• 제목/요약/키워드: Operating conditions

검색결과 5,011건 처리시간 0.037초

단결정 실리콘 태양전지 최적 운전조건을 위한 주파수 특성 분석 (Analysis of Frequency Property for Optimal Operating Conditions of Mono-crystalline Si Solar Cell)

  • 김지웅;최용성;이경섭;조수영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2060-2060
    • /
    • 2011
  • This paper was investigated the frequency property for optimal operating conditions of mono-crystalline Si solar cell. An internal impedance of mono-crystalline Si solar cell was influenced frequency. An optimal operating conditions of solar cell was under about 10[kHz].

  • PDF

가변속 스크롤 압축기의 운전조건의 변화에 따른 성능 해석 (Performance Analysis on the Variable Speed Scroll Compressor with Operating Conditions)

  • 박홍희;박윤철;김용찬
    • 설비공학논문집
    • /
    • 제12권7호
    • /
    • pp.649-658
    • /
    • 2000
  • Thermodynamic modeling of low-pressure scroll compressor was developed by combining continuity and energy conservation equation. Suction gas heating was considered using energy balance inside the low pressure shell. Pressure, temperature and mass of refrigerant-22 as a function of orbiting angle were calculated by solving the governing equations using fourth order Rung-Kutta scheme. Motor efficiency was taken by experiments with a variation of frequency. The developed model was applied to the analysis of an inverter driven scroll compressor with a variation of frequency, pressure ratio and operating conditions. The model was verified with the experimental results at the same operating conditions. The developed model was adequate to predict performance of the inverter driven scroll compressor as a function of operating conditions. Calculated parameters from the model were discharge temperature, mass flow rate, power input, COP, and thermodynamic properties with respect to orbiting angle. To enhance the performance of a scroll compressor, it is essential to diminish leakage at low frequency level and improve the mechanical efficiency at high frequency level.

  • PDF

500W급 공냉식 고분자 연료전지 설계, 제작 및 운전 특성 (The Analysis of the Operating Characteristics In A 500W Portable Air Cooled Polymer Electrolyte Membrane Fuel Cell (PEMFC))

  • 손영준;양태현;박구곤;임성대;윤영기;이원용;김창수
    • 한국전기화학회:학술대회논문집
    • /
    • 한국전기화학회 2004년도 수소연료전지공동심포지움 2004논문집
    • /
    • pp.37-42
    • /
    • 2004
  • To maintain proper operating conditions is important to get optimal output power of a PEMFC stack. The air cooled fuel cell stack is widely used in sub kW PEMFC systems. A 500W air cooled PEMFC stack was experimentally investigated to evaluate the design performance and to get optimal operating conditions for the portable application. The relationship between the operating conditions and the performance was analyzed. The results can be used as design criteria for portable PEMFC under various conditions.

  • PDF

전력계통 적용을 위한 배터리 에너지저장장치의 동적 제어모드 판단기준에 관한 연구 (A Study on the Criteria for Setting the Dynamic Control Mode of Battery Energy Storage System in Power Systems)

  • 한준범;유가람;국경수;장병훈
    • 전기학회논문지
    • /
    • 제62권4호
    • /
    • pp.444-450
    • /
    • 2013
  • This paper presents the criteria for setting the dynamic operating mode of BESS(Battery Energy Storage System) in the bulk power systems. ESS has been expected to improve the degraded dynamic performance of the power system with high penetration of the renewable resources. While ESS is controlled in steady state or dynamic operating mode for its better effectiveness depending on the operating conditions of power systems, the criteria for setting the dynamic operating mode for the transient period needs to be robust enough to cover all the different conditions. The proposed criteria consider the varying conditions and the operating practices of the bulk power systems.

마이크로플루트 골판지생산을 위한 실험용 코루게이터의 최적 운전조건 탐색 (Investigation on the Lab Scale Corrugator's Optimum Operating Conditions for Making Microflute Corrugated Paperboards)

  • 조용민;엄기증
    • 펄프종이기술
    • /
    • 제39권2호
    • /
    • pp.54-59
    • /
    • 2007
  • Cereal, computer software, wine, small appliances, and fast foods are examples of products that have switched from folding carton to microflute corrugated paperboard. Microflute corrugated paperboards have their unique wonderful packaging characteristics that are driving forces for people to use more and more. Good strength property, excellent shock absorbing ability, and beautiful outer appearance of microflute corrugated paperboards go hand and hand with their environmental advantages. It is known that physical properties of microflute corrugated paperboards depend on not only properties of base paper but corrugator operating conditions. This study was carried out to investigate on the corrugator's optimum operating conditions for making micro flute corrugated paperboards. Lab-scaled micro flute corrugator was installed and run with systematic changes of operation conditions to investigate the effects of operation conditions on physical properties of micro flute corrugated paperboards.

Factorial Experiment for Drum-type Secondary Separating Part of Self-propelled Pepper Harvester

  • Nam, Ju-Seok;Kang, Young-Sun;Kim, Su-Bin;Kim, Dae-Cheol
    • Journal of Biosystems Engineering
    • /
    • 제42권4호
    • /
    • pp.242-250
    • /
    • 2017
  • Purpose: This study was conducted to determine the appropriate operating conditions through a factorial experiment for the secondary separating part of the self-propelled pepper harvester. Methods: An experimental setup that simulates the secondary separating part of the self-propelled pepper harvester was organized. Test samples were classified into three types according to the number of peppers on a stem, and 12 sets were prepared for each type. Among the operating conditions of the secondary separating part, the rotational speed of drum B (four levels), radial clearance between drums and cylindrical teeth (three levels), and speed ratio between the three drums (two levels) were set as the test factors, and tests were repeated three times for different levels of each factor. The appropriate operating conditions were determined by analyzing the separation ratio and damage ratio of the peppers collected through the secondary separating part. Results: The test factors changed the overall separation ratio and overall damage ratio in similar trends. In other words, the conditions that caused high overall separation ratios also exhibited high overall damage ratios. Owing to the high overall damage ratio in the condition with the highest overall separation ratio, the operating conditions should be selected considering both ratios. Conclusions: When the condition with more than 60% of overall separation ratio and less than 15% of overall damage ratio was considered as the appropriate operating condition, 70 rpm of the rotational speed of drum B, 5 mm of the radial clearance between drums and cylindrical teeth, and 7:3:5 for the speed ratio of the three drums A, B, and C should be applied for the secondary separating part used in this study. Supplementary studies will be required in the future to find optimal operating conditions through the actual field test under further divided test factors.

SNU 1.5-MV 직렬형 반데그라프 가속기의 $He^{++}$ 빔 소송계에 대한 이온광학적 고찰 (Ion Optical Study on the $He^{++}$ Beam Transport System of the SNU 1.5-MV Tandem Van do Graaff Accelerator)

  • Hyen-Cheol JO;Young-Dug BAE;Hae-iLL BAK
    • Nuclear Engineering and Technology
    • /
    • 제23권4호
    • /
    • pp.426-437
    • /
    • 1991
  • SNU 1.5-MV 직렬형 반데그라프 가속기의 $He^{++}$ 빔 수송계를 이온광학적으로 분석하였다. 각 이온광학요소의 최적운전조건을 결정하고, 이온빔 수송을 모사하기 위하여 프로그램 OPTRANS를 개발하였다. 일차행렬법을 사용하였으며, 공간전하효과는 무시하였다. 프로그램 OPTRANS를 사용하여 0.5~3.0 MeV $He^{++}$ 빔 수송을 위한 최적운전조건을 결정하였다. 초기 이온빔의 방사면량은 인출전극의 구조와 이온빔 인출실험에 의해 0.5$\times$80.0 mm.mrad으로 가정하였다. 운전조건의 변화에 따른 각 이온광학요소의 이온빔 수송 특성을 검토하였으며, 각 Slit과 Stripping Foil, 그리고 표적에서 빔 크기가 최소로 되도록 하는 운전조건을 계산하였다. 이온빔 수송 실험으로부터 얻어진 최적운전조건은 계산된 값과 오차 범위 15% 내에서 일치하였다. 이온빔 수송 모사와 실험을 통해, 계산된 최적운전조건의 타당성 및 프로그램 OPTRANS의 유용성을 입증하였다.

  • PDF

실험계획법을 이용한 고온 고분자 전해질 막 연료전지의 운전조건 최적화 연구 (Study on Optimization of Operating Conditions for High Temperature PEM Fuel Cells Using Design of Experiments)

  • 김진태;김민진;손영준
    • 한국수소및신에너지학회논문집
    • /
    • 제24권1호
    • /
    • pp.50-60
    • /
    • 2013
  • High temperature proton exchange membrane fuel cells (PEMFCs) using phosphoric acid (PA) doped polybenzimidazole (PBI) membranes have been concentrated as one of solutions to the limits with traditional low temperature PEMFCs. However, the amount of reported experimental data is not enough to catch the operational characteristics correlated with cell performance and durability. In this study, design of experiments (DOE) based operational optimization method for high temperature PEMFCs has been proposed. Response surface method (RSM) is very useful to effectively analyze target system's characteristics and to optimize operating conditions for a short time. Thus RSM using central composite design (CCD) as one of methodologies for design of experiments (DOE) was adopted. For this work, the statistic models which predict the performance and degradation rate with respect to the operating conditions have been developed. The developed performance and degradation models exhibit a good agreement with experimental data. Compared to the existing arbitrary operation, the expected cell lifetime and average cell performance during whole operation could be improved by optimizing operating conditions. Furthermore, the proposed optimization method could find different new optimal solutions for operating conditions if the target lifetime of the fuel cell system is changed. It is expected that the proposed method is very useful to find optimal operating conditions and enhance performance and durability for many other types of fuel cell systems.

공기분급식 미분쇄기의 운전조건이 미세분말의 크기에 미치는 영향 (Effects of Operating Conditions of an Air-Classifier Mill on the Particle Size of Fine Powder)

  • 신응수;김기성;김용욱
    • 한국생산제조학회지
    • /
    • 제25권6호
    • /
    • pp.426-433
    • /
    • 2016
  • This paper investigates the effects of operating conditions of an air classifier mill (ACM) on the particle sizes of PVC and rice hull. Based on the Box-Behnken matrix, the pulverization experiments were performed considering three operating factors: the air flow rate, the classifier speed and the mill speed. The response surface methodology was applied to identify the effects of the operating factors on the particle size. Results show that the particle sizes are governed by the linear variations of the operating factors. As less air is supplied and the mill rotates more slowly, the powder of both PVC and rice hull becomes finer. Furthermore, the classifier speed has a significant effect on the PVC powder but almost no effect on the rice hull powder. Thus, it is found that strong interactions exist between the material characteristics of a particle and the operating conditions of the ACM.

이동 전원용 공랭식 고분자 연료전지의 제작 및 운전 특성 연구 (Operating characteristics of an air cooling PEMFC for portable application)

  • 손영준;박구곤;양태현;윤영기;이원용;임성대;김창수
    • 신재생에너지
    • /
    • 제1권1호
    • /
    • pp.72-78
    • /
    • 2005
  • Optimal design and proper operation are important to get aimed output power of a polymer electrolyte membrane fuel cell (PEMFC) stack. An air cooling fuel cell stack is widely used in sub kW PEMFC systems. The purpose of this study is to analyze operating conditions affecting the performance of the air cooling PEMFC which is designed for portable application. In portable applications, air cooling stack is difficult to maintain well balanced operating conditions. The importart parameters are the relative humidity, the temperature of the stack, the utilization of reactant gas and so on. in this study, a 500W air cooling PEMFC was fabricated and tested to evaluate the design performance and to determine optimal operating conditions. Moreover, basic modeling also is carried out. These results can be used 3s design criteria and optimal operating conditions for portable PEMFCs

  • PDF