• Title/Summary/Keyword: Operating control system

Search Result 3,090, Processing Time 0.03 seconds

A study on the improvement of loading and unloading work in laver aquaculture industry (양식 생김의 양륙 작업 개선에 관한 연구)

  • MIN, Eun-bi;YOON, Eun-a;HWANG, Doo-jin;KIM, Ok-sam;YOO, Geum-bum
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.56 no.1
    • /
    • pp.45-54
    • /
    • 2020
  • In this study, an automatic system for improving the working environment and increasing production efficiency of a laver aquaculture industry in Korea was developed by combining a hydraulic control system and a load cell in a current landing work of the laver. The improved gathering laver system allowed the automatic gathering process of the laver in the sea with the hydraulic control system connected to a cutting machine of the laver on the operating ship, which has been used for gathering the laver semi-automatically in a form of the traditional farming method. The transporting process of the laver from an operating ship to the land was improved as follows. A frame installed on the operating ship and the bag nets were designed and made to hold about 1,000 kg of the laver inside. The bag nets contain the laver on the improved operating ship were tied in knots and hooked on a crane using a load cell. The weight is measured immediately by lifting the bag nets through the load cell system. Weight information is communicated to the fishermen and successful bidders through the application. The advantages of the improved system can help fishermen to fish by improving their working environment and increasing production efficiency. The field survey to improve the landing operation of the laver aquaculture was conducted in Gangjin, Goheung, Shinan, Wando, Jindo, and Haenam in South Jeonnam Province. A total of 10 sites including Gunsan in Jeonbuk Province, Daebu Island in Ansan City, Jebu Island in Hwaseong City in Gyeonggi Province, and Seocheon in Chungnam Province were searched to collect data. Prototypes of the system were tested at the auction house of laver located in Goheung, where laver collection using hydraulic control and landing using road cell could be improved.

Operating Method of BESS for Providing AGC Frequency Control Service Considering Its Availability Maximization (배터리 가용성 극대화를 고려한 BESS의 AGC 주파수제어 추종운영방안)

  • Choi, Woo Yeong;Yu, Ga Ram;Kook, Kyung Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1161-1168
    • /
    • 2016
  • Battery energy storage system(BESS) attract the attention of the power system operators with its fast response to a disturbance in spite of its limited energy capacity. This paper proposes the operating method of BESS for following the Automatic Generation Control(AGC) frequency control which is centrally distributed by a system operator. As BESS needs to just meet the control requirement from the system operator, it should be able to properly manage the state of charge(SOC) of BESS to be available to control signal. For doing these, the proposed method distributes the control requirement to available batteries in proportion to its SOC. In addition, unavailable batteries are controlled to recover the SOC to an appropriate range, and the recovering power is supplied by available batteries meeting the control requirement. Moreover, the proposed method manages the efficiency of power conversion system (PCS) by limiting the number of PCS to be assigned for the low control requirement. Finally, the case studies are carried out to verify the effectiveness of proposed strategy.

Secure User and Program Interface for SecuROS (SecuROS 에서 개발된 사용자 및 프로그램 인터페이스)

  • Doo, So-Young;Go, Jong-Guk;Eun, Seong-Gyeong;Kim, Jeong-Nyeo;Gong, Eun-Bae
    • The KIPS Transactions:PartC
    • /
    • v.8C no.5
    • /
    • pp.557-564
    • /
    • 2001
  • Many people use Linux and FreeBSD because it is freeware and excellent performance. The open source code is very important feature but it also has some problem which may be attacked by hackers frequently. This paper describes the SecuROS of secure operating system that is best solution to this problem and introduces user and programmer interface for active use of secure operating system. Developed secure operating system is composed of the access control method MAC and ACL and conforms to the POSIX which is universally used.

  • PDF

A Study on the Engine-CPP Control of a Ship Propulsion System (선박 추진 시스템의 엔진-CPP 통합적 제어에 관한 연구)

  • 김영복
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.4
    • /
    • pp.427-432
    • /
    • 1998
  • There are many demands for ship control system and many studies have been proposed. For example, if a ship diesel engine is operated by consolidated control with Controllable Pitch Propeller(CPP), the minimum fuel consumption is achieved, satisfying the demanded ship speed. For this, it is necessary that the ship is operated on the ideal operating line which satisfies the minimum fuel consumption. In this context of view, this paper presents a controller design method for a ship propulsion system with CPP by Linear Matrix Inequality(LMI) which satisfies the given $H_{\infty}$ control performance and robust stability in the presence of physical parameter perturbations. The validity and applicability of this approach are illustrated through a simulation in the all operating ranges.

  • PDF

Control Strategy of Improved Transient Response for a Doubly Fed Induction Generator in Medium Voltage Wind Power System under Grid Unbalance

  • Han, Daesu;Park, Yonggyun;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.246-247
    • /
    • 2013
  • This paper investigates control algorithms for a doubly fed induction generator with a back-to-back three-level neutral-point clamped voltage source converter in medium voltage wind power system under unbalanced grid conditions. Control algorithms to compensate for unbalanced conditions have been investigated with respect to four performance factors; fault ride-through capability, instantaneous active power pulsation, harmonic distortions, and torque pulsation. The control algorithm having zero amplitude of torque ripple shows the most cost-effective performance concerning torque pulsation. The least active power pulsation is produced by control algorithm that nullifies the oscillating component of the instantaneous stator active and reactive power. Combination of these two control algorithms depending on the operating requirements and depth of grid unbalance presents most optimized performance factors under the generalized unbalanced operating conditions leading to high performance DFIG wind turbine system. The proposed control algorithms are verified through transient response in the simulation.

  • PDF

STUDY ON THE OPERATING CONDITION AND STABILITY OF CONTROL SYSTEM IN THE SPACE OF ADJUSTING PARAMETERS (조정파라미터 공간에서의 제어계 동작점과 안정성에 관한 연구)

  • 최순만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.470-477
    • /
    • 2000
  • The states of control loops in existing actual systems are changed according to time varying conditions of controllest process and other system components. Adjusting control parameters properly at site which is performed generally by Ziegler & Nichols mthod is important for safe and efficient operation, but the method may require much time to adjust and not easy to inexperienced engineers. This study is aimed to propose more handy method to adjust control parameters by plotting operating conditions on the space of adjusting parameters. One loop of model control system without perturbation condition has been adopted and its stability limit was plotted on the coordinates of Gain and Integral time which was acquired after analyzing Nyquist diagrams and time domain responses. The result showed that the sets of adjusting parameters according to critical stability and proper stability could be acquired reasonably through both responses and the curves on parameter space revealed available patterns for the purpose of easy maintenance of control characteristics.

  • PDF

Robust Decoupling Control of Ship Propulsion System with CPP (CPP를 갖는 선박 추진 시스템의 강인한 Decoupling 제어)

  • 김영복;변정환
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.9
    • /
    • pp.33-42
    • /
    • 1998
  • If a ship diesel engine is operated by consolidated control with Controllable Pitch Propeller(CPP), the minimum fuel consumption is achieved together with the demanded ship speed. For this, it is necessary that the ship is operated on the ideal operating line which satisfies the minimum fuel consumption and that the pitch angle of CPP and throtle valve angle are controlled simultaneously. In this point of view, this paper presents a controller design method for a ship propulsion system with CPP based on the decoupling control theory. To do this, Linear Matrix Inequality(LMI) approach is introduced for the control system to satisfy the given $H_\infty$ control performance and robust stability in the presence of physical parameter perturbations. The validity and applicability of this approach are illustrated by simulation in the all operating ranges.

  • PDF

A study for the system voltage and reactive power control (계통전압.무효전력 제어에 관한 연구)

  • 송길영
    • 전기의세계
    • /
    • v.14 no.3
    • /
    • pp.10-17
    • /
    • 1965
  • This paper presents a method of the voltage-reactive power control in the long and short range operations and introduces a conception, "optimum control pattern." The optimum control pattern, aiming at the over-all system control, is defined as the optimum voltage distribution which minimizes the system operating cost under the conditions that the specified power be supplied and the system voltage be kept within the specified bounds. The following procedure was adopted to obtain this optimum pattern. In the first place, a power system was divided into three blocks, namely, load, substation and generator. Lagrange's, multiplier method is applied to each block in turn, paying attention only at the operating voltage distribution. Phase angles at each bus are then modified so that the continuity of active power is maintained. This procedure may be called "block relaxation method with Lagrange's multipliers." In a long range operation, this control pattern determines the optimum installation capacity of reactive power sources. In a short range operation, it also gives the reference state of real time control and the optimum switching capacity of reactive power souces. The real time control problem is also studied from the standpoint of cooperation of control devices such as generators, shunt capacitors, shunt reactors and ratio load controllers. A proposal for the real time control will contribute to the automation of power system operation in the near future. in the near future.

  • PDF

Implementation of an EtherCAT Master with SOEM on STM32 Microcontroller (STM32 마이크로 컨트롤러에서 SOEM을 이용하는 EtherCAT 마스터 구현)

  • Sung Jin Kang;Hwa Il Seo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.2
    • /
    • pp.11-16
    • /
    • 2023
  • EtherCAT is an Ethernet-based fieldbus system standardized in IEC 61158 and SEMI, and widely used in the fields of factory automation, semiconductor equipment and robotics. In this paper, without operating system, we have implemented an EtherCAT master with an open source EtherCAT master stack SOEM on STM32 Nucleo-144 board with an STM32F767 microcontroller. And its jitter performance has been evaluated at the output of the network port to include all the effects of the entire system in the results. The results show that the implemented EtherCAT master has precise control performance for control frequencies from 1KHz to 8KHz and relatively superior jitter performance compared to the EtherCAT masters with real-time patched Linux operating system.

  • PDF

Robust position control of DC motor using fuzzy acceleration control (퍼지 가속도제어를 이용한 직류전동기의 강인한 위치제어)

  • 박귀태;이기상;배상욱;박태홍
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.451-456
    • /
    • 1991
  • A robust position control scheme for DC Motor is proposed based on Fuzzy Acceleration Control. Proposed control system has the similar structure that Y. Hori proposed. But the PI type acceleration controller of it is replaced by Fuzzy Logic Controller(FLC) which is known to be robust to the operating point and parameter variations. By the simulation study for a real DC Motor, we have slowed the superiority to the continuous PI acceleration controller in the view point of robustness to the operating point and parameter variations.

  • PDF