• Title/Summary/Keyword: Operating duty

Search Result 252, Processing Time 0.024 seconds

A Study on the Design of Digital Controllers with Automatic Calibration (자동 보정형 디지털 제어기 설계에 관한 연구)

  • 나승유;박민상
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.413-416
    • /
    • 1998
  • Sensitivity and calibration considerations are most important in the design and implementation of real control systems. Ideally parameter changes due to various causes should not appreciably affect the system's performances. But all the values of physical components of the plants and controllers as well as the relevant environmental conditions change in time, thus the output performance can be deteriorated during the operating span of the system. Naturally the duty of calibration or the prevention of performance deterioration due to excessive component sensitivity should be provided to the control system. In this paper, we propose a digital controller which has the capability of calibration and gain adjustment as well as the execution of control law. Specifically the problems of gain adjustment and offset calibration in the light source and CdS sensor module for position measurement in a flexible link system are considerably resolved. The parameters of measurement module are prone to change due to environmental brightness conditions resulting in poor steady state performance of the overall control system. Thus a proper method is necessary to provide correction to the changed values of gain and offset in the position measurement module. The proposed controller, whenever necessary, measures the open-loop characteristics, andthen calculates the offset and sensor gain correction values based on the prepared standard measurements. It is applied to the control of a flexible link system with the gain and offset calibration porblems in the light sensor module for position to show the applicability.

  • PDF

Design and fabrication on 2.7-2.9 GHz, 1.5 kW pulsed Solid state power amplifier (1.5 kW, 2.7-2.9 GHz, 반도체 펄스 전력 증폭기 설계 및 제작)

  • Jang, S.M.;Choi, G.W.;Joo, J.H.;Choi, J.J.;Park, D.M.
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.91-96
    • /
    • 2005
  • In this paper, describes the design and performance of a 1.5 kW solid-state pulsed power amplifier, operating over 2.7-2.9 GHz at a duty of 10% and with a pulse width of 100 us for radar application. The solid-state pulsed power amplifier configures a series of 8-stage cascaded power amplifier with different RF output power levels. Low loss Wilkinson combiners are used to combine output powers of six 300W high power solid state modules. Tests show peak output power of 1.61 kW, corresponding to PAE of 26.2% over 2.7-2.9 GHz with pulse width of 100 us and a PRF of 1 kHz.

  • PDF

Business Information Visuals and User Learning : A Case of Companies Listed on the Stock Exchange of Thailand

  • Tanlamai, Uthai;Tangsiri, Kittisak
    • Journal of Information Technology Applications and Management
    • /
    • v.17 no.1
    • /
    • pp.11-33
    • /
    • 2010
  • The majority of graphs and visuals made publicly available by Thai listed companies tend to be disjointed and minimal. Only a little over fifty percent of the total 478 companies included graphic representations of their business operations and performance in the form of two or three dimensional spreadsheet based graphs in their annual reports, investor relations documents, websites and so on. For novice users, these visual representations are unlikely to give the big picture of what is the company's financial position and performance. Neither will they tell where the company stands in its own operating environment. The existing graphics and visuals, in very rare cases, can provide a sense of the company's future outlook. For boundary users such as audit committees whose duty is to promote good governance through transparency and disclosure, preliminary interview results show that there is some doubt as to whether the inclusion of big-picture visuals can really be of use to minority shareholders. These boundary users expect to see more insightful visuals beyond those produced by traditional spreadsheets which will enable them to learn to cope with the on-going turbulence in today's business environment more quickly. However, the debate is still going on as to where to draw the line between internal or external reporting visuals.

  • PDF

A Ternary Microfluidic Multiplexer using Control Lines with Digital Valves of Different Threshold Pressures (서로 다른 임계압력을 가지는 디지털 밸브가 설치된 제어라인을 이용한 3 진 유체분배기)

  • Lee, Dong-Woo;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.6
    • /
    • pp.568-572
    • /
    • 2009
  • We present a ternary microfluidic multiplexer unit, capable to address three flow channels using a pair of control lines with two different threshold pressure valves. The previous binary multiplexer unit addresses only two flow channels using a pair of control line with identical threshold pressure valves, thus addressing $2^{n/2}$ flow channels using n control lines. The present ternary multiplexer addressing three flow channels using a pair of control lines, however, is capable to address $3^{n/2}$ flow channels using n control lines with two different threshold pressure valves. In the experimental study, we characterized the threshold pressure and the response time of the valves used in the ternary multiplexer. From the experimental observation, we also verified that the present ternary multiplexer unit could be operated by two equivalent valve operating conditions: the different static pressures and dynamic pressures at different duty ratio. And then, $3{\times}3$ well array stacking ternary multiplexers in serial is addressed in cross and plus patterns, thus demonstrating the individual flow channel addressing capability of the ternary multiplexer. Thus, the present ternary multiplexer reduces the number of control lines for addressing flow channels, achieving the high well control efficiency required for simple and compact microfluidic systems.

The Emission Characteristics of Bio-Diesel Fuel in Heavy-Duty Engine (바이오 디젤 적용에 따른 대형엔진의 배출가스 특성)

  • Kim, Sun-Moon;Eom, Myoung-Do;Hong, Ji-Hyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.5
    • /
    • pp.499-506
    • /
    • 2010
  • Recently, a great deal of attention have been directed to the use of alternative fuels as a means to reduce vehicular emissions. As one of the promising alternative fuels, bio-diesel has advantages of a wide adaptability without retrofit of diesel engine. It is also effective enough to reduce CO, THC, $SO_x$, polycyclic aromatic hydrocarbons (PAHs) and PM. In this study, we investigated the emission characteristics of biofuels between different operating conditions, i.e., engine speed (1,400 rpm and 2,300 rpm), engine load (10% and 100%), bio-diesel blending (BD0, BD5 and BD20), and recirculation (EGR) rate of exhaust gas (0% and 20%). Relative performance of the system was evaluated mainly for the greenhouse gases ($CH_4$, $N_2O$ and $CO_2$). In addition, emission characteristics of ND-13 mode were also tested against both greenhouse gases and other airborne pollutants under emission regulation. The relative composition of bio-diesel has shown fairly clear effects on the emission quantities of CO, THC, and PM emission, although it was not on $NO_x$ and greenhouse gases. EGR rate has shown trade-off characteristics between $NO_x$ and PM.

The Design of the analog MPPT by the control of the operating point of a solar array voltage and current (태양 전지의 전압, 전류 동작점 제어를 이용한 아날로그 MPPT 설계)

  • Park, Hee-Sung;Park, Sung-Woo;Jang, Jin-Beak;Jang, Sung-Soo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.255-258
    • /
    • 2004
  • The SAR(Solar Array Regulator) of KOMPSAT(Korea Multi Purpose SATellite)-1, 2 regulates a photovoltaic power according to the duty ratio commands of the ECU. But the ECU has so many other jobs that it can not calculate the solar array condition immediately. It means the SAR cannot always generate the maximum power of a photovoltaic. Nowadays, the commercial photovoltaic systems are using a controller operated by digital processing. But the usage for satellite is not adaptable. It is not easy to find the processor of the space grade and the price is expensive. So in this paper, the simple analog MPPT(Maximum Power Point Tracking) algorithm is proposed for the small satellite in LEO. This algorithm does not need any calculation of power by multiplication of voltage and current md a measurement of the solar array temperature. It is consist of only two sample and hold circuits, two comparators, a flip-flop, and an integrator. The proposed MPPT algorithm is verified by the simulation and experimental.

  • PDF

Character of Induction Heating ZCS PWM SEPP High Frequency Inverter (유도가열용 ZCS PWM SEPP 고주파 인버터의 특성)

  • Mun, Sang-Pil;Kim, Chil-Ryong;Kwak, Dong-Kurl;Kim, Choon-Sam;Nakaoka, Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.133-135
    • /
    • 2007
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Pull)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF

Soft Switching High Frequency Inverter for New Induction Heating (새로운 유도가열용 소프트 스위칭 고주파 인버터)

  • Kim, C.Y.;Mun, S.P.;Kim, M.Y.;Kim, H.J.;Lyu, J.Y.;Kim, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 2007.11c
    • /
    • pp.119-124
    • /
    • 2007
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Pull)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF

A New Three-Phase Current Modulation Method to Suppress the Commutation Torque Ripple of Brushless DC Motor

  • Wang, Zhiqiang;Yin, Shuai;Ma, Tiehua
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1925-1933
    • /
    • 2017
  • The brushless DC motor's commutation torque ripple is caused by inconsistency in the rate of phase current change. Thus, a method that considers armature resistance is proposed to modulate phase current. The three-phase control strategy, which involves the "open-phase conduction, off-phase pulse width modulation, and maintained non-commutation phase" technique, is applied during commutation at full-speed segments of the motor. Changes in each phase current are analyzed theoretically by establishing mathematical model based on phase current to determine the relative difference among shutdown phase, duty, and motor operating parameters. The turn-on and turn-off phase current change rates are made to be consistent to ensure less non-commutation phase current ripple, then the torque ripple is inhibited. The simulation results show that the phase commutation current and torque ripple coefficient of the proposed method are reduced from 56.9% and 55.5% to 6.8% and 6.1%, respectively. In the experiment system, the pulsation coefficient of the motor phase current is reduced from 40.0% to 16.7% at low speed and 50.0% to 18.8% at high speed. The simulation and experimental results show that the proposed control method significantly inhibits commutation current and torque in the full section.

Improvement Strategies of Arriving Time to the Scene by Enhancing EMTs' Recognition of Triage (구급출동지령서 개선을 통한 구급대원 현장 도착시간 단축방안)

  • Oh, Won Sin;Joung, Suck Hwan;Yoon, Myong Oh
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.1
    • /
    • pp.45-52
    • /
    • 2015
  • The purpose of this investigation is to enhance the survival rate of patients by transporting them to the hospital within the golden hour through the operational improvement of emergency dispatch instruction. To this end, problems and improvements of current operating system were derived by carrying out a survey against paramedics of Incheon city in 2012 and analyzing the current emergency dispatch instruction. This study analyzed the emergency activity daily reports for one year from January 1 through December 31, 2012 and researched the consciousness of 119 emergency medical technician. According to the analysis of the survey, there were no meaningful differences in the on-site arrival times per triage. Therefore, the item of 'Emergency Classification' specified in the emergency dispatch instruction needs to be integrated in the scheme of "triage". Also, the feedbacks of the emergency action log and the emergency dispatch instruction are necessary for 'duty for operation' to review the adequacy to the severity after the end of emergency operation. Finally, the improvement of the system for the continuous communication between the paramedics and the command staff is necessary. This improvements as stated above are expected to contribute to raise survival rate of patients.