• Title/Summary/Keyword: Operating limit

Search Result 522, Processing Time 0.023 seconds

Improvement of Small-size Multi-housing Area Reconstruction Project Using AHP Analysis (AHP분석을 통한 가로주택정비사업의 개선방안)

  • Kim, Suk-Joon;Lee, Sang-Ho;Huh, Young-Ki
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.2
    • /
    • pp.79-85
    • /
    • 2019
  • The policy introduced recently in order to promote small-size reconstruction housing projects for rehabilitating downtown area consists of aged multi houses has been little practiced, as preferential provisions for such projects are more likely applicable for large projects. Several expert interviews and surveys were conducted to find efficient clauses to overcome the problems and their relative weights. As the results, it is revealed that 'relation of floor area ratio' and 'relaxation of building height limit criteria' are the most effective whereas 'purchasing and operating of residents' common facilities with public fund' is little. The study results would be a great interests for public institutions to rebuild aged housing area without destroying local communities and to provide socially disadvantaged class with rental housing at the same time.

Tissue Transglutaminase Antibody and Its Association with Duodenal Biopsy in Diagnosis of Pediatric Celiac Disease

  • Meena, Daleep K.;Akunuri, Shalini;Meena, Preetam;Bhramer, Ashok;Sharma, Shiv D.;Gupta, Rajkumar
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.22 no.4
    • /
    • pp.350-357
    • /
    • 2019
  • Purpose: This study aimed to evaluate a possible association between the anti-tissue transglutaminase antibody (anti-tTG) titer and stage of duodenal mucosal damage and assess a possible cut-off value of anti-tTG at which celiac disease (CD) may be diagnosed in children in conjunction with clinical judgment. Methods: This observational study was conducted at a gastroenterology clinic in a tertiary hospital from April 2012 to May 2013. Seventy children between 6-months and 18-years-old with suspected CD underwent celiac serology and duodenal biopsy. Statistical analyses were done using SPSS 16. Diagnostic test values were determined for comparing the anti-tTG titer with duodenal biopsy. An analysis of variance and Tukey-Kramer tests were performed for comparing the means between groups. A receiver operating characteristics curve was plotted to determine various cut-off values of anti-tTG. Results: The mean antibody titer increased with severity of Marsh staging (p<0.001). An immunoglobulin (Ig) A-tTG value at 115 AU/mL had 76% sensitivity and 100% specificity with a 100% positive predictive value (PPV) and 17% negative predictive value (NPV) for diagnosis of CD (p<0.001, 95% confidence interval [CI], 0.75-1). Conclusion: There is an association between the anti-tTG titer and stage of duodenal mucosal injury in children with CD. An anti-tTG value of 115 AU/mL (6.4 times the upper normal limit) had 76% sensitivity, 100% specificity, with a 100% PPV, and 17% NPV for diagnosing CD (95% CI, 0.75-1). This cut-off may be used in combination with clinical judgment to diagnose CD.

Velocity Aided Navigation Algorithm to Estimate Current Velocity Error (해조류 속도 오차 추정을 통한 속도보정항법 알고리즘)

  • Choi, Yun-Hyuk
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.3
    • /
    • pp.245-250
    • /
    • 2019
  • Inertial navigation system has navigation errors because of the error of inertial measurement unit (IMU) and misalignment over time. In order to solve this problem, aided navigation system is performed using global navigation satellite system (GNSS), speedometer, etc. The inertial navigation system equipped with underwater vehicle mainly uses speedometer and performed aided navigation because satellite signals do not pass through underwater. There are DVL, EM-Log, and RPM in the speedometer, and the sensors are applied according to the system environment. This paper describes velocity aided navigation using RPM of inertial navigation system operating in high speed and deep water environment. In addition, we proposes an algorithm to compensate the limit of RPM with straight direction and the current velocity error. There are results of monte-calo simulation to prove performance of the proposed algorithm.

Evaluation of Risk Factors for Uterine Myoma Diagnosed by Ultrasonography (초음파로 진단된 자궁근종의 위험인자 평가)

  • Yang, Sung-Hee
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.307-313
    • /
    • 2021
  • The purpose of this study was to analyze the risk factors for uterine myoma diagnosed by ultrasonography in Korea women and to evaluate the risk. Among the patients who visited the outpatient department of obstetrics and gynecology at I hospital in Busin between January 2019 and March 2021 for the purpose of examination, 98 patients in the experimental group diagnosed with uterine myoma and 163 patients in the normal control group without other diseases were retrospectively conducted. Among the general characteristics of the subjects, age, body mass index, parity, and menopause showed significant differences between the myoma group and the normal control group. ROC(receiver operating characteristic) curve analysis and logistic regression analysis were performed to obtain the cut off value and odds ratio that can predict the occurrence of uterine myoma. The cut off value for the prediction of uterine myoma was determined to be 30 years old and a body mass index of 23 kg/m2. After that adjusting for menopause, non menopausal cases with a body mass index of 23 kg/m2 and over 39 years of age had the highest odds ratio of 6.04. Therefore, premenopausal women over 40 years of age require regular checkups and thorough weight management. This study was conducted with a small number of subjects. Therefore, there is a limit to generalizing to all Korean women. However, based on this study if a large scale prospective study considering various variables is made, it can play a role as a predictive marker in early detection of uterine myoma.

Tomographic Imaging for Structural Health Monitoring Inspection of Containment Liner Plates using Guided Ultrasonic (유도초음파를 활용한 격납건물 라이너 플레이트 상시감시 모니터링 검사를 위한 토모그래피 영상화)

  • Park, Junpil;Cho, Younho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.16 no.2
    • /
    • pp.1-9
    • /
    • 2020
  • Large-scale industrial facility structures continue to deteriorate due to the effects of operating and environmental conditions. The problems of these industrial facilities are potentially causing economic losses, environmental pollution, casualties, and national losses. Accordingly, in order to prevent disaster accidents of large structures in advance, the necessity of diagnosing structures using non-destructive inspection techniques is being highlighted. The defect occurrence, location and defect type of the structure are important parameters for predicting the remaining life of the structure, so continuous defect observation is very important. Recently, many researchers have been actively researching real-time monitoring technology to solve these problems. Structure Health Monitoring Inspection is a technology that can identify and respond to the occurrence of defects in real time, but there is a limit to check the degree of defects and the direction of growth of defects. In order to compensate for the shortcomings of these technologies, the importance of defect imaging techniques is emerging, and in order to find defects in large structures, a method of inspecting a wide range using guided ultrasonic is effective. The work presented here introduces a calculation for the shape factor for evaluation of the damaged area, as well as a variable β parameter technique to correct a damaged shape. Also, we perform research in modeling simulation and an experiment for comparison with a suggested inspection method and verify its validity. The curved structure image obtained by the advanced RAPID algorithm showed a good match between the defect area and the shape.

Quality Control of Majoon-e-Nisyan and its Acute Oral Toxicity Study in Experimental Rats

  • Shaikh, Masud;Husain, Gulam M.;Naikodi, Mohammed Abdul Rasheed;Kazmi, Munawwar H.;Viquar, Uzma
    • CELLMED
    • /
    • v.11 no.1
    • /
    • pp.2.1-2.8
    • /
    • 2021
  • The clinical condition Amnesia causes difficulty in learning new information and the inability to recall past events. It is primarily concerned with recent memory loss. Majoon-e-Nisyan (MJN) is a polyherbal Unani formulation, present in a semi-solid form. It is widely used potent drug of the Unani System of Medicine (USM) for treating Nisyan (amnesia). In the present study polyherbal Unani formulation, MJN has been studied for its quality control and acute toxicity. Standardization (quality control) of drugs deals with drug identity, drug quality and purity determination. Standardization of MJN had been done as per the Unani pharmacopoeial parameters approved by World Health Organization (WHO) - Pharmacognostical parameters, Physico-chemical parameters, high-performance thin-layer chromatography (HPTLC), microbial load, aflatoxin, and heavy metals. Solvents and chemicals used in the study were of analytical grade and used instrument were calibrated. By conducting an acute oral toxicity study in rats, the safety of MJN was assessed. The limit test method of OECD guideline 425 was followed in the study. Results of standardization and standard operating procedures (SOPs) for preparation of MJN may serve as the standard reference in the future. The data generated in the study for the quality control of MJN proved the quality of formulation and shows that MJN is not toxic in rats following acute dosing up to 2000 mg/kg bw. The data obtained in the paper for MJN may be used as a standard guideline for preparation of the formulation which can save time, cost, and resources for future research endeavours.

A LiPF6-LiFSI Blended-Salt Electrolyte System for Improved Electrochemical Performance of Anode-Free Batteries

  • Choi, Haeyoung;Bae, YeoJi;Lee, Sang-Min;Ha, Yoon-Cheol;Shin, Heon-Cheol;Kim, Byung Gon
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.78-89
    • /
    • 2022
  • ANODE-free Li-metal batteries (AFLMBs) operating with Li of cathode material have attracted enormous attention due to their exceptional energy density originating from anode-free structure in the confined cell volume. However, uncontrolled dendritic growth of lithium on a copper current collector can limit its practical application as it causes fatal issues for stable cycling such as dead Li formation, unstable solid electrolyte interphase, electrolyte exhaustion, and internal short-circuit. To overcome this limitation, here, we report a novel dual-salt electrolyte comprising of 0.2 M LiPF6 + 3.8 M lithium bis(fluorosulfonyl)imide in a carbonate/ester co-solvent with 5 wt% fluoroethylene carbonate, 2 wt% vinylene carbonate, and 0.2 wt% LiNO3 additives. Because the dual-salt electrolyte facilitates uniform/dense Li deposition on the current collector and can form robust/ionic conductive LiF-based SEI layer on the deposited Li, a Li/Li symmetrical cell exhibits improved cycling performance and low polarization for over 200 h operation. Furthermore, the anode-free LiFePO4/Cu cells in the carbonate electrolyte shows significantly enhanced cycling stability compared to the counterparts consisting of different salt ratios. This study shows an importance of electrolyte design guiding uniform Li deposition and forming stable SEI layer for AFLMBs.

Raw Spectrum Analysis of operated UHF-Wind Profiler Radar in South Korea (국내 운용 UHF-윈드프로파일러 레이더의 원시 스펙트럼 분석)

  • Lee, Kyung-Hun;Kwon, Byung-Hyuk;Kim, Yu-Jin;Lee, Geon-Myeong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.5
    • /
    • pp.767-774
    • /
    • 2022
  • In this paper raw spectrum data were analyzed to suggest the moving forward of performance evaluation and quality control of wind profilers of four manufacturers operating in South Korea. For the analysis, the profile of the spectrum averaged by season and the profile of four statistical values (minimum, average, median, and maximum) calculated by Power Spectrum Density (PSD) were used. The quality of spectrum data was the best for LAP-3000, followed by YKJ3, PCL-1300, and CLC-11-H. In Cheorwon and Chupungnyeong, where PCL-1300 was installed, the variability of the spectrum due to ground clutter and non-meteorological signals was large, so ground clutter removal and signal processing such as moving average and multi-peak were required. In Gunsan and Paju, where CLC-11-H was installed, DC (Direct Current) bias and propagation folding were found, so it is necessary to remove the DC bias and limit the effective altitude for observation.

Aircraft Engine 150 hours Endurance Test under Conditions corresponding to the Operation Limitations for EASA Type Certification (EASA 형식 증명 목적을 위한 운전 한계조건에서의 항공기 엔진 150 시간 내구시험)

  • Kim, Jeongho;Ko, Kangmyung;Park, Sooyoul
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.3
    • /
    • pp.93-98
    • /
    • 2021
  • In Europe, it is necessary to fulfil the type certification criteria by the European Aviation Safety Agency (EASA) when developing an aircraft engine. According to type certification criteria, a 150 hours endurance test should be performed to verify the stability of the engine structure under the engine's operating limit conditions. The type certification criteria for the 150 hour endurance test are specified in JAR-E, which is the EASA type certification. Currently, the Arriel 2L2 engine is being developed in cooperation with a foreign manufacturer, and a 150 hours endurance test was performed. In this study, a 150 hours endurance test procedure is conducted in consideration of the operation characteristics of the currently developed engine.

Evaluation of exhaust emissions factor of agricultural tractors using portable emission measurement system (PEMS) (PEMS를 이용한 농업용 트랙터의 배기가스 배출계수 평가)

  • Wan-Soo Kim;Si-Eon Lee;Seung-Min Baek;Seung-Yun Baek;Hyeon-Ho Jeon;Taek-Jin Kim;Ryu-Gap Lim;Jang-Young Choi;Yong-Joo Kim
    • Journal of Drive and Control
    • /
    • v.20 no.3
    • /
    • pp.15-24
    • /
    • 2023
  • The aim of this study was to measure and evaluate the exhaust emission factors of agricultural tractors. Engine characteristics and three exhaust emissions (CO, NOx, PM) were collected under actual agricultural operating conditions. Experiments were performed on idling, driving, plow tillage, and rotary tillage. The load factor (LF) was calculated using the collected engine data, and the emission factor was analyzed using the LF and exhaust emissions. The engine characteristics and exhaust emissions were significantly different for each working condition, and in particular, the LF was significantly different from the currently applied 0.48 LF. The data distribution of exhaust emissions was different depending on the engine speed. In some conditions, the emission factor was higher than the exhaust emission standards. However, since most emission limit standards are values calculated using an engine dynamometer, even if the emission factor measured under actual working conditions is higher, it cannot be regarded as wrong. It is expected that the results of this study can be used for the inventory construction of a calculation for domestic agricultural machinery emissions in the future.