• Title/Summary/Keyword: Operating factor

Search Result 1,527, Processing Time 0.023 seconds

Robust Design Using Operating Window (기능창을 이용한 강건설계법)

  • Kim, Kyung-Mo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.1
    • /
    • pp.22-31
    • /
    • 2008
  • The operating window method is a novel approach in quality improvement. But it has not received deserved attention in academic research. If a critical factor for competing failure modes can be identified, the probability of failure can be reduced by widening the operating window of this factor. Traditional SN ratio for the operating window advocated by Taguchi has a critical shortcoming, which has been derived under the assumption that failure rates are determined by the operating window factor only. A new metric for robustness is given for the operating window method, which has relaxed the restrictive assumption of Taguchi's SN ratio. And procedures for determining optimal conditions based on the new metric is presented. The effectiveness of the proposed approach over the traditional practice is tested with the aid of a wave soldering process.

  • PDF

An Accelerated Degradation Test of a Electronics Appliance Compressor (전자제품용 컴프레서의 가속열화시험에 관한 연구)

  • Lee, Hoo-Jin;Yun, Won-Young
    • Journal of Applied Reliability
    • /
    • v.10 no.1
    • /
    • pp.25-38
    • /
    • 2010
  • In this paper, an accelerated degradation test procedure for an electronic appliance compressor is proposed. We investigate the amount of wear of the compressor and consider several factors as accelerating factors. Finally we select the operating pressure as a main accelerating factor. The test condition of accelerated degradation test is determined. The modified accelerating test reduces the test time in design phase by using the suggested accelerating factor.

Study of Single-Stage High-Power-Factor Electronic Ballast for fluorescent lamps operating in critical conduction mode (임계모드에서 동작하는 단일 전력단을 갖는 고역률 형광등용 전자식 안정기에 관한 연구)

  • Seo, C.S.;Kim, D.H.;Byun, Y.B.;Lee, P.S.;Sim, K.Y.;Oh, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1126-1128
    • /
    • 2001
  • A single-stage high-power-factor electron ic ballast operating in critical conduction mode is presented in this paper. The proposed topology is based on integration of a boost-like converter and a LCC Type half-bridge serial resonant inverter. The power-factor-correction(PFC) stage is a boost-like converter operating in critical conduction mode for positive and negative half cycle voltage respectively at line frequency (60Hz) so that a high power factor is achieved naturally. The simulated and experimental results for 100w fluorescent lamps operating at 42kHz switching frequency and 220V line voltage have been obtained.

  • PDF

Improvement of Operating Efficiency on Advanced Wastewater Plant Using Statistical Approach (고도처리 효율 향상을 위한 통계적 접근)

  • Moon, Kyung-Sook;Min, Kyung-Sub;Kim, Seung-Min;Lee, Chan-Hyung
    • Journal of Environmental Science International
    • /
    • v.17 no.4
    • /
    • pp.405-412
    • /
    • 2008
  • Statistical analysis technique was applied to operating parameters and removal efficiency data sets obtained from advanced wastewater treatment plant during 1 year. Through factor analysis three factors derived varimax rotation were selected each plant. Three components explained 96%, 87% of the total variance of the process, respectively. The components on $A_2O$ Plant were identified in the following order : 1) Shortening the SRT during high-flow period, 2) Keeping biomass high on winter 3) factor was related to DO. On DNR plant, we defined them as follows: factor 1, Prolonged the SRT during high-flow period; factor 2 was related to sludge return; factor 3, Influent BOD during low-DO period. This technique was believed to assist operators in identifying priorities to improve operation efficiency.

Statistical Analysis of Operating Parameters on Advanced Wastewater Treatment Plant (고도처리 하수처리장 운전조건의 통계분석)

  • Lee Chan-Hyung;Moon Kyung-Sook
    • Journal of Environmental Science International
    • /
    • v.14 no.2
    • /
    • pp.251-258
    • /
    • 2005
  • Statistical analysis between operating parameters and effluent quality on advanced wastewater treatment plant was performed. Through factor analysis four factors derived varimax rotation were selected each plant. Four components explained $80\%,\;82\%$ of the total variance of the process, respectively. The components on MLE plant were identified in the following order: 1) HRT increase and BOD load decrease by influent decrease, 2) Biomass, 3) SVI increase by internal return increase, 4) Microbial diversity by SRT increase. On $A_2O$ plant, we defined them as follows: factor 1, high MLSS by return rate increase, HRT increase by influent decrease; factor 2, biomass; factor 3, BOD of influent; factor 4 was relate to DO.

Design of Multi-winding Inductor for Minimum Inductor Current Ripple Using Optimized Coupling Factor

  • Kang, Taewon;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.231-232
    • /
    • 2016
  • This paper investigates the design of multi-winding coupled inductor for minimum inductor current ripple. Based on the general circuit model of coupled inductor together with the operating principles of dc-dc converter, the relationship between the ripple size of inductor current and the coupling factor is derived under the different duty ratio. The optimal coupling factor of n-phase multi-winding coupled inductor which corresponds to a minimum inductor ripple current becomes -(1/n-1), i.e. a complete inverse coupling without leakage inductance, as the duty ratio of steady-state operating point approaches 1/n, 2/n, ${\cdots}$ or (n-1)/n. In an opposite manner, the optimal coupling factor value of zero, i.e. zero mutual inductance, is required when the duty ratio of steady-state operating point approaches either zero or one. Therefore, coupled inductors having optimal coupling factor can minimize the ripple current of inductor and inductor size.

  • PDF

Design of Three-winding Coupled Inductor for Minimum Current Ripple in Battery Chargers

  • Kang, Taewon;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.195-196
    • /
    • 2015
  • This paper investigates the design of coupled inductor for minimum inductor current ripple in rapid traction battery charger systems. Based on the general circuit model of coupled inductor together with the operating principles of dc-dc converter, the relationship between the ripple size of inductor current and the coupling factor is derived under the different duty ratio. The optimal coupling factor which corresponds to a minimum inductor ripple current becomes -0.5, i.e. a complete inverse coupling without leakage inductance, as the steady-state duty ratio operating point approaches 1/3 or 2/3. In an opposite manner, the optimal coupling factor value of zero, i.e. zero mutual inductance, is required when the steady-state duty ratio operating point approaches either zero or one. Coupled inductors having optimal coupling factor can minimize the ripple current of inductor and battery current resulting in a reliable and efficient operation of battery chargers.

  • PDF

A Study on Single-Stage High-Power-Factor Electronic Ballast for Discharge Lamps Operating in Critical Conduction Mode (임계모드에서 동작하는 단일 전력단 고역률 방전등용 전자식 안정기에 관한 연구)

  • Seo Cheol-Sik;Park Jae-Wook;Sim Kwang-Yeal;Kim Hae-Jun;Won Jae-Sun;Kim Dong-Hee
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.12
    • /
    • pp.601-608
    • /
    • 2005
  • This paper presents a novel single-stage high-power-factor electronic ballast for fluorescent lamps operating in critical conduction mode. The proposed topology is based on integration of boost converter as power factor corrector(PFC) and a half-bridge high frequency parallel resonant inverter into a single stage. The input stage of the boost converter is operating in critical conduction mode for positive and negative half cycle voltage respectively at line frequency(60Hz). So that a boost converter makes the line current follow naturally the sinusoidal line voltage waveform. The simulated and experimental results for 100W fluorescent lamps operating at 42kHz switching frequency and 220V line voltage have been obtained. This proposed inverter will be able to be practically used as a power supply in various fields as induction heating applications, fluorescent lamp and DC-DC converter etc.

Experimental Study on Regenerator Under Cryogenic Temperature and Pulsating Pressure Conditions (극저온 맥동 압력 조건에서의 재생기에 관한 실험적 연구)

  • Nam, Gwan-U;Jeong, Sang-Gwon;Jeong, Eun-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.8
    • /
    • pp.1095-1101
    • /
    • 2002
  • An experimental apparatus was prepared to investigate thermal and hydrodynamic characteristics of regenerator at cryogenic temperature under pulsating pressure condition. The regenerator was pressurized and depressurized by a compressor with various operating frequencies. Cold end of the regenerator was maintained around 100 K by means of a liquid nitrogen heat exchanger. Instantaneous gas temperature and mass flow rate were measured at both ends of the regenerator during the whole pressure cycle. Pulsating pressure drop across the regenerator was also measured to see if it could be predicted by a friction factor at steady flow condition. The operating frequency of pressure cycle was varied between 3 and 60 Hz, which are typical operating frequencies of Gifford-McMahon, pulse tube, and Stilting cryocoolers. First, the measured friction factor for typical wire screen mesh regenerator was nearly same as steady flow friction factor for maximum oscillating Reynolds number up to 100 at less than 9 Hz. For 60 Hz operations, however, the discrepancy between oscillating flow friction factor and steady flow one was noticeable if Reynolds number was higher than 50. Second, the ineffectiveness of regenerator was directly calculated from experimental data when the cold-end was maintained around 100 K and the warm-end around 293 K, which simulates an actual operating condition of cryogenic regenerator. Influence of the operating frequency on ineffectiveness was discussed at low frequency range.

A Study on the Development of Verbal Abuse Scale for Operating Room Nurses (수술실 간호사가 경험하는 언어폭력 측정도구의 개발)

  • Yoon, Ke-Sook;Chung, Hye Seon;Park, Soon-Ae;Jang, Boo-Young;Kim, Hye-Ran;Ohm, Hyun-Sin;Sung, Young-Hee;Nam, Kyung-Dong
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.11 no.2
    • /
    • pp.159-172
    • /
    • 2005
  • Purpose: The Purpose of this study was to development a verbal abuse scale for operating room nurses in Korea. Method: To achieve the purpose of the study, a questionnaire was developed to interview 30 nurses and distributed to 761 nurses who working at 28 general hospital in Korea from september 7 to November 25, 2004. Item analysis and factor analysis were carried out to validate violence predicting scale. Cronbach's Alpha coefficient was used to test reliability of the scale. The data were analyzed by using SPSS/WIN 11.5 program. Result: As a result of the item analysis and factor analysis, 17 items were selected from the total of 30 items, and four factors were labeled as 'self esteem abuse by nurses(7 items)', 'self esteem abuse by physicians(6 items)', 'sexual abuse by physicians(2 items)', 'colleague abuse by physicians(2 items)'. Four factors were explained by 60.8% out of the total variance. The first factor explained 35.456%, second factor explained 12.401% and third factor explained 6.637%. And fourth factor explained 6.304%. Reliability of the factors were tested by Cronbach's Alpha coefficient and result was 0.885. Conclusion: The scale was identified to be a tool with a high degree of reliability and validity. Therefore, this scale can be effectively utilized for assessment of verbal abuse for operating room nurses by nurses and physicians in Korea.

  • PDF