• Title/Summary/Keyword: Operating limit

Search Result 525, Processing Time 0.033 seconds

Design Direction of a Big Data based Performance Monitoring System using Quality Function Deployment (QFD를 이용한 빅 데이터 기반 성과 모니터링 시스템의 설계방향 도출)

  • Kim, Chang-Won;Kim, Taehoon;Seo, Junghoon;Lim, Hyunsu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.255-256
    • /
    • 2021
  • The performance measurement of construction projects has traditionally been evaluated as a prerequisite for successful project completion. Considering this importance, the UK and the US are operating quantitative performance measurement systems for construction projects. However, in the case of Korea, there is a limit to the use of existing methods due to the limitation of data collection. Recently, in consideration of the domestic situation, research is being conducted to measure the quantitative performance of a project by using big data including progress and project attribute information. Therefore, this study aims to present the design direction of a performance monitoring system using Quality Function Deployment.

  • PDF

Relationship between Exposure Concentrations to Methylene Chloride in Air and Carboxyhemoglobin Levels in Blood of Workers Engaged in Blowing, and Cleaning Operations (발포 및 세척 공정 근로자의 공기중 Methylene Chloride 노출 농도와 혈중 Carboxyhemoglobin 수준간의 상관관계에 관한 연구)

  • Shin, Yong Chul;Kim, Yang Ho;Yi, Gwang Yong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.1
    • /
    • pp.87-98
    • /
    • 1999
  • The objectives of this study were to evaluate exposures to airborne methylene chloride and postshift carboxyhemoglobin (COHb) in blood of workers engaged in processes using blowing or cleaning agents, and to investigate correlation between methylene chloride concentrations and the blood COHb levels of workers. The geometric mean (GM) of workers' exposures (8 hour-time weighted averages, TWA) to airborne methylene chloride during cleaning molds using rags wetted with the solvent in the manufacture of flexible polyurethane foam (GM = 61.4 ppm), during operating the dip tank for cleaning molds in the manufacture of lens (GM = 61.0 ppm), and during cleaning the blowing nozzles by spraying the solvent in the manufacture of shoes (GM = 117.2 ppm) were exceeded the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value ($TLV^{(R)}$)-Time Weighted Average (TWA) (50 ppm). The COHb levels were significantly different among groups (p<0.05). The average COHh levels in blood of non-smoking workers were 2.0% in. low-level (<50 ppm) exposure group, and 3.9 % in high-level (>50ppm) exposure group. The average COHb levels in smoking workers were 3.1% in low-level exposure group, and 4.8% in high-level exposure group. The blood COHb levels of no-exposed workers to methylene chloride were 1.8% in non-smoking group, and 2.8% in smoking group. It was found that the COHb level dependeds on the methylene chloride concentration and smoking habit, and was highly correlated with methylene chloride concentration in air. The correlation coefficient was 0.81 among non-smoking workers. The estimated COHb level (3.6%) and 95% upper confidence limit (4.0%) corresponding to TLV-TWA of methylene chloride exceeded the current ACGIH Biological Exposure Index (COHb 3.5%) for carbon monoxide. The estimated COHb level (5.4%) at 100 ppm exceeded the standard (5%) recommended by National Institute for Occupational Safety and Health (NIOSH) for preventing adverse cardiovascular effect. The estimated COHb value and 95% upper confidence limit at 25 ppm of the Occupational Safety and Health. Adminstration (OSHA) Permissible Exposure Limit-TWA (PEL-TWA) were 2.6% and 3.0%, respectively. It is suggested that COHb in blood be kept below 3.0% to comply with OSHA PEL-TWA.

  • PDF

Implementation about measurement of the head SAR and variable parameter according to operation control mode in brain MR study with 1.5Tesia (1.57 BRAIN MRI검사에서의 작동제어모드를 통한 두부 SAR측정과 변화인자에 관한 고찰)

  • Lee, Kyu-Su;Sim, Hyun;Moon, Ji-Hoon;Oh, Jae-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.58-60
    • /
    • 2007
  • Magnetic Resonance Imaging(MRI) has become a very widely used medical procedur e. Clo.sed and open systems are typically used with static magnetic fields at or below 2 Tesla. BWhole body SAR(specific absorbsion rate) is the value of SAR averaged over the entire body of the patient over any period of 15 minutes. Head SAR is the value of SAR averaged over the head of the patient for any period of 10 minutes. SAR is a measure of the absorption of electromagnetic energy in the body' (typically in watts per kilogram (W/kg)). The normal operating mode comprises values of head SAR not higher than 3 W/kg. The second level controlled operating mode comprises values higher than 3 W/kg. Current FDA guidance limits the SAR in the whole body. including the head to a range of 1.5 to 4.0 W/kg, depending on the patient's clinical condition. SAR, limit restrictions are incorporated in all MRI systems. and domestic' s guidance limits the SAR in a part body. including the head to 3.2w/kg and less. The purpose of this study is to evaluate on change of head SAR in using MRI pulse sequence and to check if exceed 3.2(w/kg) level in domestic a part exposure through measured head SAR. 23 patient's the average head SAR of pulse sequence is that T2WI sagittal is 0.5375. T2WI axial(FSE) is 0.4817, T1WI axial(SE) is, 0.8179. FLAIR axial is 0.4580. GRE axial is 0.0077, Diffusion is 0.0824w/kg. The head SAR exposed per patient was proved 2.3845w/kg less than the international standard. Coefficient of correlation for the relations body weight and SAR or for the relations ETL(echo train length) and SAR is 1 value. Coefficient of correlation for the relations between TR(time to repeat) and SAR is -0.602 value. so SAR increased relative to weight body and ETL. But the relations between TR and SAR is negative definite.

  • PDF

Manufacturing and Operating Performance of the Heat Pipe with Sintered Wick (소결윅 히트파이프의 제작 및 작동성능)

  • Yun, Ho-Gyeong;Moon, Seok-Hwan;Ko, Sang-Choon;Hwang, Gunn;Choy, Tae-Goo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.9
    • /
    • pp.1260-1266
    • /
    • 2002
  • In this study, to make an excellent heat pipe, the manufacturing technology of a sintered wick was investigated. Making a sintered wick is known to be very difficult but it has many advantages. For example, the porosity and pore size can be controlled and the capillary force is great. The mixture of copper and pore former powder was used as a wick material and ceramic-coated stainless steel was used as a mandrel which is necessary for vapor flow. To analyze the feature of the manufactured wick, not only porosity and pore size were measured but also the sintered structure was observed. A heat pipe with sintered wick was manufactured and the performance test of the heat pipe was performed in order to review cooling performance. The performance test results for the 4mm diameter heat pipe with the sintered wick shows the stability since the temperature difference between a evaporator and a condenser of the heat pipe is less than 4.4$^{\circ}C$, and thermal resistance is less than 0.7$^{\circ}C$/W, In the meantime the composite wick that is composed with sintered and woven wire was also examined. The heat transfer limit of the heat pipe with composite wick was enhanced about 51%~60% compare to the one with sintered wick.

A Study on the displacement characteristics of suspension elements for KTX (고속철도차량 현가계요소 변위특성 연구)

  • Hur H.M.;Kwon S.T.;Lee C.W.;Kim H.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.378-382
    • /
    • 2005
  • The opening of high speed railway upgraded our land transportation speed limit, causing lots of changes including living and culture and also paving the way for stepping up the railway technology. However, it is also true that we had a limit to adopt the existing railway system structured for 150km/h to the new structure requiring a higher speed of approximate 300km/h due to technological, based on the time and experience. More importantly, heading toward a step of operating such a high speed railway system, it has been practically and quickly proposed that the railway needs high speed railway engineering, maintenance technology of parts of the vehicles to have a stable maintenance foundation and localization of major parts. Therefore, this study was intended to research the actual displacement characteristics in runningg on an actual track for the purpose of developing the protective and maintenance technology of springs and dampers, which are core parts among suspension elements of a high speed railway vehicle. For this, it was researched the actual vehicle test and its interpretation centered on primary spring, which is used for the suspension system of a bogie, body-body dampers and body-bogie yaw damper. Also, to analyze the displacement characteristics of suspension system in the actual conditions of high speed railway vehicles, a vehicle‘s dynamic characteristics was analyzed and interpreted. At the same time, a tester for measuring the actual displacement of such suspension elements was designed and attached to actual vehicles, to measure the displacements that occur in running it on the Seoul-Busan line, one of major lines serviced by KTX. The displacement data gained from the test with actual vehicles was analyzed for its displacement distribution depending on the service sections and frequency, with which the valuable data necessary for any potential breakdown or maintenance in the future could be obtained.

  • PDF

Analysis of Water Purification Capability of the Spent Fuel Storage Pool Using Consolidated Fuel Storage in Uljin 1&2 (조밀화 핵연료 집합체 저장에 의한 울진 1&2호기의 사용후 핵연료 저장조 정화능력 해석)

  • Lim, Chae-Joon;Park, Goon-Cherl;Chung, Chang-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.22 no.2
    • /
    • pp.83-94
    • /
    • 1990
  • The radioactivity in the spent fuel storage pool is calculated to ensure to maintain its concentration below the permissible limit, when the storage capacity of Uljin nuclear power plant unit 1&2 is extended from 9/3 to 32/3 core using consolidated fuels in maximum density rack (MDR). For this evalulation, two models to calculate the spent fuel pool activities on the continuous and intermittent operating its purification system are developed and these results compared, The results of above two cases show that the current water purification system can not guarantee the radioactivity concentration below the design limit, 5$\times$10$^{-4}$ $\mu$Ci/ml, for the extention to 32/3 core. Therefore, it has been concluded that a modification of the current purification system is necessary to extend the spent fuel storage capacity with the above method. The alternative way suggested in this study is to increase the number of cation bed demineralizers.

  • PDF

Optimal Voltage Control Algorithm of Small Hydro Generators for Voltage Stabilization in Distribution system with large scaled PV systems (대용량 태양광전원이 연계된 배전계통의 전압안정화를 위한 소수력발전기의 최적전압제어 알고리즘)

  • Choi, Hong-Yeol;Choi, Sung-Sik;Kang, Min-Kwan;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.824-832
    • /
    • 2018
  • According to the government's policy to demonstrate and expand the renewable energy sources, distributed generators such as PV and WP are installed and operated in distribution systems. However, there are many issues related to power quality problems including over voltage and under voltage of customers. In order to overcome these problems, the electric power company have installed a step voltage regulator (SVR) in primary feeders interconnected with distributed generators, and also have established the technical guidelines for the distributed generators to stabilize the customer voltages in distribution systems. However, it is difficult to maintain the customer voltages within allowable limit. Therefore, this paper reviews the problems of voltage control by SVR in a distribution systems interconnected with a large amount of PV systems, and proposes characteristics of operating range and voltage control limit of the small hydropower generators. Also, with the estimation of the influence to the power system voltages from the voltage control mode of generators, this paper proposes the optimal voltage control algorithm of the small hydropower generators. By programming the proposed algorithm into control simulator of exciter, it is confirmed that the proposed algorithm can contribute the voltage stabilization in distribution systems interconnected with large scaled PV systems.

A Study on Determination of Range of Hazardous Area Caused by the Secondary Grade of Release of Vapor Substances Considering Material Characteristic and Operating Condition (물질특성 및 운전조건을 고려한 증기상 물질의 2차 누출에 따른 폭발위험장소 범위 선정에 관한 연구)

  • Seo, Minsu;Kim, Kisug;Hwang, Yongwoo;Chon, Youngwoo
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.13-26
    • /
    • 2018
  • Currently, local regulations, such as KS Code, do not clearly specify how to calculate the range of hazardous area, so the dispersion modeling program should be used to select dispersion. The purpose of this study is to present a methodology of determining the range of hazardous area which is simpler and more reasonable than modelling by using representative materials and process conditions. Based on domestic and overseas regulations that are currently in effect, variables affecting distance to LFL(Lower Flammable Limit) were selected. A total of 16 flammable substances were modelled for substance variables, process conditions variables, and weather conditions variables, and the statistical analysis selected the variables that affect them. Using the selected variables, a three-step classification method was prepared to select the range of locations subject to explosion hazard.

Feasibility study on the inductive fault current limiting cable

  • Lee, Sang Yoon;Choi, Jongho;Kim, Dong Min;Sim, Kideok;Cho, Jeonwook;Kim, Seokho
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.3
    • /
    • pp.24-28
    • /
    • 2013
  • Fault current limiting (FCL) cable is a kind of superconducting cable which has a function of limiting the fault current at the fault of power grid. The superconducting cable detours the fault current through its stabilizer to keep the temperature as low as possible. On the other hands, the FCL cable permits the temperature rise within some acceptable limit and the fault current is limited by the consequent increase of the resistance of superconducting cable. This kind of FCL cable is called 'resistive FCL cable' because it uses resistive impedance to limit the fault current. In this paper, we suggest a novel concept of FCL cable, which is named as 'inductive FCL cable'. The inductive FCL cable is similar as the magnetic shielding fault current limiter in its operating mechanism. The magnetic field of superconducting cable is almost perfectly shielded by the induced current at the shielding layer during its normal operation. However, at the fault condition, quench occurs at the shielding layer by the induced current higher than its critical current and the magnetic field is spread out of the shielding layer. It will induce additional inductive impedance to the superconducting cable and the inductive impedance can be increased more by installing some material with high magnetic susceptibility around the superconducting cable. We examined the feasibility of inductive FCL cable with simple elemental experiments. The current limiting performance of inductive FCL cable was estimated considering an arbitrary power grid and its fault condition.

Assessment of Spatial Dose Distribution in the Diagnostic Imaging Laboratory by Monte Carlo Simulation (몬테카를로 전산해석에 의한 X선 실습실의 공간선량분포 평가)

  • Cho, Yun-Hyeong;Kang, Bo Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.423-428
    • /
    • 2017
  • In this study, the calculation of the effective spatial dose distribution of the diagnostic imaging laboratory of K university was performed by the Monte Carlo simulation. The radiation generator has a maximum tube voltage of 150 kVp and a maximum current of 700 mA. Using the results, we compared the spatial effective dose distributions of diagnostic imaging laboratory when the shielding door was closed and opened. In conclusion, it was found that the effective dose in the operating room of the diagnostic imaging laboratory does not exceed the annual dose limit (6 mSv/y) of the student (occasional visitor) even when the door is opened. However, since the effective dose when the door is open is about 16 times higher in front of the lead glass window and about 3,000 times higher in front of the doorway than the case when the door is closed, closing the shielding door at the time of the practical exercising reduces unnecessary radiation exposure by great extent.