulas by ion chromatograph (IC). To optimize the method, we compared several conditions for extraction, purification and instrumental measurement using spiked samples and certified reference material (CRM; NIST SRM 1849a) as test materials. IC method for choline was established using Ion Pac CG column and 18 mM $H_2SO_4$ mobile phase. The parameters of validation were specificity, linearity, LOD, LOQ, recovery, accuracy, precision and repeatability. The specificity was confirmed by the retention time and the linearity, $R_2$ was over 0.999 in range of 0.5~10 mg/L. The detection limit and quantification limit were 0.14, 0.43 mg/L. The accuracy and precision of this method using CRM were 95%, 2.1% respectively. Optimized methods were applied in sample analysis to verify the reliability. All the tested products were acceptable contents of choline compared with component specification for nutrition labeling. The standard operating procedures were prepared for choline to provide experimental information and to strengthen the management of nutrient in infant formula and follow-up formula.

A Study on Implementation and Performance of the Power Control High Power Amplifier for Satellite Mobile Communication System (위성통신용 전력제어 고출력증폭기의 구현 및 성능평가에 관한 연구)

  • 전중성;김동일;배정철
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.1
    • /
    • pp.77-88
    • /
    • 2000
  • In this paper, the 3-mode variable gain high power amplifier for a transmitter of INMARSAT-B operating at L-band(1626.5-1646.5 MHz) was developed. This SSPA can amplify 42 dBm in high power mode, 38 dBm in medium power mode and 36 dBm in low power mode for INMARSAT-B. The allowable errol sets +1 dBm as the upper limit and -2 dBm as the lower limit, respectively. To simplify the fabrication process, the whole system is designed by two parts composed of a driving amplifier and a high power amplifier. The HP's MGA-64135 and Motorola's MRF-6401 were used for driving amplifier, and the ERICSSON's PTE-10114 and PTF-10021 for the high power amplifier. The SSPA was fabricated by the RP circuits, the temperature compensation circuits and 3-mode variable gain control circuits and 20 dB parallel coupled-line directional coupler in aluminum housing. In addition, the gain control method was proposed by digital attenuator for 3-mode amplifier. Then il has been experimentally verified that the gain is controlled for single tone signal as well as two tone signals. In this case, the SSPA detects the output power by 20 dB parallel coupled-line directional coupler and phase non-splitter amplifier. The realized SSPA has 41.6 dB, 37.6 dB and 33.2 dB for small signal gain within 20 MHz bandwidth, and the VSWR of input and output port is less than 1.3:1. The minimum value of the 1 dB compression point gets more than 12 dBm for 3-mode variable gain high power amplifier. A typical two tone intermodulation point has 36.5 dBc maximum which is single carrier backed off 3 dB from 1 dB compression point. The maximum output power of 43 dBm was achieved at the 1636.5 MHz. These results reveal a high power of 20 Watt, which was the design target.

  • PDF

Risk Ranking Analysis for the City-Gas Pipelines in the Underground Laying Facilities (지하매설물 중 도시가스 지하배관에 대한 위험성 서열화 분석)

  • Ko, Jae-Sun;Kim, Hyo
    • Fire Science and Engineering
    • /
    • v.18 no.1
    • /
    • pp.54-66
    • /
    • 2004
  • In this article, we are to suggest the hazard-assessing method for the underground pipelines, and find out the pipeline-maintenance schemes of high efficiency in cost. Three kinds of methods are applied in order to refer to the approaching methods of listing the hazards for the underground pipelines: the first is RBI(Risk Based Inspection), which firstly assess the effect of the neighboring population, the dimension, thickness of pipe, and working time. It enables us to estimate quantitatively the risk exposure. The second is the scoring system which is based on the environmental factors of the buried pipelines. Last we quantify the frequency of the releases using the present THOMAS' theory. In this work, as a result of assessing the hazard of it using SPC scheme, the hazard score related to how the gas pipelines erodes indicate the numbers from 30 to 70, which means that the assessing criteria define well the relative hazards of actual pipelines. Therefore. even if one pipeline region is relatively low score, it can have the high frequency of leakage due to its longer length. The acceptable limit of the release frequency of pipeline shows 2.50E-2 to 1.00E-l/yr, from which we must take the appropriate actions to have the consequence to be less than the acceptable region. The prediction of total frequency using regression analysis shows the limit operating time of pipeline is the range of 11 to 13 years, which is well consistent with that of the actual pipeline. Concludingly, the hazard-listing scheme suggested in this research will be very effectively applied to maintaining the underground pipelines.

Review of 2019 Major Medical Decisions (2019년 주요 의료판결 분석)

  • Yoo, Hyun Jung;Park, Noh Min;Jeong, Hye Seung;Lee, Dong Pil;Lee, Jung Sun;Park, Tae Shin
    • The Korean Society of Law and Medicine
    • /
    • v.21 no.1
    • /
    • pp.107-152
    • /
    • 2020
  • During the main ruling in 2019, a number of rulings that were of interest or meaningful were handed down, such as just because the complication of medical practice has occurred, there is no presumption of negligence, a case involving a fall accident in which a lot of culpability has recently been made. the death of a well-known singer that caused a sensation, a case about damages caused by MERS in 2015, which is more meaningful in connection with damages caused by COVID-19, an infectious disease that has recently hit the world, including Korea. In preaching the principles of the law, just because there has been a complication caused by medical practice, there is no presumption of negligence, 'The scope of the complication without presumption of negligence' was determined differently by the court, the court was not able to specify the criteria. Specific circumstances were presented to limit the responsibility of the medical institution while acknowledging the malpractice of the medical institution in relation to the fall accident. In relation to the scope of damages, judgment was made on issues related to the calculation of lost profits of medical malpractice; criteria for determining celebrities' daily income, criteria for determining daily income in case of receiving survivor's pension due to medical accident, an incident in which the daily income is denied if the labor capacity is already lost at the time of a medical accident. But, it seems that judgments should be made based on clearer and more reasonable standards. Related to Medical Advertise, specific logic of judgment was presented as to whether it was interpreted as being in accordance with the specific prohibition listed in Article 27 paragraph 3 of the Medical Law, which is the criterion for violation of the Medical Law, or if it constitutes a significant harm to the order of the medical market. In response to the prohibition of operating the multiple medical institutions, the Constitutional Court decided that it was constitutional because it did not violate the regulations on excessive funding, and rationally limited the scope of the prohibited 'redundant operation'. The Supreme Court ruled for the first time that even a medical institution established and operated in violation of the Medical Service Act did not make it impossible to receive all medical care benefits implemented by a medical institution under the National Health Insurance Act. Significant rulings were finalized that recognized the existence of specific protection obligations for the people of the country in the management of infectious diseases.

The legal responsibility of the unmanned aircraft operators and insurance (무인항공기 운영자의 법적책임과 보험)

  • Kim, Jong-Bok
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.33 no.2
    • /
    • pp.367-418
    • /
    • 2018
  • Just as safety is the most important thing in aviation, safety is the most important in the operation of unmanned aircraft (RPA), and safety operation is the most important in the legal responsibility of the operator of the unmanned aircraft. In this thesis, the legal responsibility of the operator of the unmanned aircraft, focusing on the responsibility of the operator of the unmanned aircraft, was discussed in depth with the issue of insurance, which compensates for damages in the event of an accident First of all, the legal responsibility of the operator of the unmanned aircraft was reviewed for the most basic : definition, scope and qualification of the operator of the unmanned aircraft, and the liability of the operator of the Convention On International Civil Aviation, the ICAO Annex, the RPAS Manual, the Rome Convention, other major international treaties and Domestic law such as the Aviation Safety Act. The ICAO requires that unmanned aircraft be operated in such a manner as to minimize hazards to persons, property or other aircraft as a major principle of the operation of unmanned aircraft, which is ultimately equivalent to manned aircraft Considering that most accidents involving unmanned aircrafts fall to the ground, causing damage to third parties' lives or property, this thesis focused on the responsibility of operators under the international treaty, and the responsibility of third parties for air transport by Domestic Commercial Act, as well as the liability for compensation. In relation to the Rome Convention, the Rome Convention 1952 detailed the responsibilities of the operator. Although it has yet to come into effect regarding liability, some EU countries are following the limit of responsibility under the Rome Convention 2009. Korea has yet to sign any Rome Convention, but Commercial Act Part VI Carriage by Air is modeled on the Rome Convention 1978 in terms of compensation. This thesis also looked at security-related responsibilities and the responsibility for privacy infringement. which are most problematic due to the legal responsibilities of operating unmanned aircraft. Concerning insurance, this thesis looked at the trends of mandatory aviation insurance coverage around the world and the corresponding regulatory status of major countries to see the applicability of unmanned aircraft. It also looked at the current clauses of the Domestic Aviation Business Act that make insurance mandatory, and the ultra-light flight equipment insurance policy and problems. In sum, the operator of an unmanned aircraft will be legally responsible for operating the unmanned aircraft safely so that it does not pose a risk to people, property or other aircraft, and there will be adequate compensation in the event of an accident, and legal systems such as insurance systems should be prepared to do so.

Comparison of Naphthalene Degradation Efficiency and OH Radical Production by the Change of Frequency and Reaction Conditions of Ultrasound (초음파 주파수 및 반응조건 변화에 따른 나프탈렌 분해효율과 OH 라디칼의 발생량 비교)

  • Park, Jong-Sung;Park, So-Young;Oh, Je-Ill;Jeong, Sang-Jo;Lee, Min-Ju;Her, Nam-Guk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.2
    • /
    • pp.79-89
    • /
    • 2009
  • Naphthalene is a volatile, hydrophobic, and possibly carcinogenic compound that is known to have a severe detrimental effect to aquatic ecosystem. Our research examined the effects of various operating conditions (temperature, pH, initial concentration, and frequency and type of ultrasound) on the sonochemical degradation of naphthalene and OH radical production. The MDL (Method detection limit) determined by LC/FLD (1200 series, Agilient) using C-18 reversed column is measured up to 0.01 ppm. Naphthalene vapor produced from ultrasound irradiation was detected under 0.05 ppm. Comparison of naphthalene sonodegradion efficiency tested under open and closed reactor cover fell within less than 1% of difference. Increasing the reaction temperature from $15^{\circ}C$ to $40^{\circ}C$ resulted in reduction of naphthalene degradation efficiency ($15^{\circ}C$: 95% ${\rightarrow}$ $40^{\circ}C$: 85%), and altering pH from 12 to 3 increased the effect (pH 12: 84% ${\rightarrow}$pH 3: 95.6%). Pseudo first-order constants ($k_1$) of sonodegradation of naphthalene decreased as initial concentration of naphthalene increased (2.5 ppm: $27.3{\times}10^{-3}\;min^{-3}\;{\rightarrow}$ 10 ppm : $19.3{\times}10^{-3}\;min^{-3}$). Degradation efficiency of 2.5 ppm of naphthalene subjected to 28 kHz of ultrasonic irradiation was found to be 1.46 times as much as when exposed under 132 kHz (132 kHz: 56%, 28 kHz: 82.7%). Additionally, its $k_1$ constant was increased by 2.3 times (132 kHz: $2.4{\times}10^{-3}\;min^{-1}$, 28 kHz: $5.0{\times}10^{-3}\;min^{-1}$). $H_2O_2$ concentration measured 10 minutes after the exposure to 132 kHz of ultrasound, when compared with the measurement under frequency of 28 kHz, was 7.2 times as much. The concentration measured after 90 minutes, however, showed the difference of only 10%. (concentration of $H_2O_2$ under 28 kHz being 1.1 times greater than that under 132 kHz.) The $H_2O_2$ concentration resulting from 2.5 ppm naphthalene after 90 minutes of sonication at 24 kHz and 132 kHz were lower by 0.05 and 0.1 ppm, respectively, than the concentration measured from the irradiated M.Q. water (no naphthalene added.) Degradation efficiency of horn type (24 kHz) and bath type (28 kHz) ultrasound was found to be 87% and 82.7%, respectively, and $k_1$ was calculated into $22.8{\times}10^{-3}\;min^{-1}$ and $18.7{\times}10^{-3}\;min^{-1}$ respectively. Using the multi- frequency and mixed type of ultrasound system (28 kHz bath type + 24 kHz horn type) simultaneously resulted in combined efficiency of 88.1%, while $H_2O_2$ concentration increased 3.5 times (28 kHz + 24 kHz: 2.37 ppm, 24 kHz: 0.7 ppm.) Therefore, the multi-frequency and mixed type of ultrasound system procedure might be most effectively used for removing the substances that are easily oxidized by the OH radical.

A Study on Management of Records for Accountability of University student body's autonomy activity - Focused on Myongji University's student body - (대학 총학생회 자치활동의 설명책임성을 위한 기록관리 방안 연구 - 명지대학교 총학생회를 중심으로 -)

  • Lee, Yu Bin;Lee, Seung Hwi
    • The Korean Journal of Archival Studies
    • /
    • no.29
    • /
    • pp.175-223
    • /
    • 2011
  • A university is an organization charged with publicity and has accountability to the community for the operating process. Students account for a majority of members in a university. In universities, numerous creatures are pouring out every year and university students are major producers of these records. However, roles and functions of university students producing enormous amount of records as main agents of universities and focused concentration on produced records have not been made yet. It is reality that from the archival point of view, the importance of produced records of which main agents are university students has been relatively underestimated. In this background, this study attempted approach in archival point of view on records produced by university students, main agents. There are various types of records that university students produce such as records produced in the process of research and teaching as well as records produced in the process of various autonomy activities like clubs, students' associations. This study especially focused on university student autonomy activity process and placed emphasis on accountability securing measures on autonomy activity process of university students. To secure accountability of activities, records management should be based. Therefore, as a way to ensure accountability of unversity students autonomy activity, we tried to present records management systematization and records utilization measures. For this, a student body, a university student autonomy organization was analyzed and a student body of Myongji University Humanities Campus was selected as a specific target. First, to identify records management status, activities and organization and functions of the student body, we conducted an interview with the president of the student body. Through this, we analyzed the activities of the university student body and examined the necessity of accountability accordingly. Also, we derived the types and characteristics of records to be produced at each stage by analyzing the organization and functions of the student body of Myongji University. Like this, after deriving the types of production records according to the necessity, organization and functions of accountability and activities of the student body, we analyzed records management status of the present student body. First, to identify the general process status of activities of the student body, we analyzed activity process by stage of the student body of Myongji University. And we analyzed records management method of the student body and responsibility principal and conducted real condition analysis. Through this analysis, we presented the measures to ensure accountability of a university student body in three categories such as systematization of records management process, establishment of records management infrastructure, accountability guarantee measures. This study discussed accountability on society by analyzing activities and functions of a student body, targeting a student body, an autonomy organization of university students. And as a measure to secure accountability of a student body, we proposed a model for records management environment settlement. But in terms that a student body is an organization operated in one year basis, there is a limit that records management environment is hard to settle. This study pointed out this limit and was to provide clues when more active researches were carried out in the field of student records management in the future through presentation of student body records management model. Also, it is expected that the analysis results derived from this research will have significance in terms of school history arrangement and conservation.

Assessment of 1,4-Dioxane Removal in Polyester Wastewater by Activated Sludge and Its Microbial Property by 16S rDNA (폴리에스테르 중합폐수의 활성슬러지 공정에서의 1,4-다이옥산 제거 및 16S rDNA에 의한 미생물 군집특성 평가)

  • Han, Ji-Sun;So, Myung-Ho;Kim, Chang-Gyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.4
    • /
    • pp.393-400
    • /
    • 2008
  • 1,4-Dioxane($C_4H_8O_2$), which is used as a solvent stabilizer, could make harmful effects on ecosystem because of its higher solubility, toxicity and carcinogenic by US EPA. From 2011, its discharge limit to waterbody will be regulated at 5 mg/L by Ministry of Environment Republic of Korea. It was thus to investigate that the currently operating activated sludge in polyester manufacturing processes in Gumi can properly treat it to meet with the regulation standard. For that purpose, the removal rate of 1,4-dioxane and its microbial properties were assessed for a few companies(i.e. K, H and T). Its removal efficiency was the most highly recorded in H as 98% and then 77% for K, which met with the regulation standard. However, concentration of 1,4-dioxane of T was 23 mg/L in the effluent, which is more than the regulation standard. Aside from, microbial degradation test was done for 100 ppm of 1,4-dioxane in BSM (Basal salt medium) inoculated with each of activated sludge. After 7 days, 1,4-dioxane was completely removed in the test bottle inoculated with H sludge, 67% in T and 52% in K, which could confirm that the given activated sludge might have different biodegradability against the amount of 1,4-dioxane. Therefore, microbial diversity in each company was investigated by 16s rDNA cloning methods where a species, e.g. Methylibium petroleiphilum PM1, was the greatest observed from H and in lesser from K, but it was not detected from T. Methylibium petroleiphilum PM1 is known to efficiently degrade ether like methyl tertiary-butyl ether(MTBE). It is concluded that the activated sludge in H can be most effectively adopted for a biodegradation of 1,4-dioxane in the concern of industrial sector.